All MIBs › GDCMP7002-MIB
Category: Domain: WAN/TDM, Vendor: GDC
Description: General DataComm MP7002 multiport MIB for managing enhanced multi-port WAN concentrator configuration.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is GDCMP7002-MIB?
GDCMP7002-MIB is a General DataComm (GDC) enterprise MIB for the MP7002 multiport device, an enhanced multi-port WAN concentrator supporting E1-style (mp7002E1x) circuit aggregation. It exposes card/version inventory data (firmware revision, model number), per-line maintenance configuration, and a device uptime object, closely mirroring the structure of the related MP7001 MIB. Its monitoring role is centered on software/hardware status: administrators track firmware revisions (mp7002FirmwareRev) and model numbers (mp7002ModelNumber) per installed card for version/compliance auditing, monitor device uptime (mp7002SysUpTime) to catch unexpected restarts, and can issue a remote reset (mp7002SoftReset) as a recovery action, all of which reflect the unit's operational and software health rather than environmental sensors. As a sibling module to GDCMP7001-MIB, it likely reuses the same GDC enterprise OID conventions and general table design. It is typically deployed on General DataComm MP7002 WAN concentrators managing multiple E1 circuits in legacy telecom/enterprise WAN networks. Engineers can download the GDCMP7002-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in GDCMP7002-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General DataComm MP7002 multiport WAN concentrator
Monitoring Examples
An admin would poll mp7002VersionTable (keyed by mp7002VersionIndex) for mp7002FirmwareRev and mp7002ModelNumber across cards to identify any card running mismatched or outdated firmware. mp7002E1x settings would be checked for E1 circuit configuration, mp7002SysUpTime monitored for stability, and the mp7002MaintenanceTable (indexed by mp7002MaintenanceLineIndex) polled to check per-line maintenance state, with mp7002SoftReset available for remote recovery of a misbehaving line or unit.
What Can Be Monitored
- firmware revision per card
- model number inventory
- E1 circuit configuration
- device uptime
- per-line maintenance status
This MIB depends on
Related MIBs
Imported Objects
From GDCMACRO-MIB
| SCinstance |
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| enterprises |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| gdc | 1.3.6.1.4.1.498 | |||
| dsx1 | 1.3.6.1.4.1.498.6 | |||
| mp7002System | 1.3.6.1.4.1.498.6.6 | |||
| mp7002Version | 1.3.6.1.4.1.498.6.6.1 | |||
| STR mp7002MIBversion | 1.3.6.1.4.1.498.6.6.1.1 | DisplayString | read-only | Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Acceptable values for the individual revision components are as follows: x: 1 - 9 y: 0 - 9 z: 0 - 9 T: A - Z Upon formal release, no designation for the test revision will be present. |
| mp7002VersionTable | 1.3.6.1.4.1.498.6.6.1.2 | not-accessible | ||
| mp7002VersionEntry | 1.3.6.1.4.1.498.6.6.1.2.1 | not-accessible | An entry in the GDC Mp7002System Version Table. | |
| SCI mp7002VersionIndex | 1.3.6.1.4.1.498.6.6.1.2.1.1 | SCinstance | read-only | This object identifies Version parameters associated with the managed object. |
| STR mp7002FirmwareRev | 1.3.6.1.4.1.498.6.6.1.2.1.2 | DisplayString | read-only | The version number of the firmware, to allow products to know which revision is installed. The released version number is sequenced from --, A-, ... AA, ... ZZ. Test versions are numerical from 01 to 99. |
