All MIBs › OMNI-gx2Rx085BX4-MIB
Category: Cable/DOCSIS
Description: Manages the Cisco/Scientific-Atlanta GX2 RX085BX4 85 MHz quad-port optical receiver card in HFC optical node deployments.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2Rx085BX4-MIB?
OMNI-gx2Rx085BX4-MIB is a vendor-specific SNMP module from Cisco/Scientific-Atlanta covering the GX2 RX085BX4, an 85 MHz quad-port optical receiver card used in hybrid fiber-coax (HFC) optical node platforms. It exposes hardware inventory and per-port operational data for the receiver card, such as card presence, port configuration, and RF/optical signal-related parameters typical of GX2 line cards. Its primary monitoring value is hardware health: detecting card insertion/removal, loss of optical signal, and abnormal receive levels that would indicate a failing optical receiver in the field. As part of the broader OMNI/GX2 MIB family it likely depends on a common GX2 chassis or platform MIB for slot and card indexing conventions. It is deployed by cable operators and MSOs monitoring HFC optical nodes in outside-plant cabinets via SNMP-based network management systems, and operators can download the OMNI-gx2Rx085BX4-MIB file directly to load it into those systems.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2Rx085BX4-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX085BX4 85 MHz quad-port optical receiver card)
Monitoring Examples
No sample objects were provided for this module, so specific object or table names cannot be cited; based on the module name and description, monitoring would typically involve per-port receive level and card status objects analogous to other GX2 receiver card MIBs (e.g., a card/port status table indexed by slot and port). An admin would poll such a table to detect a receiver port reporting loss of signal or an out-of-range optical input level, which would indicate a fiber break or laser transmitter failure upstream. Because no concrete object names were supplied, this description is necessarily generic rather than grounded in specific identifiers.
What Can Be Monitored
- card presence/insertion status
- optical receive signal level
- port operational status
- RF output level
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Rx085BX4 | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapRx085BX4ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.32.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapRx085BX4ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.32.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapRx085BX4OpticalPower1Alarm | 1.3.6.1.4.1.1166.6.1.2.32.0.3 | This trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4OpticalPower2Alarm | 1.3.6.1.4.1.1166.6.1.2.32.0.4 | This trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4OpticalPower3Alarm | 1.3.6.1.4.1.1166.6.1.2.32.0.5 | This trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4OpticalPower4Alarm | 1.3.6.1.4.1.1166.6.1.2.32.0.6 | This trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4ModuleTemperatureAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.7 | This trap is issued when the Rx085BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4FanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.8 | This trap is issued when the Rx085BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Plus12CurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.9 | This trap is issued when the Rx085BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Boot0Alarm | 1.3.6.1.4.1.1166.6.1.2.32.0.10 | This trap is issued when the Rx085BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Boot1Alarm | 1.3.6.1.4.1.1166.6.1.2.32.0.11 | This trap is issued when the Rx085BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.12 | This trap is issued when the Rx085BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.13 | This trap is issued when the Rx085BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.14 | This trap is issued when the Rx085BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4CalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.15 | This trap is issued when the Rx085BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4DefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.16 | This trap is issued when the Rx085BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Mode1Alarm | 1.3.6.1.4.1.1166.6.1.2.32.0.17 | This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Mode2Alarm | 1.3.6.1.4.1.1166.6.1.2.32.0.18 | This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Mode3Alarm | 1.3.6.1.4.1.1166.6.1.2.32.0.19 | This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Mode4Alarm | 1.3.6.1.4.1.1166.6.1.2.32.0.20 | This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Output1SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.21 | This trap is issued when the Rx085BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Output2SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.22 | This trap is issued when the Rx085BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Output3SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.23 | This trap is issued when the Rx085BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4Output4SwitchedAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.24 | This trap is issued when the Rx085BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapRx085BX4RX1StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.25 | This trap is issued when receiver 1 of the Rx085BX4 Module output is turned on or off. | ||
| NTF trapRx085BX4RX2StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.26 | This trap is issued when receiver 2 of the Rx085BX4 Module output is turned on or off. | ||
| NTF trapRx085BX4RX3StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.27 | This trap is issued when receiver 3 of the Rx085BX4 Module output is turned on or off. | ||
| NTF trapRx085BX4RX4StatusAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.28 | This trap is issued when receiver 4 of the Rx085BX4 Module output is turned on or off. | ||
| NTF trapRx085BX4BackupCableAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.29 | This trap is issued when the slave receiver loses connection to the master receiver. | ||
| NTF trapRx085BX4OptPwr1BadAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.30 | This trap is issued when the receiver 1 optical power level falls below the user set switching threshold. | ||
| NTF trapRx085BX4OptPwr2BadAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.31 | This trap is issued when the receiver 2 optical power level falls below the user set switching threshold. | ||
| NTF trapRx085BX4OptPwr3BadAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.32 | This trap is issued when the receiver 3 optical power level falls below the user set switching threshold. | ||
| NTF trapRx085BX4OptPwr4BadAlarm | 1.3.6.1.4.1.1166.6.1.2.32.0.33 | This trap is issued when the receiver 4 optical power level falls below the user set switching threshold. | ||
| gx2Rx085BX4Descriptor | 1.3.6.1.4.1.1166.6.1.2.32.1 | |||
| gx2Rx085BX4AnalogTable | 1.3.6.1.4.1.1166.6.1.2.32.2 | not-accessible | This table contains gx2Rx085BX4 specific parameters with nominal and current values. | |
