OMNI-gx2Rx085BX4-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2Rx085BX4 FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "1" Oct 3, 2007 Initial Release --REVISION "2" May 5, 2009 Adds Burst mode to Module configuration OID --REVISION "3" Sept 10, 2009 Adds Optical power bad traps --DESCRIPTION -- Initial revision derived from RX085BX2 -- OMNISTAR Quad (High Density) Return Path Receiver Module MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2Rx085BX4 Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Rx085BX4 device type. -- These parameters are common across all network elements -- from gx2Rx085BX4 device type. -- -- The gx2Rx085BX4 Network Elements subgroup is -- a list of gx2Rx085BX4 type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Rx085BX4TableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Rx085BX4 type. -- -- Both groups are mandatory for management of gx2Rx085BX4 devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) U32Data ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2Rx085BX4 Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Rx085BX4 device type. -- These parameters are common across all network elements -- from gx2Rx085BX4 device type. gx2Rx085BX4Descriptor OBJECT IDENTIFIER ::= {gx2Rx085BX4 1} --***************************************************************************** -- gx2Rx085BX4 Table -- Contains a list of all gx2Rx085BX4 type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Rx085BX4TableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2Rx085BX4 type. gx2Rx085BX4AnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx085BX4AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx085BX4 specific parameters with nominal and current values." ::= { gx2Rx085BX4 2 } gx2Rx085BX4AnalogEntry OBJECT-TYPE SYNTAX Gx2Rx085BX4AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Rx085BX4AnalogTableIndex } ::= { gx2Rx085BX4AnalogTable 1} --*********************************************************************** gx2Rx085BX4DigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx085BX4DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx085BX4 specific parameters with nominal and current values." ::= { gx2Rx085BX4 3 } gx2Rx085BX4DigitalEntry OBJECT-TYPE SYNTAX Gx2Rx085BX4DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Rx085BX4DigitalTableIndex } ::= { gx2Rx085BX4DigitalTable 2} --*********************************************************************** gx2Rx085BX4StatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx085BX4StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx085BX4 specific parameters with nominal and current values." ::= { gx2Rx085BX4 4 } gx2Rx085BX4StatusEntry OBJECT-TYPE SYNTAX Gx2Rx085BX4StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Rx085BX4StatusTableIndex } ::= { gx2Rx085BX4StatusTable 3} --*********************************************************************** gx2Rx085BX4FactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rx085BX4FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rx085BX4 specific parameters with nominal and current values." ::= { gx2Rx085BX4 5 } gx2Rx085BX4FactoryEntry OBJECT-TYPE SYNTAX Gx2Rx085BX4FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Rx085BX4FactoryTableIndex } ::= { gx2Rx085BX4FactoryTable 4} --*********************************************************************** --MM Rx085BX4AnalogTableIndex Gx2Rx085BX4AnalogEntry ::= SEQUENCE { gx2Rx085BX4AnalogTableIndex INTEGER, -- Analog Parameters rx085labelOptPowerOne DisplayString (SIZE (0..80)), rx085uomOptPowerOne DisplayString (SIZE (0..80)), rx085majorHighOptPowerOne Float, rx085majorLowOptPowerOne Float, rx085minorHighOptPowerOne Float, rx085minorLowOptPowerOne Float, rx085currentValueOptPowerOne Float, rx085stateFlagOptPowerOne INTEGER, rx085minValueOptPowerOne Float, rx085maxValueOptPowerOne Float, rx085alarmStateOptPowerOne INTEGER, rx085labelOptPowerTwo DisplayString (SIZE (0..80)), rx085uomOptPowerTwo DisplayString (SIZE (0..80)), rx085majorHighOptPowerTwo Float, rx085majorLowOptPowerTwo Float, rx085minorHighOptPowerTwo Float, rx085minorLowOptPowerTwo Float, rx085currentValueOptPowerTwo Float, rx085stateFlagOptPowerTwo INTEGER, rx085minValueOptPowerTwo Float, rx085maxValueOptPowerTwo Float, rx085alarmStateOptPowerTwo INTEGER, rx085labelOptPowerThree DisplayString (SIZE (0..80)), rx085uomOptPowerThree DisplayString (SIZE (0..80)), rx085majorHighOptPowerThree Float, rx085majorLowOptPowerThree Float, rx085minorHighOptPowerThree Float, rx085minorLowOptPowerThree Float, rx085currentValueOptPowerThree Float, rx085stateFlagOptPowerThree INTEGER, rx085minValueOptPowerThree Float, rx085maxValueOptPowerThree Float, rx085alarmStateOptPowerThree INTEGER, rx085labelOptPowerFour DisplayString (SIZE (0..80)), rx085uomOptPowerFour DisplayString (SIZE (0..80)), rx085majorHighOptPowerFour Float, rx085majorLowOptPowerFour Float, rx085minorHighOptPowerFour Float, rx085minorLowOptPowerFour Float, rx085currentValueOptPowerFour Float, rx085stateFlagOptPowerFour INTEGER, rx085minValueOptPowerFour Float, rx085maxValueOptPowerFour Float, rx085alarmStateOptPowerFour INTEGER, rx085labelModTemp DisplayString (SIZE (0..80)), rx085uomModTemp DisplayString (SIZE (0..80)), rx085majorHighModTemp Float, rx085majorLowModTemp Float, rx085minorHighModTemp Float, rx085minorLowModTemp Float, rx085currentValueModTemp Float, rx085stateFlagModTemp INTEGER, rx085minValueModTemp Float, rx085maxValueModTemp Float, rx085alarmStateModTemp INTEGER, rx085labelFanCurrent DisplayString (SIZE (0..80)), rx085uomFanCurrent DisplayString (SIZE (0..80)), rx085majorHighFanCurrent Float, rx085majorLowFanCurrent Float, rx085minorHighFanCurrent Float, rx085minorLowFanCurrent Float, rx085currentValueFanCurrent Float, rx085stateFlagFanCurrent INTEGER, rx085minValueFanCurrent Float, rx085maxValueFanCurrent Float, rx085alarmStateFanCurrent INTEGER, rx085label12Volt DisplayString (SIZE (0..80)), rx085uom12Volt DisplayString (SIZE (0..80)), rx085majorHigh12Volt Float, rx085majorLow12Volt Float, rx085minorHigh12Volt Float, rx085minorLow12Volt Float, rx085currentValue12Volt Float, rx085stateFlag12Volt INTEGER, rx085minValue12Volt Float, rx085maxValue12Volt Float, rx085alarmState12Volt INTEGER } -- **************** Digital Parameters *********************** Gx2Rx085BX4DigitalEntry ::= SEQUENCE { gx2Rx085BX4DigitalTableIndex INTEGER, rx085labelModeOne DisplayString (SIZE (0..80)), rx085valueModeOne INTEGER, rx085enumModeOne DisplayString (SIZE (0..80)), rx085stateFlagModeOne INTEGER, rx085labelWavelengthOne DisplayString (SIZE (0..80)), rx085valueWavelengthOne INTEGER, rx085enumWavelengthOne DisplayString (SIZE (0..80)), rx085stateFlagWavelengthOne INTEGER, rx085labelAttnSettingOne DisplayString (SIZE (0..80)), rx085valueAttnSettingOne INTEGER, rx085enumAttnSettingOne DisplayString (SIZE (0..80)), rx085stateFlagAttnSettingOne INTEGER, rx085labelSwModeSettingOne DisplayString (SIZE (0..80)), rx085valueSwModeSettingOne INTEGER, rx085enumSwModeSettingOne DisplayString (SIZE (0..80)), rx085stateFlagSwModeSettingOne INTEGER, rx085labelSwModeThresholdOne DisplayString (SIZE (0..80)), rx085valueSwModeThresholdOne INTEGER, rx085enumSwModeThresholdOne DisplayString (SIZE (0..80)), rx085stateFlagSwModeThresholdOne INTEGER, rx085labelModeTwo DisplayString (SIZE (0..80)), rx085valueModeTwo INTEGER, rx085enumModeTwo DisplayString (SIZE (0..80)), rx085stateFlagModeTwo INTEGER, rx085labelWavelengthTwo DisplayString (SIZE (0..80)), rx085valueWavelengthTwo INTEGER, rx085enumWavelengthTwo DisplayString (SIZE (0..80)), rx085stateFlagWavelengthTwo INTEGER, rx085labelAttnSettingTwo DisplayString (SIZE (0..80)), rx085valueAttnSettingTwo INTEGER, rx085enumAttnSettingTwo DisplayString (SIZE (0..80)), rx085stateFlagAttnSettingTwo INTEGER, rx085labelSwModeSettingTwo DisplayString (SIZE (0..80)), rx085valueSwModeSettingTwo INTEGER, rx085enumSwModeSettingTwo DisplayString (SIZE (0..80)), rx085stateFlagSwModeSettingTwo INTEGER, rx085labelSwModeThresholdTwo DisplayString (SIZE (0..80)), rx085valueSwModeThresholdTwo INTEGER, rx085enumSwModeThresholdTwo DisplayString (SIZE (0..80)), rx085stateFlagSwModeThresholdTwo INTEGER, rx085labelModeThree DisplayString (SIZE (0..80)), rx085valueModeThree INTEGER, rx085enumModeThree DisplayString (SIZE (0..80)), rx085stateFlagModeThree INTEGER, rx085labelWavelengthThree DisplayString (SIZE (0..80)), rx085valueWavelengthThree INTEGER, rx085enumWavelengthThree DisplayString (SIZE (0..80)), rx085stateFlagWavelengthThree INTEGER, rx085labelAttnSettingThree DisplayString (SIZE (0..80)), rx085valueAttnSettingThree INTEGER, rx085enumAttnSettingThree DisplayString (SIZE (0..80)), rx085stateFlagAttnSettingThree INTEGER, rx085labelSwModeSettingThree DisplayString (SIZE (0..80)), rx085valueSwModeSettingThree INTEGER, rx085enumSwModeSettingThree DisplayString (SIZE (0..80)), rx085stateFlagSwModeSettingThree INTEGER, rx085labelSwModeThresholdThree DisplayString (SIZE (0..80)), rx085valueSwModeThresholdThree INTEGER, rx085enumSwModeThresholdThree DisplayString (SIZE (0..80)), rx085stateFlagSwModeThresholdThree INTEGER, rx085labelModeFour DisplayString (SIZE (0..80)), rx085valueModeFour INTEGER, rx085enumModeFour DisplayString (SIZE (0..80)), rx085stateFlagModeFour INTEGER, rx085labelWavelengthFour DisplayString (SIZE (0..80)), rx085valueWavelengthFour INTEGER, rx085enumWavelengthFour DisplayString (SIZE (0..80)), rx085stateFlagWavelengthFour INTEGER, rx085labelAttnSettingFour DisplayString (SIZE (0..80)), rx085valueAttnSettingFour INTEGER, rx085enumAttnSettingFour