-- ***************************************************************** -- RC7586.mib: Codan's 7586 Controller product MIB -- -- Created by Magdalena Raltcheva -- -- Copyright (c) 2009 by Codan Limited. -- All rights reserved. -- -- ***************************************************************** RC7586-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, TimeTicks, IpAddress, Gauge32, Counter32 FROM SNMPv2-SMI DisplayString, DateAndTime, TEXTUAL-CONVENTION, TestAndIncr,TimeInterval, TruthValue FROM SNMPv2-TC satcomMibs FROM CODAN-SMI; rc7586MIB MODULE-IDENTITY LAST-UPDATED "200905130000Z" ORGANIZATION "Codan Limited." CONTACT-INFO " Magda Raltcheva Postal: Codan Limited 81 Graves St. Newton 5074 Australia Tel: +61-8-83050311 Fax: +61-8-83050411 Web: www.codan.com.au" DESCRIPTION "The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved" REVISION "200905130000Z" DESCRIPTION "1.0 Initial version of this MIB module." ::= { satcomMibs 2 } -- assigned by IANA -- ***##############################################################*** -- CodanMIB Textual Convention Definitions -- ***##############################################################*** ComponentRevision ::= TEXTUAL-CONVENTION DISPLAY-HINT "vxx.yy" STATUS current DESCRIPTION "The hex value in the first octet - xx - represents the major revision no. and the hex value in the second octet - yy - represents the minor revision no." SYNTAX DisplayString(SIZE(2)) -- ***##############################################################*** -- CodanMIB Textual Convention Definitions for 7586 Controller -- ***##############################################################*** FaultStatus7586 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Describes all the possible faults in the system as a bit pattern." SYNTAX BITS { dc1fault(0), dc2fault(1), buc1fault(2), buc2fault(3), lnb1fault(4), lnb2fault(5), txswfault(6), rxswfault(7), internalfault(8), ref10mhzfault(9) } -- ***##############################################################*** -- CodanMIB Textual Convention Definitions for RBUC -- ***##############################################################*** -- ***##############################################################*** -- Devices within the 7586 Controller MIB -- ***##############################################################*** buc1 OBJECT IDENTIFIER ::= { rc7586MIB 1 } buc2 OBJECT IDENTIFIER ::= { rc7586MIB 2 } ctrl OBJECT IDENTIFIER ::= { rc7586MIB 3 } --------------------------- 7586 Controller -------------------------- -- ***##############################################################*** -- Groups within the 7586 Controller MIB -- ***##############################################################*** settings OBJECT IDENTIFIER ::= { ctrl 1 } status OBJECT IDENTIFIER ::= { ctrl 2 } info OBJECT IDENTIFIER ::= { ctrl 3 } -------------- Settings group operationalMode OBJECT-TYPE SYNTAX INTEGER (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets 7586 operational mode - Auto, Manual Stream1, Stream2." ::= { settings 1 } onlineStream OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets the online stream." ::= { settings 2 } waveguideSwitch OBJECT-TYPE SYNTAX INTEGER (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets Waveguide switch Rx+Tx, Rx/Tx and Tx Only." ::= { settings 3 } startupTime OBJECT-TYPE SYNTAX INTEGER (0..50) UNITS "s" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets Startup time." ::= { settings 4 } lnbCurrentLimit OBJECT-TYPE SYNTAX DisplayString UNITS "mA" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets LNB current limits." ::= { settings 5 } ledState OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets 7586 LED." ::= { settings 6 } refSource OBJECT-TYPE SYNTAX INTEGER (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets 7586 reference state." ::= { settings 7 } refTrim OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Sets 7586 reference trim." ::= { settings 8 } refThresh OBJECT-TYPE SYNTAX DisplayString UNITS "dBm" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets 7586 reference alarm treshold." ::= { settings 9 } refPwr OBJECT-TYPE SYNTAX DisplayString UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Gets 7586 reference power." ::= { settings 10 } -- Network - read only ipAddr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the 7586 IP address." ::= { settings 11 } macAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the 7586 MAC address." ::= { settings 12 } netmask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the 7586 netmask." ::= { settings 13 } gateway OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the 7586 gateway address." ::= { settings 14 } -------------- Status group lnbCurrent OBJECT-TYPE SYNTAX DisplayString UNITS "mA" MAX-ACCESS read-only STATUS current DESCRIPTION "Sets 7586 LNB current." ::= { status 1 } lnbVoltage OBJECT-TYPE SYNTAX DisplayString UNITS "V" MAX-ACCESS read-only STATUS current DESCRIPTION "Sets 7586 LNB voltage." ::= { status 2 } faults OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the current fault status." ::= { status 3} ------------------ Info group idInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown." ::= { info 1 } --------------------------- RBUCs ------------------------------------ -- ***##############################################################*** -- Groups within the BUC1,BUC2 MIB -- ***##############################################################*** buc1Configuration OBJECT IDENTIFIER ::= { buc1 1 } buc1Status OBJECT IDENTIFIER ::= { buc1 2 } buc1Info OBJECT IDENTIFIER ::= { buc1 3 } buc2Configuration OBJECT