| OID symbolic | OID numeric | Type | Access | Description |
| juniAtm1483ProfileMIB | 1.3.6.1.4.1.4874.2.2.58 | | | The ATM Profile MIB for the Juniper Networks, Inc. enterprise. |
| juniAtm1483ProfileObjects | 1.3.6.1.4.1.4874.2.2.58.1 | | | |
| juniAtm1483Profile | 1.3.6.1.4.1.4874.2.2.58.1.1 | | | |
| juniAtm1483ProfileTable | 1.3.6.1.4.1.4874.2.2.58.1.1.1 | | not-accessible | This table contains profiles for configuring bulk ATM circuits.
Entries in this table are created/deleted as a side-effect of
corresponding operations to the juniProfileNameTable in the
Juniper-PROFILE-MIB. |
| juniAtm1483ProfileEntry | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1 | | not-accessible | A profile describing VCC configuration of an ATM subinterface. |
| U32 juniAtm1483ProfileId | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.1 | Unsigned32 | not-accessible | The integer identifier associated with this profile. A value for this
identifier is determined by locating or creating a profile name in the
juniProfileNameTable. |
| JUN juniAtm1483ProfileSetMap | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.2 | JuniSetMap | read-write | A bitmap representing which objects in this entry have been explicitly
configured. See the definition of the JuniSetMap TEXTUAL-CONVENTION for
details of use.
The INDEX object(s) and this object are excluded from representation
(i.e. their bits are never set).
When a SET request does not explicitly configure JuniSetMap, bits in
JuniSetMap are set as a side-effect of configuring other profile
attributes in the same entry.
If, however, a SET request explicitly configures JuniSetMap, the
explicitly configured value overrides 1) any previous bit settings, and
2) any simultaneous 'side-effect' settings that would otherwise occur.
Once set, bits can only be cleared by explicitly configuring
JuniSetMap. |
| INT juniAtm1483ProfileVccType | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.3 | INTEGER | read-write | Specifies the encapsulation used by the circuit to carry IP datagrams.
Encapsulations are as specified in RFC1483 Multiprotocol Interconnect
over ATM. 'autoconfig' will recognize both VcMux and LLC formats. |
| INT juniAtm1483ProfileVccServiceCategory | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.4 | INTEGER | read-write | Service category for this circuit:
ubr Unspecified Bit Rate (best effort).
ubrPcr Unspecified Bit Rate with Peak Cell Rate limit.
nrtVbr Non-realtime Variable Bit Rate.
cbr Constant Bit Rate.
rtVbr Realtime Variable Bit Rate. |
| G32 juniAtm1483ProfileVccPcr | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.5 | Gauge32 | read-write | Peak Cell Rate, in kilo-bits per second (kbps), of this circuit.
This parameter is only required when
juniAtm1483ProfileVccServiceCategory is configured to have one of the
following values:
ubrPcr
nrtVbr
cbr
rtVbr |
| G32 juniAtm1483ProfileVccScr | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.6 | Gauge32 | read-write | Sustained Cell Rate, in kilo-bits per second (kbps), of this circuit.
This parameter is only required when
juniAtm1483ProfileVccServiceCategory is configured to have one of the
following values:
nrtVbr
rtVbr |
| G32 juniAtm1483ProfileVccMbs | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.7 | Gauge32 | read-write | Maximum Burst Size, in cells, of this circuit.
This parameter is only required when
juniAtm1483ProfileVccServiceCategory is configured to have one of the
following values:
nrtVbr
rtVbr |
| STR juniAtm1483ProfileIfAlias | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.8 | DisplayString | read-write | This object is an 'alias' name for the interface as specified by a
network manager, and provides a non-volatile 'handle' for the interface.
