| OID symbolic | OID numeric | Type | Access | Description |
| gdc | 1.3.6.1.4.1.498 | | | |
| bql2 | 1.3.6.1.4.1.498.12 | | | |
| bql611 | 1.3.6.1.4.1.498.12.2 | | | |
| STR bql611MIBVersion | 1.3.6.1.4.1.498.12.2.1 | DisplayString | read-only | The version number of the MIB, to allow products to
know which MIB is being supported. The version number
will be x.yzT where x is a major revision (1-9), y is a minor
revision(0-9), z is a typo revision (0-9) and T indicates the
MIB is still a test revision(A-Z). When a release is complete
no T should exist. |
| bql611WhatAreYouTable | 1.3.6.1.4.1.498.12.2.2 | | not-accessible | The GDC SC611 and DC621 What Are You Table. |
| bql611WhatAreYouEntry | 1.3.6.1.4.1.498.12.2.2.1 | | not-accessible | An entry in the GDC SC611 What Are You table. |
| SCI bql611WhatAreYouIndex | 1.3.6.1.4.1.498.12.2.2.1.1 | SCinstance | read-only | This object is the identifier of the SC611/DC621 What Are You table. |
| INT bql611BaseCardType | 1.3.6.1.4.1.498.12.2.2.1.2 | INTEGER | read-only | This function returns the value the Base Card Type. |
| INT bql611OptionCard | 1.3.6.1.4.1.498.12.2.2.1.3 | INTEGER | read-only | This indicates whether the option card is installed or not
on the DC621. |
| INT bql611DTECardType | 1.3.6.1.4.1.498.12.2.2.1.4 | INTEGER | read-only | This object is the DTE plug-in card type. This variable
is used for a SC611 or DC621. |
| STR bql611CodeRev | 1.3.6.1.4.1.498.12.2.2.1.5 | DisplayString | read-only | This function returns the firmware code level.
Example A- ,B- |
| OCT bql611AlarmStatus | 1.3.6.1.4.1.498.12.2.2.1.6 | OCTET STRING | read-only | The current alarms of the unit without the alarm masks. |
| bql611ConfigTable | 1.3.6.1.4.1.498.12.2.3 | | not-accessible | The GDC SC611, DC621 2B1Q configuration table. |
| bql611ConfigEntry | 1.3.6.1.4.1.498.12.2.3.1 | | not-accessible | A listing of GDC 2B1Q SC611/DC621 options. |
| SCI bql611ConfigIndex | 1.3.6.1.4.1.498.12.2.3.1.1 | SCinstance | read-only | A unique index for the Configuration Table. |
| INT bql611DteRate | 1.3.6.1.4.1.498.12.2.3.1.2 | INTEGER | read-write | Object to select the DTE rate for the SC611 or DC621. |
| INT bql611RateAdaption | 1.3.6.1.4.1.498.12.2.3.1.3 | INTEGER | read-write | Object to select the DTE Rate Adaption for the SC611 or DC621. |
| INT bql611DteOperation | 1.3.6.1.4.1.498.12.2.3.1.4 | INTEGER | read-write | Object to select the DTE Operation for the SC611 or DC621. |
| INT bql611TxClkSource | 1.3.6.1.4.1.498.12.2.3.1.5 | INTEGER | read-write | Object to select the Transmit Clock Source for the SC611 ONLY. |
| INT bql611WordLength | 1.3.6.1.4.1.498.12.2.3.1.6 | INTEGER | read-write | Object to select the Word Length for the SC611 or DC621 when selected
for async mode. |
| INT bql611OverSpeed | 1.3.6.1.4.1.498.12.2.3.1.7 | INTEGER | read-write | Object to select the Over Speed for the SC611 or DC621. |
| INT bql611RTS | 1.3.6.1.4.1.498.12.2.3.1.8 | INTEGER | read-write | Object to select RTS for SC611 and DC621 only. |
| INT bql611RTSCTSDelay | 1.3.6.1.4.1.498.12.2.3.1.9 | INTEGER | read-write | Object to select RTS CTS Delay for SC611 and DC621. |
| INT bql611DCD | 1.3.6.1.4.1.498.12.2.3.1.10 | INTEGER | read-write | Object to select DCD for SC611 and DC621. |
| INT bql611RDL | 1.3.6.1.4.1.498.12.2.3.1.11 | INTEGER | read-write | Object to select the RDL respond for SC611 and DC621. |
| INT bql611RDLMethod | 1.3.6.1.4.1.498.12.2.3.1.12 | INTEGER | read-write | Object to select RDL Method for SC611 and DC621.
