-- Copyright 1996 General DataComm Ind., Inc. All Rights Reserved. -- -- Reproduction of this document is authorized on condition that the -- foregoing copyright notice is included. This General DataComm, GDC, -- SNMP Management Information Base Specification embodies GDCs' -- confidential and proprietary intellectual property. GDC retains all -- title and ownership in the Specification, including any revisions. -- -- It is GDCs intent to encourage the widespread use of this Specification -- in connection with the management of GDC's products. GDC grants vendors, -- end-users, and other interested parties a non-exclusive license to use -- this Specification in connection with the management of GDC's products. -- -- This Specification is supplied "AS IS," and GDC makes no warranty, -- either expressed or implied, as to the use operation, condition, or -- performance of the Specification. -- -- Revision History -- -- Version Date Name Description -- 1.00A 08-Dec-95 M. Cyr Initial Revision -- 1.00B 13-Mar-96 E. Moreno-Leon Added Major and Minor BER Alarms -- 1.00C 18-Mar-96 E. Moreno-Leon Corrected value for DTE data rate GDCSC611-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 SCinstance FROM GDCMACRO-MIB; gdc OBJECT IDENTIFIER ::= { enterprises 498 } bql2 OBJECT IDENTIFIER ::= { gdc 12 } bql611 OBJECT IDENTIFIER ::= { bql2 2 } bql621 OBJECT IDENTIFIER ::= { bql2 3 } -- This is the GDC MIB for SC611 and DC621 objects for ISDN 2B1Q. -- -- This MIB is only usable when the configuration is software controllable. -- -- See the GDC MIB requirements document to determine how the standard MIB's -- are supported. -- --***************************************************************************** -- SCinstance is defined as the addressing/indexing method of accessing -- table objects in this MIB. The SCinstance represents the SpectraComm -- shelf Slot, Line, Drop and interface address. -- Represented as SLDi, (Slot, Line, Drop, interface). -- The SC611 and DC621 only supports one loop and one DTE channel. -- -- SC611 DC621 -- ----- ----- -- SLDi SLDi -- L=1 L=1 -- D=0 D=XX Depends what is the local unit -- i=0 or 1 i=0 or 1 -- --***************************************************************************** --************************************************************************** -- GDC SC611 and DC621 - MIB VERSION NUMBER --************************************************************************** bql611MIBVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "The version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is a minor revision(0-9), z is a typo revision (0-9) and T indicates the MIB is still a test revision(A-Z). When a release is complete no T should exist." ::= { bql611 1 } --***************************************************************************** -- GDC SC611 and DC621 - WHAT ARE YOU TABLE --***************************************************************************** -- -- This table contains network element information indexed by SLDi. -- -- This table uses SCinstance defined as follows: -- SC611 DC621 -- ----- ----- -- SLDi SLDi -- L=1 L=1 -- D=0 D=XX Depends what is the local unit -- i=0 i=0 -- -- bql611WhatAreYouTable OBJECT-TYPE SYNTAX SEQUENCE OF Bql611WhatAreYouEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC SC611 and DC621 What Are You Table." ::= { bql611 2 } bql611WhatAreYouEntry OBJECT-TYPE SYNTAX Bql611WhatAreYouEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC SC611 What Are You table." INDEX { bql611WhatAreYouIndex } ::= { bql611WhatAreYouTable 1 } Bql611WhatAreYouEntry ::= SEQUENCE { bql611WhatAreYouIndex SCinstance, bql611BaseCardType INTEGER, bql611OptionCard INTEGER, bql611DTECardType INTEGER, bql611CodeRev DisplayString, bql611AlarmStatus OCTET STRING } bql611WhatAreYouIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "This object is the identifier of the SC611/DC621 What Are You table." ::= { bql611WhatAreYouEntry 1 } bql611BaseCardType OBJECT-TYPE SYNTAX INTEGER { sc611(5), dc621(7) } ACCESS read-only STATUS mandatory DESCRIPTION "This function returns the value the Base Card Type." ::= { bql611WhatAreYouEntry 2 } bql611OptionCard OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), installed(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates whether the option card is installed or not on the DC621." ::= { bql611WhatAreYouEntry 3 } bql611DTECardType OBJECT-TYPE SYNTAX INTEGER { eia530(1), x21(2), none(7) } ACCESS read-only STATUS mandatory DESCRIPTION "This object is the DTE plug-in card type. This variable is used for a SC611 or DC621." ::= { bql611WhatAreYouEntry 4 } bql611CodeRev OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) ACCESS read-only STATUS mandatory DESCRIPTION "This function returns the firmware code level. Example A- ,B- " ::= { bql611WhatAreYouEntry 5 } bql611AlarmStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The current alarms of the unit without the alarm masks." ::= { bql611WhatAreYouEntry 6 } --***************************************************************************** -- CONFIGURATION TABLE --***************************************************************************** -- -- This table contains the network element's configuration information indexed by -- SLDi and channel. -- -- This table uses SCinstance defined as follows: -- SC611 DC621 -- ----- ----- -- SLDi SLDi -- L=1 L=1 -- D=0 D=XX Depends what is the local unit -- i=1 i=1 bql611ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Bql611ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC SC611, DC621 2B1Q configuration table." ::= { bql611 3 } bql611ConfigEntry OBJECT-TYPE SYNTAX Bql611ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A listing of GDC 2B1Q SC611/DC621 options." INDEX { bql611ConfigIndex } ::= { bql611ConfigTable 1 } Bql611ConfigEntry ::= SEQUENCE { bql611ConfigIndex SCinstance, bql611DteRate INTEGER, bql611RateAdaption INTEGER, bql611DteOperation INTEGER, bql611TxClkSource INTEGER, bql611WordLength INTEGER, bql611OverSpeed INTEGER, bql611RTS INTEGER, bql611RTSCTSDelay INTEGER, bql611DCD INTEGER, bql611RDL INTEGER, bql611RDLMethod INTEGER, bql611RDLTimeout INTEGER, bql611TestPattern INTEGER } bql611ConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "A unique index for the Configuration Table." ::= { bql611ConfigEntry 1 } bql611DteRate OBJECT-TYPE SYNTAX INTEGER { kBps2Dot4(1), kBps4Dot8(2), kBps9Dot6(3), kBps19Dot2(4), kBps48(6), kBps64(9), kBps128(10) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select the DTE rate for the SC611 or DC621." ::= { bql611ConfigEntry 2 } bql611RateAdaption OBJECT-TYPE SYNTAX INTEGER { x50Div3(1), x50Div2(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select the DTE Rate Adaption for the SC611 or DC621." ::= { bql611ConfigEntry 3 } bql611DteOperation OBJECT-TYPE SYNTAX INTEGER { sync(1), async(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select the DTE Operation for the SC611 or DC621." ::= { bql611ConfigEntry 4 } bql611TxClkSource OBJECT-TYPE SYNTAX INTEGER { internal(1), external(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select the Transmit Clock Source for the SC611 ONLY." ::= { bql611ConfigEntry 5 } bql611WordLength OBJECT-TYPE SYNTAX INTEGER { bitWord8(1), bitWord9(2), bitWord10(3), bitWord11(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select the Word Length for the SC611 or DC621 when selected for async mode." ::= { bql611ConfigEntry 6 } bql611OverSpeed OBJECT-TYPE SYNTAX INTEGER { onePercent(1), twoPointThreePercent(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select the Over Speed for the SC611 or DC621." ::= { bql611ConfigEntry 7 } bql611RTS OBJECT-TYPE SYNTAX INTEGER { normal(1), force(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select RTS for SC611 and DC621 only." ::= { bql611ConfigEntry 8 } bql611RTSCTSDelay OBJECT-TYPE SYNTAX INTEGER { noDelay(1), delay(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select RTS CTS Delay for SC611 and DC621." ::= { bql611ConfigEntry 9 } bql611DCD OBJECT-TYPE SYNTAX INTEGER { normal(1), inBandRTS(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select DCD for SC611 and DC621." ::= { bql611ConfigEntry 10 } bql611RDL OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select the RDL respond for SC611 and DC621." ::= { bql611ConfigEntry 11 } bql611RDLMethod OBJECT-TYPE SYNTAX INTEGER { v54(1), eocorpn127(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select RDL Method for SC611 and