-- Copyright 1994 General DataComm Inc., Inc. All Rights Reserved. -- -- Reproduction of this document is authorized on condition that the -- foregoing copyright notice is included. This General DataComm, GDC, -- SNMP Management Information Base Specification embodies GDCs' -- confidential and proprietary intellectual property. GDC retains all -- title and ownership in the Specification, including any revisions. -- -- It is GDCs intent to encourage the widespread use of this Specification -- in connection with the management of GDC's products. GDC grants vendors, -- end-users, and other interested parties a non-exclusive license to use -- this Specification in connection with the management of GDC's products. -- -- This Specification is supplied "AS IS," and GDC makes no warranty, -- either expressed or implied, as to the use operation, condition, or -- performance of the Specification. -- -- GDC MP7002 MIB -- -- Revision History -- Version Date Name Description -- 1.00A 20-Dec-95 D. Rosengrant Initial Revision -- -- 1.00B 31-Jan-96 D. Rosengrant Changes after Eng/SCM review -- -- 1.00C 13-Feb-96 D. Rosengrant Changes after final Eng/SCM review -- -- 1.00D 20-Feb-96 D. Rosengrant Alarm config table needed to be 2 tables -- Near End and Far End -- Added Alarm Status object to Maintenance Table -- -- 1.00E 02-Apr-96 D. Rosengrant add "notAssigned" to Interface type and DCC -- config bandwidth -- add system timing gen source status to -- Maintenance Table -- 1.00F 16-May-96 C. Amorossi Change enums for mp7002Framing -- 1.00G 10-Jul-96 D. Baylis Bump mp7002Alarms up one level (for mgt apps) -- 1.00H 16-Jul-96 W. Meltzer Move page feeds inside comments (it confuses some compilers) -- 1.00J 17-Jul-96 D. Baylis Moved mp7002SysConfig OID from 6 to 7 -- 1.00K 18-Jul-96 C. Amorossi Changed description of mp7002ResetStats, -- mp7002UnavailableTimeRegTable & mp7002SetRealTime -- Added mp7002FarEndUnavailableTimeRegTable, -- mp7002FarEndResetStats, mp7002NearEndStatLastInitialized, -- mp7002FarEndStatLastInitialized -- Made mp7002ResetTestResults read-write -- mp7002DiagTable is only Network Interface -- 1.00L 20-Aug-96 C. Amorossi Change mp7002Ais to mp7002AlarmIndSignal -- 1.00M 07-Nov-96 C. Amorossi Added comments to diagnostic table -- 1.00N 06-Jan-97 C. Amorossi Change description of mp7002SetRealTime -- Added alarm mp7002RAI -- 1.00P 13-Jan-97 C. Amorossi Added local alarm mp7002NtwkRAI -- GDCMP7002-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB SCinstance FROM GDCMACRO-MIB; gdc OBJECT IDENTIFIER ::= { enterprises 498 } dsx1 OBJECT IDENTIFIER ::= { gdc 6 } mp7002System OBJECT IDENTIFIER ::= { dsx1 6 } mp7002Alarms OBJECT IDENTIFIER ::= { dsx1 9 } mp7002Version OBJECT IDENTIFIER ::= { mp7002System 1 } mp7002Maintenance OBJECT IDENTIFIER ::= { mp7002System 2 } mp7002Configuration OBJECT IDENTIFIER ::= { mp7002System 3 } mp7002Diagnostics OBJECT IDENTIFIER ::= { mp7002System 4 } mp7002Performance OBJECT IDENTIFIER ::= { mp7002System 5 } mp7002SysConfig OBJECT IDENTIFIER ::= { mp7002System 7 } -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC 1212. -- The implementation of all groups is mandatory for all products that -- support a E1 interface. -- Note: All rows in all tables defined within this MIB module are -- virtual. They can neither be created or deleted by management -- operations. -- SCInstance: The interface part is defined as: -- 0 - Unit -- 1 - E1 interface -- 2 - E1X interface -- The Version Group. This group identifies the version information -- for the MIB. -- mp7002MIBversion OBJECT-TYPE SYNTAX DisplayString (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Acceptable values for the individual revision components are as follows: x: 1 - 9 y: 0 - 9 z: 0 - 9 T: A - Z Upon formal release, no designation for the test revision will be present." ::= { mp7002Version 1 } -- mp7002VersionTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002VersionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " " ::= { mp7002Version 2 } mp7002VersionEntry OBJECT-TYPE SYNTAX Mp7002VersionEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC Mp7002System Version Table." INDEX { mp7002VersionIndex } ::= { mp7002VersionTable 1 } Mp7002VersionEntry ::= SEQUENCE { mp7002VersionIndex SCinstance, mp7002FirmwareRev DisplayString, mp7002ModelNumber DisplayString, mp7002E1x INTEGER } mp7002VersionIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies Version parameters associated with the managed object." ::= { mp7002VersionEntry 1 } mp7002FirmwareRev OBJECT-TYPE SYNTAX DisplayString (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The version number of the firmware, to allow products to know which revision is installed. The released version number is sequenced from --, A-, ... AA, ... ZZ. Test versions are numerical from 01 to 99." ::= { mp7002VersionEntry 2 } mp7002ModelNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to determine the type of card family installed ex. MP7002." ::= { mp7002VersionEntry 3 } mp7002E1x OBJECT-TYPE SYNTAX INTEGER { installed(1), notPresent(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if the E1X Cascade Interface is installed." ::= {mp7002VersionEntry 4} -- The GDC E1 Group. This group contains objects that support the -- specific management requirements for products that support a GDC -- E1 interface. -- If the E1 interface also supports alarm reporting, then the -- GDC Alarm Management MIB should be deployed for managing the alarm -- reporting of the E1 Interface. -- -- ******************************************************************** -- GDC E1 Maintenance Table -- ******************************************************************** mp7002MaintenanceTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002MaintenanceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The table describes the maintenance objects for the unit and references the unit interface (cc = 00)." ::= { mp7002Maintenance 1 } mp7002MaintenanceEntry OBJECT-TYPE SYNTAX Mp7002MaintenanceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC E1 Maintenance Table." INDEX { mp7002MaintenanceLineIndex } ::= { mp7002MaintenanceTable 1 } Mp7002MaintenanceEntry ::= SEQUENCE { mp7002MaintenanceLineIndex SCinstance, mp7002SoftReset INTEGER, mp7002SysUpTime INTEGER, mp7002DefaultInit INTEGER, mp7002ResetStats INTEGER, mp7002LedStatus OCTET STRING, mp7002E1Circuit DisplayString, mp7002E1XCircuit DisplayString, mp7002TSBundle1Name DisplayString, mp7002TSBundle2Name DisplayString, mp7002SetRealTime INTEGER, mp7002AlarmStatus OCTET STRING, mp7002SystemTimingGenStatus INTEGER, mp7002FarEndResetStats INTEGER, mp7002NearEndStatLastInitialized INTEGER, mp7002FarEndStatLastInitialized INTEGER } mp7002MaintenanceLineIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies Maintenance parameters associated with the managed object." ::= { mp7002MaintenanceEntry 1 } mp7002SoftReset OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose meaning is specific to the type of unit being managed. The value of norm(1) will be returned when the reset is complete. The value of norm(1) can not be set by management." ::= { mp7002MaintenanceEntry 2 } mp7002SysUpTime OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count." ::= { mp7002MaintenanceEntry 3 } mp7002DefaultInit OBJECT-TYPE SYNTAX INTEGER { normal(1), factoryDefault(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(1) the unit will perform a reset to make the default configuration take affect. The value of normal(2) will be returned when the initialization is complete. The value of normal(2) can not be set by management." ::= { mp7002MaintenanceEntry 4 } mp7002ResetStats OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the mp7002NearEndValidIntervals object. When this object is set to reset(2), then the unit will reset the mp7002NearEndValidIntervals object to zero. The value of norm(1) can not be set by management." ::= { mp7002MaintenanceEntry 5 } mp7002LedStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit 2 - NIU bit 1 - D_I bit 0 - future use Octet 2 bit 7 - not used bit 6 - future use bit 5 - NTWK AIS bit 4 - NTWK LCV bit 3 - NTWK LOS bit 2 - NTWK OOF bit 1 - ALM bit 0 - TM Octet 3 bit 7 - not used bit 6 - ST- future use bit 5 - LT- future use bit 4 - RL- future use bit 3 - future use bit 2 - future use bit 1 - future use bit 0 - future use" ::= { mp7002MaintenanceEntry 6 } mp7002E1Circuit OBJECT-TYPE SYNTAX DisplayString (SIZE(16)) ACCESS read-write STATUS mandatory DESCRIPTION "Circuit name E1 is connected to." ::= { mp7002MaintenanceEntry 7 } mp7002E1XCircuit OBJECT-TYPE SYNTAX DisplayString (SIZE(16)) ACCESS read-write STATUS mandatory DESCRIPTION "Circuit Name E1X is connected to" ::= { mp7002MaintenanceEntry 8 } mp7002TSBundle1Name OBJECT-TYPE SYNTAX DisplayString (SIZE(16)) ACCESS read-write STATUS mandatory DESCRIPTION "Name first Time Slot Bundle is assigned to. Only used when unit is configured for drop side interface" ::= { mp7002MaintenanceEntry 9 } mp7002TSBundle2Name OBJECT-TYPE SYNTAX DisplayString (SIZE(16)) ACCESS read-write STATUS mandatory DESCRIPTION "Name second Time Slot Bundle is assigned to. Only used when unit is configured for drop side interface." ::= { mp7002MaintenanceEntry 10 } mp7002SetRealTime OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "Number of seconds from midnight Dec 31, 1969." ::= {mp7002MaintenanceEntry 11} mp7002AlarmStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NWTK_LOS bit 5 - NWTK_LOF bit 4 - NWTK_AIS bit 3 - NTWK_LCV bit 2 - TIMING LOSS bit 1 - NTWK_NE_ES bit 0 - NTWK_NE_BBE Octet 2 bit 7 - not used bit 6 - NTWK_NE_SES bit 5 - NTWK_NE_UAS bit 4 - NTWK_FE_ES bit 3 - NTWK_FE_BBE bit 2 - NTWK_FE_SES bit 1 - NTWK_FE_UAS bit 0 - NTWK_RAI Octet 3 bit 7 - not used bit 6 - E1X_LOS bit 5 - E1X_LOF bit 4 - E1X_AIS bit 3 - E1X_NE_ES bit 2 - E1X_NE_BBE bit 1 - E1X_NE_SES bit 0 - E1X_NE_UAS Octet 4 bit 7 - not used bit 6 - E1X_FE_ES bit 5 - E1X_FE_BBE bit 4 - E1X_FE_SES bit 3 - E1X_FE_UAS bit 2 - NVRAM corrupted bit 1 - unit failure bit 0 - Power-up Alarm" ::= {mp7002MaintenanceEntry 12} mp7002SystemTimingGenStatus OBJECT-TYPE SYNTAX INTEGER { none(1), clk8khz(2), clk4mhz(3), clk8khzand4mhz(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both." ::= {mp7002MaintenanceEntry 13} mp7002FarEndResetStats OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the mp7002FarEndValidIntervals object. When this object is set to reset(2), then the unit will reset the mp7002FarEndValidIntervals object to zero. The value of norm(1) can not be set by management." ::= { mp7002MaintenanceEntry 14 } mp7002NearEndStatLastInitialized OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds from midnight Dec 31, 1969 up until mp7002NearEndValidIntervals was last initialized to zero" ::= {mp7002MaintenanceEntry 15} mp7002FarEndStatLastInitialized OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Number of seconds from midnight Dec 31, 1969 up until mp7002FarEndValidIntervals was last initialized to zero" ::= {mp7002MaintenanceEntry 16} -- -- ******************************************************************** -- The GDC E1 Configuration Table -- ******************************************************************** mp7002ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC E1 Configuration table." ::= { mp7002Configuration 1 } mp7002ConfigEntry OBJECT-TYPE SYNTAX