OMNI-gx2EA1000-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2Ea1000 FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "0" April 26, 2011 --DESCRIPTION -- Added revision and description comment section -- OMNISTAR EM1000 Laser Module (1550nM Forward Path Transmetter) MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2Ea1000E Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Ea1000E device type. -- These parameters are common across all network elements -- from gx2Ea1000 device type. -- -- The gx2Ea1000 Network Elements subgroup is -- a list of gx2Ea1000 type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Ea1000TableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Ea1000 type. -- -- Both groups are mandatory for management of gx2Ea1000 devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. The Floating point number 10,000,000 will -- be used as an out of range or un-used limit indicator. It will be in the -- 32 bit hex representation of the IEE number as follows: 0x501502F9 Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2Ea1000 Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Ea1000 device type. -- These parameters are common across all network elements -- from gx2Ea1000 device type. gx2ea1000Descriptor OBJECT IDENTIFIER ::= {gx2Ea1000 1} --***************************************************************************** -- gx2Ea1000 Table -- Contains a list of all gx2Ea1000 type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2ea1000TableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2Ea1000 type. gx2ea1000AnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2ea1000AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Ea1000 specific parameters with nominal and current values." ::= { gx2Ea1000 2 } gx2ea1000AnalogEntry OBJECT-TYPE SYNTAX Gx2ea1000AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2ea1000AnalogTableIndex } ::= { gx2ea1000AnalogTable 1} --*********************************************************************** gx2ea1000DigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2ea1000DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Ea1000 specific parameters with nominal and current values." ::= { gx2Ea1000 3 } gx2ea1000DigitalEntry OBJECT-TYPE SYNTAX Gx2ea1000DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital parameters and descriptions." INDEX { gx2ea1000DigitalTableIndex } ::= { gx2ea1000DigitalTable 2} --*********************************************************************** gx2ea1000StatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2ea1000StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Ea1000 specific parameters with nominal and current values." ::= { gx2Ea1000 4 } gx2ea1000StatusEntry OBJECT-TYPE SYNTAX Gx2ea1000StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2ea1000StatusTableIndex } ::= { gx2ea1000StatusTable 3} --*********************************************************************** gx2ea1000FactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2ea1000FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Ea1000 specific parameters with nominal and current values." ::= { gx2Ea1000 5 } gx2ea1000FactoryEntry OBJECT-TYPE SYNTAX Gx2ea1000FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory parameters and descriptions." INDEX { gx2ea1000FactoryTableIndex } ::= { gx2ea1000FactoryTable 4} -- **************** Analog Parameters *********************** Gx2ea1000AnalogEntry ::= SEQUENCE { gx2ea1000AnalogTableIndex INTEGER, ea1000labelOffsetNomMonitor DisplayString (SIZE (0..80)), ea1000uomOffsetNomMonitor DisplayString (SIZE (0..80)), ea1000majorHighOffsetNomMonitor Float, ea1000majorLowOffsetNomMonitor Float, ea1000minorHighOffsetNomMonitor Float, ea1000minorLowOffsetNomMonitor Float, ea1000currentValueOffsetNomMonitor Float, ea1000stateFlagOffsetNomMonitor INTEGER, ea1000minValueOffsetNomMonitor Float, ea1000maxValueOffsetNomMonitor Float, ea1000alarmStateOffsetNomMonitor INTEGER, ea1000labelOffsetNomCnt DisplayString (SIZE (0..80)), ea1000uomOffsetNomCnt DisplayString (SIZE (0..80)), ea1000majorHighOffsetNomCnt Float, ea1000majorLowOffsetNomCnt Float, ea1000minorHighOffsetNomCnt Float, ea1000minorLowOffsetNomCnt Float, ea1000currentValueOffsetNomCnt Float, ea1000stateFlagOffsetNomCnt INTEGER, ea1000minValueOffsetNomCnt Float, ea1000maxValueOffsetNomCnt Float, ea1000alarmStateOffsetNomCnt INTEGER, ea1000labelOptPower DisplayString (SIZE (0..80)), ea1000uomOptPower DisplayString (SIZE (0..80)), ea1000majorHighOptPower Float, ea1000majorLowOptPower Float, ea1000minorHighOptPower Float, ea1000minorLowOptPower Float, ea1000currentValueOptPower Float, ea1000stateFlagOptPower INTEGER, ea1000minValueOptPower Float, ea1000maxValueOptPower Float, ea1000alarmStateOptPower INTEGER, ea1000labelLaserTemp DisplayString (SIZE (0..80)), ea1000uomLaserTemp DisplayString (SIZE (0..80)), ea1000majorHighLaserTemp Float, ea1000majorLowLaserTemp Float, ea1000minorHighLaserTemp Float, ea1000minorLowLaserTemp Float, ea1000currentValueLaserTemp Float, ea1000stateFlagLaserTemp INTEGER, ea1000minValueLaserTemp