All MIBs › OMNI-gx2DM2000-MIB
Category: CATV and HFC
Description: Manages the Cisco/Scientific Atlanta GX2 DM2000 downstream modulator and optical transmitter in HFC cable plants.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2DM2000-MIB?
OMNI-gx2DM2000-MIB is a vendor MIB for the Cisco/Scientific Atlanta GX2 DM2000 downstream modulator, a headend device used in hybrid fiber-coax (HFC) cable television and broadband plants to modulate downstream RF/optical signals. It exposes configuration and status objects specific to the modulator card, such as channel settings, output levels, and module operating state within the GX2 chassis. Its primary monitoring value is hardware health of the modulator module itself, letting operators detect a failed or degraded modulator card, abnormal output power, or a module that has dropped out of the chassis. As part of the broader OMNI-gx2 family of MIBs it shares a common chassis/module management model with sibling GX2 modules (laser, amplifier, switch, attenuator). It is typically deployed in cable headends and hub sites managing HFC optical/RF distribution equipment. Engineers can download the OMNI-gx2DM2000-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2DM2000-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend/optical node (GX2 DM2000 downstream modulator module)
Monitoring Examples
No sample object names were provided for this module, so specific object names cannot be cited here; in practice an operator would poll the modulator's per-slot status and output-level objects within the GX2 chassis management tree. A drop in modulator output level or a change in module operational status would reveal a failing DM2000 card affecting downstream channel delivery. Because it belongs to the OMNI-gx2 module family, it is typically monitored alongside sibling GX2 module MIBs for the same chassis.
What Can Be Monitored
- modulator module operational status
- output signal level
- channel configuration
- module presence in chassis
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Dm2000 | OBJECT-IDENTITY |
From NLS-BBNIDENT-MIB
| gi | OBJECT-IDENTITY |
| motproxies | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress | |
| TimeTicks |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapDM2000ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.34.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapDM2000ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.34.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapDM2000RFInputAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.3 | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM2000RFOverloadAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.4 | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM2000RFOffsetAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.5 | This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM2000OpticalPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.6 | This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM2000LaserBiasAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.7 | This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM2000LaserTempAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.8 | This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM2000TECCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.9 | This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM2000FanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.10 | This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM200012vAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.11 | This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM2000ModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.12 | This trap is issued when the Laser Module Temperature goes out of range. | ||
| NTF trapDM2000FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.13 | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| NTF trapDM2000LaserBiasCntLoopAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.14 | This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation. | ||
| NTF trapDM2000BankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.15 | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| NTF trapDM2000LaserBiasCntLoopInitAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.16 | This trap is issued when the Laser Bias Control loop init fails. | ||
| NTF trapDM2000RFParamInitAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.17 | This trap is issued when the RF parameter Init fails. | ||
| NTF trapDM2000TECParamInitAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.18 | This trap is issued when the TEC Parameter Init fails. | ||
| NTF trapDM2000AttnTableInitAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.19 | This trap is issued when the Attenuator Table Init fails. | ||
| NTF trapDM2000PowerMeterTableInitAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.20 | This trap is issued when the Power Meter Table Init fails. | ||
| NTF trapDM2000LaserDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.21 | This trap is issued when the Laser Data CRC is incorrect. | ||
| NTF trapDM2000AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.22 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapDM2000FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.23 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapDM2000UserRFOffAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.24 | This trap is issued when the the User RF is turned off. | ||
| NTF trapDM2000UserOpticalOffAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.25 | This trap is issued when the User Optical Power is turned off. | ||
| NTF trapDM2000ResetFactoryDefaultAlarm | 1.3.6.1.4.1.1166.6.1.2.34.0.26 | This trap is issued when the Factory Default Reset occurs. | ||
| gx2dm2000Descriptor | 1.3.6.1.4.1.1166.6.1.2.34.1 | |||
| gx2dm2000AnalogTable | 1.3.6.1.4.1.1166.6.1.2.34.2 | not-accessible | This table contains gx2Dm2000 specific parameters with nominal and current values. | |
| gx2dm2000AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.34.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2dm2000AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.34.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR dm2000labelOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Offset Monitor Analog parameter. |
| STR dm2000uomOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. |
| FLO dm2000majorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000majorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO dm2000minorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO dm2000currentValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.8 | Float | read-only | The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| INT dm2000stateFlagOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO dm2000minValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.10 | Float | read-only | The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number. |