| STR mp7002ModelNumber | 1.3.6.1.4.1.498.6.6.1.2.1.3 | DisplayString | read-only | This variable is used to determine the type of card family installed ex. MP7002. |
| INT mp7002E1x | 1.3.6.1.4.1.498.6.6.1.2.1.4 | INTEGER | read-only | Indicates if the E1X Cascade Interface is installed. |
| mp7002Maintenance | 1.3.6.1.4.1.498.6.6.2 | |||
| mp7002MaintenanceTable | 1.3.6.1.4.1.498.6.6.2.1 | not-accessible | The table describes the maintenance objects for the unit and references the unit interface (cc = 00). | |
| mp7002MaintenanceEntry | 1.3.6.1.4.1.498.6.6.2.1.1 | not-accessible | An entry in the GDC E1 Maintenance Table. | |
| SCI mp7002MaintenanceLineIndex | 1.3.6.1.4.1.498.6.6.2.1.1.1 | SCinstance | read-only | This object identifies Maintenance parameters associated with the managed object. |
| INT mp7002SoftReset | 1.3.6.1.4.1.498.6.6.2.1.1.2 | INTEGER | read-write | Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose meaning is specific to the type of unit being managed. The value of norm(1) will be returned when the reset is complete. The value of norm(1) can not be set by management. |
| INT mp7002SysUpTime | 1.3.6.1.4.1.498.6.6.2.1.1.3 | INTEGER | read-only | This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count. |
| INT mp7002DefaultInit | 1.3.6.1.4.1.498.6.6.2.1.1.4 | INTEGER | read-write | This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(1) the unit will perform a reset to make the default configuration take affect. The value of normal(2) will be returned when the initialization is complete. The value of normal(2) can not be set by management. |
| INT mp7002ResetStats | 1.3.6.1.4.1.498.6.6.2.1.1.5 | INTEGER | read-write | Supports the action of soft resetting the mp7002NearEndValidIntervals object. When this object is set to reset(2), then the unit will reset the mp7002NearEndValidIntervals object to zero. The value of norm(1) can not be set by management. |
| OCT mp7002LedStatus | 1.3.6.1.4.1.498.6.6.2.1.1.6 | OCTET STRING | read-only | Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit 2 - NIU bit 1 - D_I bit 0 - future use Octet 2 bit 7 - not used bit 6 - future use bit 5 - NTWK AIS bit 4 - NTWK LCV bit 3 - NTWK LOS bit 2 - NTWK OOF bit 1 - ALM bit 0 - TM Octet 3 bit 7 - not used bit 6 - ST- future use bit 5 - LT- future use bit 4 - RL- future use bit 3 - future use bit 2 - future use bit 1 - future use bit 0 - future use |
| STR mp7002E1Circuit | 1.3.6.1.4.1.498.6.6.2.1.1.7 | DisplayString | read-write | Circuit name E1 is connected to. |
| STR mp7002E1XCircuit | 1.3.6.1.4.1.498.6.6.2.1.1.8 | DisplayString | read-write | Circuit Name E1X is connected to |
| STR mp7002TSBundle1Name | 1.3.6.1.4.1.498.6.6.2.1.1.9 | DisplayString | read-write | Name first Time Slot Bundle is assigned to. Only used when unit is configured for drop side interface |
| STR mp7002TSBundle2Name | 1.3.6.1.4.1.498.6.6.2.1.1.10 | DisplayString | read-write | Name second Time Slot Bundle is assigned to. Only used when unit is configured for drop side interface. |
| INT mp7002SetRealTime | 1.3.6.1.4.1.498.6.6.2.1.1.11 | INTEGER | read-write | Number of seconds from midnight Dec 31, 1969. |
| OCT mp7002AlarmStatus | 1.3.6.1.4.1.498.6.6.2.1.1.12 | OCTET STRING | read-only | Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NWTK_LOS bit 5 - NWTK_LOF bit 4 - NWTK_AIS bit 3 - NTWK_LCV bit 2 - TIMING LOSS bit 1 - NTWK_NE_ES bit 0 - NTWK_NE_BBE Octet 2 bit 7 - not used bit 6 - NTWK_NE_SES bit 5 - NTWK_NE_UAS bit 4 - NTWK_FE_ES bit 3 - NTWK_FE_BBE bit 2 - NTWK_FE_SES bit 1 - NTWK_FE_UAS bit 0 - NTWK_RAI Octet 3 bit 7 - not used bit 6 - E1X_LOS bit 5 - E1X_LOF bit 4 - E1X_AIS bit 3 - E1X_NE_ES bit 2 - E1X_NE_BBE bit 1 - E1X_NE_SES bit 0 - E1X_NE_UAS Octet 4 bit 7 - not used bit 6 - E1X_FE_ES bit 5 - E1X_FE_BBE bit 4 - E1X_FE_SES bit 3 - E1X_FE_UAS bit 2 - NVRAM corrupted bit 1 - unit failure bit 0 - Power-up Alarm |