SC611 Valid Choices DC621 Valid Choices
=================== ===================
V54 V54
EOC PN127 |
| INT bql611RDLTimeout | 1.3.6.1.4.1.498.12.2.3.1.13 | INTEGER | read-write | Object to select RDL Timeout for SC611 or DC621. |
| INT bql611TestPattern | 1.3.6.1.4.1.498.12.2.3.1.14 | INTEGER | read-write | Object to Test Pattern for SC611 and DC621. |
| bql611DiagnosticTable | 1.3.6.1.4.1.498.12.2.4 | | not-accessible | The GDC SC611/DC621 diagnostics table. |
| bql611DiagnosticEntry | 1.3.6.1.4.1.498.12.2.4.1 | | not-accessible | A listing of GDC SC611/DC621 diagnostic tests |
| SCI bql611DiagnosticIndex | 1.3.6.1.4.1.498.12.2.4.1.1 | SCinstance | read-only | A unique index for the Diagnostic Table. |
| INT bql611DiagnosticTest | 1.3.6.1.4.1.498.12.2.4.1.2 | INTEGER | read-write | This function selects or reads the test.
0 = no test currently operating
1 = remote loopback test
2 = channel loopback test
4 = data loopback test
8 = selftest
16 = line loopback test
32 = terminate test
All other values are test combinations such as
9 = selftest and remote loopback. |
| INT bql611DiagnosticActive | 1.3.6.1.4.1.498.12.2.4.1.3 | INTEGER | read-only | This function represents the test condition. |
| INT bql611DiagnosticResults | 1.3.6.1.4.1.498.12.2.4.1.4 | INTEGER | read-only | This function reads the self test results in
bit errors. |
| INT bql611DiagnosticResetErrorCount | 1.3.6.1.4.1.498.12.2.4.1.5 | INTEGER | read-write | Object to reset selftest error count during diagnostic
self testing for SC611 and DC621. |
| bql611ControlTable | 1.3.6.1.4.1.498.12.2.5 | | not-accessible | The GDC SC611 and DC621 Control Table. |
| bql611ControlEntry | 1.3.6.1.4.1.498.12.2.5.1 | | not-accessible | An entry in the GDC SC611/DC621 Control table. |
| SCI bql611ControlIndex | 1.3.6.1.4.1.498.12.2.5.1.1 | SCinstance | read-only | This object is the identifier of the SC611/DC621 Control table. |
| INT bql611SoftReset | 1.3.6.1.4.1.498.12.2.5.1.2 | INTEGER | read-write | Forces a soft reset on the network element.
The reset selection is write only. The normal
selection is read only. |
| INT bql611EraseConfig | 1.3.6.1.4.1.498.12.2.5.1.3 | INTEGER | read-write | Forces an erase of the stored configuration in the
network element. The erase selection is write only.
The normal selection is read only. |
| INT bql611FrontPanel | 1.3.6.1.4.1.498.12.2.5.1.4 | INTEGER | read-write | Object used to enable or disable the units front panel
switches. |
| OCT bql611LEDStatus | 1.3.6.1.4.1.498.12.2.5.1.5 | OCTET STRING | read-only | The GDC SC611 front panel LED Status.
A value of 1 means on, 0 is off.
byte 1 bit 7 (1.7) - not used
1.6 - not used
1.5 - not used
1.4 - test mode
1.3 - alarm transitions
1.2 - self test
1.1 - line loopback
1.0 - remote loopback
2.7 - not used
2.6 - not used
2.5 - not used
2.4 - not used
2.3 - send data transitions
2.2 - receive data transitions
2.1 - request to send
2.0 - data carrier detect
3.7 - not used
3.6 - not used
3.5 - not used
3.4 - not used
3.3 - not used
3.2 - not used
3.1 - not used
3.0 - not used |
| OCT bql621LEDStatus | 1.3.6.1.4.1.498.12.2.5.1.6 | OCTET STRING | read-only | The GDC DC621 front panel LED Status.