| FLO dm2000maxValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.11 | Float | read-only | The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number. |
| INT dm2000alarmStateOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.34.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Monitor Analog parameter. |
| STR dm2000labelOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Offset Control Analog parameter. |
| STR dm2000uomOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.14 | DisplayString | read-only | The value of this object provides the label of the Offset Control Analog parameter. |
| FLO dm2000majorHighOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO dm2000majorLowOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. |
| FLO dm2000minorHighOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorLowOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000currentValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.19 | Float | read-write | The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000stateFlagOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable) |
| FLO dm2000minValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.21 | Float | read-only | The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000maxValueOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.22 | Float | read-only | The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000alarmStateOffsetNomCnt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Control Analog parameter. |
| STR dm2000labelRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Attenuator Setting Analog parameter. |
| STR dm2000uomRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter. |
| FLO dm2000majorHighRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000majorLowRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorHighRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorLowRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000currentValueRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.30 | Float | read-write | The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000stateFlagRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO dm2000minValueRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.32 | Float | read-only | The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000maxValueRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.33 | Float | read-only | The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000alarmStateRelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.34.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter. |
| STR dm2000labelOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Optical Power Analog parameter. |
| STR dm2000uomOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Optical Power Analog parameter. |
| FLO dm2000majorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000majorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorHighOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorLowOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000currentValueOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.41 | Float | read-only | The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000stateFlagOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO dm2000minValueOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.43 | Float | read-only | The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000maxValueOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.44 | Float | read-only | The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000alarmStateOptPower | 1.3.6.1.4.1.1166.6.1.2.34.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Optical Power Analog parameter. |
| STR dm2000labelLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| STR dm2000uomLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Bias Analog parameter. |
| FLO dm2000majorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000majorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorHighLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorLowLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000currentValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.52 | Float | read-only | The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000stateFlagLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO dm2000minValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.54 | Float | read-only | The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000maxValueLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.55 | Float | read-only | The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000alarmStateLaserBias | 1.3.6.1.4.1.1166.6.1.2.34.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Bias Analog parameter. |
| STR dm2000labelTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.57 | DisplayString | read-only | The value of this object provides the label of the TEC Current Analog parameter. |
| STR dm2000uomTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Current Analog parameter.. |
| FLO dm2000majorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000majorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000currentValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.63 | Float | read-only | The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000stateFlagTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.64 | INTEGER | read-only | The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO dm2000minValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.65 | Float | read-only | The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000maxValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.66 | Float | read-only | The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000alarmStateTecCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| STR dm2000labelLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Laser Temperature Analog parameter. |
| STR dm2000uomLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. |
| FLO dm2000majorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000majorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000currentValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.74 | Float | read-only | The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000stateFlagLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO dm2000minValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.76 | Float | read-only | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000maxValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.77 | Float | read-only | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000alarmStateLaserTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| STR dm2000labelModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR dm2000uomModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. |
