GDCMP7002-MIB :: mp7002E1XCircuit

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GDCMP7002-MIB › mp7002E1XCircuit

mp7002E1XCircuit

Module: GDCMP7002-MIB

OID (symbolic): GDCMP7002-MIB::mp7002E1XCircuit

OID (numeric): 1.3.6.1.4.1.498.6.6.2.1.1.8

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: Circuit Name E1X is connected to

What is mp7002E1XCircuit?

Read-write string (16 chars) recording the name of the circuit the E1X cascade interface is connected to. Populate this the same way as mp7002E1Circuit, but for the secondary/cascade E1X port, when that interface is installed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.6.6.2.1.1.8
snmpwalk -v2c -c public <target> GDCMP7002-MIB::mp7002E1XCircuit

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.6.6.2.1.1.8.1
snmpget -v2c -c public <target> GDCMP7002-MIB::mp7002E1XCircuit.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.498.6.6.2.1.1.8.1 s <value>

Start monitoring General DataComm (GDC) MP7002 multiport WAN concentrator (E1) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCMP7002-MIB::mp7002E1XCircuit OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) MP7002 multiport WAN concentrator (E1) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcDMA200-MIB
1.3.6.1.4.1.498.6dsx1GDC-5553-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.6.6mp7002SystemGDCMP7002-MIB
1.3.6.1.4.1.498.6.6.2mp7002MaintenanceGDCMP7002-MIB
1.3.6.1.4.1.498.6.6.2.1mp7002MaintenanceTableGDCMP7002-MIB
1.3.6.1.4.1.498.6.6.2.1.1mp7002MaintenanceEntryGDCMP7002-MIB
1.3.6.1.4.1.498.6.6.2.1.1.8mp7002E1XCircuitGDCMP7002-MIB