A value of 1 means on, 0 is off.
byte 1 bit 7 (1.7) - not used
1.6 - test mode
1.5 - sync
1.4 - request to send
1.3 - clear to send
1.2 - carrier
1.1 - send data transitions
1.0 - receive data transitions
2.7 - not used
2.6 - not used
2.5 - not used
2.4 - not used
2.3 - not used
2.2 - not used
2.1 - not used
2.0 - not used
3.7 - not used
3.6 - not used
3.5 - not used
3.4 - not used
3.3 - not used
3.2 - not used
3.1 - not used
3.0 - not used |
| bql611CurrentTable | 1.3.6.1.4.1.498.12.2.6 | | not-accessible | The SC611/DC621 Current table. |
| bql611CurrentEntry | 1.3.6.1.4.1.498.12.2.6.1 | | not-accessible | An entry in the SC611/DC621 Current table. |
| SCI bql611CurrentIndex | 1.3.6.1.4.1.498.12.2.6.1.1 | SCinstance | read-only | The index value which uniquely identifies the
SC611 interface to which this entry
is applicable. |
| OCT bql611CurrentStats | 1.3.6.1.4.1.498.12.2.6.1.2 | OCTET STRING | read-only | The number of Errored Seconds, Severely Errored Seconds &
Unavailable Errored Seconds encountered by
an ISDN interface in the current 15 minute interval. |
| bql611IntervalTable | 1.3.6.1.4.1.498.12.2.8 | | not-accessible | The SC611/DC621 Interval table. |
| bql611IntervalEntry | 1.3.6.1.4.1.498.12.2.8.1 | | not-accessible | An entry in the SC611/DC621 Interval table. |
| SCI bql611IntervalIndex | 1.3.6.1.4.1.498.12.2.8.1.1 | SCinstance | read-only | The index value which uniquely identifies the
ISDN interface to which this entry is applicable. |
| INT bql611IntervalNumber | 1.3.6.1.4.1.498.12.2.8.1.2 | INTEGER | read-only | A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minute inter-
val (assuming that all 96 intervals are
valid). |
| OCT bql611IntervalStats | 1.3.6.1.4.1.498.12.2.8.1.3 | OCTET STRING | read-only | The number of Errored Seconds, Severely Errored Seconds and
Unavailable Errored Seconds encountered by a DS1 interface in one of the
previous 96, individual 15 minute, intervals. |
| bql611TotalTable | 1.3.6.1.4.1.498.12.2.9 | | not-accessible | The SC611/DC621 Total table. 24 hour interval. |
| bql611TotalEntry | 1.3.6.1.4.1.498.12.2.9.1 | | not-accessible | An entry in the SC611/DC621 Total table. |
| SCI bql611TotalIndex | 1.3.6.1.4.1.498.12.2.9.1.1 | SCinstance | read-only | The index value which uniquely identifies the
ISDN interface to which this entry is applicable. |
| OCT bql611TotalStats | 1.3.6.1.4.1.498.12.2.9.1.2 | OCTET STRING | read-only | The number of Errored Seconds,Severely Errored Seconds & Unavailable Errored
Seconds encountered by an ISDN interface in the previous 24 hour interval. |
| bql611IntervalMaintenanceTable | 1.3.6.1.4.1.498.12.2.10 | | not-accessible | The SC611, DC621 Loop Interval Maintenance table. |
| bql611IntervalMaintenanceEntry | 1.3.6.1.4.1.498.12.2.10.1 | | not-accessible | The SC611, DC621 Interval Maintenance table entry. |
| SCI bql611IntervalMaintenanceIndex | 1.3.6.1.4.1.498.12.2.10.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to
which this entry is applicable. This has the form of a
SCinstance which defines the slot, line, drop, and interface,
which in this case is a Loop interface. |
| INT bql611ResetIntervals | 1.3.6.1.4.1.498.12.2.10.1.2 | INTEGER | read-write | This variable is used to reset Loop performance intervals.