| FLO dm2000majorHighModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000majorLowModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorHighModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorLowModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000currentValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.85 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000stateFlagModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO dm2000minValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.87 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000maxValueModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.88 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000alarmStateModuleTemp | 1.3.6.1.4.1.1166.6.1.2.34.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR dm2000labelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.90 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR dm2000uomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.91 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. |
| FLO dm2000majorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.92 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000majorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.93 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.94 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.95 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000currentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.96 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000stateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.97 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO dm2000minValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.98 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000maxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.99 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000alarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.34.2.1.100 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| STR dm2000label12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.101 | DisplayString | read-only | The value of this object provides the label of the 12v Current Analog parameter. |
| STR dm2000uom12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.102 | DisplayString | read-only | The value of this object provides the Unit of Measure of the 12v Current Analog parameter. |
| FLO dm2000majorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.103 | Float | read-only | The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000majorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.104 | Float | read-only | The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorHigh12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.105 | Float | read-only | The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000minorLow12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.106 | Float | read-only | The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000currentValue12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.107 | Float | read-only | The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000stateFlag12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.108 | INTEGER | read-only | The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| FLO dm2000minValue12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.109 | Float | read-only | The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm2000maxValue12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.110 | Float | read-only | The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm2000alarmState12Volt | 1.3.6.1.4.1.1166.6.1.2.34.2.1.111 | INTEGER | read-only | The value of this object provides the curent alarm state of the 12v Current Analog parameter. |
| gx2dm2000DigitalTable | 1.3.6.1.4.1.1166.6.1.2.34.3 | not-accessible | This table contains gx2Dm2000 specific parameters with nominal and current values. | |
| gx2dm2000DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.34.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2dm2000DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.34.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR dm2000labelRfInput | 1.3.6.1.4.1.1166.6.1.2.34.3.2.2 | DisplayString | read-only | The value of this object provides the label of the RF Input Control Digital parameter. |
| STR dm2000enumRfInput | 1.3.6.1.4.1.1166.6.1.2.34.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT dm2000valueRfInput | 1.3.6.1.4.1.1166.6.1.2.34.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT dm2000stateflagRfInput | 1.3.6.1.4.1.1166.6.1.2.34.3.2.5 | INTEGER | read-only | The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelOptOutput | 1.3.6.1.4.1.1166.6.1.2.34.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Optical Output Control Digital parameter. |
| STR dm2000enumOptOutput | 1.3.6.1.4.1.1166.6.1.2.34.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT dm2000valueOptOutput | 1.3.6.1.4.1.1166.6.1.2.34.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT dm2000stateflagOptOutput | 1.3.6.1.4.1.1166.6.1.2.34.3.2.9 | INTEGER | read-only | The value of this object provides the dm2000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelLaserMode | 1.3.6.1.4.1.1166.6.1.2.34.3.2.10 | DisplayString | read-only | The value of this object provides the label of the Laser Mode Digital parameter. |
| STR dm2000enumLaserMode | 1.3.6.1.4.1.1166.6.1.2.34.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT dm2000valueLaserMode | 1.3.6.1.4.1.1166.6.1.2.34.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT dm2000stateflagLaserMode | 1.3.6.1.4.1.1166.6.1.2.34.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.34.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Laser Secondary Mode Digital parameter. |
| STR dm2000enumLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.34.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT dm2000valueLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.34.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT dm2000stateflagLaserSecMode | 1.3.6.1.4.1.1166.6.1.2.34.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelVideoOffset | 1.3.6.1.4.1.1166.6.1.2.34.3.2.18 | DisplayString | read-only | The value of this object provides the label of the Video Offset Digital parameter. |
| STR dm2000enumVideoOffset | 1.3.6.1.4.1.1166.6.1.2.34.3.2.19 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.. |
| INT dm2000valueVideoOffset | 1.3.6.1.4.1.1166.6.1.2.34.3.2.20 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT dm2000stateflagVideoOffset | 1.3.6.1.4.1.1166.6.1.2.34.3.2.21 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.34.3.2.22 | DisplayString | read-only | The value of this object provides the label of the Factory Default Reset Digital parameter. |
| STR dm2000enumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.34.3.2.23 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT dm2000valueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.34.3.2.24 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT dm2000stateflagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.34.3.2.25 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelFiberLength | 1.3.6.1.4.1.1166.6.1.2.34.3.2.26 | DisplayString | read-only | The value of this object provides the label for the Fiber Length Digital parameter . |