Float, ea1000maxValueLaserTemp Float, ea1000alarmStateLaserTemp INTEGER, ea1000labelLaserBias DisplayString (SIZE (0..80)), ea1000uomLaserBias DisplayString (SIZE (0..80)), ea1000majorHighLaserBias Float, ea1000majorLowLaserBias Float, ea1000minorHighLaserBias Float, ea1000minorLowLaserBias Float, ea1000currentValueLaserBias Float, ea1000stateFlagLaserBias INTEGER, ea1000minValueLaserBias Float, ea1000maxValueLaserBias Float, ea1000alarmStateLaserBias INTEGER, ea1000labelTecCurrent DisplayString (SIZE (0..80)), ea1000uomTecCurrent DisplayString (SIZE (0..80)), ea1000majorHighTecCurrent Float, ea1000majorLowTecCurrent Float, ea1000minorHighTecCurrent Float, ea1000minorLowTecCurrent Float, ea1000currentValueTecCurrent Float, ea1000stateFlagTecCurrent INTEGER, ea1000minValueTecCurrent Float, ea1000maxValueTecCurrent Float, ea1000alarmStateTecCurrent INTEGER, ea1000labelModuleTemp DisplayString (SIZE (0..80)), ea1000uomModuleTemp DisplayString (SIZE (0..80)), ea1000majorHighModuleTemp Float, ea1000majorLowModuleTemp Float, ea1000minorHighModuleTemp Float, ea1000minorLowModuleTemp Float, ea1000currentValueModuleTemp Float, ea1000stateFlagModuleTemp INTEGER, ea1000minValueModuleTemp Float, ea1000maxValueModuleTemp Float, ea1000alarmStateModuleTemp INTEGER, ea1000labelFan1Speed DisplayString (SIZE (0..80)), ea1000uomFan1Speed DisplayString (SIZE (0..80)), ea1000majorHighFan1Speed Float, ea1000majorLowFan1Speed Float, ea1000minorHighFan1Speed Float, ea1000minorLowFan1Speed Float, ea1000currentValueFan1Speed Float, ea1000stateFlagFan1Speed INTEGER, ea1000minValueFan1Speed Float, ea1000maxValueFan1Speed Float, ea1000alarmStateFan1Speed INTEGER, ea1000labelFan2Speed DisplayString (SIZE (0..80)), ea1000uomFan2Speed DisplayString (SIZE (0..80)), ea1000majorHighFan2Speed Float, ea1000majorLowFan2Speed Float, ea1000minorHighFan2Speed Float, ea1000minorLowFan2Speed Float, ea1000currentValueFan2Speed Float, ea1000stateFlagFan2Speed INTEGER, ea1000minValueFan2Speed Float, ea1000maxValueFan2Speed Float, ea1000alarmStateFan2Speed INTEGER, ea1000label12Volt DisplayString (SIZE (0..80)), ea1000uom12Volt DisplayString (SIZE (0..80)), ea1000majorHigh12Volt Float, ea1000majorLow12Volt Float, ea1000minorHigh12Volt Float, ea1000minorLow12Volt Float, ea1000currentValue12Volt Float, ea1000stateFlag12Volt INTEGER, ea1000minValue12Volt Float, ea1000maxValue12Volt Float, ea1000alarmState12Volt INTEGER } -- **************** Digital Parameters *********************** Gx2ea1000DigitalEntry ::= SEQUENCE { gx2ea1000DigitalTableIndex INTEGER, ea1000labelRfInput DisplayString (SIZE (0..80)), ea1000enumRfInput DisplayString (SIZE (0..80)), ea1000valueRfInput INTEGER, ea1000stateflagRfInput INTEGER, ea1000labelOptOutput DisplayString (SIZE (0..80)), ea1000enumOptOutput DisplayString (SIZE (0..80)), ea1000valueOptOutput INTEGER, ea1000stateflagOptOutput INTEGER, ea1000labelLaserMode DisplayString (SIZE (0..80)), ea1000enumLaserMode DisplayString (SIZE (0..80)), ea1000valueLaserMode INTEGER, ea1000stateflagLaserMode INTEGER, ea1000labelAttenSetting DisplayString (SIZE (0..80)), ea1000enumAttenSetting DisplayString (SIZE (0..80)), ea1000valueAttenSetting INTEGER, ea1000stateflagAttenSetting INTEGER, ea1000labelLaserSecMode DisplayString (SIZE (0..80)), ea1000enumLaserSecMode DisplayString (SIZE (0..80)), ea1000valueLaserSecMode INTEGER, ea1000stateflagLaserSecMode INTEGER, ea1000labelVideoOffset DisplayString (SIZE (0..80)), ea1000enumVideoOffset DisplayString (SIZE (0..80)), ea1000valueVideoOffset INTEGER, ea1000stateflagVideoOffset INTEGER, ea1000labelFactoryDefault DisplayString (SIZE (0..80)), ea1000enumFactoryDefault DisplayString (SIZE (0..80)), ea1000valueFactoryDefault INTEGER, ea1000stateflagFactoryDefault INTEGER } -- **************** Status Parameters ************************************ Gx2ea1000StatusEntry ::= SEQUENCE { gx2ea1000StatusTableIndex INTEGER, ea1000labelBoot DisplayString (SIZE (0..80)), ea1000valueBoot INTEGER, ea1000stateflagBoot INTEGER, ea1000labelFlash DisplayString (SIZE (0..80)), ea1000valueFlash INTEGER, ea1000stateflagFlash INTEGER, ea1000labelFactoryDataCRC DisplayString (SIZE (0..80)), ea1000valueFactoryDataCRC INTEGER, ea1000stateflagFactoryDataCRC INTEGER, ea1000labelLaserDataCRC DisplayString (SIZE (0..80)), ea1000valueLaserDataCRC INTEGER, ea1000stateflagLaserDataCRC INTEGER, ea1000labelAlarmDataCrc DisplayString (SIZE (0..80)), ea1000valueAlarmDataCrc INTEGER, ea1000stateflagAlarmDataCrc INTEGER, ea1000labelRFInputStatus DisplayString (SIZE (0..80)), ea1000valueRFInputStatus INTEGER, ea1000stateflagRFInputStatus INTEGER } -- **************** Factory Parameters ************************************* Gx2ea1000FactoryEntry ::= SEQUENCE { gx2ea1000FactoryTableIndex INTEGER, ea1000bootControlByteValue INTEGER, ea1000bootStatusByteValue INTEGER, ea1000bank1CRCValue INTEGER, ea1000bank2CRCValue INTEGER, ea1000prgEEPROMByteValue INTEGER, ea1000factoryCRCValue INTEGER, ea1000calculateCRCValue INTEGER, ea1000hourMeterValue INTEGER, ea1000flashPrgCntAValue INTEGER, ea1000flashPrgCntBValue