OMNI-gx2EA1000-MIB :: ea1000alarmStateLaserBias

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › OMNI-gx2EA1000-MIB › ea1000alarmStateLaserBias

ea1000alarmStateLaserBias

Module: OMNI-gx2EA1000-MIB

OID (symbolic): OMNI-gx2EA1000-MIB::ea1000alarmStateLaserBias

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.33.2.1.56

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The value of this object provides the curent alarm state of the Laser Bias Analog parameter.

What is ea1000alarmStateLaserBias?

This reports the current alarm state of the laser bias current reading: noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), or informational(6). An admin polls this to see at a glance whether the bias current driving the laser diode is currently outside its configured thresholds.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.33.2.1.56
snmpwalk -v2c -c public <target> OMNI-gx2EA1000-MIB::ea1000alarmStateLaserBias

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.33.2.1.56.1
snmpget -v2c -c public <target> OMNI-gx2EA1000-MIB::ea1000alarmStateLaserBias.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EA1000 Ethernet adapter module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2EA1000-MIB::ea1000alarmStateLaserBias OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EA1000 Ethernet adapter module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.33gx2Ea1000GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.33.2gx2ea1000AnalogTableOMNI-gx2EA1000-MIB
1.3.6.1.4.1.1166.6.1.2.33.2.1gx2ea1000AnalogEntryOMNI-gx2EA1000-MIB
1.3.6.1.4.1.1166.6.1.2.33.2.1.56ea1000alarmStateLaserBiasOMNI-gx2EA1000-MIB