OMNI-gx2DM2000-MIB :: dm2000minorLowTecCurrent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2DM2000-MIB › dm2000minorLowTecCurrent

dm2000minorLowTecCurrent

Module: OMNI-gx2DM2000-MIB

OID (symbolic): OMNI-gx2DM2000-MIB::dm2000minorLowTecCurrent

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.34.2.1.62

Node type: OBJECT-TYPE

Type: Float

Access: read-only

Description: The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.

What is dm2000minorLowTecCurrent?

Lower 'minor' alarm threshold for TEC Current, set above the major-low limit; crossing it raises an early, less severe warning that the current drawn by the thermoelectric cooler (TEC) that stabilizes the laser's temperature is trending low, giving an operator advance notice before a major-low alarm would fire.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.34.2.1.62
snmpwalk -v2c -c public <target> OMNI-gx2DM2000-MIB::dm2000minorLowTecCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.34.2.1.62.1
snmpget -v2c -c public <target> OMNI-gx2DM2000-MIB::dm2000minorLowTecCurrent.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 DM2000 downstream modulator module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2DM2000-MIB::dm2000minorLowTecCurrent OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 DM2000 downstream modulator module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.34gx2Dm2000GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.34.2gx2dm2000AnalogTableOMNI-gx2DM2000-MIB
1.3.6.1.4.1.1166.6.1.2.34.2.1gx2dm2000AnalogEntryOMNI-gx2DM2000-MIB
1.3.6.1.4.1.1166.6.1.2.34.2.1.62dm2000minorLowTecCurrentOMNI-gx2DM2000-MIB