INTEGER, ea1000flashBankARevValue DisplayString (SIZE (0..80)), ea1000flashBankBRevValue DisplayString (SIZE (0..80)) } -- ************** Analog Parameters **************************** gx2ea1000AnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2ea1000AnalogEntry 1} -- New Parameter ea1000labelOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Monitor Analog parameter." ::= { gx2ea1000AnalogEntry 2} ea1000uomOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter." ::= { gx2ea1000AnalogEntry 3} ea1000majorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 4} ea1000majorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 5} ea1000minorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 6} ea1000minorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 7} ea1000currentValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 8} ea1000stateFlagOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)" ::= { gx2ea1000AnalogEntry 9} ea1000minValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 10} ea1000maxValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 11} ea1000alarmStateOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Offset Monitor Analog parameter." ::= { gx2ea1000AnalogEntry 12} -- New Parameter ea1000labelOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Control Analog parameter." ::= { gx2ea1000AnalogEntry 13} ea1000uomOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Control Analog parameter." ::= { gx2ea1000AnalogEntry 14} ea1000majorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 15} ea1000majorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 16} ea1000minorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 17} ea1000minorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 18} ea1000currentValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 19} ea1000stateFlagOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)" ::= { gx2ea1000AnalogEntry 20} ea1000minValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 21} ea1000maxValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 22} ea1000alarmStateOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Offset Control Analog parameter." ::= { gx2ea1000AnalogEntry 23} -- New Parameter ea1000labelOptPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2ea1000AnalogEntry 24} ea1000uomOptPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2ea1000AnalogEntry 25} ea1000majorHighOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 26} ea1000majorLowOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 27} ea1000minorHighOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 28} ea1000minorLowOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 29} ea1000currentValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 30} ea1000stateFlagOptPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000AnalogEntry 31} ea1000minValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 32} ea1000maxValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 33} ea1000alarmStateOptPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2ea1000AnalogEntry 34} -- New Parameter ea1000labelLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Temperature Analog parameter." ::= { gx2ea1000AnalogEntry 35} ea1000uomLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter." ::= { gx2ea1000AnalogEntry 36} ea1000majorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 37} ea1000majorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 38} ea1000minorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 39} ea1000minorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 40} ea1000currentValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 41} ea1000stateFlagLaserTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000AnalogEntry 42} ea1000minValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 43} ea1000maxValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 44} ea1000alarmStateLaserTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Temperature Analog parameter." ::= { gx2ea1000AnalogEntry 45} -- New Parameter ea1000labelLaserBias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Bias Current Analog parameter." ::= { gx2ea1000AnalogEntry 46} ea1000uomLaserBias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Bias Analog parameter." ::= { gx2ea1000AnalogEntry 47} ea1000majorHighLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 48} ea1000majorLowLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 49} ea1000minorHighLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 50} ea1000minorLowLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 51} ea1000currentValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 52} ea1000stateFlagLaserBias OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000AnalogEntry 53} ea1000minValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 54} ea1000maxValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 55} ea1000alarmStateLaserBias OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Bias Analog