| STR dm2000enumFiberLength | 1.3.6.1.4.1.1166.6.1.2.34.3.2.27 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. The range for fiber length selection is from 0 to 60km, where 0km is represented with a 1, and 60 with a 61. |
| INT dm2000valueFiberLength | 1.3.6.1.4.1.1166.6.1.2.34.3.2.28 | INTEGER | read-write | The value of this object is the current value of the parameter. It is used to set fiber length. The value range for this object is: 1 to 61. Where 1 = 0Km and 61 = 60Km |
| INT dm2000stateflagFiberLength | 1.3.6.1.4.1.1166.6.1.2.34.3.2.29 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelWavelengthOffset | 1.3.6.1.4.1.1166.6.1.2.34.3.2.30 | DisplayString | read-only | The value of this object provides the label for the Wavelength Offset Digital parameter . |
| STR dm2000enumWavelengthOffset | 1.3.6.1.4.1.1166.6.1.2.34.3.2.31 | DisplayString | read-only | The value of this object represents the Enumeration values possible for this Digital parameter. |
| INT dm2000valueWavelengthOffset | 1.3.6.1.4.1.1166.6.1.2.34.3.2.32 | INTEGER | read-write | The value of this object is the current value of the parameter. It is used to select a Narrowcast or Full Spectrum application. |
| INT dm2000stateflagWavelengthOffset | 1.3.6.1.4.1.1166.6.1.2.34.3.2.33 | INTEGER | read-only | The value of this object provides the state of the the Wavelength Offset parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2dm2000StatusTable | 1.3.6.1.4.1.1166.6.1.2.34.4 | not-accessible | This table contains gx2Dm2000 specific parameters with nominal and current values. | |
| gx2dm2000StatusEntry | 1.3.6.1.4.1.1166.6.1.2.34.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2dm2000StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.34.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR dm2000labelBoot | 1.3.6.1.4.1.1166.6.1.2.34.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT dm2000valueBoot | 1.3.6.1.4.1.1166.6.1.2.34.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT dm2000stateflagBoot | 1.3.6.1.4.1.1166.6.1.2.34.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelFlash | 1.3.6.1.4.1.1166.6.1.2.34.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT dm2000valueFlash | 1.3.6.1.4.1.1166.6.1.2.34.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT dm2000stateflagFlash | 1.3.6.1.4.1.1166.6.1.2.34.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.34.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT dm2000valueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.34.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT dm2000stateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.34.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.34.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Laser Data CRC Status parameter. |
| INT dm2000valueLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.34.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT dm2000stateflagLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.34.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.34.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT dm2000valueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.34.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT dm2000stateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.34.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelHWStatus | 1.3.6.1.4.1.1166.6.1.2.34.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Laser Drive Level Status parameter. |
| INT dm2000valueHWStatus | 1.3.6.1.4.1.1166.6.1.2.34.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT dm2000stateflagHWStatus | 1.3.6.1.4.1.1166.6.1.2.34.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| STR dm2000labelRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.34.4.3.20 | DisplayString | read-only | The value of this object provides the label of the RF Input Status parameter. |
| INT dm2000valueRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.34.4.3.21 | INTEGER | read-only | The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical). |
| INT dm2000stateflagRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.34.4.3.22 | INTEGER | read-only | The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable). |
| gx2dm2000FactoryTable | 1.3.6.1.4.1.1166.6.1.2.34.5 | not-accessible | This table contains gx2Dm2000 specific parameters with nominal and current values. | |
| gx2dm2000FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.34.5.4 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2dm2000FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.34.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT dm2000bootControlByteValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT dm2000bootStatusByteValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot |
| INT dm2000bank1CRCValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. |
| INT dm2000bank2CRCValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1. |
| INT dm2000prgEEPROMByteValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT dm2000factoryCRCValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT dm2000calculateCRCValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.8 | INTEGER | read-only | This object indicates which of the Emnums will have the CRC calculated. |
| INT dm2000hourMeterValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT dm2000flashPrgCntAValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT dm2000flashPrgCntBValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR dm2000flashBankARevValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. |
| STR dm2000flashBankBRevValue | 1.3.6.1.4.1.1166.6.1.2.34.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. |
| gx2Dm2000HoldTimeTable | 1.3.6.1.4.1.1166.6.1.2.34.6 | not-accessible | This table contains gx2Dm2000 specific parameters with nominal and current values. | |
| gx2Dm2000HoldTimeEntry | 1.3.6.1.4.1.1166.6.1.2.34.6.5 | not-accessible | This list contains digital product class and the associated RF channel parameters and descriptions. | |
| INT gx2Dm2000HoldTimeTableIndex | 1.3.6.1.4.1.1166.6.1.2.34.6.5.1 | INTEGER | read-only | The value of this object is the index of the data object. |
| INT gx2Dm2000HoldTimeSpecIndex | 1.3.6.1.4.1.1166.6.1.2.34.6.5.2 | INTEGER | read-only | The value of this object identifies the index of the alarm object to be modified. |
| INT gx2Dm2000HoldTimeData | 1.3.6.1.4.1.1166.6.1.2.34.6.5.3 | INTEGER | read-write | The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds. |
RFC description
Directly modulated laser module parameters and status for OMNI-GX2-DM2000 HFC network elements.
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 DM2000 downstream modulator module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.