OMNI-gx2DM2000-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2Dm2000 FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "0" Aug 18, 2011 --REVISION "1" May 22, 2012 --DESCRIPTION -- Added revision and description comment section -- OMNISTAR Directly Modulated Laser Module (Forward Path Transmetter) MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2Dm2000 Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Dm2000 device type. -- These parameters are common across all network elements -- from gx2Dm2000 device type. -- -- The gx2Dm2000 Network Elements subgroup is -- a list of gx2Dm2000 type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Dm2000TableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Dm2000 type. -- -- Both groups are mandatory for management of gx2Dm2000 devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2Dm2000 Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Dm2000 device type. -- These parameters are common across all network elements -- from gx2Dm2000 device type. gx2dm2000Descriptor OBJECT IDENTIFIER ::= {gx2Dm2000 1} --***************************************************************************** -- gx2Dm2000 Table -- Contains a list of all gx2Dm2000 type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2dm2000TableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2Dm2000 type. gx2dm2000AnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2dm2000AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm2000 specific parameters with nominal and current values." ::= { gx2Dm2000 2 } gx2dm2000AnalogEntry OBJECT-TYPE SYNTAX Gx2dm2000AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2dm2000AnalogTableIndex } ::= { gx2dm2000AnalogTable 1} --*********************************************************************** gx2dm2000DigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2dm2000DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm2000 specific parameters with nominal and current values." ::= { gx2Dm2000 3 } gx2dm2000DigitalEntry OBJECT-TYPE SYNTAX Gx2dm2000DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital parameters and descriptions." INDEX { gx2dm2000DigitalTableIndex } ::= { gx2dm2000DigitalTable 2} --*********************************************************************** gx2dm2000StatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2dm2000StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm2000 specific parameters with nominal and current values." ::= { gx2Dm2000 4 } gx2dm2000StatusEntry OBJECT-TYPE SYNTAX Gx2dm2000StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2dm2000StatusTableIndex } ::= { gx2dm2000StatusTable 3} --*********************************************************************** gx2dm2000FactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2dm2000FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm2000 specific parameters with nominal and current values." ::= { gx2Dm2000 5 } gx2dm2000FactoryEntry OBJECT-TYPE SYNTAX Gx2dm2000FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory parameters and descriptions." INDEX { gx2dm2000FactoryTableIndex } ::= { gx2dm2000FactoryTable 4} --*********************************************************************** gx2Dm2000HoldTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Dm2000HoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm2000 specific parameters with nominal and current values." ::= { gx2Dm2000 6 } gx2Dm2000HoldTimeEntry OBJECT-TYPE SYNTAX Gx2Dm2000HoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { gx2Dm2000HoldTimeTableIndex, gx2Dm2000HoldTimeSpecIndex } ::= { gx2Dm2000HoldTimeTable 5} Gx2dm2000AnalogEntry ::= SEQUENCE { gx2dm2000AnalogTableIndex INTEGER, -- Analog Parameters dm2000labelOffsetNomMonitor DisplayString (SIZE (0..80)), dm2000uomOffsetNomMonitor DisplayString (SIZE (0..80)), dm2000majorHighOffsetNomMonitor Float, dm2000majorLowOffsetNomMonitor Float, dm2000minorHighOffsetNomMonitor Float, dm2000minorLowOffsetNomMonitor Float, dm2000currentValueOffsetNomMonitor Float, dm2000stateFlagOffsetNomMonitor INTEGER, dm2000minValueOffsetNomMonitor Float, dm2000maxValueOffsetNomMonitor Float, dm2000alarmStateOffsetNomMonitor INTEGER, dm2000labelOffsetNomCnt DisplayString (SIZE (0..80)), dm2000uomOffsetNomCnt DisplayString (SIZE (0..80)), dm2000majorHighOffsetNomCnt Float, dm2000majorLowOffsetNomCnt Float, dm2000minorHighOffsetNomCnt Float, dm2000minorLowOffsetNomCnt Float, dm2000currentValueOffsetNomCnt Float, dm2000stateFlagOffsetNomCnt INTEGER, dm2000minValueOffsetNomCnt Float, dm2000maxValueOffsetNomCnt Float, dm2000alarmStateOffsetNomCnt INTEGER, dm2000labelRelAttenSetting DisplayString (SIZE (0..80)), dm2000uomRelAttenSetting DisplayString (SIZE (0..80)), dm2000majorHighRelAttenSetting Float, dm2000majorLowRelAttenSetting Float, dm2000minorHighRelAttenSetting Float, dm2000minorLowRelAttenSetting Float, dm2000currentValueRelAttenSetting Float, dm2000stateFlagRelAttenSetting INTEGER, dm2000minValueRelAttenSetting Float, dm2000maxValueRelAttenSetting Float, dm2000alarmStateRelAttenSetting INTEGER, dm2000labelOptPower DisplayString (SIZE (0..80)), dm2000uomOptPower DisplayString (SIZE (0..80)), dm2000majorHighOptPower Float, dm2000majorLowOptPower Float, dm2000minorHighOptPower Float, dm2000minorLowOptPower Float, dm2000currentValueOptPower Float, dm2000stateFlagOptPower INTEGER, dm2000minValueOptPower Float, dm2000maxValueOptPower Float, dm2000alarmStateOptPower INTEGER, dm2000labelLaserBias DisplayString (SIZE (0..80)), dm2000uomLaserBias DisplayString (SIZE (0..80)), dm2000majorHighLaserBias Float, dm2000majorLowLaserBias Float, dm2000minorHighLaserBias Float, dm2000minorLowLaserBias Float, dm2000currentValueLaserBias Float, dm2000stateFlagLaserBias INTEGER, dm2000minValueLaserBias Float, dm2000maxValueLaserBias Float, dm2000alarmStateLaserBias INTEGER, dm2000labelTecCurrent DisplayString (SIZE (0..80)), dm2000uomTecCurrent DisplayString (SIZE (0..80)), dm2000majorHighTecCurrent Float, dm2000majorLowTecCurrent Float, dm2000minorHighTecCurrent Float, dm2000minorLowTecCurrent Float, dm2000currentValueTecCurrent Float, dm2000stateFlagTecCurrent INTEGER, dm2000minValueTecCurrent Float, dm2000maxValueTecCurrent Float, dm2000alarmStateTecCurrent INTEGER, dm2000labelLaserTemp DisplayString (SIZE (0..80)), dm2000uomLaserTemp DisplayString (SIZE (0..80)), dm2000majorHighLaserTemp Float, dm2000majorLowLaserTemp Float, dm2000minorHighLaserTemp Float, dm2000minorLowLaserTemp Float, dm2000currentValueLaserTemp Float, dm2000stateFlagLaserTemp INTEGER, dm2000minValueLaserTemp Float, dm2000maxValueLaserTemp Float, dm2000alarmStateLaserTemp INTEGER, dm2000labelModuleTemp DisplayString (SIZE (0..80)), dm2000uomModuleTemp DisplayString (SIZE (0..80)), dm2000majorHighModuleTemp Float, dm2000majorLowModuleTemp Float, dm2000minorHighModuleTemp Float, dm2000minorLowModuleTemp Float, dm2000currentValueModuleTemp Float, dm2000stateFlagModuleTemp INTEGER, dm2000minValueModuleTemp Float, dm2000maxValueModuleTemp Float, dm2000alarmStateModuleTemp INTEGER, dm2000labelFanCurrent DisplayString (SIZE (0..80)), dm2000uomFanCurrent DisplayString (SIZE (0..80)), dm2000majorHighFanCurrent Float, dm2000majorLowFanCurrent Float, dm2000minorHighFanCurrent Float, dm2000minorLowFanCurrent Float, dm2000currentValueFanCurrent Float, dm2000stateFlagFanCurrent INTEGER, dm2000minValueFanCurrent Float, dm2000maxValueFanCurrent Float, dm2000alarmStateFanCurrent INTEGER, dm2000label12Volt DisplayString (SIZE (0..80)), dm2000uom12Volt DisplayString (SIZE (0..80)), dm2000majorHigh12Volt Float, dm2000majorLow12Volt Float, dm2000minorHigh12Volt Float, dm2000minorLow12Volt Float, dm2000currentValue12Volt Float, dm2000stateFlag12Volt INTEGER, dm2000minValue12Volt Float, dm2000maxValue12Volt Float, dm2000alarmState12Volt INTEGER } -- **************** Digital Parameters *********************** Gx2dm2000DigitalEntry ::= SEQUENCE { gx2dm2000DigitalTableIndex INTEGER, dm2000labelRfInput DisplayString (SIZE (0..80)), dm2000enumRfInput DisplayString (SIZE (0..80)), dm2000valueRfInput INTEGER, dm2000stateflagRfInput INTEGER, dm2000labelOptOutput DisplayString (SIZE (0..80)), dm2000enumOptOutput DisplayString (SIZE (0..80)), dm2000valueOptOutput INTEGER, dm2000stateflagOptOutput INTEGER, dm2000labelLaserMode DisplayString (SIZE (0..80)), dm2000enumLaserMode DisplayString (SIZE (0..80)), dm2000valueLaserMode INTEGER, dm2000stateflagLaserMode INTEGER, dm2000labelLaserSecMode DisplayString (SIZE (0..80)), dm2000enumLaserSecMode DisplayString (SIZE (0..80)), dm2000valueLaserSecMode INTEGER, dm2000stateflagLaserSecMode INTEGER, dm2000labelVideoOffset DisplayString (SIZE (0..80)), dm2000enumVideoOffset DisplayString (SIZE (0..80)), dm2000valueVideoOffset INTEGER, dm2000stateflagVideoOffset INTEGER, dm2000labelFactoryDefault DisplayString (SIZE (0..80)), dm2000enumFactoryDefault DisplayString (SIZE (0..80)), dm2000valueFactoryDefault INTEGER, dm2000stateflagFactoryDefault INTEGER, dm2000labelFiberLength DisplayString (SIZE (0..80)), dm2000enumFiberLength DisplayString (SIZE (0..80)), dm2000valueFiberLength INTEGER, dm2000stateflagFiberLength INTEGER, dm2000labelWavelengthOffset DisplayString (SIZE (0..80)), dm2000enumWavelengthOffset DisplayString (SIZE (0..80)), dm2000valueWavelengthOffset