parameter." ::= { gx2ea1000AnalogEntry 56} -- New Parameter ea1000labelTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Current Analog parameter." ::= { gx2ea1000AnalogEntry 57} ea1000uomTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Current Analog parameter.." ::= { gx2ea1000AnalogEntry 58} ea1000majorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 59} ea1000majorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 60} ea1000minorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 61} ea1000minorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 62} ea1000currentValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 63} ea1000stateFlagTecCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000AnalogEntry 64} ea1000minValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 65} ea1000maxValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 66} ea1000alarmStateTecCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Current Analog parameter." ::= { gx2ea1000AnalogEntry 67} -- New Parameter ea1000labelModuleTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2ea1000AnalogEntry 68} ea1000uomModuleTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2ea1000AnalogEntry 69} ea1000majorHighModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 70} ea1000majorLowModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 71} ea1000minorHighModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 72} ea1000minorLowModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 73} ea1000currentValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 74} ea1000stateFlagModuleTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000AnalogEntry 75} ea1000minValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 76} ea1000maxValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 77} ea1000alarmStateModuleTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2ea1000AnalogEntry 78} -- New Parameter ea1000labelFan1Speed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan 1 Speed Analog parameter." ::= { gx2ea1000AnalogEntry 79} ea1000uomFan1Speed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan 1 Speed Analog parameter." ::= { gx2ea1000AnalogEntry 80} ea1000majorHighFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Major High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 81} ea1000majorLowFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 82} ea1000minorHighFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 83} ea1000minorLowFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 84} ea1000currentValueFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 85} ea1000stateFlagFan1Speed OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan 1 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000AnalogEntry 86} ea1000minValueFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 87} ea1000maxValueFan1Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 88} ea1000alarmStateFan1Speed OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan 1 Speed Analog parameter." ::= { gx2ea1000AnalogEntry 89 } -- New Parameter ea1000labelFan2Speed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan 2 Speed Analog parameter." ::= { gx2ea1000AnalogEntry 90 } ea1000uomFan2Speed OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan 2 Speed Analog parameter." ::= { gx2ea1000AnalogEntry 91 } ea1000majorHighFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Major High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 92 } ea1000majorLowFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 93 } ea1000minorHighFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)" ::= { gx2ea1000AnalogEntry 94 } ea1000minorLowFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 95 } ea1000currentValueFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 96 } ea1000stateFlagFan2Speed OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan 2 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000AnalogEntry 97 } ea1000minValueFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 98 } ea1000maxValueFan2Speed OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 99 } ea1000alarmStateFan2Speed OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan 2 Speed Analog parameter." ::= { gx2ea1000AnalogEntry 100} -- New Parameter ea1000label12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v Current Analog parameter." ::= { gx2ea1000AnalogEntry 101} ea1000uom12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2ea1000AnalogEntry 102} ea1000majorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 103} ea1000majorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 104} ea1000minorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 105} ea1000minorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 106} ea1000currentValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 107} ea1000stateFlag12Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000AnalogEntry 108} ea1000minValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 