When it is set to reset, the Loop performance tables are
reset to zero. |
| INT bql611NumberofValidIntervals | 1.3.6.1.4.1.498.12.2.10.1.3 | INTEGER | read-only | This variable is used to read the number of intervals collected.
Each interval is an increment of 15 minutes. |
| INT bql611ResetMajorAlarm | 1.3.6.1.4.1.498.12.2.10.1.4 | INTEGER | read-write | This variable is used to reset alarm per Loop basis. |
| INT bql611ResetMinorAlarm | 1.3.6.1.4.1.498.12.2.10.1.5 | INTEGER | read-write | This variable is used to reset alarm per Loop basis. |
| bql621 | 1.3.6.1.4.1.498.12.3 | | | |
| bql611Alarm | 1.3.6.1.4.1.498.12.9 | | | |
| bql611AlarmData | 1.3.6.1.4.1.498.12.9.1 | | | |
| bql611NoResponseAlm | 1.3.6.1.4.1.498.12.9.1.1 | | | |
| bql611DiagRxErrAlm | 1.3.6.1.4.1.498.12.9.1.2 | | | |
| bql611PowerUpAlm | 1.3.6.1.4.1.498.12.9.1.3 | | | |
| bql611OutofSyncAlm | 1.3.6.1.4.1.498.12.9.1.4 | | | |
| bql611TxClkOutOfToleranceAlm | 1.3.6.1.4.1.498.12.9.1.5 | | | |
| bql611ExtClkAbsentAlm | 1.3.6.1.4.1.498.12.9.1.6 | | | |
| bql611SealingCurrentNoContinuityAlm | 1.3.6.1.4.1.498.12.9.1.7 | | | |
| bql611DtrNotPresentAlm | 1.3.6.1.4.1.498.12.9.1.8 | | | |
| bql611MajorAlarmBERAlm | 1.3.6.1.4.1.498.12.9.1.9 | | | |
| bql611MinorAlarmBERAlm | 1.3.6.1.4.1.498.12.9.1.10 | | | |
| bql611AlarmConfigTable | 1.3.6.1.4.1.498.12.9.2 | | not-accessible | The bql611AlarmConfigTable contains entries that configure alarm
reporting. The structure of the table is such that alarm
configuration is supported on a unit and interface basis, and
then on an alarm type basis within the interface. For
simplicity sake alarms, be they unit or interface
related, are represented in one table. |
| bql611AlarmConfigEntry | 1.3.6.1.4.1.498.12.9.2.1 | | not-accessible | An entry in the bql611AlarmConfigTable table. |
| SCI bql611AlarmConfigIndex | 1.3.6.1.4.1.498.12.9.2.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to
which this entry is applicable. |
| OID bql611AlarmConfigIdentifier | 1.3.6.1.4.1.498.12.9.2.1.2 | OBJECT IDENTIFIER | read-only | The unique alarm identifier assigned to this alarm type.
The format of this identifier is an OBJECT IDENTIFIER that has
the following format: {iso(1) org(3) dod(6) internet(1)
private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y)
where xxx(x) is the administratively assigned family object
identifier (z) is the object identifier for alarms in the family
defined MIB and yyy(y) is the administratively assigned alarm
type identifier for this alarm. |
| INT bql611AlarmThreshold | 1.3.6.1.4.1.498.12.9.2.1.3 | INTEGER | read-write | This function sets/reads the Major or Minor BER alarm threshold criteria for a SC611 or DC621. |
| bql621Alarm | 1.3.6.1.4.1.498.12.11 | | | |
| bql621AlarmData | 1.3.6.1.4.1.498.12.11.1 | | | |
| bql621NoResponseAlm | 1.3.6.1.4.1.498.12.11.1.1 | | | |
| bql621DiagRxErrAlm | 1.3.6.1.4.1.498.12.11.1.2 | | | |
| bql621PowerUpAlm | 1.3.6.1.4.1.498.12.11.1.3 | | | |
| bql621DtrNotPresentAlm | 1.3.6.1.4.1.498.12.11.1.4 | | | |
| bql621MajorAlarmBERAlm | 1.3.6.1.4.1.498.12.11.1.5 | | | |
| bql621MinorAlarmBERAlm | 1.3.6.1.4.1.498.12.11.1.6 | | | |