DisplayString (SIZE (0..80)), rx085stateFlagAttnSettingFour INTEGER, rx085labelSwModeSettingFour DisplayString (SIZE (0..80)), rx085valueSwModeSettingFour INTEGER, rx085enumSwModeSettingFour DisplayString (SIZE (0..80)), rx085stateFlagSwModeSettingFour INTEGER, rx085labelSwModeThresholdFour DisplayString (SIZE (0..80)), rx085valueSwModeThresholdFour INTEGER, rx085enumSwModeThresholdFour DisplayString (SIZE (0..80)), rx085stateFlagSwModeThresholdFour INTEGER, rx085labelModuleConfig DisplayString (SIZE (0..80)), rx085valueModuleConfig INTEGER, rx085enumModuleConfig DisplayString (SIZE (0..80)), rx085stateFlagModuleConfig INTEGER, rx085labelRevertTime DisplayString (SIZE (0..80)), rx085valueRevertTime INTEGER, rx085enumRevertTime DisplayString (SIZE (0..80)), rx085stateFlagRevertTime INTEGER, rx085labelTestPointSelect DisplayString (SIZE (0..80)), rx085valueTestPointSelect INTEGER, rx085enumTestPointSelect DisplayString (SIZE (0..80)), rx085stateFlagTestPointSelect INTEGER, rx085labelFactoryDefault DisplayString (SIZE (0..80)), rx085valueFactoryDefault INTEGER, rx085enumFactoryDefault DisplayString (SIZE (0..80)), rx085stateFlagFactoryDefault INTEGER } -- **************** Status Parameters ************************************ Gx2Rx085BX4StatusEntry ::= SEQUENCE { gx2Rx085BX4StatusTableIndex INTEGER, rx085labelBoot DisplayString (SIZE (0..80)), rx085valueBoot INTEGER, rx085stateflagBoot INTEGER, rx085labelFlash DisplayString (SIZE (0..80)), rx085valueFlash INTEGER, rx085stateflagFlash INTEGER, rx085labelFactoryDataCRC DisplayString (SIZE (0..80)), rx085valueFactoryDataCRC INTEGER, rx085stateflagFactoryDataCRC INTEGER, rx085labelAlarmDataCRC DisplayString (SIZE (0..80)), rx085valueAlarmDataCRC INTEGER, rx085stateflagAlarmDataCRC INTEGER, rx085labelCalibrationDataCRC DisplayString (SIZE (0..80)), rx085valueCalibrationDataCRC INTEGER, rx085stateflagCalibrationDataCRC INTEGER, rx085labelHW DisplayString (SIZE (0..80)), rx085valueHW INTEGER, rx085stateflagHW INTEGER, rx085labelOptSigOne DisplayString (SIZE (0..80)), rx085valueOptSigOne INTEGER, rx085stateflagOptSigOne INTEGER, rx085labelOptSigTwo DisplayString (SIZE (0..80)), rx085valueOptSigTwo INTEGER, rx085stateflagOptSigTwo INTEGER, rx085labelOptSigThree DisplayString (SIZE (0..80)), rx085valueOptSigThree INTEGER, rx085stateflagOptSigThree INTEGER, rx085labelOptSigFour DisplayString (SIZE (0..80)), rx085valueOptSigFour INTEGER, rx085stateflagOptSigFour INTEGER, rx085labelBackupCable DisplayString (SIZE (0..80)), rx085valueBackupCable INTEGER, rx085stateflagBackupCable INTEGER } -- **************** Factory Parameters ************************************* Gx2Rx085BX4FactoryEntry ::= SEQUENCE { gx2Rx085BX4FactoryTableIndex INTEGER, rx085bootControlByte INTEGER, rx085bootStatusByte INTEGER, rx085bank0CRC INTEGER, rx085bank1CRC INTEGER, rx085prgEEPROMByte INTEGER, rx085factoryCRC INTEGER, rx085calculateCRC INTEGER, rx085hourMeter INTEGER, rx085flashPrgCntA INTEGER, rx085flashPrgCntB INTEGER, rx085fwRev0 DisplayString (SIZE (0..80)), rx085fwRev1 DisplayString (SIZE (0..80)) } -- **************** Hold Time Parameters ************************************* -- Gx2Rx085BX4HoldTimeEntry ::= SEQUENCE -- { -- gx2Rx085BX4HoldTimeTableIndex INTEGER, -- gx2Rx085BX4HoldTimeSpecIndex INTEGER, -- gx2Rx085BX4HoldTimeData INTEGER -- } -- -- ************** Analog Parameters **************************** gx2Rx085BX4AnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx085BX4AnalogEntry 1} -- New Parameter rx085labelOptPowerOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 2} rx085uomOptPowerOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 3} rx085majorHighOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 4} rx085majorLowOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 5} rx085minorHighOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 6} rx085minorLowOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 7} rx085currentValueOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 8} rx085stateFlagOptPowerOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4AnalogEntry 9} rx085minValueOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 10} rx085maxValueOptPowerOne OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 11} rx085alarmStateOptPowerOne OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 12} -- New Parameter rx085labelOptPowerTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 13} rx085uomOptPowerTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 14} rx085majorHighOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 15} rx085majorLowOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 16} rx085minorHighOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 17} rx085minorLowOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 