| INT mp7002SystemTimingGenStatus | 1.3.6.1.4.1.498.6.6.2.1.1.13 | INTEGER | read-only | Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both. |
| INT mp7002FarEndResetStats | 1.3.6.1.4.1.498.6.6.2.1.1.14 | INTEGER | read-write | Supports the action of soft resetting the mp7002FarEndValidIntervals object. When this object is set to reset(2), then the unit will reset the mp7002FarEndValidIntervals object to zero. The value of norm(1) can not be set by management. |
| INT mp7002NearEndStatLastInitialized | 1.3.6.1.4.1.498.6.6.2.1.1.15 | INTEGER | read-only | Number of seconds from midnight Dec 31, 1969 up until mp7002NearEndValidIntervals was last initialized to zero |
| INT mp7002FarEndStatLastInitialized | 1.3.6.1.4.1.498.6.6.2.1.1.16 | INTEGER | read-only | Number of seconds from midnight Dec 31, 1969 up until mp7002FarEndValidIntervals was last initialized to zero |
| mp7002Configuration | 1.3.6.1.4.1.498.6.6.3 | |||
| mp7002ConfigTable | 1.3.6.1.4.1.498.6.6.3.1 | not-accessible | The GDC E1 Configuration table. | |
| mp7002ConfigEntry | 1.3.6.1.4.1.498.6.6.3.1.1 | not-accessible | The GDC E1 Configuration table entry. | |
| SCI mp7002ConfigIndex | 1.3.6.1.4.1.498.6.6.3.1.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| INT mp7002InterfaceType | 1.3.6.1.4.1.498.6.6.3.1.1.2 | INTEGER | read-write | The operating mode of the interface to be either Network Side, Drop Side or not assigned. |
| INT mp7002RcvrRange | 1.3.6.1.4.1.498.6.6.3.1.1.3 | INTEGER | read-write | Sets the receiver range to short (6dB) or long (36dB) |
| INT mp7002TransmitClockSource | 1.3.6.1.4.1.498.6.6.3.1.1.4 | INTEGER | read-write | Sets the transmit clock source. |
| INT mp7002FallbackClockSource | 1.3.6.1.4.1.498.6.6.3.1.1.5 | INTEGER | read-write | Identifies the fallback transmit clock source. |
| INT mp7002FacilityDataLink | 1.3.6.1.4.1.498.6.6.3.1.1.6 | INTEGER | read-write | |
| INT mp7002NearEndValidIntervals | 1.3.6.1.4.1.498.6.6.3.1.1.7 | INTEGER | read-only | The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. This object is only valid for the E1 interface. |
| INT mp7002FarEndValidIntervals | 1.3.6.1.4.1.498.6.6.3.1.1.8 | INTEGER | read-only | The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. This object is only valid for the E1 interface. |
| INT mp7002NetworkConnection | 1.3.6.1.4.1.498.6.6.3.1.1.9 | INTEGER | read-write | Sets whether the network interface is standby or online. This only applies to the Network Interface. |
| INT mp7002Framing | 1.3.6.1.4.1.498.6.6.3.1.1.10 | INTEGER | read-write | Set the framing for the interface. Abbreviations are as follows: CCS - common-channel signaling PCS0 - per channel signaling phase 0 PCS1 - per channel signaling phase 1 |
| INT mp7002LineCoding | 1.3.6.1.4.1.498.6.6.3.1.1.11 | INTEGER | read-write | Sets the line coding for the interface. |
| mp7002DCCConfigurationTable | 1.3.6.1.4.1.498.6.6.3.2 | not-accessible | The GDC DCC Configuration table. These are Diagnostic Channel configuration options. | |
| mp7002DCCConfigurationEntry | 1.3.6.1.4.1.498.6.6.3.2.1 | not-accessible | The GDC Diagnostic Configuration table entry. | |
| SCI mp7002DCCConfigurationIndex | 1.3.6.1.4.1.498.6.6.3.2.1.1 | SCinstance | read-only | Index value into the DCC Configuration table. |