DC621. SC611 Valid Choices DC621 Valid Choices =================== =================== V54 V54 EOC PN127" ::= { bql611ConfigEntry 12 } bql611RDLTimeout OBJECT-TYPE SYNTAX INTEGER { none(1), minutes10(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to select RDL Timeout for SC611 or DC621." ::= { bql611ConfigEntry 13 } bql611TestPattern OBJECT-TYPE SYNTAX INTEGER { pattern2047(1), pattern511(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to Test Pattern for SC611 and DC621." ::= { bql611ConfigEntry 14 } --***************************************************************************** -- DIAGNOSTICS TABLE --***************************************************************************** -- -- This table contains the network element's diagnostic test information indexed by -- SLDi and channel. -- -- This table uses SCinstance defined as follows: -- SC611 DC621 -- ----- ----- -- SLDi SLDi -- L=1 L=1 -- D=0 D=XX Depends what is the local unit -- i=1 i=1 bql611DiagnosticTable OBJECT-TYPE SYNTAX SEQUENCE OF Bql611DiagnosticEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC SC611/DC621 diagnostics table." ::= { bql611 4 } bql611DiagnosticEntry OBJECT-TYPE SYNTAX Bql611DiagnosticEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A listing of GDC SC611/DC621 diagnostic tests" INDEX { bql611DiagnosticIndex } ::= { bql611DiagnosticTable 1 } Bql611DiagnosticEntry ::= SEQUENCE { bql611DiagnosticIndex SCinstance, bql611DiagnosticTest INTEGER, bql611DiagnosticActive INTEGER, bql611DiagnosticResults INTEGER, bql611DiagnosticResetErrorCount INTEGER } bql611DiagnosticIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "A unique index for the Diagnostic Table." ::= { bql611DiagnosticEntry 1 } bql611DiagnosticTest OBJECT-TYPE SYNTAX INTEGER (0..63) ACCESS read-write STATUS mandatory DESCRIPTION "This function selects or reads the test. 0 = no test currently operating 1 = remote loopback test 2 = channel loopback test 4 = data loopback test 8 = selftest 16 = line loopback test 32 = terminate test All other values are test combinations such as 9 = selftest and remote loopback." ::= { bql611DiagnosticEntry 2 } bql611DiagnosticActive OBJECT-TYPE SYNTAX INTEGER { notActive (1), active (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This function represents the test condition." ::= { bql611DiagnosticEntry 3 } bql611DiagnosticResults OBJECT-TYPE SYNTAX INTEGER (0..16383) ACCESS read-only STATUS mandatory DESCRIPTION "This function reads the self test results in bit errors." ::= { bql611DiagnosticEntry 4 } bql611DiagnosticResetErrorCount OBJECT-TYPE SYNTAX INTEGER { normal(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object to reset selftest error count during diagnostic self testing for SC611 and DC621." ::= { bql611DiagnosticEntry 5 } --******************************************************************************** -- ALARMS SC611 2B1Q - INDIVIDUALLY IDENTIFIED FOR THE CONTROLLER --******************************************************************************** bql611Alarm OBJECT IDENTIFIER ::= { bql2 9 } bql611AlarmData OBJECT IDENTIFIER ::= { bql611Alarm 1 } -- no response alarm (this is a SCM generated alarm) bql611NoResponseAlm OBJECT IDENTIFIER ::= { bql611AlarmData 1 } -- no diagnostic receive error alarm (this is a SCM generated alarm) bql611DiagRxErrAlm OBJECT IDENTIFIER ::= { bql611AlarmData 2 } -- power up alarm bql611PowerUpAlm OBJECT IDENTIFIER ::= { bql611AlarmData 3 } -- out of sync alarm bql611OutofSyncAlm OBJECT IDENTIFIER ::= { bql611AlarmData 4 } -- tx clock out of tolerance bql611TxClkOutOfToleranceAlm OBJECT IDENTIFIER ::= { bql611AlarmData 5 } -- external transmit clock absent bql611ExtClkAbsentAlm OBJECT IDENTIFIER ::= { bql611AlarmData 6 } -- sealing current no continuity bql611SealingCurrentNoContinuityAlm OBJECT IDENTIFIER ::= { bql611AlarmData 7 } -- dtr not present alarm bql611DtrNotPresentAlm OBJECT IDENTIFIER ::= { bql611AlarmData 8 } -- Major BER alarm bql611MajorAlarmBERAlm OBJECT IDENTIFIER ::= { bql611AlarmData 9 } -- Minor BER alarm bql611MinorAlarmBERAlm OBJECT IDENTIFIER ::= { bql611AlarmData 10 } -- ALARM Maskable Valid interfaces Threshold -- ========================================================================= -- bql611NoResponseAlm