18} rx085currentValueOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 19} rx085stateFlagOptPowerTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4AnalogEntry 20} rx085minValueOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 21} rx085maxValueOptPowerTwo OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 22} rx085alarmStateOptPowerTwo OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 23} -- New Parameter rx085labelOptPowerThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 24} rx085uomOptPowerThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 25} rx085majorHighOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 26} rx085majorLowOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 27} rx085minorHighOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 28} rx085minorLowOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 29} rx085currentValueOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 30} rx085stateFlagOptPowerThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4AnalogEntry 31} rx085minValueOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 32} rx085maxValueOptPowerThree OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 33} rx085alarmStateOptPowerThree OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 34} -- New Parameter rx085labelOptPowerFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 35} rx085uomOptPowerFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 36} rx085majorHighOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 37} rx085majorLowOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 38} rx085minorHighOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 39} rx085minorLowOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 40} rx085currentValueOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 41} rx085stateFlagOptPowerFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4AnalogEntry 42} rx085minValueOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 43} rx085maxValueOptPowerFour OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 44} rx085alarmStateOptPowerFour OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2Rx085BX4AnalogEntry 45} -- New Parameter rx085labelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2Rx085BX4AnalogEntry 46} rx085uomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2Rx085BX4AnalogEntry 47} rx085majorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 48} rx085majorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 49} rx085minorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 50} rx085minorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 51} rx085currentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 52} rx085stateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4AnalogEntry 53} rx085minValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 54} rx085maxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 55} rx085alarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2Rx085BX4AnalogEntry 56} -- New Parameter rx085labelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2Rx085BX4AnalogEntry 57} rx085uomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2Rx085BX4AnalogEntry 58} rx085majorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 59} rx085majorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 60} rx085minorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 61} rx085minorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 62} rx085currentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 63} rx085stateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4AnalogEntry 64} rx085minValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 65} rx085maxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 66} rx085alarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2Rx085BX4AnalogEntry 67} -- New Parameter rx085label12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v Current Analog parameter." ::= { gx2Rx085BX4AnalogEntry 68} rx085uom12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2Rx085BX4AnalogEntry 69} rx085majorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 70} rx085majorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 71} rx085minorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 72} rx085minorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 73} rx085currentValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 74} rx085stateFlag12Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4AnalogEntry 75} rx085minValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 76} rx085maxValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Rx085BX4AnalogEntry 77} rx085alarmState12Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v Current