INTEGER, dm2000stateflagWavelengthOffset INTEGER } -- **************** Status Parameters ************************************ Gx2dm2000StatusEntry ::= SEQUENCE { gx2dm2000StatusTableIndex INTEGER, dm2000labelBoot DisplayString (SIZE (0..80)), dm2000valueBoot INTEGER, dm2000stateflagBoot INTEGER, dm2000labelFlash DisplayString (SIZE (0..80)), dm2000valueFlash INTEGER, dm2000stateflagFlash INTEGER, dm2000labelFactoryDataCRC DisplayString (SIZE (0..80)), dm2000valueFactoryDataCRC INTEGER, dm2000stateflagFactoryDataCRC INTEGER, dm2000labelLaserDataCRC DisplayString (SIZE (0..80)), dm2000valueLaserDataCRC INTEGER, dm2000stateflagLaserDataCRC INTEGER, dm2000labelAlarmDataCrc DisplayString (SIZE (0..80)), dm2000valueAlarmDataCrc INTEGER, dm2000stateflagAlarmDataCrc INTEGER, dm2000labelHWStatus DisplayString (SIZE (0..80)), dm2000valueHWStatus INTEGER, dm2000stateflagHWStatus INTEGER, dm2000labelRFInputStatus DisplayString (SIZE (0..80)), dm2000valueRFInputStatus INTEGER, dm2000stateflagRFInputStatus INTEGER } -- **************** Factory Parameters ************************************* Gx2dm2000FactoryEntry ::= SEQUENCE { gx2dm2000FactoryTableIndex INTEGER, dm2000bootControlByteValue INTEGER, dm2000bootStatusByteValue INTEGER, dm2000bank1CRCValue INTEGER, dm2000bank2CRCValue INTEGER, dm2000prgEEPROMByteValue INTEGER, dm2000factoryCRCValue INTEGER, dm2000calculateCRCValue INTEGER, dm2000hourMeterValue INTEGER, dm2000flashPrgCntAValue INTEGER, dm2000flashPrgCntBValue INTEGER, dm2000flashBankARevValue DisplayString (SIZE (0..80)), dm2000flashBankBRevValue DisplayString (SIZE (0..80)) } -- **************** Hold Time Parameters ************************************* Gx2Dm2000HoldTimeEntry ::= SEQUENCE { gx2Dm2000HoldTimeTableIndex INTEGER, gx2Dm2000HoldTimeSpecIndex INTEGER, gx2Dm2000HoldTimeData INTEGER } -- ************** Analog Parameters **************************** gx2dm2000AnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2dm2000AnalogEntry 1} -- New Parameter dm2000labelOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Monitor Analog parameter." ::= { gx2dm2000AnalogEntry 2} dm2000uomOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter." ::= { gx2dm2000AnalogEntry 3} dm2000majorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 4} dm2000majorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 5} dm2000minorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 6} dm2000minorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 7} dm2000currentValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 8} dm2000stateFlagOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)" ::= { gx2dm2000AnalogEntry 9} dm2000minValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 10} dm2000maxValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 11} dm2000alarmStateOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Offset Monitor Analog parameter." ::= { gx2dm2000AnalogEntry 12} -- New Parameter dm2000labelOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Control Analog parameter." ::= { gx2dm2000AnalogEntry 13} dm2000uomOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Control Analog parameter." ::= { gx2dm2000AnalogEntry 14} dm2000majorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 15} dm2000majorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 16} dm2000minorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 17} dm2000minorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 18} dm2000currentValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 19} dm2000stateFlagOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)" ::= { gx2dm2000AnalogEntry 20} dm2000minValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 21} dm2000maxValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 22} dm2000alarmStateOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Offset Control Analog parameter." ::= { gx2dm2000AnalogEntry 23} -- New Parameter dm2000labelRelAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Attenuator Setting Analog parameter." ::= { gx2dm2000AnalogEntry 24} dm2000uomRelAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter." ::= { gx2dm2000AnalogEntry 25} dm2000majorHighRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 26} dm2000majorLowRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 27} dm2000minorHighRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 28} dm2000minorLowRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 29} dm2000currentValueRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 30} dm2000stateFlagRelAttenSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000AnalogEntry 