| INT mp7002TimeSlot | 1.3.6.1.4.1.498.6.6.3.2.1.2 | INTEGER | read-write | Time Slot DCC goes in |
| INT mp7002Bandwidth | 1.3.6.1.4.1.498.6.6.3.2.1.3 | INTEGER | read-write | Bandwidth to use: 8 kbps - bit 7 only 56 kbps - bits 0 - 6 64 kbps - all 8 bits |
| mp7002Diagnostics | 1.3.6.1.4.1.498.6.6.4 | |||
| mp7002DiagTable | 1.3.6.1.4.1.498.6.6.4.1 | not-accessible | The GDC E1 Diagnostics table. Information in the entries of this table support diagnostics testing via loopbacks. Diagnostics are only supported when mp7002InterfaceType is set to niu(2). This table applies to the Network Interface only. | |
| mp7002DiagEntry | 1.3.6.1.4.1.498.6.6.4.1.1 | not-accessible | The GDC E1 Diagnostics table entry. | |
| SCI mp7002DiagIndex | 1.3.6.1.4.1.498.6.6.4.1.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| INT mp7002TestPattern | 1.3.6.1.4.1.498.6.6.4.1.1.2 | INTEGER | read-write | Test pattern for tests that use the pattern generator. The value of this object is used when mp7002DiagConfig.unitTest(5) or mp7002DiagConfig.patGenOn(6) is selected. NOT SUPPORTED BY THE MP7002. |
| INT mp7002DiagConfig | 1.3.6.1.4.1.498.6.6.4.1.1.3 | INTEGER | read-write | Selects the test to run. noLoop(1) ends the test. Interoperates with mp7002TestPattern. When unitTest(2) or patGenOn(3) is selected, the pattern in mp7002TestPattern is used. payloadLoopback(4) and lineLoopback(5) are only valid when the unit is configured for a Network Side interface. localTest(6) is only valid when the unit is configured for a Drop Side interface. |
| INT mp7002TestLimit | 1.3.6.1.4.1.498.6.6.4.1.1.4 | INTEGER | read-write | Selects the duration to run a diagnostic test. The value(1) noLimit signifies that the test should run indefinitely until explicitly terminated. Default value: testTime10Mins(1) |
| INT mp7002TestExecutionStatus | 1.3.6.1.4.1.498.6.6.4.1.1.5 | INTEGER | read-only | This variable reports the status of a test. notInTest(1) indicates a test is not running. testInProgress(2) indicates that a test is currently running. testCompleted(4) indicates that a test has run and is completed. testCompletedNotInTest(5) indicates that a test has completed and it is no longer in test. |
| INT mp7002TestExceptions | 1.3.6.1.4.1.498.6.6.4.1.1.6 | INTEGER | read-only | Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take the value zero. Then, for each exception, the value associated with the exception is added to the sum. The exception values are: value exception 1 a timed test was preempted so the result cannot be viewed in relation to the test duration 2 the results overflowed so the result cannot be viewed as an absolute value 4 the test was performed while synchronization could not be performed so the result may not be accurate. |
| INT mp7002TestResults | 1.3.6.1.4.1.498.6.6.4.1.1.7 | INTEGER | read-only | The results of the last diagnostic test. This can be the current test running or the last completed test. Note that the interpretation of these results may be affected by the value of the mp7002TestExceptions object. Not supported by MP7002 since no pattern generating tests are supported. |
| INT mp7002ResetTestResults | 1.3.6.1.4.1.498.6.6.4.1.1.8 | INTEGER | read-write | Resets the diagnostic error count. Not supported by MP7002 since no pattern generating tests are supported. |
| mp7002Performance | 1.3.6.1.4.1.498.6.6.5 | |||
| mp7002NearEndCurrent15MinTable | 1.3.6.1.4.1.498.6.6.5.1 | not-accessible | The mp7002 Current table. | |