109} ea1000maxValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2ea1000AnalogEntry 110} ea1000alarmState12Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v Current Analog parameter." ::= { gx2ea1000AnalogEntry 111} -- ************************ Digital parameters ********************************** gx2ea1000DigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2ea1000DigitalEntry 1} -- New parameter ea1000labelRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Input Control Digital parameter." ::= { gx2ea1000DigitalEntry 2} ea1000enumRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2ea1000DigitalEntry 3} ea1000valueRfInput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2ea1000DigitalEntry 4} ea1000stateflagRfInput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000DigitalEntry 5} -- New parameter ea1000labelOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Output Control Digital parameter." ::= { gx2ea1000DigitalEntry 6} ea1000enumOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2ea1000DigitalEntry 7} ea1000valueOptOutput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2ea1000DigitalEntry 8} ea1000stateflagOptOutput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the ea1000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000DigitalEntry 9} -- New parameter ea1000labelLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Mode Digital parameter." ::= { gx2ea1000DigitalEntry 10} ea1000enumLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2ea1000DigitalEntry 11} ea1000valueLaserMode OBJECT-TYPE SYNTAX INTEGER { preset(1), set(2), setEquate(3), manual(4), manualEquate(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2ea1000DigitalEntry 12} ea1000stateflagLaserMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000DigitalEntry 13} -- New parameter ea1000labelAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Attenuation Setting Ditital Parameter." ::= { gx2ea1000DigitalEntry 14} ea1000enumAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2ea1000DigitalEntry 15} ea1000valueAttenSetting OBJECT-TYPE SYNTAX INTEGER { attn0pt0(1), attn0pt5(2), attn1pt0(3), attn1pt5(4), attn2pt0(5), attn2pt5(6), attn3pt0(7), attn3pt5(8), attn4pt0(9), attn4pt5(10), attn5pt0(11), attn5pt5(12), attn6pt0(13), attn6pt5(14), attn7pt0(15), attn7pt5(16), attn8pt0(17), attn8pt5(18), attn9pt0(19), attn9pt5(20), attn10pt0(21), attn10pt5(22), attn11pt0(23), attn11pt5(24), attn12pt0(25) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2ea1000DigitalEntry 16} ea1000stateflagAttenSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000DigitalEntry 17} -- New parameter ea1000labelLaserSecMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Secondary Mode Digital parameter." ::= { gx2ea1000DigitalEntry 18} ea1000enumLaserSecMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2ea1000DigitalEntry 19} ea1000valueLaserSecMode OBJECT-TYPE SYNTAX INTEGER { cw(1), video(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2ea1000DigitalEntry 20} ea1000stateflagLaserSecMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000DigitalEntry 21} -- New parameter ea1000labelVideoOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Video Offset Digital parameter." ::= { gx2ea1000DigitalEntry 22} ea1000enumVideoOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.." ::= { gx2ea1000DigitalEntry 23} ea1000valueVideoOffset OBJECT-TYPE SYNTAX INTEGER { minus1dB(1), minus2dB(2), minus3dB(3), minus4dB(4), minus5dB(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2ea1000DigitalEntry 24} ea1000stateflagVideoOffset OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000DigitalEntry 25} -- New parameter ea1000labelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2ea1000DigitalEntry 26} ea1000enumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2ea1000DigitalEntry 27} ea1000valueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2ea1000DigitalEntry 28} ea1000stateflagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000DigitalEntry 29} --*********** STATUS ***************** gx2ea1000StatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2ea1000StatusEntry 1} --New Parameter ea1000labelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2ea1000StatusEntry 2} ea1000valueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2ea1000StatusEntry 3} ea1000stateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000StatusEntry 4} --New Parameter ea1000labelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2ea1000StatusEntry 5} ea1000valueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2ea1000StatusEntry 6} ea1000stateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000StatusEntry 7} --New Parameter ea1000labelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2ea1000StatusEntry 8} ea1000valueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2ea1000StatusEntry 9} ea1000stateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000StatusEntry 10} --New Parameter ea1000labelLaserDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Data CRC Status