GDCMP7002-MIB :: mp7002LCVs

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GDCMP7002-MIB › mp7002LCVs

mp7002LCVs

Module: GDCMP7002-MIB

OID (symbolic): GDCMP7002-MIB::mp7002LCVs

OID (numeric): 1.3.6.1.4.1.498.6.9.4.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Disables or enables the alarm on the Major buss or Minor buss.

What is mp7002LCVs?

Read-write enum (disabled/enabledMajor/enabledMinor) that enables or disables reporting of the Line Code Violation alarm onto the Major or Minor alarm bus. LCVs are a common early indicator of line degradation, so admins often route them to Minor while watching for escalation to more severe alarms.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.6.9.4.1.14
snmpwalk -v2c -c public <target> GDCMP7002-MIB::mp7002LCVs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.6.9.4.1.14.1
snmpget -v2c -c public <target> GDCMP7002-MIB::mp7002LCVs.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.498.6.9.4.1.14.1 i <value>

Start monitoring General DataComm (GDC) MP7002 multiport WAN concentrator (E1) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCMP7002-MIB::mp7002LCVs OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) MP7002 multiport WAN concentrator (E1) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcDMA200-MIB
1.3.6.1.4.1.498.6dsx1GDC-5553-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.6.9mp7002AlarmsGDCMP7002-MIB
1.3.6.1.4.1.498.6.9.4mp7002LocalAlarmConfigTableGDCMP7002-MIB
1.3.6.1.4.1.498.6.9.4.1mp7002LocalAlarmConfigEntryGDCMP7002-MIB
1.3.6.1.4.1.498.6.9.4.1.14mp7002LCVsGDCMP7002-MIB