| mp7002NearEndCurrent15MinEntry | 1.3.6.1.4.1.498.6.6.5.1.1 | not-accessible | An entry in the mp7002 NearEnd Current table. | |
| SCI mp7002NearEndCurrent15MinIndex | 1.3.6.1.4.1.498.6.6.5.1.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| OCT mp7002NearEndCurrent15MinStat | 1.3.6.1.4.1.498.6.6.5.1.1.2 | OCTET STRING | read-only | Returns a bitwise snapshot of the current 15Min statistics. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 Counter Overflow (>65535) LCV 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 LCV . 11.0 2^7 12.7 f/u 12.6 2^6 LCV . 12.0 2^0 |
| mp7002NearEndIntervalTable | 1.3.6.1.4.1.498.6.6.5.2 | not-accessible | The mp7002 Interval table. | |
| mp7002NearEndIntervalEntry | 1.3.6.1.4.1.498.6.6.5.2.1 | not-accessible | An entry in the E1 Interval table. | |
| SCI mp7002NearEndIntervalIndex | 1.3.6.1.4.1.498.6.6.5.2.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| INT mp7002NearEndIntervalNumber | 1.3.6.1.4.1.498.6.6.5.2.1.2 | INTEGER | read-only | The number of Errored Seconds encountered by an E1 interface in one of the previous 16, individual 15 minute, intervals. |
| OCT mp7002NearEndIntervalStat | 1.3.6.1.4.1.498.6.6.5.2.1.3 | OCTET STRING | read-only | Returns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 Counter Overflow (>65535) LCV 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 LCV . 11.0 2^7 12.7 f/u 12.6 2^6 LCV . 12.0 2^0 |
| mp7002NearEndCurrent24HrTable | 1.3.6.1.4.1.498.6.6.5.3 | not-accessible | The E1 Current24Hr table. 4 hour interval. | |
| mp7002NearEndCurrent24HrEntry | 1.3.6.1.4.1.498.6.6.5.3.1 | not-accessible | An entry in the E1 Total table. | |
| SCI mp7002NearEndCurrent24HrIndex | 1.3.6.1.4.1.498.6.6.5.3.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| OCT mp7002NearEndCurrent24HrStat | 1.3.6.1.4.1.498.6.6.5.3.1.2 | OCTET STRING | read-only | Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 13.7 f/u 13.6 f/u 13.5 f/u 13.4 f/u 13.3 f/u 13.2 1: Counter Overflow (>65535) LCV 13.1 2^15 13.0 2^14 14.7 f/u 14.6 2^13 LCV . 14.0 2^7 15.7 f/u 15.6 2^6 LCV . 15.0 2^0 |
| mp7002NearEndRecent24HrTable | 1.3.6.1.4.1.498.6.6.5.4 | not-accessible | The E1 Recent24Hr table. 4 hour interval. | |
| mp7002NearEndRecent24HrEntry | 1.3.6.1.4.1.498.6.6.5.4.1 | not-accessible | An entry in the E1 Total table. | |
| SCI mp7002NearEndRecent24HrIndex | 1.3.6.1.4.1.498.6.6.5.4.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| OCT mp7002NearEndRecent24HrStat | 1.3.6.1.4.1.498.6.6.5.4.1.2 | OCTET STRING | read-only | Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 13.7 f/u 13.6 f/u 13.5 f/u 13.4 f/u 13.3 f/u 13.2 1: Counter Overflow (>65535) LCV 13.1 2^15 13.0 2^14 14.7 f/u 14.6 2^13 LCV . 14.0 2^7 15.7 f/u 15.6 2^6 LCV . 15.0 2^0 |
| mp7002FarEndCurrent15MinTable | 1.3.6.1.4.1.498.6.6.5.5 | not-accessible | The mp7002FarEnd Current 15 minute table. | |
| mp7002FarEndCurrent15MinEntry | 1.3.6.1.4.1.498.6.6.5.5.1 | not-accessible | An entry in the mp7002FarEnd Current 15 Minute table. | |
| SCI mp7002FarEndCurrent15MinIndex | 1.3.6.1.4.1.498.6.6.5.5.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| OCT mp7002FarEndCurrent15MinStat | 1.3.6.1.4.1.498.6.6.5.5.1.2 | OCTET STRING | read-only | Returns a bitwise map of the far end interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 |
| mp7002FarEndIntervalTable | 1.3.6.1.4.1.498.6.6.5.6 | not-accessible | The mp7002FarEnd Interval table. | |
| mp7002FarEndIntervalEntry | 1.3.6.1.4.1.498.6.6.5.6.1 | not-accessible | An entry in the Interval table. | |