Mp7002ConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC E1 Configuration table entry." INDEX { mp7002ConfigIndex } ::= { mp7002ConfigTable 1 } Mp7002ConfigEntry ::= SEQUENCE { mp7002ConfigIndex SCinstance, mp7002InterfaceType INTEGER, mp7002RcvrRange INTEGER, mp7002TransmitClockSource INTEGER, mp7002FallbackClockSource INTEGER, mp7002FacilityDataLink INTEGER, mp7002NearEndValidIntervals INTEGER, mp7002FarEndValidIntervals INTEGER, mp7002NetworkConnection INTEGER, mp7002Framing INTEGER, mp7002LineCoding INTEGER } mp7002ConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002ConfigEntry 1 } mp7002InterfaceType OBJECT-TYPE SYNTAX INTEGER { diu(1), niu(2), notAssigned(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The operating mode of the interface to be either Network Side, Drop Side or not assigned." ::= { mp7002ConfigEntry 2 } mp7002RcvrRange OBJECT-TYPE SYNTAX INTEGER { short(1), long(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the receiver range to short (6dB) or long (36dB)" ::= { mp7002ConfigEntry 3 } mp7002TransmitClockSource OBJECT-TYPE SYNTAX INTEGER { system(1), recovered(2), internal(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the transmit clock source." ::= { mp7002ConfigEntry 4 } mp7002FallbackClockSource OBJECT-TYPE SYNTAX INTEGER { system(1), recovered(2), internal(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Identifies the fallback transmit clock source." ::= { mp7002ConfigEntry 5 } mp7002FacilityDataLink OBJECT-TYPE SYNTAX INTEGER { none(1), active(2), notActive(3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mp7002ConfigEntry 6 } mp7002NearEndValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..16) ACCESS read-only STATUS mandatory DESCRIPTION "The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. This object is only valid for the E1 interface." ::= { mp7002ConfigEntry 7 } mp7002FarEndValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..16) ACCESS read-only STATUS mandatory DESCRIPTION "The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought on-line within the last 4 hours, in which case the value will be the number of complete 15 minute intervals the since interface has been online. This object is only valid for the E1 interface." ::= { mp7002ConfigEntry 8 } mp7002NetworkConnection OBJECT-TYPE SYNTAX INTEGER { onLine(1), standBy(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets whether the network interface is standby or online. This only applies to the Network Interface." ::= {mp7002ConfigEntry 9} mp7002Framing OBJECT-TYPE SYNTAX INTEGER { cCSwithoutCRC4(1), pCS0withoutCRC4(2), pCS1withoutCRC4(3), cCSwithCRC4(4), pCS0withCRC4(5), pCS1withCRC4(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Set the framing for the interface. Abbreviations are as follows: CCS - common-channel signaling PCS0 - per channel signaling phase 0 PCS1 - per channel signaling phase 1" ::= {mp7002ConfigEntry 10} mp7002LineCoding OBJECT-TYPE SYNTAX INTEGER { ami(1), hdb3(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Sets the line coding for the interface." ::= {mp7002ConfigEntry 11} -- -- ******************************************************************** -- The GDC E1 System Configuration Table -- ******************************************************************** mp7002SysTimingTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002SysTimingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC System Timing table. These are unit options at the system level." ::= { mp7002SysConfig 1 } mp7002SysTimingEntry OBJECT-TYPE SYNTAX Mp7002SysTimingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC E1 Configuration table entry." INDEX { mp7002SysTimingIndex } ::= { mp7002SysTimingTable 1 } Mp7002SysTimingEntry ::= SEQUENCE { mp7002SysTimingIndex SCinstance, mp7002SysTimingGen INTEGER } mp7002SysTimingIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Index value into the system configuration table." ::= { mp7002SysTimingEntry 1 } mp7002SysTimingGen OBJECT-TYPE SYNTAX INTEGER { none(1), primary(2), secondary(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(3) - unit is secondary Timig Generator for the shelf. Only 1 unit in the shelf can the primary or secondary timing generator. All other must be none." ::= {mp7002SysTimingEntry 2} -- -- ********************************************************************* -- The GDC DCC Configuration Table -- ********************************************************************* mp7002DCCConfigurationTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002DCCConfigurationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC DCC Configuration table. These are Diagnostic Channel configuration options." ::= { mp7002Configuration 2} mp7002DCCConfigurationEntry OBJECT-TYPE SYNTAX Mp7002DCCConfigurationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC Diagnostic Configuration table entry." INDEX { mp7002DCCConfigurationIndex } ::= { mp7002DCCConfigurationTable 1 } Mp7002DCCConfigurationEntry ::= SEQUENCE { mp7002DCCConfigurationIndex SCinstance, mp7002TimeSlot INTEGER, mp7002Bandwidth INTEGER } mp7002DCCConfigurationIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Index value into the DCC Configuration table." ::= { mp7002DCCConfigurationEntry 1 } mp7002TimeSlot OBJECT-TYPE SYNTAX INTEGER(1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Time Slot DCC goes in" ::={ mp7002DCCConfigurationEntry 2} mp7002Bandwidth OBJECT-TYPE SYNTAX INTEGER { kbps8(1), kbps56(2), kbps64(3), notAssigned(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Bandwidth to use: 8 kbps - bit 7 only 56 kbps - bits 0 - 6 64 kbps - all 8 bits" ::={ mp7002DCCConfigurationEntry 