| gx2Rx085BX4AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.32.2.1 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Rx085BX4AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.32.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rx085labelOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR rx085uomOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO rx085majorHighOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085majorLowOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorHighOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorLowOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085currentValueOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.8 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085stateFlagOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx085minValueOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.10 | Float | read-only | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085maxValueOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.11 | Float | read-only | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085alarmStateOptPowerOne | 1.3.6.1.4.1.1166.6.1.2.32.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR rx085labelOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR rx085uomOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO rx085majorHighOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085majorLowOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorHighOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorLowOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085currentValueOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.19 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085stateFlagOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx085minValueOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.21 | Float | read-only | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085maxValueOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.22 | Float | read-only | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085alarmStateOptPowerTwo | 1.3.6.1.4.1.1166.6.1.2.32.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR rx085labelOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR rx085uomOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO rx085majorHighOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085majorLowOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorHighOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorLowOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085currentValueOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.30 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085stateFlagOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx085minValueOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.32 | Float | read-only | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085maxValueOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.33 | Float | read-only | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085alarmStateOptPowerThree | 1.3.6.1.4.1.1166.6.1.2.32.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR rx085labelOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR rx085uomOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO rx085majorHighOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085majorLowOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorHighOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorLowOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085currentValueOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.41 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085stateFlagOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx085minValueOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.43 | Float | read-only | The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085maxValueOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.44 | Float | read-only | The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085alarmStateOptPowerFour | 1.3.6.1.4.1.1166.6.1.2.32.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR rx085labelModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR rx085uomModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO rx085majorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085majorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085currentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.52 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085stateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx085minValueModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.54 | Float | read-only | The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085maxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.55 | Float | read-only | The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085alarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.32.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR rx085labelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.57 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR rx085uomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO rx085majorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085majorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085currentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.63 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085stateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.64 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx085minValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.65 | Float | read-only | The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085maxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.66 | Float | read-only | The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085alarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.32.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR rx085label12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.68 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR rx085uom12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO rx085majorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085majorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085minorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085currentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.74 | Float | read-only | The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085stateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.75 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO rx085minValue12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.76 | Float | read-only | The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO rx085maxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.77 | Float | read-only | The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT rx085alarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.32.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| gx2Rx085BX4DigitalTable | 1.3.6.1.4.1.1166.6.1.2.32.3 | not-accessible | This table contains gx2Rx085BX4 specific parameters with nominal and current values. | |