| SCI mp7002FarEndIntervalIndex | 1.3.6.1.4.1.498.6.6.5.6.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| INT mp7002FarEndIntervalNumber | 1.3.6.1.4.1.498.6.6.5.6.1.2 | INTEGER | read-only | A number between 1 and 16, where 1 is the most recently completed 15 minute interval and 16 is the least recently completed 15 minutes interval (assuming that all 16 intervals are valid). |
| OCT mp7002FarEndIntervalStat | 1.3.6.1.4.1.498.6.6.5.6.1.3 | OCTET STRING | read-only | Returns a bitwise map of statistics for the far end interface in the current 15 minute interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 |
| mp7002CurrentFarEnd24HrTable | 1.3.6.1.4.1.498.6.6.5.7 | not-accessible | The Current 24 Hour table. | |
| mp7002CurrentFarEnd24HrEntry | 1.3.6.1.4.1.498.6.6.5.7.1 | not-accessible | An entry in the Current 24 Hr table. | |
| SCI mp7002CurrentFarEnd24HrIndex | 1.3.6.1.4.1.498.6.6.5.7.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| OCT mp7002CurrentFarEnd24HrStat | 1.3.6.1.4.1.498.6.6.5.7.1.2 | OCTET STRING | read-only | Returns a bitwise map of statistics for the interface in the current 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 |
| mp7002RecentFarEnd24HrTable | 1.3.6.1.4.1.498.6.6.5.8 | not-accessible | The Recent 24 Hour table. | |
| mp7002RecentFarEnd24HrEntry | 1.3.6.1.4.1.498.6.6.5.8.1 | not-accessible | An entry in the Recent 24 Hr table. | |
| SCI mp7002RecentFarEnd24HrIndex | 1.3.6.1.4.1.498.6.6.5.8.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| OCT mp7002RecentFarEnd24HrStat | 1.3.6.1.4.1.498.6.6.5.8.1.2 | OCTET STRING | read-only | Returns a bitwise map of statistics for the interface in the Recent 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 |
| mp7002UnavailableTimeRegTable | 1.3.6.1.4.1.498.6.6.5.9 | not-accessible | The mp7002 Near End Unavailable Time Register table. | |
| mp7002UnavailableTimeRegEntry | 1.3.6.1.4.1.498.6.6.5.9.1 | not-accessible | An entry in the Unavailable Time Register table. | |
| SCI mp7002UnavailableTimeRegIndex | 1.3.6.1.4.1.498.6.6.5.9.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| INT mp7002UnavailableTimeRegNumber | 1.3.6.1.4.1.498.6.6.5.9.1.2 | INTEGER | read-only | A number between 1 and 6, where the number is the number of the Unavailable Time Register. |
| INT mp7002UnavailableTimeRegStart | 1.3.6.1.4.1.498.6.6.5.9.1.3 | INTEGER | read-only | Start time of one of the Unavailable Time Registers. |
| INT mp7002UnavailableTimeRegStop | 1.3.6.1.4.1.498.6.6.5.9.1.4 | INTEGER | read-only | Stop time of one of the Unavailable Time Registers. |
| mp7002FarEndUnavailableTimeRegTable | 1.3.6.1.4.1.498.6.6.5.10 | not-accessible | The mp7002 Unavailable Time Register table. | |
| mp7002FarEndUnavailableTimeRegEntry | 1.3.6.1.4.1.498.6.6.5.10.1 | not-accessible | An entry in the Unavailable Time Register table. | |
| SCI mp7002FarEndUnavailableTimeRegIndex | 1.3.6.1.4.1.498.6.6.5.10.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X. |
| INT mp7002FarEndUnavailableTimeRegNumber | 1.3.6.1.4.1.498.6.6.5.10.1.2 | INTEGER | read-only | A number between 1 and 6, where the number is the number of the Unavailable Time Register. |
| INT mp7002FarEndUnavailableTimeRegStart | 1.3.6.1.4.1.498.6.6.5.10.1.3 | INTEGER | read-only | Start time of one of the Unavailable Time Registers. |
| INT mp7002FarEndUnavailableTimeRegStop | 1.3.6.1.4.1.498.6.6.5.10.1.4 | INTEGER | read-only | Stop time of one of the Unavailable Time Registers. |
| mp7002SysConfig | 1.3.6.1.4.1.498.6.6.7 | |||
| mp7002SysTimingTable | 1.3.6.1.4.1.498.6.6.7.1 | not-accessible | The GDC System Timing table. These are unit options at the system level. | |