3} -- ******************************************************************** -- The GDC E1 Highway Assignment Table -- ******************************************************************** mp7002HighwayAssignTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002HighwayAssignEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC System Configuration table. These are unit options at the system level." ::= { mp7002SysConfig 2} mp7002HighwayAssignEntry OBJECT-TYPE SYNTAX Mp7002HighwayAssignEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC E1 Highway Assign table entry." INDEX { mp7002HighwayAssignIndex, mp7002TimeSlotBundle } ::= { mp7002HighwayAssignTable 1 } Mp7002HighwayAssignEntry ::= SEQUENCE { mp7002HighwayAssignIndex SCinstance, mp7002TimeSlotBundle INTEGER, mp7002StartTimeSlot INTEGER, mp7002NumberOfTimeSlots INTEGER, mp7002BundleDestination INTEGER, mp7002ExecuteAssign INTEGER } mp7002HighwayAssignIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Index value into the Highway Assignment table." ::= { mp7002HighwayAssignEntry 1 } mp7002TimeSlotBundle OBJECT-TYPE SYNTAX INTEGER { bundle1(1), bundle2(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Index for the bundle being assigned. A time slot bundle can be assigned to 1 or 2 of the 4 backplane highways. Bundle 1 is asigned in the Aggregate starting at Time Slot 1. Bundle 2 starts at the next available Time Slot. If only one bundle is needed, it must be bundle 1. The execute object should be sent only after acknowlegement of al assignment PDUs." ::= {mp7002HighwayAssignEntry 2 } mp7002StartTimeSlot OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Starting time slot of the bundle. If only 1 bundle is being assigned, or the first of 2 is being assigned, it must start at 1. The second of 2 must start at the next available time slot after the first bundle." ::= {mp7002HighwayAssignEntry 3 } mp7002NumberOfTimeSlots OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Number of time slots assigned to the bundle." ::= {mp7002HighwayAssignEntry 4 } mp7002BundleDestination OBJECT-TYPE SYNTAX INTEGER { notAssigned(1), highway1(2), highway2(3), highway3(4), highway4(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the destination of the bundle." ::= {mp7002HighwayAssignEntry 5 } mp7002ExecuteAssign OBJECT-TYPE SYNTAX INTEGER { normal(1), execute(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Causes the MP7002 to execute configuration of the assigned highway configuration. This object should be sent in a separate PDU after acknowlegement of the assign PDU(s) has been recieved." ::= {mp7002HighwayAssignEntry 6 } -- ******************************************************************** -- GDC E1 Diagnostics -- ******************************************************************** mp7002DiagTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002DiagEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC E1 Diagnostics table. Information in the entries of this table support diagnostics testing via loopbacks. Diagnostics are only supported when mp7002InterfaceType is set to niu(2). This table applies to the Network Interface only." ::= { mp7002Diagnostics 1 } mp7002DiagEntry OBJECT-TYPE SYNTAX Mp7002DiagEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The GDC E1 Diagnostics table entry." INDEX { mp7002DiagIndex } ::= { mp7002DiagTable 1 } Mp7002DiagEntry ::= SEQUENCE { mp7002DiagIndex SCinstance, mp7002TestPattern INTEGER, mp7002DiagConfig INTEGER, mp7002TestLimit INTEGER, mp7002TestExecutionStatus INTEGER, mp7002TestExceptions INTEGER, mp7002TestResults INTEGER, mp7002ResetTestResults INTEGER } mp7002DiagIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002DiagEntry 1 } mp7002TestPattern OBJECT-TYPE SYNTAX INTEGER { noCode(1), pat511(2), pat2047(3), pat1in4(4) } ACCESS read-write STATUS obsolete DESCRIPTION "Test pattern for tests that use the pattern generator. The value of this object is used when mp7002DiagConfig.unitTest(5) or mp7002DiagConfig.patGenOn(6) is selected. NOT SUPPORTED BY THE MP7002." ::= { mp7002DiagEntry 2 } mp7002DiagConfig OBJECT-TYPE SYNTAX INTEGER { noLoop(1), lineLoopback(2), payloadLoopback(3), localTest(4), -- not supported by the mp7002 unitTest(5), -- not supported by the mp7002 patGenOn(6) -- not supported by the mp7002 } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the test to run. noLoop(1) ends the test. Interoperates with mp7002TestPattern. When unitTest(2) or patGenOn(3) is selected, the pattern in mp7002TestPattern is used. payloadLoopback(4) and lineLoopback(5) are only valid when the unit is configured for a Network Side interface. localTest(6) is only valid when the unit is configured for a Drop Side interface." ::= { mp7002DiagEntry 3 } mp7002TestLimit OBJECT-TYPE SYNTAX INTEGER { testTime10Mins(1), testTime20Mins(2), noLimit(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Selects the duration to run a diagnostic test. The value(1) noLimit signifies that the test should run indefinitely until explicitly terminated. Default value: testTime10Mins(1)" ::= { mp7002DiagEntry 4 } mp7002TestExecutionStatus OBJECT-TYPE SYNTAX INTEGER { notInTest(1), -- a test is not running testInProgress(2), -- the test is running testCompleted(4), -- the test is complete testCompletedNotInTest(5) -- a test has completed,nolonger in test } ACCESS read-only STATUS mandatory DESCRIPTION "This variable reports the status of a test. notInTest(1) indicates a test is not running. testInProgress(2) indicates that a test is currently running. testCompleted(4) indicates that a test has run and is completed. testCompletedNotInTest(5) indicates that a test has completed and it is no longer in test." ::= { mp7002DiagEntry 