no unit no -- bql611DiagRxErrAlm no unit no -- bql611PowerUpAlm no unit no -- bql611OutofSyncAlm yes loop 1 no -- bql611TxClkOutOfToleranceAlm yes loop 1 no -- bql611ExtClkAbsentAlm yes loop 1 no -- bql611SealingCurrentNoContinuityAlm yes loop 1 no -- bql611DtrNotPresentAlm yes loop 1 no -- bql611MajorAlarmBERAlm yes loop 1 yes -- bql611MinorAlarmBERAlm yes loop 1 yes --******************************************************************************** -- ALARMS DC621 2B1Q - INDIVIDUALLY IDENTIFIED FOR THE CONTROLLER --******************************************************************************** bql621Alarm OBJECT IDENTIFIER ::= { bql2 11 } bql621AlarmData OBJECT IDENTIFIER ::= { bql621Alarm 1 } -- no response alarm (this is a SCM generated alarm) bql621NoResponseAlm OBJECT IDENTIFIER ::= { bql621AlarmData 1 } -- no diagnostic receive error alarm (this is a SCM generated alarm) bql621DiagRxErrAlm OBJECT IDENTIFIER ::= { bql621AlarmData 2 } -- power up alarm bql621PowerUpAlm OBJECT IDENTIFIER ::= { bql621AlarmData 3 } -- dtr not present alarm bql621DtrNotPresentAlm OBJECT IDENTIFIER ::= { bql621AlarmData 4 } -- Major BER alarm bql621MajorAlarmBERAlm OBJECT IDENTIFIER ::= { bql621AlarmData 5 } -- Minor BER alarm bql621MinorAlarmBERAlm OBJECT IDENTIFIER ::= { bql621AlarmData 6 } -- ALARM Maskable Valid interfaces Threshold -- ========================================================================= -- bql621NoResponseAlm no unit no -- bql621DiagRxErrAlm no unit no -- bql621PowerUpAlm no unit no -- bql621DtrNotPresentAlm yes loop 1 no -- bql621MajorAlarmBERAlm yes loop 1 yes -- bql621MinorAlarmBERAlm yes loop 1 yes --***************************************************************************** -- Alarm Config Table FOR SC621 and DC611. --***************************************************************************** bql611AlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Bql611AlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The bql611AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table." ::= { bql611Alarm 2 } bql611AlarmConfigEntry OBJECT-TYPE SYNTAX Bql611AlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the bql611AlarmConfigTable table." INDEX { bql611AlarmConfigIndex, bql611AlarmConfigIdentifier } ::= { bql611AlarmConfigTable 1 } Bql611AlarmConfigEntry ::= SEQUENCE { bql611AlarmConfigIndex SCinstance, bql611AlarmConfigIdentifier OBJECT IDENTIFIER, bql611AlarmThreshold INTEGER } bql611AlarmConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable." ::= { bql611AlarmConfigEntry 1 } bql611AlarmConfigIdentifier OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm." ::= { bql611AlarmConfigEntry 2 } bql611AlarmThreshold OBJECT-TYPE SYNTAX INTEGER { thres10E03(1), thres10E04(2), thres10E05(3), thres10E06(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This function sets/reads the Major or Minor BER alarm threshold criteria for a SC611 or DC621." ::= { bql611AlarmConfigEntry 3 } --***************************************************************************** -- CONTROL TABLE FOR 2B1Q SC611 and DC621 --***************************************************************************** -- -- This table contains the SC611 and DC621 control functions indexed by -- SLDi. -- -- This table uses SCinstance defined as follows: -- SC611 DC621 -- ----- ----- -- SLDi SLDi -- L=1 L=1 -- D=0 D=XX Depends what is the local unit -- i=0 i=0 bql611ControlTable OBJECT-TYPE SYNTAX SEQUENCE OF Bql611ControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC SC611 and DC621 Control Table." ::= { bql611 5 } bql611ControlEntry OBJECT-TYPE SYNTAX Bql611ControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC SC611/DC621 Control table." INDEX { bql611ControlIndex } ::= { bql611ControlTable 1 } Bql611ControlEntry ::= SEQUENCE { bql611ControlIndex SCinstance, bql611SoftReset INTEGER, bql611EraseConfig INTEGER, bql611FrontPanel INTEGER, bql611LEDStatus OCTET STRING, bql621LEDStatus OCTET STRING } bql611ControlIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "This object is the identifier of the SC611/DC621 Control table." ::= { bql611ControlEntry 1 } bql611SoftReset OBJECT-TYPE SYNTAX INTEGER { normal(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Forces