| mp7002SysTimingEntry | 1.3.6.1.4.1.498.6.6.7.1.1 | not-accessible | The GDC E1 Configuration table entry. | |
| SCI mp7002SysTimingIndex | 1.3.6.1.4.1.498.6.6.7.1.1.1 | SCinstance | read-only | Index value into the system configuration table. |
| INT mp7002SysTimingGen | 1.3.6.1.4.1.498.6.6.7.1.1.2 | INTEGER | read-write | Selects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(3) - unit is secondary Timig Generator for the shelf. Only 1 unit in the shelf can the primary or secondary timing generator. All other must be none. |
| mp7002HighwayAssignTable | 1.3.6.1.4.1.498.6.6.7.2 | not-accessible | The GDC System Configuration table. These are unit options at the system level. | |
| mp7002HighwayAssignEntry | 1.3.6.1.4.1.498.6.6.7.2.1 | not-accessible | The GDC E1 Highway Assign table entry. | |
| SCI mp7002HighwayAssignIndex | 1.3.6.1.4.1.498.6.6.7.2.1.1 | SCinstance | read-only | Index value into the Highway Assignment table. |
| INT mp7002TimeSlotBundle | 1.3.6.1.4.1.498.6.6.7.2.1.2 | INTEGER | read-only | Index for the bundle being assigned. A time slot bundle can be assigned to 1 or 2 of the 4 backplane highways. Bundle 1 is asigned in the Aggregate starting at Time Slot 1. Bundle 2 starts at the next available Time Slot. If only one bundle is needed, it must be bundle 1. The execute object should be sent only after acknowlegement of al assignment PDUs. |
| INT mp7002StartTimeSlot | 1.3.6.1.4.1.498.6.6.7.2.1.3 | INTEGER | read-write | Starting time slot of the bundle. If only 1 bundle is being assigned, or the first of 2 is being assigned, it must start at 1. The second of 2 must start at the next available time slot after the first bundle. |
| INT mp7002NumberOfTimeSlots | 1.3.6.1.4.1.498.6.6.7.2.1.4 | INTEGER | read-write | Number of time slots assigned to the bundle. |
| INT mp7002BundleDestination | 1.3.6.1.4.1.498.6.6.7.2.1.5 | INTEGER | read-write | Defines the destination of the bundle. |
| INT mp7002ExecuteAssign | 1.3.6.1.4.1.498.6.6.7.2.1.6 | INTEGER | read-write | Causes the MP7002 to execute configuration of the assigned highway configuration. This object should be sent in a separate PDU after acknowlegement of the assign PDU(s) has been recieved. |
| mp7002Alarms | 1.3.6.1.4.1.498.6.9 | |||
| mp7002AlarmData | 1.3.6.1.4.1.498.6.9.1 | |||
| mp7002NoResponseAlm | 1.3.6.1.4.1.498.6.9.1.1 | |||
| mp7002DiagRxErrAlm | 1.3.6.1.4.1.498.6.9.1.2 | |||
| mp7002PowerUpAlm | 1.3.6.1.4.1.498.6.9.1.3 | |||
| mp7002NvRamCorrupt | 1.3.6.1.4.1.498.6.9.1.4 | |||
| mp7002UnitFailure | 1.3.6.1.4.1.498.6.9.1.5 | |||
| mp7002TimingLoss | 1.3.6.1.4.1.498.6.9.1.6 | |||
| mp7002LCV | 1.3.6.1.4.1.498.6.9.1.7 | |||
| mp7002LossOfSignal | 1.3.6.1.4.1.498.6.9.1.8 | |||
| mp7002LossOfFrame | 1.3.6.1.4.1.498.6.9.1.9 | |||
| mp7002AlarmIndSignal | 1.3.6.1.4.1.498.6.9.1.10 | |||
| mp7002NEES | 1.3.6.1.4.1.498.6.9.1.11 | |||
| mp7002NEBBE | 1.3.6.1.4.1.498.6.9.1.12 | |||
| mp7002NESES | 1.3.6.1.4.1.498.6.9.1.13 | |||
| mp7002NEUAS | 1.3.6.1.4.1.498.6.9.1.14 | |||
| mp7002FEES | 1.3.6.1.4.1.498.6.9.1.15 | |||
| mp7002FEBBE | 1.3.6.1.4.1.498.6.9.1.16 | |||
| mp7002FESES | 1.3.6.1.4.1.498.6.9.1.17 | |||
| mp7002FEUAS | 1.3.6.1.4.1.498.6.9.1.18 | |||
| mp7002RAI | 1.3.6.1.4.1.498.6.9.1.19 | |||
| mp7002NearEndAlarmConfigTable | 1.3.6.1.4.1.498.6.9.2 | not-accessible | The mp7002NearEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table. | |
| mp7002NearEndAlarmConfigEntry | 1.3.6.1.4.1.498.6.9.2.1 | not-accessible | An entry in the MP7002 Alarm Configuration table. | |