5 } mp7002TestExceptions OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take the value zero. Then, for each exception, the value associated with the exception is added to the sum. The exception values are: value exception 1 a timed test was preempted so the result cannot be viewed in relation to the test duration 2 the results overflowed so the result cannot be viewed as an absolute value 4 the test was performed while synchronization could not be performed so the result may not be accurate." ::= { mp7002DiagEntry 6 } mp7002TestResults OBJECT-TYPE SYNTAX INTEGER(0..1048576) ACCESS read-only STATUS obsolete DESCRIPTION "The results of the last diagnostic test. This can be the current test running or the last completed test. Note that the interpretation of these results may be affected by the value of the mp7002TestExceptions object. Not supported by MP7002 since no pattern generating tests are supported." ::= { mp7002DiagEntry 7 } mp7002ResetTestResults OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS obsolete DESCRIPTION "Resets the diagnostic error count. Not supported by MP7002 since no pattern generating tests are supported." ::= { mp7002DiagEntry 8 } -- -- ******************************************************************** -- Current 15 Near End Minute Performance Table -- ******************************************************************** mp7002NearEndCurrent15MinTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002NearEndCurrent15MinEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The mp7002 Current table." ::= { mp7002Performance 1 } mp7002NearEndCurrent15MinEntry OBJECT-TYPE SYNTAX Mp7002NearEndCurrent15MinEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mp7002 NearEnd Current table." INDEX { mp7002NearEndCurrent15MinIndex } ::= { mp7002NearEndCurrent15MinTable 1 } Mp7002NearEndCurrent15MinEntry ::= SEQUENCE { mp7002NearEndCurrent15MinIndex SCinstance, mp7002NearEndCurrent15MinStat OCTET STRING } mp7002NearEndCurrent15MinIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002NearEndCurrent15MinEntry 1 } -- mp7002NearEndCurrent15MinStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise snapshot of the current 15Min statistics. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 Counter Overflow (>65535) LCV 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 LCV . 11.0 2^7 12.7 f/u 12.6 2^6 LCV . 12.0 2^0 " ::= {mp7002NearEndCurrent15MinEntry 2 } -- -- ******************************************************************** -- Interval Near End Performance Table -- ******************************************************************** mp7002NearEndIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002NearEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The mp7002 Interval table." ::= { mp7002Performance 2 } mp7002NearEndIntervalEntry OBJECT-TYPE SYNTAX Mp7002NearEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the E1 Interval table." INDEX { mp7002NearEndIntervalIndex, mp7002NearEndIntervalNumber } ::= { mp7002NearEndIntervalTable 1 } Mp7002NearEndIntervalEntry ::= SEQUENCE { mp7002NearEndIntervalIndex SCinstance, mp7002NearEndIntervalNumber INTEGER, mp7002NearEndIntervalStat OCTET STRING } mp7002NearEndIntervalIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002NearEndIntervalEntry 1 } mp7002NearEndIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "The number of Errored Seconds encountered by an E1 interface in one of the previous 16, individual 15 minute, intervals." ::= {mp7002NearEndIntervalEntry 2 } -- mp7002NearEndIntervalStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise map of the interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 Counter Overflow (>65535) LCV 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 LCV . 11.0 2^7 12.7 f/u 12.6 2^6 LCV . 12.0 2^0 " ::= {mp7002NearEndIntervalEntry 3 } -- ******************************************************************** -- Current 24 Hour Near End Performance Table -- ******************************************************************** mp7002NearEndCurrent24HrTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002NearEndCurrent24HrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The E1 Current24Hr table. 4 hour interval." ::= { mp7002Performance 3} -- mp7002NearEndCurrent24HrEntry OBJECT-TYPE SYNTAX Mp7002NearEndCurrent24HrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the E1 Total table." INDEX { mp7002NearEndCurrent24HrIndex } ::= { mp7002NearEndCurrent24HrTable 1 } Mp7002NearEndCurrent24HrEntry ::= SEQUENCE { mp7002NearEndCurrent24HrIndex SCinstance, mp7002NearEndCurrent24HrStat OCTET STRING } mp7002NearEndCurrent24HrIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002NearEndCurrent24HrEntry 1 } -- mp7002NearEndCurrent24HrStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (15)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 13.7 f/u 13.6 f/u 13.5 f/u 13.4 f/u 13.3 f/u 13.2 1: Counter Overflow (>65535) LCV 13.1 2^15 13.0 2^14 14.7 f/u 14.6 2^13 LCV . 14.0 2^7 15.7 f/u 15.6 2^6 LCV . 15.0 2^0 " ::= {mp7002NearEndCurrent24HrEntry 2 } -- -- ******************************************************************** -- Recent 24 Hour Near End Performance Table -- ******************************************************************** mp7002NearEndRecent24HrTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002NearEndRecent24HrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The E1 Recent24Hr table. 