IDENTIFIER ::= { buc2 1 } buc2Status OBJECT IDENTIFIER ::= { buc2 2 } buc2Info OBJECT IDENTIFIER ::= { buc2 3 } -- #################################################################### -- *** RBUC Configuration groups - run time changing settings *** -- #################################################################### -- *** Configuration groups - *** buc1TxSettings OBJECT IDENTIFIER ::= { buc1Configuration 1 } buc1PktProtocol OBJECT IDENTIFIER ::= { buc1Configuration 2 } buc1RCSetting OBJECT IDENTIFIER ::= { buc1Configuration 3 } buc1Freqs OBJECT IDENTIFIER ::= { buc1Configuration 4 } buc1Misc OBJECT IDENTIFIER ::= { buc1Configuration 5 } buc2TxSettings OBJECT IDENTIFIER ::= { buc2Configuration 1 } buc2PktProtocol OBJECT IDENTIFIER ::= { buc2Configuration 2 } buc2RCSetting OBJECT IDENTIFIER ::= { buc2Configuration 3 } buc2Freqs OBJECT IDENTIFIER ::= { buc2Configuration 4 } buc2Misc OBJECT IDENTIFIER ::= { buc2Configuration 5 } -- Tx Settings Group buc1TxOn OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets Tx on/off. Respond -1 if buc1 not connected." ::= { buc1TxSettings 1 } buc2TxOn OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets Tx on/off. Respond -1 if buc2 not connected." ::= { buc2TxSettings 1 } buc1TxDefault OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets Tx default 1-last 0-off. Respond -1 if buc1 not connected." ::= { buc1TxSettings 2 } buc2TxDefault OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets Tx default 1-last 0-off. Respond -1 if buc2 not connected." ::= { buc2TxSettings 2 } buc1TxAttenuator OBJECT-TYPE SYNTAX INTEGER (0..15) UNITS "dBm" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected." ::= { buc1TxSettings 3 } buc2TxAttenuator OBJECT-TYPE SYNTAX INTEGER (0..15) UNITS "dBm" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected." ::= { buc2TxSettings 3 } -- Packet Protocol Settings Group buc1Protocol OBJECT-TYPE SYNTAX INTEGER (0..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected." ::= { buc1PktProtocol 1 } buc2Protocol OBJECT-TYPE SYNTAX INTEGER (0..4) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected." ::= { buc2PktProtocol 1 } buc1Address OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected. " ::= { buc1PktProtocol 2 } buc2Address OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected." ::= { buc2PktProtocol 2 } -- Redundancy Controller Group buc1Mode OBJECT-TYPE SYNTAX INTEGER (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected." ::= { buc1RCSetting 1 } buc2Mode OBJECT-TYPE SYNTAX INTEGER (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected." ::= { buc2RCSetting 1 } buc1OnLine OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected." ::= { buc1RCSetting 2 } buc2OnLine OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected." ::= { buc2RCSetting 2 } -- Frequency Group buc1RFFreq OBJECT-TYPE SYNTAX INTEGER UNITS "MHz" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected." ::= { buc1Freqs 1 } buc2RFFreq OBJECT-TYPE SYNTAX INTEGER UNITS "MHz" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected." ::= { buc2Freqs 1 } buc1IFFreq OBJECT-TYPE SYNTAX INTEGER UNITS "MHz" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected." ::= { buc1Freqs 2 } buc2IFFreq OBJECT-TYPE SYNTAX INTEGER UNITS "MHz" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected." ::= { buc2Freqs 2 } buc1LOFreq OBJECT-TYPE SYNTAX INTEGER UNITS "MHz" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected." ::= { buc1Freqs 3 } buc2LOFreq OBJECT-TYPE SYNTAX INTEGER UNITS "MHz" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected." ::= { buc2Freqs 3 } -- Miscellaneous Group buc1SerIf OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc1 not connected." ::= { buc1Misc 1 } buc2SerIf OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc2 not connected." ::= { buc2Misc 1 } buc1PwrAlarmThresh OBJECT-TYPE SYNTAX DisplayString UNITS "dB" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets power alarm threshold. **** No respond - message if buc1 not connected." ::= { buc1Misc 2 } buc2PwrAlarmThresh OBJECT-TYPE SYNTAX DisplayString UNITS "dB" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets power alarm threshold. **** No respond - message if buc2 not connected." ::= { buc2Misc 2 } buc1BurstPwrThresh OBJECT-TYPE SYNTAX DisplayString UNITS "dB" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets burst power threshold. **** No respond - message if buc1 not connected." ::= { buc1Misc 3 } buc2BurstPwrThresh OBJECT-TYPE SYNTAX DisplayString UNITS "dB" MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets burst power threshold. **** No respond - message if buc2 not connected." ::= { buc2Misc 3 } buc1RefSource OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc1 not connected." ::= { buc1Misc 4 } buc2RefSource OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc2 not connected." ::= { buc2Misc 4 } buc1LEDState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc1 not connected." ::= { buc1Misc 5 } buc2LEDState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Sets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc2 not connected." ::= { buc2Misc 5 } -- #################################################################### -- *** RBUC Status Group *** -- #################################################################### buc1PaStatus OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Gets to 1 when PA is on. Respond -1 if buc1 not connected." ::= { buc1Status 1 } buc2PaStatus OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Gets to 1 when PA is on. Respond -1 if buc2 not connected." ::= { buc2Status 