This object initializes ifAlias for the interface. Note, all
interfaces created through the same profile entry will have identical
values for ifAlias. |
| I32 juniAtm1483ProfileAdvisoryRxSpeed | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.9 | Integer32 | read-write | Advisory receive speed, in kilobits per second (kbps),
of this subinterface. This object has no impact on
forwarding performance but may be used as a hint for the
underlying circuit receive speed. A value of 0 indicates
that this feature is not enabled. |
| INT juniAtm1483ProfileVccOamAdminStatus | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.10 | INTEGER | read-write | The administrative state of OAM for the interface identified by this
entry. |
| U32 juniAtm1483ProfileVccOamLoopbackFrequency | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.11 | Unsigned32 | read-write | The OAM loopback frequency for the interface identified by this entry. |
| STR juniAtm1483ProfileVcClassName | 1.3.6.1.4.1.4874.2.2.58.1.1.1.1.12 | DisplayString | read-write | The name of the ATM VC class assigned to this profile. |
| juniAtm1483ProfileAutoConfTable | 1.3.6.1.4.1.4874.2.2.58.1.1.2 | | not-accessible | Configures recognition of incoming data encapsulation types that
trigger autoconfiguration on an interface. |
| juniAtm1483ProfileAutoConfEntry | 1.3.6.1.4.1.4874.2.2.58.1.1.2.1 | | not-accessible | Configures recognition of an incoming data encapsulation type that
triggers autoconfiguration on an interface. |
| U32 juniAtm1483ProfileAutoConfId | 1.3.6.1.4.1.4874.2.2.58.1.1.2.1.1 | Unsigned32 | not-accessible | The integer identifier associated with this profile. A value for this
identifier is determined by locating or creating a profile name in the
juniProfileNameTable. |
| JUN juniAtm1483ProfileAutoConfEncaps | 1.3.6.1.4.1.4874.2.2.58.1.1.2.1.2 | JuniProfileIfEncaps | not-accessible | The encapsulating protocol type to which the autconfiguration
information in this entry applies.
The valid values are:
ip(0),
ppp(1),
pppoe(17),
bridgedEthernet(19) |
| JUN juniAtm1483ProfileAutoConfEnable | 1.3.6.1.4.1.4874.2.2.58.1.1.2.1.3 | JuniEnable | read-write | When enabled, permits autoconfiguration of the specified interface when
the specified encapsulation is recognized in an incoming data frame.
This parameter can only be set when juniAtm1483ProfileAutoConfEncaps is
configured to one of the following values:
ip(0),
ppp(1)
pppoe(17),
bridgedEthernet(19) |
| I32 juniAtm1483ProfileAutoConfLockoutMin | 1.3.6.1.4.1.4874.2.2.58.1.1.2.1.4 | Integer32 | read-write | The lower bound, in seconds, of the time range used to specify
the duration of the lockout of the encapsulation type from
recognition for the specified interface. This only takes effect
if juniAtm1483ProfileAutoConfEnable is set to enable for the
encapsulation type for this interface.
The ability to lockout the specified encapsulation type from
recognition in the event of an error in creating an interface of
the encapsulation type is enabled by default. The initial lockout
duration is this object's value and increases exponentially for
each failure that occurs for the specified encapsulation type
for the specified interface within the greater of 15 minutes and
juniAtm1483ProfileAutoConfLockoutMax. The lockout duration for the
specified encapsulation type will not exceed
juniAtm1483ProfileAutoConfLockoutMax. If the time between creation
errors for the specified encapsulation type for the specified
interface is greater than the greater of 15 minutes and
juniAtm1483ProfileAutoConfLockoutMax, then the lockout duration
reverts to this object's value.
To disable the ability to lockout the specified encapsulation type
from recognition in the event of an error in creating an interface
of the encapsulation type for the specified interface, the value of
this object and juniAtm1483ProfileAutoConfLockoutMax must be set to 0.
It is not recommended that this lockout feature be disabled except
for debugging purposes. |
| I32 juniAtm1483ProfileAutoConfLockoutMax | 1.3.6.1.4.1.4874.2.2.58.1.1.2.1.5 | Integer32 | read-write | The upper bound, in seconds, of the time range used to specify
the duration of the lockout of the encapsulation type from
recognition for the specified interface. This value must equal
or exceed the value for juniAtm1483ProfileAutoConfLockoutMin. This
only takes effect if juniAtm1483ProfileAutoConfEnable is set to
enable for the encapsulation type for this interface.
The ability to lockout the specified encapsulation type from
recognition in the event of an error in creating an interface of
the encapsulation type is enabled by default. The initial lockout
duration is juniAtm1483ProfileAutoConfLockoutMin and increases
exponentially for each failure that occurs for the specified
encapsulation type for the specified interface within the greater
of 15 minutes and this object's value. The lockout duration for
the specified encapsulation type will not exceed this object's
value. If the time between creation errors for the specified
encapsulation type for the specified interface is greater than
the greater of 15 minutes and this object's value, then the
lockout duration reverts to juniAtm1483ProfileAutoConfLockoutMin.