4 hour interval." ::= { mp7002Performance 4} mp7002NearEndRecent24HrEntry OBJECT-TYPE SYNTAX Mp7002NearEndRecent24HrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the E1 Total table." INDEX { mp7002NearEndRecent24HrIndex } ::= { mp7002NearEndRecent24HrTable 1 } Mp7002NearEndRecent24HrEntry ::= SEQUENCE { mp7002NearEndRecent24HrIndex SCinstance, mp7002NearEndRecent24HrStat OCTET STRING } mp7002NearEndRecent24HrIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002NearEndRecent24HrEntry 1 } -- mp7002NearEndRecent24HrStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE (15)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise map of the current 24 hour table 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 13.7 f/u 13.6 f/u 13.5 f/u 13.4 f/u 13.3 f/u 13.2 1: Counter Overflow (>65535) LCV 13.1 2^15 13.0 2^14 14.7 f/u 14.6 2^13 LCV . 14.0 2^7 15.7 f/u 15.6 2^6 LCV . 15.0 2^0 " ::= {mp7002NearEndRecent24HrEntry 2 } -- -- ******************************************************************** -- Far End Current 15 Minute Performance Table -- ******************************************************************** mp7002FarEndCurrent15MinTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002FarEndCurrent15MinEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The mp7002FarEnd Current 15 minute table." ::= { mp7002Performance 5 } mp7002FarEndCurrent15MinEntry OBJECT-TYPE SYNTAX Mp7002FarEndCurrent15MinEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mp7002FarEnd Current 15 Minute table." INDEX { mp7002FarEndCurrent15MinIndex } ::= { mp7002FarEndCurrent15MinTable 1 } Mp7002FarEndCurrent15MinEntry ::= SEQUENCE { mp7002FarEndCurrent15MinIndex SCinstance, mp7002FarEndCurrent15MinStat OCTET STRING } mp7002FarEndCurrent15MinIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002FarEndCurrent15MinEntry 1 } -- mp7002FarEndCurrent15MinStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE(9)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise map of the far end interface in one of the previous 16, individual 15 minute, intervals. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 " ::= {mp7002FarEndCurrent15MinEntry 2 } -- -- ******************************************************************** -- Interval Far End Performance Table -- ******************************************************************** mp7002FarEndIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002FarEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The mp7002FarEnd Interval table." ::= { mp7002Performance 6 } mp7002FarEndIntervalEntry OBJECT-TYPE SYNTAX Mp7002FarEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Interval table." INDEX { mp7002FarEndIntervalIndex, mp7002FarEndIntervalNumber } ::= { mp7002FarEndIntervalTable 1 } Mp7002FarEndIntervalEntry ::= SEQUENCE { mp7002FarEndIntervalIndex SCinstance, mp7002FarEndIntervalNumber INTEGER, mp7002FarEndIntervalStat OCTET STRING } mp7002FarEndIntervalIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002FarEndIntervalEntry 1 } mp7002FarEndIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "A number between 1 and 16, where 1 is the most recently completed 15 minute interval and 16 is the least recently completed 15 minutes interval (assuming that all 16 intervals are valid)." ::= { mp7002FarEndIntervalEntry 2 } mp7002FarEndIntervalStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE(9)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise map of statistics for the far end interface in the current 15 minute interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 2^9 ES . 1.0 2^7 2.7 f/u 2.6 2^6 . 2.0 2^0 3.7 f/u 3.6 f/u 3.5 f/u 3.4 f/u 3.3 f/u 3.2 2^9 SES . 3.0 2^7 4.7 f/u 4.6 2^6 SES . 4.0 2^0 5.7 f/u 5.6 f/u 5.5 f/u 5.4 f/u 5.3 f/u 5.2 Counter Overflow (>65535) BBE 5.1 2^15 5.0 2^14 6.7 f/u 6.6 2^13 BBE . 6.0 2^7 7.7 f/u 7.6 2^6 BBE . 7.0 2^0 8.7 f/u 8.6 f/u 8.5 f/u 8.4 f/u 8.3 f/u 8.2 2^9 UAS . 8.0 2^7 9.7 f/u 9.6 2^6 UAS . 9.0 2^0 " ::= {mp7002FarEndIntervalEntry 3 } -- -- ******************************************************************** -- Current 24 Hour Far End Performance Table -- ******************************************************************** mp7002CurrentFarEnd24HrTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002CurrentFarEnd24HrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Current 24 Hour table." ::= { mp7002Performance 7 } mp7002CurrentFarEnd24HrEntry OBJECT-TYPE SYNTAX Mp7002CurrentFarEnd24HrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Current 24 Hr table." INDEX { mp7002CurrentFarEnd24HrIndex } ::= { mp7002CurrentFarEnd24HrTable 1 } Mp7002CurrentFarEnd24HrEntry ::= SEQUENCE { mp7002CurrentFarEnd24HrIndex SCinstance, mp7002CurrentFarEnd24HrStat OCTET STRING } -- mp7002CurrentFarEnd24HrIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002CurrentFarEnd24HrEntry 1 } mp7002CurrentFarEnd24HrStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise map of statistics for the interface in the current 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 " ::= {mp7002CurrentFarEnd24HrEntry 2 } -- -- ******************************************************************** -- Recent 24 Hour Far End Performance Table -- ******************************************************************** mp7002RecentFarEnd24HrTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002RecentFarEnd24HrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Recent 24 Hour table." ::= { mp7002Performance 8 } mp7002RecentFarEnd24HrEntry OBJECT-TYPE SYNTAX Mp7002RecentFarEnd24HrEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Recent 24 Hr table." INDEX { mp7002RecentFarEnd24HrIndex } ::= { mp7002RecentFarEnd24HrTable 1 } Mp7002RecentFarEnd24HrEntry ::= SEQUENCE { mp7002RecentFarEnd24HrIndex SCinstance, mp7002RecentFarEnd24HrStat OCTET STRING } mp7002RecentFarEnd24HrIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002RecentFarEnd24HrEntry 1 } mp7002RecentFarEnd24HrStat OBJECT-TYPE SYNTAX OCTET STRING (SIZE(12)) ACCESS read-only STATUS mandatory DESCRIPTION "Returns a bitwise map of statistics for the interface in the Recent 24 hour interval. 