All MIBs › GDCSC611-MIB › bql611RTS
bql611RTS
Module: GDCSC611-MIB
OID (symbolic): GDCSC611-MIB::bql611RTS
OID (numeric): 1.3.6.1.4.1.498.12.2.3.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Object to select RTS for SC611 and DC621 only.
What is bql611RTS?
Sets whether Request To Send behaves normal(1)ly (following the DTE's RTS lead) or is force(2)d permanently active, a mode admins use when the attached DTE doesn't properly toggle RTS itself.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.12.2.3.1.8 snmpwalk -v2c -c public <target> GDCSC611-MIB::bql611RTS
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.12.2.3.1.8.1 snmpget -v2c -c public <target> GDCSC611-MIB::bql611RTS.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.12.2.3.1.8.1 i <value>
Start monitoring General DataComm (GDC) SC611 shelf controller/access multiplexer shelf with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCSC611-MIB::bql611RTS OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) SC611 shelf controller/access multiplexer shelf from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | DMA200-MIB |
| 1.3.6.1.4.1.498.12 | bql2 | GDC7616-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.12.2 | bql611 | GDCSC611-MIB |
| 1.3.6.1.4.1.498.12.2.3 | bql611ConfigTable | GDCSC611-MIB |
| 1.3.6.1.4.1.498.12.2.3.1 | bql611ConfigEntry | GDCSC611-MIB |
| 1.3.6.1.4.1.498.12.2.3.1.8 | bql611RTS | GDCSC611-MIB |