| gx2Rx085BX4DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.32.3.2 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Rx085BX4DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.32.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rx085labelModeOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.2 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
| STR rx085enumModeOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueModeOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagModeOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.5 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
| STR rx085enumWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagWavelengthOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
| STR rx085enumAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 60. Each increment represents 1/2 dB of attenuation from 0 to 30 dB. Where 0 = 0db and 60 = 30db |
| INT rx085stateFlagAttnSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
| STR rx085enumSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagSwModeSettingOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.18 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
| STR rx085enumSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.20 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
| INT rx085stateFlagSwModeThresholdOne | 1.3.6.1.4.1.1166.6.1.2.32.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelModeTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.22 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
| STR rx085enumModeTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueModeTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.24 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagModeTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.26 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
| STR rx085enumWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.27 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.28 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagWavelengthTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.29 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.30 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
| STR rx085enumAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.31 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.32 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
| INT rx085stateFlagAttnSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.33 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.34 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
| STR rx085enumSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.35 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.36 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagSwModeSettingTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.37 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.38 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
| STR rx085enumSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.39 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.40 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
| INT rx085stateFlagSwModeThresholdTwo | 1.3.6.1.4.1.1166.6.1.2.32.3.2.41 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelModeThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.42 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
| STR rx085enumModeThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.43 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueModeThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.44 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagModeThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.45 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.46 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
| STR rx085enumWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.47 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.48 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagWavelengthThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.49 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.50 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
| STR rx085enumAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.51 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.52 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
| INT rx085stateFlagAttnSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.53 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.54 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
| STR rx085enumSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.55 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.56 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagSwModeSettingThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.57 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.58 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
| STR rx085enumSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.59 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.60 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
| INT rx085stateFlagSwModeThresholdThree | 1.3.6.1.4.1.1166.6.1.2.32.3.2.61 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelModeFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.62 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Mode Digital parameter. |
| STR rx085enumModeFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.63 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueModeFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.64 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagModeFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.65 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.66 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter. |
| STR rx085enumWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.67 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.68 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagWavelengthFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.69 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.70 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter. |
| STR rx085enumAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.71 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.72 | INTEGER | read-write | The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db |
| INT rx085stateFlagAttnSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.73 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.74 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter. |
| STR rx085enumSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.75 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.76 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagSwModeSettingFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.77 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.78 | DisplayString | read-only | The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter. |
| STR rx085enumSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.79 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.80 | INTEGER | read-write | The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db |