Analog parameter." ::= { gx2Rx085BX4AnalogEntry 78} -- ************************ Digital parameters ********************************** gx2Rx085BX4DigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx085BX4DigitalEntry 1} -- New parameter rx085labelModeOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Mode Digital parameter." ::= { gx2Rx085BX4DigitalEntry 2} rx085enumModeOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 3} rx085valueModeOne OBJECT-TYPE SYNTAX INTEGER { off(1), manual(2), agc(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 4} rx085stateFlagModeOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 5} -- New parameter rx085labelWavelengthOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter." ::= { gx2Rx085BX4DigitalEntry 6} rx085enumWavelengthOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 7} rx085valueWavelengthOne OBJECT-TYPE SYNTAX INTEGER { nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 8} rx085stateFlagWavelengthOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 9} -- New parameter rx085labelAttnSettingOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter." ::= { gx2Rx085BX4DigitalEntry 10} rx085enumAttnSettingOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 11} rx085valueAttnSettingOne OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 60. Each increment represents 1/2 dB of attenuation from 0 to 30 dB. Where 0 = 0db and 60 = 30db" ::= { gx2Rx085BX4DigitalEntry 12} rx085stateFlagAttnSettingOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 13} -- New parameter rx085labelSwModeSettingOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter." ::= { gx2Rx085BX4DigitalEntry 14} rx085enumSwModeSettingOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 15} rx085valueSwModeSettingOne OBJECT-TYPE SYNTAX INTEGER { off(1), alarm-only(2), alarm-and-switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 16} rx085stateFlagSwModeSettingOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 17} -- New parameter rx085labelSwModeThresholdOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter." ::= { gx2Rx085BX4DigitalEntry 18} rx085enumSwModeThresholdOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 19} rx085valueSwModeThresholdOne OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db" ::= { gx2Rx085BX4DigitalEntry 20} rx085stateFlagSwModeThresholdOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 21} -- New parameter rx085labelModeTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Mode Digital parameter." ::= { gx2Rx085BX4DigitalEntry 22} rx085enumModeTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 23} rx085valueModeTwo OBJECT-TYPE SYNTAX INTEGER { off(1), manual(2), agc(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 24} rx085stateFlagModeTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 25} -- New parameter rx085labelWavelengthTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter." ::= { gx2Rx085BX4DigitalEntry 26} rx085enumWavelengthTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 27} rx085valueWavelengthTwo OBJECT-TYPE SYNTAX INTEGER { nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 28} rx085stateFlagWavelengthTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 29} -- New parameter rx085labelAttnSettingTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter." ::= { gx2Rx085BX4DigitalEntry 30} rx085enumAttnSettingTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 31} rx085valueAttnSettingTwo OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db" ::= { gx2Rx085BX4DigitalEntry 32} rx085stateFlagAttnSettingTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 33} -- New parameter rx085labelSwModeSettingTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter." ::= { gx2Rx085BX4DigitalEntry 34} rx085enumSwModeSettingTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 35} rx085valueSwModeSettingTwo OBJECT-TYPE SYNTAX INTEGER { off(1), alarm-only(2), alarm-and-switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 36} rx085stateFlagSwModeSettingTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 37} -- New parameter rx085labelSwModeThresholdTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter." ::= { gx2Rx085BX4DigitalEntry 38} rx085enumSwModeThresholdTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 39} rx085valueSwModeThresholdTwo OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db" ::= { gx2Rx085BX4DigitalEntry 40} rx085stateFlagSwModeThresholdTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 41} -- New parameter rx085labelModeThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Mode Digital parameter." ::= { gx2Rx085BX4DigitalEntry 42} rx085enumModeThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 43} rx085valueModeThree