All MIBs › PANDATEL-BMP-MODEM-MIB
Category: Modems
Description:
Manages Pandatel BMP series modem configuration, line status, and performance statistics.
Imported Objects
From PANDATEL-MODEM-MIB
| device-id | |
| mdmSpecifics | OBJECT-IDENTITY |
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| enterprises |
From RFC1213-MIB
| DisplayString |
What Is PANDATEL-BMP-MODEM-MIB?
PANDATEL-BMP-MODEM-MIB is a Pandatel AG (leased-line modem/multiplexer vendor) proprietary MIB reporting BM-P baseband-modem inventory and configuration across modem racks. Its modem table, keyed by rack/position, records modem name, data-equipment emulation, clock mode, distance, data-rate adaptation, clock source, data rate, and local carrier-detect 1/2 status. As a configuration/status MIB it lets an administrator confirm clocking and data-rate settings and carrier-detect status for a specific BM-P modem in a Pandatel rack. It is deployed on Pandatel AG BM-P modem equipment. Engineers can download the PANDATEL-BMP-MODEM-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in PANDATEL-BMP-MODEM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- per-modem clocking, data-rate, and carrier-detect status
Supported Devices
- Pandatel AG BM-P modem equipment
Monitoring Examples
An administrator checks mdmLocalCarrierDetect1 and mdmClockSource to confirm carrier status and clocking configuration for a specific BM-P modem in a Pandatel rack.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| bmp | 1.3.6.1.4.1.760.1.1.2.1.10.301 | |||
| bmpModemTable | 1.3.6.1.4.1.760.1.1.2.1.10.301.1 | not-accessible | This table contains information about all BM-P modems in all racks. | |
| bmpTableEntry | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1 | not-accessible | The index of the table. | |
| INT mdmRack | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.1 | INTEGER | read-only | The index of the rack where the modem is installed. |
| INT mdmModem | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.2 | INTEGER | read-only | This variable displays the slot number where the corresponding modem is installed in the rack. |
| INT mdmPosition | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.3 | INTEGER | read-only | This variable displays the location of the corresponding modem: 'local' or 'remote'. The modem which is plugged into a managed rack is 'local', the counterpart is 'remote'. |
| STR mdmModemName | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.5 | DisplayString | read-only | The verbal name of this modem. |
| INT mdmDataEquipmentEmulation | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.6 | INTEGER | read-only | Interface mode of the unit: 'dte' or 'dce', 'te' or 'nt'. |
| INT mdmClockMode | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.20 | INTEGER | read-write | The clock mode of the unit: 'master' or 'slave'. |
| INT mdmDistance | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.21 | INTEGER | read-write | The transmission distance of the unit: 'long' or 'short'. 'Long' is valid for link data rates of up to 64 Kbps. For data rates higher than 64 Kbps this entry must be set to 'short'. |
| INT mdmDataRateAdaptation | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.22 | INTEGER | read-write | This entry enables or disables data rate adaptation, i.e. one unit operates at line speed and the other one at lower speeds (1.2, 2.4, 4.8 or 9.6 Kbps at 64 Kbps line speed and 1.2, 2.4, 4.8, 9.6 or 19.2 Kbps at 128 Kbps line speed). |
| INT mdmClockSource | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.24 | INTEGER | read-write | The clock source of the link: 'internal', 'external', or 'async'. |
| INT mdmDataRate | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.25 | INTEGER | read-write | The data rate at the interface in bits per seconds. If dataRateAdaptation is disabled, the data rate at the remote counterpart changes simultaneously. Otherwise the data rate at one unit is fixed to line speed and the data rate at the other unit must be set to speeds lower than line speed. |
| INT mdmLocalCarrierDetect1 | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.60 | INTEGER | read-write | The data carrier detect mode at the interface: if set to 'fo-link-and-remote-handshake' the DCD signal (resp. I for X.21, etc.) follows link status and remote RTS (resp. C for X.21, etc.), if set to 'fo-link' the DCD signal follows link status only. |
| INT mdmLocalCarrierDetect2 | 1.3.6.1.4.1.760.1.1.2.1.10.301.1.1.61 | INTEGER | read-write | The data carrier detect mode 2 at the interface: if set to 'fo-link-and-remote-handshake' the DSR signal follows link status and remote RTS (resp. C for X.21, etc.), if set to 'fo-link' the DSR signal follows link status only. |
| bmp_modem | 1.3.6.1.4.1.760.1.1.2.1.10.10000.2.301 |
RFC description
Manages BM-P modem configuration and operation parameters in Pandatel modem racks, including clock modes and data rate settings.
Start monitoring Pandatel AG BM-P modem equipment with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.