| INT rx085stateFlagSwModeThresholdFour | 1.3.6.1.4.1.1166.6.1.2.32.3.2.81 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelModuleConfig | 1.3.6.1.4.1.1166.6.1.2.32.3.2.82 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR rx085enumModuleConfig | 1.3.6.1.4.1.1166.6.1.2.32.3.2.83 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueModuleConfig | 1.3.6.1.4.1.1166.6.1.2.32.3.2.84 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagModuleConfig | 1.3.6.1.4.1.1166.6.1.2.32.3.2.85 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelRevertTime | 1.3.6.1.4.1.1166.6.1.2.32.3.2.86 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR rx085enumRevertTime | 1.3.6.1.4.1.1166.6.1.2.32.3.2.87 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueRevertTime | 1.3.6.1.4.1.1166.6.1.2.32.3.2.88 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagRevertTime | 1.3.6.1.4.1.1166.6.1.2.32.3.2.89 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.32.3.2.90 | DisplayString | read-only | The value of this object provides the label of the Test point Select Digital parameter. |
| STR rx085enumTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.32.3.2.91 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.32.3.2.92 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagTestPointSelect | 1.3.6.1.4.1.1166.6.1.2.32.3.2.93 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.32.3.2.94 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR rx085enumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.32.3.2.95 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT rx085valueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.32.3.2.96 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT rx085stateFlagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.32.3.2.97 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Rx085BX4StatusTable | 1.3.6.1.4.1.1166.6.1.2.32.4 | not-accessible | This table contains gx2Rx085BX4 specific parameters with nominal and current values. | |
| gx2Rx085BX4StatusEntry | 1.3.6.1.4.1.1166.6.1.2.32.4.3 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Rx085BX4StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.32.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR rx085labelBoot | 1.3.6.1.4.1.1166.6.1.2.32.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT rx085valueBoot | 1.3.6.1.4.1.1166.6.1.2.32.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagBoot | 1.3.6.1.4.1.1166.6.1.2.32.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelFlash | 1.3.6.1.4.1.1166.6.1.2.32.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT rx085valueFlash | 1.3.6.1.4.1.1166.6.1.2.32.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagFlash | 1.3.6.1.4.1.1166.6.1.2.32.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT rx085valueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Alarm Data CRC Status parameter. |
| INT rx085valueAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagAlarmDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Calibration Data CRC Status parameter. |
| INT rx085valueCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagCalibrationDataCRC | 1.3.6.1.4.1.1166.6.1.2.32.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelHW | 1.3.6.1.4.1.1166.6.1.2.32.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Hardware Status parameter. |
| INT rx085valueHW | 1.3.6.1.4.1.1166.6.1.2.32.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagHW | 1.3.6.1.4.1.1166.6.1.2.32.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelOptSigOne | 1.3.6.1.4.1.1166.6.1.2.32.4.3.20 | DisplayString | read-only | The value of this object provides the label of the Optical Signal Status parameter. |
| INT rx085valueOptSigOne | 1.3.6.1.4.1.1166.6.1.2.32.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagOptSigOne | 1.3.6.1.4.1.1166.6.1.2.32.4.3.22 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelOptSigTwo | 1.3.6.1.4.1.1166.6.1.2.32.4.3.23 | DisplayString | read-only | The value of this object provides the label of the Optical Signal Status parameter. |
| INT rx085valueOptSigTwo | 1.3.6.1.4.1.1166.6.1.2.32.4.3.24 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagOptSigTwo | 1.3.6.1.4.1.1166.6.1.2.32.4.3.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelOptSigThree | 1.3.6.1.4.1.1166.6.1.2.32.4.3.26 | DisplayString | read-only | The value of this object provides the label of the Optical Signal Status parameter. |
| INT rx085valueOptSigThree | 1.3.6.1.4.1.1166.6.1.2.32.4.3.27 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagOptSigThree | 1.3.6.1.4.1.1166.6.1.2.32.4.3.28 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelOptSigFour | 1.3.6.1.4.1.1166.6.1.2.32.4.3.29 | DisplayString | read-only | The value of this object provides the label of the Optical Signal Status parameter. |
| INT rx085valueOptSigFour | 1.3.6.1.4.1.1166.6.1.2.32.4.3.30 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagOptSigFour | 1.3.6.1.4.1.1166.6.1.2.32.4.3.31 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR rx085labelBackupCable | 1.3.6.1.4.1.1166.6.1.2.32.4.3.32 | DisplayString | read-only | The value of this object provides the label of the Backup Cable Status parameter. |
| INT rx085valueBackupCable | 1.3.6.1.4.1.1166.6.1.2.32.4.3.33 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT rx085stateflagBackupCable | 1.3.6.1.4.1.1166.6.1.2.32.4.3.34 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2Rx085BX4FactoryTable | 1.3.6.1.4.1.1166.6.1.2.32.5 | not-accessible | This table contains gx2Rx085BX4 specific parameters with nominal and current values. | |
| gx2Rx085BX4FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.32.5.4 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Rx085BX4FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.32.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT rx085bootControlByte | 1.3.6.1.4.1.1166.6.1.2.32.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT rx085bootStatusByte | 1.3.6.1.4.1.1166.6.1.2.32.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT rx085bank0CRC | 1.3.6.1.4.1.1166.6.1.2.32.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT rx085bank1CRC | 1.3.6.1.4.1.1166.6.1.2.32.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT rx085prgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.32.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT rx085factoryCRC | 1.3.6.1.4.1.1166.6.1.2.32.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT rx085calculateCRC | 1.3.6.1.4.1.1166.6.1.2.32.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT rx085hourMeter | 1.3.6.1.4.1.1166.6.1.2.32.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT rx085flashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.32.5.4.10 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side A. |
| INT rx085flashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.32.5.4.11 | INTEGER | read-only | This object provides the number of times the flash has been programmed on side B. |
| STR rx085fwRev0 | 1.3.6.1.4.1.1166.6.1.2.32.5.4.12 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 0. |
| STR rx085fwRev1 | 1.3.6.1.4.1.1166.6.1.2.32.5.4.13 | DisplayString | read-only | This object provides the Revision of the firmware stores in bank 1. |
RFC description
Management for OMNISTAR Quad high-density return path receiver modules in HFC networks.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 RX085BX4 85 MHz quad-port optical receiver card) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.