31} dm2000minValueRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 32} dm2000maxValueRelAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 33} dm2000alarmStateRelAttenSetting OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter." ::= { gx2dm2000AnalogEntry 34} -- New Parameter dm2000labelOptPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Power Analog parameter." ::= { gx2dm2000AnalogEntry 35} dm2000uomOptPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Optical Power Analog parameter." ::= { gx2dm2000AnalogEntry 36} dm2000majorHighOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 37} dm2000majorLowOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 38} dm2000minorHighOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 39} dm2000minorLowOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 40} dm2000currentValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 41} dm2000stateFlagOptPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000AnalogEntry 42} dm2000minValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 43} dm2000maxValueOptPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 44} dm2000alarmStateOptPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Optical Power Analog parameter." ::= { gx2dm2000AnalogEntry 45} -- New Parameter dm2000labelLaserBias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Bias Current Analog parameter." ::= { gx2dm2000AnalogEntry 46} dm2000uomLaserBias OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Bias Analog parameter." ::= { gx2dm2000AnalogEntry 47} dm2000majorHighLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 48} dm2000majorLowLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 49} dm2000minorHighLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 50} dm2000minorLowLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 51} dm2000currentValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 52} dm2000stateFlagLaserBias OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000AnalogEntry 53} dm2000minValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 54} dm2000maxValueLaserBias OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 55} dm2000alarmStateLaserBias OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Bias Analog parameter." ::= { gx2dm2000AnalogEntry 56} -- New Parameter dm2000labelTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Current Analog parameter." ::= { gx2dm2000AnalogEntry 57} dm2000uomTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Current Analog parameter.." ::= { gx2dm2000AnalogEntry 58} dm2000majorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 59} dm2000majorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 60} dm2000minorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 61} dm2000minorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 62} dm2000currentValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 63} dm2000stateFlagTecCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000AnalogEntry 64} dm2000minValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 65} dm2000maxValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 66} dm2000alarmStateTecCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Current Analog parameter." ::= { gx2dm2000AnalogEntry 67} -- New Parameter dm2000labelLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Temperature Analog parameter." ::= { gx2dm2000AnalogEntry 68} dm2000uomLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter." ::= { gx2dm2000AnalogEntry 69} dm2000majorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 70} dm2000majorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 71} dm2000minorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 72} dm2000minorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 73} dm2000currentValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 74} dm2000stateFlagLaserTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000AnalogEntry 75} dm2000minValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 76} dm2000maxValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 77} dm2000alarmStateLaserTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Temperature Analog parameter." ::= { gx2dm2000AnalogEntry 78} -- New Parameter dm2000labelModuleTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2dm2000AnalogEntry 79} dm2000uomModuleTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2dm2000AnalogEntry 80} dm2000majorHighModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 81} dm2000majorLowModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 82} dm2000minorHighModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 