a soft reset on the network element. The reset selection is write only. The normal selection is read only." ::= { bql611ControlEntry 2 } bql611EraseConfig OBJECT-TYPE SYNTAX INTEGER { normal(1), erase(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Forces an erase of the stored configuration in the network element. The erase selection is write only. The normal selection is read only." ::= { bql611ControlEntry 3 } bql611FrontPanel OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Object used to enable or disable the units front panel switches." ::= { bql611ControlEntry 4 } bql611LEDStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3)) ACCESS read-only STATUS mandatory DESCRIPTION "The GDC SC611 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - not used 1.5 - not used 1.4 - test mode 1.3 - alarm transitions 1.2 - self test 1.1 - line loopback 1.0 - remote loopback 2.7 - not used 2.6 - not used 2.5 - not used 2.4 - not used 2.3 - send data transitions 2.2 - receive data transitions 2.1 - request to send 2.0 - data carrier detect 3.7 - not used 3.6 - not used 3.5 - not used 3.4 - not used 3.3 - not used 3.2 - not used 3.1 - not used 3.0 - not used" ::= { bql611ControlEntry 5 } bql621LEDStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE (3)) ACCESS read-only STATUS mandatory DESCRIPTION "The GDC DC621 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - sync 1.4 - request to send 1.3 - clear to send 1.2 - carrier 1.1 - send data transitions 1.0 - receive data transitions 2.7 - not used 2.6 - not used 2.5 - not used 2.4 - not used 2.3 - not used 2.2 - not used 2.1 - not used 2.0 - not used 3.7 - not used 3.6 - not used 3.5 - not used 3.4 - not used 3.3 - not used 3.2 - not used 3.1 - not used 3.0 - not used" ::= { bql611ControlEntry 6 } --***************************************************************************** -- STATISTICS TABLE - CURRENT 15 MINUTE INTERVAL TABLE --***************************************************************************** -- -- The SC611/DC621 current table contains various statistics being -- collected for the current 15 minute interval. -- It is indexed by SLDi. -- -- This table uses SCinstance defined as follows: -- SC611 DC621 -- ----- ----- -- SLDi SLDi -- L=1 L=1 -- D=0 D=XX Depends what is the local unit -- i=1 i=1 bql611CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Bql611CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SC611/DC621 Current table." ::= { bql611 6 } bql611CurrentEntry OBJECT-TYPE SYNTAX Bql611CurrentEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the SC611/DC621 Current table." INDEX { bql611CurrentIndex } ::= { bql611CurrentTable 1 } Bql611CurrentEntry ::= SEQUENCE { bql611CurrentIndex SCinstance, bql611CurrentStats OCTET STRING } bql611CurrentIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the SC611 interface to which this entry is applicable." ::= { bql611CurrentEntry 1 } bql611CurrentStats OBJECT-TYPE SYNTAX OCTET STRING (SIZE (12)) ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds, Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the current 15 minute interval." ::= { bql611CurrentEntry 2 } --***************************************************************************** -- STATISTICS TABLE - 15 MINUTE INTERVAL TABLE --***************************************************************************** -- -- The SC611/DC621 Interval Table contains various statistics -- collected by each ISDN Interface over the previous 24 hours of -- operation. The past 24 hours are broken into 96 completed -- 15 minute intervals. This table is indexed by SLDi and Interval Number. -- -- This table uses SCinstance defined as follows: -- SC611 DC621 -- ----- ----- -- SLDi SLDi -- L=1 L=1 -- D=0 D=XX Depends what is the local unit -- i=1 i=1 -- -- and Interval Number is a number between 1 and 96. -- Where 1 is the most recently completed 15 minute -- interval and 96 is the least recently completed 15 minute interval. -- bql611IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Bql611IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SC611/DC621 Interval table." ::= { bql611 8 } bql611IntervalEntry OBJECT-TYPE SYNTAX Bql611IntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the