OBJECT-TYPE SYNTAX INTEGER { off(1), manual(2), agc(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 44} rx085stateFlagModeThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 45} -- New parameter rx085labelWavelengthThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter." ::= { gx2Rx085BX4DigitalEntry 46} rx085enumWavelengthThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 47} rx085valueWavelengthThree OBJECT-TYPE SYNTAX INTEGER { nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 48} rx085stateFlagWavelengthThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 49} -- New parameter rx085labelAttnSettingThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter." ::= { gx2Rx085BX4DigitalEntry 50} rx085enumAttnSettingThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 51} rx085valueAttnSettingThree OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db" ::= { gx2Rx085BX4DigitalEntry 52} rx085stateFlagAttnSettingThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 53} -- New parameter rx085labelSwModeSettingThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter." ::= { gx2Rx085BX4DigitalEntry 54} rx085enumSwModeSettingThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 55} rx085valueSwModeSettingThree OBJECT-TYPE SYNTAX INTEGER { off(1), alarm-only(2), alarm-and-switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 56} rx085stateFlagSwModeSettingThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 57} -- New parameter rx085labelSwModeThresholdThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter." ::= { gx2Rx085BX4DigitalEntry 58} rx085enumSwModeThresholdThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 59} rx085valueSwModeThresholdThree OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db" ::= { gx2Rx085BX4DigitalEntry 60} rx085stateFlagSwModeThresholdThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 61} -- New parameter rx085labelModeFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Mode Digital parameter." ::= { gx2Rx085BX4DigitalEntry 62} rx085enumModeFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 63} rx085valueModeFour OBJECT-TYPE SYNTAX INTEGER { off(1), manual(2), agc(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 64} rx085stateFlagModeFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 65} -- New parameter rx085labelWavelengthFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Wavelength Digital parameter." ::= { gx2Rx085BX4DigitalEntry 66} rx085enumWavelengthFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 67} rx085valueWavelengthFour OBJECT-TYPE SYNTAX INTEGER { nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 68} rx085stateFlagWavelengthFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 69} -- New parameter rx085labelAttnSettingFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's AttnSetting Digital parameter." ::= { gx2Rx085BX4DigitalEntry 70} rx085enumAttnSettingFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 71} rx085valueAttnSettingFour OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db" ::= { gx2Rx085BX4DigitalEntry 72} rx085stateFlagAttnSettingFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 73} -- New parameter rx085labelSwModeSettingFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Switch Mode Setting Digital parameter." ::= { gx2Rx085BX4DigitalEntry 74} rx085enumSwModeSettingFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 75} rx085valueSwModeSettingFour OBJECT-TYPE SYNTAX INTEGER { off(1), alarm-only(2), alarm-and-switch(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 76} rx085stateFlagSwModeSettingFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 77} -- New parameter rx085labelSwModeThresholdFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Rx085BX4's Switch Mode Threshold Digital parameter." ::= { gx2Rx085BX4DigitalEntry 78} rx085enumSwModeThresholdFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 79} rx085valueSwModeThresholdFour OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db" ::= { gx2Rx085BX4DigitalEntry 80} rx085stateFlagSwModeThresholdFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 81} -- New parameter rx085labelModuleConfig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2Rx085BX4DigitalEntry 82} rx085enumModuleConfig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 83} rx085valueModuleConfig OBJECT-TYPE SYNTAX INTEGER { slave(1), master(2), burst(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 84} rx085stateFlagModuleConfig OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 85} -- New parameter rx085labelRevertTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2Rx085BX4DigitalEntry 86} rx085enumRevertTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 