To disable the ability to lockout the specified encapsulation type
from recognition in the event of an error in creating an interface
of the encapsulation type for the specified interface, the value of
this object and juniAtm1483ProfileAutoConfLockoutMin must be set to 0.
It is not recommended that this lockout feature be disabled except
for debugging purposes. |
| juniAtm1483ProfileNestedProfileTable | 1.3.6.1.4.1.4874.2.2.58.1.1.3 | | not-accessible | Specifies nested profiles for incoming data encapsulation types.
Entries in this table are created/deleted as a side-effect of
corresponding operations to the juniProfileNameTable in the
Juniper-PROFILE-MIB. |
| juniAtm1483ProfileNestedProfileEntry | 1.3.6.1.4.1.4874.2.2.58.1.1.3.1 | | not-accessible | Specifies nested profile for incoming data encapsulation type. |
| U32 juniAtm1483ProfileNestedProfileId | 1.3.6.1.4.1.4874.2.2.58.1.1.3.1.1 | Unsigned32 | not-accessible | The integer identifier associated with this profile. A value for this
identifier is determined by locating or creating a profile name in the
juniProfileNameTable. |
| JUN juniAtm1483ProfileNestedProfileEncaps | 1.3.6.1.4.1.4874.2.2.58.1.1.3.1.2 | JuniProfileIfEncaps | not-accessible | The encapsulating protocol type to which the nested profile specified
in this entry applies.
The valid values are:
ip(0),
ppp(1),
pppoe(17),
bridgedEthernet(19) |
| STR juniAtm1483ProfileNestedProfileUpperIfProfileName | 1.3.6.1.4.1.4874.2.2.58.1.1.3.1.3 | DisplayString | read-write | The name of profile used for the protocol type specified by
juniAtm1483ProfileNestedProfileEncaps. |
| juniAtm1483ProfileSubscriberTable | 1.3.6.1.4.1.4874.2.2.58.1.1.4 | | not-accessible | Configures subscriber identity used in circumstances where the remote
subscriber's identity cannot be queried directly (e.g. dynamic IPoA
operation).
Entries in this table are created/deleted as a side-effect of
corresponding operations to the juniProfileNameTable in the
Juniper-PROFILE-MIB. |
| juniAtm1483ProfileSubscriberEntry | 1.3.6.1.4.1.4874.2.2.58.1.1.4.1 | | not-accessible | Configures subscriber identity used in circumstances where the remote
subscriber's identity cannot be queried directly (e.g. dynamic IPoA
operation). |
| U32 juniAtm1483ProfileSubscriberId | 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.1 | Unsigned32 | not-accessible | The integer identifier associated with this profile. A value for this
identifier is determined by locating or creating a profile name in the
juniProfileNameTable. |
| JUN juniAtm1483ProfileSubscriberEncaps | 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.2 | JuniProfileIfEncaps | not-accessible | The encapsulating protocol type to which the subscriber information in
this entry applies.
The valid values are:
ip(0),
bridgedEthernet(19) |
| JUN juniAtm1483ProfileSubscriberNamePrefix | 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.3 | JuniEnable | read-write | If enabled, indicates whether the value of juniSubscriberName is a
prefix rather than a full name.
This parameter is valid only when juniAtm1483ProfileSubscriberEncaps is
configured to one of the following values:
ip(0),
bridgedEthernet(19)
For all other values of juniAtm1483ProfileSubscriberEncaps it returns
'disable'. |
| STR juniAtm1483ProfileSubscriberName | 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.4 | DisplayString | read-write | If juniAtm1483ProfileSubscriberNamePrefix has the value 'enabled', the
value of this object serves as the prefix of a full subscriber name.
The full name is constructed by appending local geographic information
(slot, port, etc.) that uniquely distinguishes the subscriber.
This parameter is valid only when juniAtm1483ProfileSubscriberEncaps is
configured to one of the following values:
ip(0),
bridgedEthernet(19)
For all other values of juniAtm1483ProfileSubscriberEncaps it returns an
empty string. |
| JUN juniAtm1483ProfileSubscriberPasswordPrefix | 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.5 | JuniEnable | read-write | If enabled, indicates whether the value of
juniAtm1483ProfileSubscriberPassword is a prefix rather than a full
password.