1 } buc1TxPower OBJECT-TYPE SYNTAX DisplayString UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Gets Tx power format x.x dB. **** No respond - message if buc1 not connected." ::= { buc1Status 2} buc2TxPower OBJECT-TYPE SYNTAX DisplayString UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Gets Tx power format x.x dB. **** No respond - message if buc2 not connected." ::= { buc2Status 2} buc1TxBurstPower OBJECT-TYPE SYNTAX DisplayString UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc1 not connected." ::= { buc1Status 3} buc2TxBurstPower OBJECT-TYPE SYNTAX DisplayString UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Gets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc2 not connected." ::= { buc2Status 3} buc1Faults OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected." ::= { buc1Status 4} buc2Faults OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected." ::= { buc2Status 4} buc1LatchedFaults OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected." ::= { buc1Status 5} buc2LatchedFaults OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected." ::= { buc2Status 5} buc1Temperature OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC temperature. Format is x.x. **** No respond - message if buc1 not connected." ::= { buc1Status 6} buc2Temperature OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC temperature. Format is x.x. **** No respond - message if buc2 not connected." ::= { buc2Status 6} buc1MinMaxTemperature OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc1 not connected." ::= { buc1Status 7} buc2MinMaxTemperature OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc2 not connected." ::= { buc2Status 7} buc1SystemSetting OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc1 not connected." ::= { buc1Status 8} buc2SystemSetting OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc2 not connected." ::= { buc2Status 8} buc1SystemPoll OBJECT-TYPE SYNTAX INTEGER (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc1 not connected." ::= { buc1Status 9} buc2SystemPoll OBJECT-TYPE SYNTAX INTEGER (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc2 not connected." ::= { buc2Status 9} buc1DeviceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc1 not connected." ::= { buc1Status 10} buc2DeviceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc2 not connected." ::= { buc2Status 10} buc1Gateway OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC gateway address (Only for RBUC). **** No respond - message if buc1 not connected." ::= { buc1Status 11} buc2Gateway OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC gateway address (Only for RBUC). **** No respond - message if buc2 not connected." ::= { buc2Status 11} buc1IpAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC IP address (Only for RBUC). **** No respond - message if buc1 not connected." ::= { buc1Status 12} buc2IpAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC IP address (Only for RBUC). **** No respond - message if buc2 not connected." ::= { buc2Status 12} buc1MACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC MAC address (Only for RBUC). **** No respond - message if buc1 not connected." ::= { buc1Status 13} buc2MACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC MAC address (Only for RBUC). **** No respond - message if buc2 not connected." ::= { buc2Status 13} buc1Netmask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC netmask (Only for RBUC). **** No respond - message if buc1 not connected." ::= { buc1Status 14} buc2Netmask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC netmask (Only for RBUC). **** No respond - message if buc2 not connected." ::= { buc2Status 14} buc1RefPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC reference power. **** No respond - message if buc1 not connected." ::= { buc1Status 15} buc2RefPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC reference power. **** No respond - message if buc2 not connected." ::= { buc2Status 15} buc1Config OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC configuration. **** No respond - message if buc1 not connected." ::= { buc1Status 16} buc2Config OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC configuration. **** No respond - message if buc2 not connected." ::= { buc2Status 16} buc1BuildStandard OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC build standard. **** No respond - message if buc1 not connected." ::= { buc1Status 17} buc2BuildStandard OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the BUC build standard. **** No respond - message if buc2 not connected." ::= { buc2Status 17} -- #################################################################### -- *** RBUC Info groups - version, model serial No *** -- #################################################################### buc1IdInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected." ::= { buc1Info 1 } buc2IdInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected." ::= { buc2Info 1 } buc1Limits OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected." ::= { buc1Info 2 } buc2Limits OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected." ::= { buc2Info 2 } buc1PktProtocolsInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets supported packet protocols and the corresponding address ranges. **** No respond - message if buc1 not connected." ::= { buc1Info 3 } buc2PktProtocolsInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Gets supported packet protocols and the corresponding address ranges. **** No respond - message if buc2 not connected." ::= { buc2Info 3 } END