parameter." ::= { gx2ea1000StatusEntry 11} ea1000valueLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2ea1000StatusEntry 12} ea1000stateflagLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000StatusEntry 13} --New Parameter ea1000labelAlarmDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2ea1000StatusEntry 14} ea1000valueAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2ea1000StatusEntry 15} ea1000stateflagAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000StatusEntry 16} --New Parameter ea1000labelRFInputStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Input Status parameter." ::= { gx2ea1000StatusEntry 17} ea1000valueRFInputStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2ea1000StatusEntry 18} ea1000stateflagRFInputStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2ea1000StatusEntry 19} -- ************ FACTORY DATA **************** gx2ea1000FactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2ea1000FactoryEntry 1} ea1000bootControlByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2ea1000FactoryEntry 2} ea1000bootStatusByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2ea1000FactoryEntry 3} ea1000bank1CRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2ea1000FactoryEntry 4} ea1000bank2CRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2ea1000FactoryEntry 5} ea1000prgEEPROMByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2ea1000FactoryEntry 6} ea1000factoryCRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2ea1000FactoryEntry 7} ea1000calculateCRCValue OBJECT-TYPE SYNTAX INTEGER { factory(1), laserData(2), alarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated." ::= { gx2ea1000FactoryEntry 8} ea1000hourMeterValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2ea1000FactoryEntry 9} ea1000flashPrgCntAValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2ea1000FactoryEntry 10} ea1000flashPrgCntBValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2ea1000FactoryEntry 11} ea1000flashBankARevValue OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0." ::= { gx2ea1000FactoryEntry 12} ea1000flashBankBRevValue OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1." ::= { gx2ea1000FactoryEntry 13} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** -- ************************************************************************** -- EA 1000 Laser Module traps -- ************************************************************************** trapEA1000ConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapEA1000ConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapEA1000RFInputAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapEA1000RFOverloadAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapEA1000RFOffsetAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 5 trapEA1000OpticalPowerAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 6 trapEA1000LaserBiasAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 7 trapEA1000LaserTempAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 8 trapEA1000TECCurrentAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 9 trapEA1000Fan1SpeedAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Fan 1 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 10 trapEA1000Fan2SpeedAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Fan 2 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 11 trapEA100012vAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 12 trapEA1000ModuleTempAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Module Temperature goes out of range." ::= 13 trapEA1000FlashAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error during Flash memory operations." ::= 14 trapEA1000LaserBiasCntLoopAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation." ::= 15 trapEA1000BankBootAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1." ::= 16 trapEA1000LaserBiasCntLoopInitAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Bias Control loop init fails." ::= 17 trapEA1000RFParamInitAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RF parameter Init fails." ::= 18 trapEA1000TECParamInitAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the TEC Parameter Init fails." ::= 19 trapEA1000AttnTableInitAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Attenuator Table Init fails." ::= 20 trapEA1000PowerMeterTableInitAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Power Meter Table Init fails." ::= 21 trapEA1000LaserDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Data CRC is incorrect." ::= 22 trapEA1000AlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 23 trapEA1000FactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 24 trapEA1000UserRFOffAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the the User RF is turned off." ::= 25 trapEA1000UserOpticalOffAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the User Optical Power is turned off." ::= 26 trapEA1000ResetFactoryDefaultAlarm TRAP-TYPE ENTERPRISE gx2Ea1000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Default Reset occurs." ::= 27 END