83} dm2000minorLowModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 84} dm2000currentValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 85} dm2000stateFlagModuleTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000AnalogEntry 86} dm2000minValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 87} dm2000maxValueModuleTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 88} dm2000alarmStateModuleTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2dm2000AnalogEntry 89} -- New Parameter dm2000labelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2dm2000AnalogEntry 90} dm2000uomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2dm2000AnalogEntry 91} dm2000majorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 92} dm2000majorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 93} dm2000minorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 94} dm2000minorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 95} dm2000currentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 96} dm2000stateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000AnalogEntry 97} dm2000minValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 98} dm2000maxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 99} dm2000alarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2dm2000AnalogEntry 100} -- New Parameter dm2000label12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the 12v Current Analog parameter." ::= { gx2dm2000AnalogEntry 101} dm2000uom12Volt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the 12v Current Analog parameter." ::= { gx2dm2000AnalogEntry 102} dm2000majorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 103} dm2000majorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 104} dm2000minorHigh12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 105} dm2000minorLow12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 106} dm2000currentValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 107} dm2000stateFlag12Volt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000AnalogEntry 108} dm2000minValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 109} dm2000maxValue12Volt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2dm2000AnalogEntry 110} dm2000alarmState12Volt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the 12v Current Analog parameter." ::= { gx2dm2000AnalogEntry 111} -- ************************ Digital parameters ********************************** gx2dm2000DigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2dm2000DigitalEntry 1} -- New parameter dm2000labelRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Input Control Digital parameter." ::= { gx2dm2000DigitalEntry 2} dm2000enumRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2dm2000DigitalEntry 3} dm2000valueRfInput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2dm2000DigitalEntry 4} dm2000stateflagRfInput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000DigitalEntry 5} -- New parameter dm2000labelOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Output Control Digital parameter." ::= { gx2dm2000DigitalEntry 6} dm2000enumOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2dm2000DigitalEntry 7} dm2000valueOptOutput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2dm2000DigitalEntry 8} dm2000stateflagOptOutput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the dm2000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000DigitalEntry 9} -- New parameter dm2000labelLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Mode Digital parameter." ::= { gx2dm2000DigitalEntry 10} dm2000enumLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2dm2000DigitalEntry 11} dm2000valueLaserMode OBJECT-TYPE SYNTAX INTEGER { preset(1), set(2), setEquate(3), manual(4), manualEquate(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2dm2000DigitalEntry 12} dm2000stateflagLaserMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000DigitalEntry 13} -- New parameter dm2000labelLaserSecMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Secondary Mode Digital parameter." ::= { gx2dm2000DigitalEntry 14} dm2000enumLaserSecMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2dm2000DigitalEntry 15} dm2000valueLaserSecMode OBJECT-TYPE SYNTAX INTEGER { cw(1), video(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2dm2000DigitalEntry 16} dm2000stateflagLaserSecMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000DigitalEntry 17} -- New parameter dm2000labelVideoOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Video Offset Digital parameter." ::= { gx2dm2000DigitalEntry 