| SCI mp7002NearEndAlarmConfigIndex | 1.3.6.1.4.1.498.6.9.2.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. |
| OID mp7002NearEndAlarmConfigIdentifier | 1.3.6.1.4.1.498.6.9.2.1.2 | OBJECT IDENTIFIER | read-only | The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm. |
| INT mp7002NearEndAlarmCountWindow | 1.3.6.1.4.1.498.6.9.2.1.3 | INTEGER | read-write | This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Default: disabled(1) |
| INT mp7002NearEndAlarmCountThreshold | 1.3.6.1.4.1.498.6.9.2.1.4 | INTEGER | read-write | This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Default: thresGT1(1) |
| mp7002FarEndAlarmConfigTable | 1.3.6.1.4.1.498.6.9.3 | not-accessible | The mp7002FarEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table. | |
| mp7002FarEndAlarmConfigEntry | 1.3.6.1.4.1.498.6.9.3.1 | not-accessible | An entry in the MP7002 Alarm Configuration table. | |
| SCI mp7002FarEndAlarmConfigIndex | 1.3.6.1.4.1.498.6.9.3.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. |
| OID mp7002FarEndAlarmConfigIdentifier | 1.3.6.1.4.1.498.6.9.3.1.2 | OBJECT IDENTIFIER | read-only | The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm. |
| INT mp7002FarEndAlarmCountWindow | 1.3.6.1.4.1.498.6.9.3.1.3 | INTEGER | read-write | This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Default: disabled(1) |
| INT mp7002FarEndAlarmCountThreshold | 1.3.6.1.4.1.498.6.9.3.1.4 | INTEGER | read-write | This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Default: thresGT1(1) |
| mp7002LocalAlarmConfigTable | 1.3.6.1.4.1.498.6.9.4 | not-accessible | The mp7002LocalAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table. | |
| mp7002LocalAlarmConfigEntry | 1.3.6.1.4.1.498.6.9.4.1 | not-accessible | An entry in the GDC Local Alarm Configuration table. | |
| SCI mp7002LocalAlarmConfigIndex | 1.3.6.1.4.1.498.6.9.4.1.1 | SCinstance | read-only | The index value which uniquely identifies the interface to which this entry is applicable. |
| INT mp7002UASNE | 1.3.6.1.4.1.498.6.9.4.1.2 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002SESNE | 1.3.6.1.4.1.498.6.9.4.1.3 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002BBENE | 1.3.6.1.4.1.498.6.9.4.1.4 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002ESNE | 1.3.6.1.4.1.498.6.9.4.1.5 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002UASFE | 1.3.6.1.4.1.498.6.9.4.1.6 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002SESFE | 1.3.6.1.4.1.498.6.9.4.1.7 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002BBEFE | 1.3.6.1.4.1.498.6.9.4.1.8 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002ESFE | 1.3.6.1.4.1.498.6.9.4.1.9 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002LOS | 1.3.6.1.4.1.498.6.9.4.1.10 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002LOF | 1.3.6.1.4.1.498.6.9.4.1.11 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002AIS | 1.3.6.1.4.1.498.6.9.4.1.12 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002TmgLoss | 1.3.6.1.4.1.498.6.9.4.1.13 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002LCVs | 1.3.6.1.4.1.498.6.9.4.1.14 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
| INT mp7002NtwkRAI | 1.3.6.1.4.1.498.6.9.4.1.15 | INTEGER | read-write | Disables or enables the alarm on the Major buss or Minor buss. |
RFC description
General DataComm MP7002 E1 interface diagnostics and performance monitoring.
Start monitoring General DataComm (GDC) MP7002 multiport WAN concentrator (E1) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.