1.7 f/u 1.6 f/u 1.5 f/u 1.4 f/u 1.3 f/u 1.2 1: Counter Overflow (>65535) ES 1.1 2^15 1.0 2^14 2.7 f/u 2.6 2^13 ES . 2.0 2^7 3.7 f/u 3.6 2^6 ES . 3.0 2^0 4.7 f/u 4.6 f/u 4.5 f/u 4.4 f/u 4.3 f/u 4.2 1: Counter Overflow (>65535) SES 4.1 2^15 4.0 2^14 5.7 f/u 5.6 2^13 SES . 5.0 2^7 6.7 f/u 6.6 2^6 SES . 6.0 2^0 7.7 f/u 7.6 f/u 7.5 f/u 7.4 f/u 7.3 f/u 7.2 1: Counter Overflow (>65535) BBE 7.1 2^15 7.0 2^14 8.7 f/u 8.6 2^13 BBE . 8.0 2^7 9.7 f/u 9.6 2^6 BBE . 9.0 2^0 10.7 f/u 10.6 f/u 10.5 f/u 10.4 f/u 10.3 f/u 10.2 1: Counter Overflow (>65535) UAS 10.1 2^15 10.0 2^14 11.7 f/u 11.6 2^13 UAS . 11.0 2^7 12.7 f/u 12.6 2^6 UAS . 12.0 2^0 " ::= {mp7002RecentFarEnd24HrEntry 2 } -- -- ******************************************************************** -- Near End Unavailable Time Registers -- ******************************************************************** mp7002UnavailableTimeRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002UnavailableTimeRegEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The mp7002 Near End Unavailable Time Register table." ::= { mp7002Performance 9 } mp7002UnavailableTimeRegEntry OBJECT-TYPE SYNTAX Mp7002UnavailableTimeRegEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Unavailable Time Register table." INDEX { mp7002UnavailableTimeRegIndex, mp7002UnavailableTimeRegNumber } ::= { mp7002UnavailableTimeRegTable 1 } Mp7002UnavailableTimeRegEntry ::= SEQUENCE { mp7002UnavailableTimeRegIndex SCinstance, mp7002UnavailableTimeRegNumber INTEGER, mp7002UnavailableTimeRegStart INTEGER, mp7002UnavailableTimeRegStop INTEGER } mp7002UnavailableTimeRegIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002UnavailableTimeRegEntry 1 } mp7002UnavailableTimeRegNumber OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "A number between 1 and 6, where the number is the number of the Unavailable Time Register." ::= { mp7002UnavailableTimeRegEntry 2 } mp7002UnavailableTimeRegStart OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Start time of one of the Unavailable Time Registers." ::= {mp7002UnavailableTimeRegEntry 3} mp7002UnavailableTimeRegStop OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Stop time of one of the Unavailable Time Registers." ::= {mp7002UnavailableTimeRegEntry 4} -- -- ******************************************************************** -- Far End Unavailable Time Registers -- ******************************************************************** mp7002FarEndUnavailableTimeRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002FarEndUnavailableTimeRegEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The mp7002 Unavailable Time Register table." ::= { mp7002Performance 10 } mp7002FarEndUnavailableTimeRegEntry OBJECT-TYPE SYNTAX Mp7002FarEndUnavailableTimeRegEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the Unavailable Time Register table." INDEX { mp7002FarEndUnavailableTimeRegIndex, mp7002FarEndUnavailableTimeRegNumber } ::= { mp7002FarEndUnavailableTimeRegTable 1 } Mp7002FarEndUnavailableTimeRegEntry ::= SEQUENCE { mp7002FarEndUnavailableTimeRegIndex SCinstance, mp7002FarEndUnavailableTimeRegNumber INTEGER, mp7002FarEndUnavailableTimeRegStart INTEGER, mp7002FarEndUnavailableTimeRegStop INTEGER } mp7002FarEndUnavailableTimeRegIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop, and interface. Interface can be Network or, when supported, E1X." ::= { mp7002FarEndUnavailableTimeRegEntry 1 } mp7002FarEndUnavailableTimeRegNumber OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "A number between 1 and 6, where the number is the number of the Unavailable Time Register." ::= { mp7002FarEndUnavailableTimeRegEntry 2 } mp7002FarEndUnavailableTimeRegStart OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Start time of one of the Unavailable Time Registers." ::= {mp7002FarEndUnavailableTimeRegEntry 3} mp7002FarEndUnavailableTimeRegStop OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Stop time of one of the Unavailable Time Registers." ::= {mp7002FarEndUnavailableTimeRegEntry 4} -- -- ******************************************************************** -- GDC Dsx-1 Alarm Object Identifier Definitions -- ******************************************************************** mp7002AlarmData OBJECT IDENTIFIER ::= { mp7002Alarms 1 } mp7002NoResponseAlm OBJECT IDENTIFIER ::= { mp7002AlarmData 1 } mp7002DiagRxErrAlm OBJECT IDENTIFIER ::= { mp7002AlarmData 2 } mp7002PowerUpAlm OBJECT IDENTIFIER ::= { mp7002AlarmData 3 } mp7002NvRamCorrupt OBJECT IDENTIFIER ::= { mp7002AlarmData 4 } mp7002UnitFailure OBJECT IDENTIFIER ::= { mp7002AlarmData 5 } mp7002TimingLoss OBJECT IDENTIFIER ::= { mp7002AlarmData 6 } mp7002LCV OBJECT IDENTIFIER ::= { mp7002AlarmData 7 } mp7002LossOfSignal OBJECT IDENTIFIER ::= { mp7002AlarmData 8 } mp7002LossOfFrame OBJECT IDENTIFIER ::= { mp7002AlarmData 9 } mp7002AlarmIndSignal OBJECT IDENTIFIER ::= { mp7002AlarmData 10 } mp7002NEES OBJECT IDENTIFIER ::= { mp7002AlarmData 11 } mp7002NEBBE OBJECT IDENTIFIER ::= { mp7002AlarmData 12 } mp7002NESES OBJECT IDENTIFIER ::= { mp7002AlarmData 13 } mp7002NEUAS OBJECT IDENTIFIER ::= { mp7002AlarmData 14 } mp7002FEES OBJECT IDENTIFIER ::= { mp7002AlarmData 15 } mp7002FEBBE OBJECT IDENTIFIER ::= { mp7002AlarmData 16 } mp7002FESES OBJECT IDENTIFIER ::= { mp7002AlarmData 17 } mp7002FEUAS OBJECT IDENTIFIER ::= { mp7002AlarmData 18 } mp7002RAI OBJECT IDENTIFIER ::= { mp7002AlarmData 19 } -- ALARM Maskable Valid interfaces window/thres -- ==================================================================================== -- mp7002NoResponseAlm