87} rx085valueRevertTime OBJECT-TYPE SYNTAX INTEGER { one-sec(1), ten-sec(2), sixty-sec(3), six-hundred-sec(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 88} rx085stateFlagRevertTime OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 89} -- New parameter rx085labelTestPointSelect OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Test point Select Digital parameter." ::= { gx2Rx085BX4DigitalEntry 90} rx085enumTestPointSelect OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 91} rx085valueTestPointSelect OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 92} rx085stateFlagTestPointSelect OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 93} -- New parameter rx085labelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2Rx085BX4DigitalEntry 94} rx085enumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rx085BX4DigitalEntry 95} rx085valueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rx085BX4DigitalEntry 96} rx085stateFlagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4DigitalEntry 97} --*********** STATUS ***************** gx2Rx085BX4StatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx085BX4StatusEntry 1} --New Parameter rx085labelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2Rx085BX4StatusEntry 2} rx085valueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 3} rx085stateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 4} --New Parameter rx085labelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2Rx085BX4StatusEntry 5} rx085valueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 6} rx085stateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 7} --New Parameter rx085labelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2Rx085BX4StatusEntry 8} rx085valueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 9} rx085stateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 10} --New Parameter rx085labelAlarmDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data CRC Status parameter." ::= { gx2Rx085BX4StatusEntry 11} rx085valueAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 12} rx085stateflagAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 13} --New Parameter rx085labelCalibrationDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Calibration Data CRC Status parameter." ::= { gx2Rx085BX4StatusEntry 14} rx085valueCalibrationDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 15} rx085stateflagCalibrationDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 16} --New Parameter rx085labelHW OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Hardware Status parameter." ::= { gx2Rx085BX4StatusEntry 17} rx085valueHW OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 18} rx085stateflagHW OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 19} --New Parameter rx085labelOptSigOne OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Signal Status parameter." ::= { gx2Rx085BX4StatusEntry 20} rx085valueOptSigOne OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 21} rx085stateflagOptSigOne OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 22} --New Parameter rx085labelOptSigTwo OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Signal Status parameter." ::= { gx2Rx085BX4StatusEntry 23} rx085valueOptSigTwo OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 24} rx085stateflagOptSigTwo OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 25} --New Parameter rx085labelOptSigThree OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Signal Status parameter." ::= { gx2Rx085BX4StatusEntry 26} rx085valueOptSigThree OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 27} rx085stateflagOptSigThree OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 28} --New Parameter rx085labelOptSigFour OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Signal Status parameter." ::= { gx2Rx085BX4StatusEntry 29} rx085valueOptSigFour OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 30} rx085stateflagOptSigFour OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 31} --New Parameter rx085labelBackupCable OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Backup Cable Status parameter." ::= { gx2Rx085BX4StatusEntry 32} rx085valueBackupCable OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Rx085BX4StatusEntry 33} rx085stateflagBackupCable OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Rx085BX4StatusEntry 34} -- ************ FACTORY DATA **************** gx2Rx085BX4FactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rx085BX4FactoryEntry 1} rx085bootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2Rx085BX4FactoryEntry 2} rx085bootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2Rx085BX4FactoryEntry 3} rx085bank0CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2Rx085BX4FactoryEntry 