All MIBs › GDCSC611-MIB › bql611RDL
bql611RDL
Module: GDCSC611-MIB
OID (symbolic): GDCSC611-MIB::bql611RDL
OID (numeric): 1.3.6.1.4.1.498.12.2.3.1.11
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Object to select the RDL respond for SC611 and DC621.
What is bql611RDL?
Enables or disables whether the unit will respond to a remote digital loopback (RDL) request from the far end, which an admin disables on production circuits to prevent an unauthorized remote loop from taking the line down.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.12.2.3.1.11 snmpwalk -v2c -c public <target> GDCSC611-MIB::bql611RDL
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.12.2.3.1.11.1 snmpget -v2c -c public <target> GDCSC611-MIB::bql611RDL.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.12.2.3.1.11.1 i <value>
Start monitoring General DataComm (GDC) SC611 shelf controller/access multiplexer shelf with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCSC611-MIB::bql611RDL OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) SC611 shelf controller/access multiplexer shelf from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | DMA200-MIB |
| 1.3.6.1.4.1.498.12 | bql2 | GDC7616-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.12.2 | bql611 | GDCSC611-MIB |
| 1.3.6.1.4.1.498.12.2.3 | bql611ConfigTable | GDCSC611-MIB |
| 1.3.6.1.4.1.498.12.2.3.1 | bql611ConfigEntry | GDCSC611-MIB |
| 1.3.6.1.4.1.498.12.2.3.1.11 | bql611RDL | GDCSC611-MIB |