18} dm2000enumVideoOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.." ::= { gx2dm2000DigitalEntry 19} dm2000valueVideoOffset OBJECT-TYPE SYNTAX INTEGER { minus2dB(1), minus3dB(2), minus4dB(3), minus5dB(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2dm2000DigitalEntry 20} dm2000stateflagVideoOffset OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000DigitalEntry 21} -- New parameter dm2000labelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2dm2000DigitalEntry 22} dm2000enumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2dm2000DigitalEntry 23} dm2000valueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2dm2000DigitalEntry 24} dm2000stateflagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000DigitalEntry 25} -- New Parameter dm2000labelFiberLength OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label for the Fiber Length Digital parameter ." ::= { gx2dm2000DigitalEntry 26} dm2000enumFiberLength OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. The range for fiber length selection is from 0 to 60km, where 0km is represented with a 1, and 60 with a 61." ::= { gx2dm2000DigitalEntry 27} dm2000valueFiberLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is used to set fiber length. The value range for this object is: 1 to 61. Where 1 = 0Km and 61 = 60Km" ::= { gx2dm2000DigitalEntry 28} dm2000stateflagFiberLength OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000DigitalEntry 29} -- THE OBJECTS FOR "WAVELENGTH OFFSET" ARE ONLY USED FOR CERTAIN UNITS IN THE DM2000 DEVICE FAMILY dm2000labelWavelengthOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label for the Wavelength Offset Digital parameter ." ::= { gx2dm2000DigitalEntry 30} dm2000enumWavelengthOffset OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for this Digital parameter. " ::= { gx2dm2000DigitalEntry 31} dm2000valueWavelengthOffset OBJECT-TYPE SYNTAX INTEGER { narrowcast(1), FullSpectrum(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. It is used to select a Narrowcast or Full Spectrum application." ::= { gx2dm2000DigitalEntry 32} dm2000stateflagWavelengthOffset OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the Wavelength Offset parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000DigitalEntry 33} --*********** STATUS ***************** gx2dm2000StatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2dm2000StatusEntry 1} --New Parameter dm2000labelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2dm2000StatusEntry 2} dm2000valueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2dm2000StatusEntry 3} dm2000stateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000StatusEntry 4} --New Parameter dm2000labelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2dm2000StatusEntry 5} dm2000valueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2dm2000StatusEntry 6} dm2000stateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000StatusEntry 7} --New Parameter dm2000labelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2dm2000StatusEntry 8} dm2000valueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2dm2000StatusEntry 9} dm2000stateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000StatusEntry 10} --New Parameter dm2000labelLaserDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Data CRC Status parameter." ::= { gx2dm2000StatusEntry 11} dm2000valueLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2dm2000StatusEntry 12} dm2000stateflagLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000StatusEntry 13} --New Parameter dm2000labelAlarmDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2dm2000StatusEntry 14} dm2000valueAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2dm2000StatusEntry 15} dm2000stateflagAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000StatusEntry 16} --New Parameter dm2000labelHWStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Drive Level Status parameter." ::= { gx2dm2000StatusEntry 17} dm2000valueHWStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2dm2000StatusEntry 18} dm2000stateflagHWStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000StatusEntry 19} --New Parameter dm2000labelRFInputStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Input Status parameter." ::= { gx2dm2000StatusEntry 20} dm2000valueRFInputStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2dm2000StatusEntry 21} dm2000stateflagRFInputStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2dm2000StatusEntry 22} -- ************ FACTORY DATA **************** gx2dm2000FactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2dm2000FactoryEntry 