4} rx085bank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2Rx085BX4FactoryEntry 5} rx085prgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2Rx085BX4FactoryEntry 6} rx085factoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2Rx085BX4FactoryEntry 7} rx085calculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), calibration(2), alarm(3), tempComp(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated." ::= { gx2Rx085BX4FactoryEntry 8} rx085hourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2Rx085BX4FactoryEntry 9} rx085flashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times the flash has been programmed on side A." ::= { gx2Rx085BX4FactoryEntry 10} rx085flashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times the flash has been programmed on side B." ::= { gx2Rx085BX4FactoryEntry 11} rx085fwRev0 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Revision of the firmware stores in bank 0." ::= { gx2Rx085BX4FactoryEntry 12} rx085fwRev1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the Revision of the firmware stores in bank 1." ::= { gx2Rx085BX4FactoryEntry 13} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** -- ************************************************************************** -- Rx085BX4 Module traps -- ************************************************************************** trapRx085BX4ConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapRx085BX4ConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapRx085BX4OpticalPower1Alarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapRx085BX4OpticalPower2Alarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapRx085BX4OpticalPower3Alarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 5 trapRx085BX4OpticalPower4Alarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 6 trapRx085BX4ModuleTemperatureAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 7 trapRx085BX4FanCurrentAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 8 trapRx085BX4Plus12CurrentAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 9 trapRx085BX4Boot0Alarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 10 trapRx085BX4Boot1Alarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 11 trapRx085BX4FlashAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 12 trapRx085BX4AlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 13 trapRx085BX4FactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 14 trapRx085BX4CalDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 15 trapRx085BX4DefaultAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 16 trapRx085BX4Mode1Alarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 17 trapRx085BX4Mode2Alarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 18 trapRx085BX4Mode3Alarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 19 trapRx085BX4Mode4Alarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 20 trapRx085BX4Output1SwitchedAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 21 trapRx085BX4Output2SwitchedAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 22 trapRx085BX4Output3SwitchedAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 23 trapRx085BX4Output4SwitchedAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Rx085BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 24 trapRx085BX4RX1StatusAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when receiver 1 of the Rx085BX4 Module output is turned on or off." ::= 25 trapRx085BX4RX2StatusAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when receiver 2 of the Rx085BX4 Module output is turned on or off." ::= 26 trapRx085BX4RX3StatusAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when receiver 3 of the Rx085BX4 Module output is turned on or off." ::= 27 trapRx085BX4RX4StatusAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when receiver 4 of the Rx085BX4 Module output is turned on or off." ::= 28 trapRx085BX4BackupCableAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the slave receiver loses connection to the master receiver." ::= 29 trapRx085BX4OptPwr1BadAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the receiver 1 optical power level falls below the user set switching threshold." ::= 30 trapRx085BX4OptPwr2BadAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the receiver 2 optical power level falls below the user set switching threshold." ::= 31 trapRx085BX4OptPwr3BadAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the receiver 3 optical power level falls below the user set switching threshold." ::= 32 trapRx085BX4OptPwr4BadAlarm TRAP-TYPE ENTERPRISE gx2Rx085BX4 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the receiver 4 optical power level falls below the user set switching threshold." ::= 33 END