This parameter is valid only when juniAtm1483ProfileSubscriberEncaps is
configured to one of the following values:
ip(0),
bridgedEthernet(19)
For all other values of juniAtm1483ProfileSubscriberEncaps it returns an
empty string. |
| STR juniAtm1483ProfileSubscriberPassword | 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.6 | DisplayString | read-write | The subscriber's password.
If juniAtm1483ProfileSubscriberPasswordPrefix has the value 'enabled',
the value of this object serves as the prefix of a full subscriber
password. The full password is constructed by appending local
geographic information (slot, port, etc.) that uniquely distinguishes
the subscriber.
This parameter is valid only when juniAtm1483ProfileSubscriberEncaps is
configured to one of the following values:
ip(0),
bridgedEthernet(19)
For all other values of juniAtm1483ProfileSubscriberEncaps it returns an
empty string. |
| STR juniAtm1483ProfileSubscriberDomain | 1.3.6.1.4.1.4874.2.2.58.1.1.4.1.7 | DisplayString | read-write | The subscriber's domain.
This parameter is valid only when juniAtm1483ProfileSubscriberEncaps is
configured to one of the following values:
ip(0),
bridgedEthernet(19)
For all other values of juniAtm1483ProfileSubscriberEncaps it returns an
empty string. |
| juniAtm1483ProfileConformance | 1.3.6.1.4.1.4874.2.2.58.4 | | | |
| juniAtm1483ProfileCompliances | 1.3.6.1.4.1.4874.2.2.58.4.1 | | | |
| juniAtm1483ProfileCompliance | 1.3.6.1.4.1.4874.2.2.58.4.1.1 | | | Obsolete compliance statement for entities which implement the Juniper
ATM Profile MIB. This statement became obsolete when ifALias support
was added to profile entries. |
| juniAtm1483ProfileCompliance2 | 1.3.6.1.4.1.4874.2.2.58.4.1.2 | | | Obsolete compliance statement for entities which implement the Juniper
ATM Profile MIB. This statement became obsolete when lockout objects
were added to juniAtm1483ProfileAutoConfTable. |
| juniAtm1483ProfileCompliance3 | 1.3.6.1.4.1.4874.2.2.58.4.1.3 | | | Obsolete compliance statement for entities which implement the Juniper ATM
Profile MIB. |
| juniAtm1483ProfileCompliance4 | 1.3.6.1.4.1.4874.2.2.58.4.1.4 | | | The compliance statement for entities which implement the Juniper ATM
Profile MIB. |
| juniAtm1483ProfileGroups | 1.3.6.1.4.1.4874.2.2.58.4.2 | | | |
| juniAtm1483ProfileGroup | 1.3.6.1.4.1.4874.2.2.58.4.2.1 | | | Obsolete collection of objects providing management of profile
functionality for ATM subinterfaces in a Juniper product. This group
became obsolete when ifALias support was added to profile entries. |
| juniAtm1483ProfileGroup2 | 1.3.6.1.4.1.4874.2.2.58.4.2.2 | | | Obolete collection of objects providing management of profile
functionalityfor ATM subinterfaces in a Juniper product. This group
became obsolete when OAM support was added to profile entries. |
| juniAtm1483ProfileGroup3 | 1.3.6.1.4.1.4874.2.2.58.4.2.3 | | | Obsolete collection of objects providing management of profile
functionality for ATM subinterfaces in a Juniper product. This group
became obsolete when ifALias support was added to profile entries. |
| juniAtm1483ProfileGroup4 | 1.3.6.1.4.1.4874.2.2.58.4.2.4 | | | Obsolete collection of objects providing management of profile
functionality for ATM subinterfaces in a Juniper product. This group
became obsolete when Encapsulation Type Lockout objects were added
to profile entries. |
| juniAtm1483ProfileGroup5 | 1.3.6.1.4.1.4874.2.2.58.4.2.5 | | | Obsolete collection of objects providing management of profile functionality
for ATM subinterfaces in a Juniper product. |
| juniAtm1483ProfileGroup6 | 1.3.6.1.4.1.4874.2.2.58.4.2.6 | | | A collection of objects providing management of profile functionality
for ATM subinterfaces in a Juniper product. |