1} dm2000bootControlByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2dm2000FactoryEntry 2} dm2000bootStatusByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2dm2000FactoryEntry 3} dm2000bank1CRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2dm2000FactoryEntry 4} dm2000bank2CRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2dm2000FactoryEntry 5} dm2000prgEEPROMByteValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2dm2000FactoryEntry 6} dm2000factoryCRCValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2dm2000FactoryEntry 7} dm2000calculateCRCValue OBJECT-TYPE SYNTAX INTEGER { factory(1), laserData(2), alarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates which of the Emnums will have the CRC calculated." ::= { gx2dm2000FactoryEntry 8} dm2000hourMeterValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2dm2000FactoryEntry 9} dm2000flashPrgCntAValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2dm2000FactoryEntry 10} dm2000flashPrgCntBValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2dm2000FactoryEntry 11} dm2000flashBankARevValue OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0." ::= { gx2dm2000FactoryEntry 12} dm2000flashBankBRevValue OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1." ::= { gx2dm2000FactoryEntry 13} -- ************ Hold Time DATA **************** gx2Dm2000HoldTimeTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the index of the data object." ::= { gx2Dm2000HoldTimeEntry 1} gx2Dm2000HoldTimeSpecIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the index of the alarm object to be modified." ::= { gx2Dm2000HoldTimeEntry 2} gx2Dm2000HoldTimeData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds." ::= { gx2Dm2000HoldTimeEntry 3} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** --*************************************************************************** -- ***********!!! THE TRAP SECTION HAS NOT BEEN COMPLETED YET !!! *********** --*************************************************************************** -- ************************************************************************** -- Laser Module traps -- ************************************************************************** trapDM2000ConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapDM2000ConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapDM2000RFInputAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapDM2000RFOverloadAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapDM2000RFOffsetAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 5 trapDM2000OpticalPowerAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 6 trapDM2000LaserBiasAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 7 trapDM2000LaserTempAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 8 trapDM2000TECCurrentAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 9 trapDM2000FanCurrentAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 10 trapDM200012vAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 11 trapDM2000ModuleTempAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Module Temperature goes out of range." ::= 12 trapDM2000FlashAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error during Flash memory operations." ::= 13 trapDM2000LaserBiasCntLoopAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation." ::= 14 trapDM2000BankBootAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1." ::= 15 trapDM2000LaserBiasCntLoopInitAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Bias Control loop init fails." ::= 16 trapDM2000RFParamInitAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RF parameter Init fails." ::= 17 trapDM2000TECParamInitAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the TEC Parameter Init fails." ::= 18 trapDM2000AttnTableInitAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Attenuator Table Init fails." ::= 19 trapDM2000PowerMeterTableInitAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Power Meter Table Init fails." ::= 20 trapDM2000LaserDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Data CRC is incorrect." ::= 21 trapDM2000AlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 22 trapDM2000FactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 23 trapDM2000UserRFOffAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the the User RF is turned off." ::= 24 trapDM2000UserOpticalOffAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the User Optical Power is turned off." ::= 25 trapDM2000ResetFactoryDefaultAlarm TRAP-TYPE ENTERPRISE gx2Dm2000 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Default Reset occurs." ::= 26 END