SC611/DC621 Interval table." INDEX { bql611IntervalIndex, bql611IntervalNumber } ::= { bql611IntervalTable 1 } Bql611IntervalEntry ::= SEQUENCE { bql611IntervalIndex SCinstance, bql611IntervalNumber INTEGER, bql611IntervalStats OCTET STRING } bql611IntervalIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the ISDN interface to which this entry is applicable." ::= { bql611IntervalEntry 1 } bql611IntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minute inter- val (assuming that all 96 intervals are valid)." ::= { bql611IntervalEntry 2 } bql611IntervalStats OBJECT-TYPE SYNTAX OCTET STRING (SIZE (12)) ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds, Severely Errored Seconds and Unavailable Errored Seconds encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals." ::= { bql611IntervalEntry 3 } --***************************************************************************** -- STATISTICS TABLE - TOTAL OF INTERVALS TABLE --***************************************************************************** -- -- The SC611/DC621 Total Table contains the cumulative sum of the -- various statistics for the 24 hour period preceding the -- current interval. It is indexed by SLDi. -- -- This table uses SCinstance defined as follows: -- SC611 DC621 -- ----- ----- -- SLDi SLDi -- L=1 L=1 -- D=0 D=XX Depends what is the local unit -- i=1 i=1 bql611TotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Bql611TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SC611/DC621 Total table. 24 hour interval." ::= { bql611 9 } bql611TotalEntry OBJECT-TYPE SYNTAX Bql611TotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the SC611/DC621 Total table." INDEX { bql611TotalIndex } ::= { bql611TotalTable 1 } Bql611TotalEntry ::= SEQUENCE { bql611TotalIndex SCinstance, bql611TotalStats OCTET STRING } bql611TotalIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the ISDN interface to which this entry is applicable." ::= { bql611TotalEntry 1 } bql611TotalStats OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds,Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the previous 24 hour interval." ::= { bql611TotalEntry 2 } --***************************************************************************** -- LOOP Performance Interval Maintenance Table FOR SC611 and DC621 --***************************************************************************** -- -- This table uses SCinstance defined as follows: -- SC611 DC621 -- ----- ----- -- SLDi SLDi -- L=1 L=1 -- D=0 D=XX Depends what is the local unit -- i=1 i=1 -- bql611IntervalMaintenanceTable OBJECT-TYPE SYNTAX SEQUENCE OF Bql611IntervalMaintenanceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SC611, DC621 Loop Interval Maintenance table. " ::= { bql611 10 } bql611IntervalMaintenanceEntry OBJECT-TYPE SYNTAX Bql611IntervalMaintenanceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SC611, DC621 Interval Maintenance table entry. " INDEX { bql611IntervalMaintenanceIndex } ::= { bql611IntervalMaintenanceTable 1 } Bql611IntervalMaintenanceEntry ::= SEQUENCE { bql611IntervalMaintenanceIndex SCinstance, bql611ResetIntervals INTEGER, bql611NumberofValidIntervals INTEGER, bql611ResetMajorAlarm INTEGER, bql611ResetMinorAlarm INTEGER } bql611IntervalMaintenanceIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface, which in this case is a Loop interface." ::= { bql611IntervalMaintenanceEntry 1 } bql611ResetIntervals OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION " This variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero." ::= { bql611IntervalMaintenanceEntry 2 } bql611NumberofValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) ACCESS read-only STATUS mandatory DESCRIPTION " This variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes." ::= { bql611IntervalMaintenanceEntry 3 } bql611ResetMajorAlarm OBJECT-TYPE SYNTAX INTEGER { reset(1), norm(2) } ACCESS read-write STATUS mandatory DESCRIPTION " This variable is used to reset alarm per Loop basis." ::= { bql611IntervalMaintenanceEntry 4 } bql611ResetMinorAlarm OBJECT-TYPE SYNTAX INTEGER { reset(1), norm(2) } ACCESS read-write STATUS mandatory DESCRIPTION " This variable is used to reset alarm per Loop basis." ::= { bql611IntervalMaintenanceEntry 5 } END