no unit no -- mp7002DiagRxErrAlm no unit no -- mp7002PowerUpAlm no unit no -- mp7002NvRamCorrupt no unit no -- mp7002UnitFailure no unit no -- mp7002TimingLoss yes unit no -- mp7002LCV yes E1 no -- mp7002LossofSignal yes E1/E1X no -- mp7002LossOfFrame yes E1/E1X no -- mp7002Ais yes E1/E1X no -- mp7002NEES yes E1/E1X yes -- mp7002NEBBE yes E1/E1X yes -- mp7002NESES yes E1/E1X yes -- mp7002NEUAS yes E1/E1X yes -- mp7002FEES yes E1/E1X yes -- mp7002FEBBE yes E1/E1X yes -- mp7002FESES yes E1/E1X yes -- mp7002FEUAS yes E1/E1X yes -- mp7002RAI yes E1 no -- -- -- ******************************************************************** -- GDC MP7002 Alarm Configuration -- ******************************************************************** mp7002NearEndAlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002NearEndAlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The mp7002NearEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table." ::= { mp7002Alarms 2 } mp7002NearEndAlarmConfigEntry OBJECT-TYPE SYNTAX Mp7002NearEndAlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the MP7002 Alarm Configuration table." INDEX { mp7002NearEndAlarmConfigIndex, mp7002NearEndAlarmConfigIdentifier } ::= { mp7002NearEndAlarmConfigTable 1 } Mp7002NearEndAlarmConfigEntry ::= SEQUENCE { mp7002NearEndAlarmConfigIndex SCinstance, mp7002NearEndAlarmConfigIdentifier OBJECT IDENTIFIER, mp7002NearEndAlarmCountWindow INTEGER, mp7002NearEndAlarmCountThreshold INTEGER } mp7002NearEndAlarmConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable." ::= { mp7002NearEndAlarmConfigEntry 1 } -- mp7002NearEndAlarmConfigIdentifier OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm." ::= { mp7002NearEndAlarmConfigEntry 2 } mp7002NearEndAlarmCountWindow OBJECT-TYPE SYNTAX INTEGER{ disabled(1), last1sec(2), last10sec(3), last30sec(4), last1min(5), last15min(6), last1hr(7), last24hr(8), infinite(9) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Default: disabled(1)" ::= { mp7002NearEndAlarmConfigEntry 3 } mp7002NearEndAlarmCountThreshold OBJECT-TYPE SYNTAX INTEGER { thresGT1(1), thresGT3(2), thresGT10(3), thresGT100(4), thresGT1000(5), thresGT10000(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Default: thresGT1(1)" ::= { mp7002NearEndAlarmConfigEntry 4 } mp7002FarEndAlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002FarEndAlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The mp7002FarEndAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table." ::= { mp7002Alarms 3 } mp7002FarEndAlarmConfigEntry OBJECT-TYPE SYNTAX Mp7002FarEndAlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the MP7002 Alarm Configuration table." INDEX { mp7002FarEndAlarmConfigIndex, mp7002FarEndAlarmConfigIdentifier } ::= { mp7002FarEndAlarmConfigTable 1 } Mp7002FarEndAlarmConfigEntry ::= SEQUENCE { mp7002FarEndAlarmConfigIndex SCinstance, mp7002FarEndAlarmConfigIdentifier OBJECT IDENTIFIER, mp7002FarEndAlarmCountWindow INTEGER, mp7002FarEndAlarmCountThreshold INTEGER } -- mp7002FarEndAlarmConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable." ::= { mp7002FarEndAlarmConfigEntry 1 } mp7002FarEndAlarmConfigIdentifier OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y) where xxx(x) is the administratively assigned family object identifier (z) is the object identifier for alarms in the family defined MIB and yyy(y) is the administratively assigned alarm type identifier for this alarm." ::= { mp7002FarEndAlarmConfigEntry 2 } mp7002FarEndAlarmCountWindow OBJECT-TYPE SYNTAX INTEGER{ disabled(1), last1sec(2), last10sec(3), last30sec(4), last1min(5), last15min(6), last1hr(7), last24hr(8), infinite(9) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Default: disabled(1)" ::= { mp7002FarEndAlarmConfigEntry 3 } -- mp7002FarEndAlarmCountThreshold OBJECT-TYPE SYNTAX INTEGER { thresGT1(1), thresGT3(2), thresGT10(3), thresGT100(4), thresGT1000(5), thresGT10000(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active. Default: thresGT1(1)" ::= { mp7002FarEndAlarmConfigEntry 4 } -- -- ******************************************************************** -- GDC Local MP7002 Alarm Configuration -- ******************************************************************** mp7002LocalAlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Mp7002LocalAlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The mp7002LocalAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table." ::= { mp7002Alarms 4 } mp7002LocalAlarmConfigEntry OBJECT-TYPE SYNTAX Mp7002LocalAlarmConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the GDC Local Alarm Configuration table." INDEX { mp7002LocalAlarmConfigIndex } ::= { mp7002LocalAlarmConfigTable 1 } Mp7002LocalAlarmConfigEntry ::= SEQUENCE { mp7002LocalAlarmConfigIndex SCinstance, mp7002UASNE INTEGER, mp7002SESNE INTEGER, mp7002BBENE INTEGER, mp7002ESNE INTEGER, mp7002UASFE INTEGER, mp7002SESFE INTEGER, mp7002BBEFE INTEGER, mp7002ESFE INTEGER, mp7002LOS INTEGER, mp7002LOF INTEGER, mp7002AIS INTEGER, mp7002TmgLoss INTEGER, mp7002LCVs INTEGER, mp7002NtwkRAI INTEGER } mp7002LocalAlarmConfigIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the interface to which this entry is applicable." ::= { mp7002LocalAlarmConfigEntry 1 } mp7002UASNE OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 2 } -- mp7002SESNE OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 3 } mp7002BBENE OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 4 } mp7002ESNE OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 5 } mp7002UASFE OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 6 } -- mp7002SESFE OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 7 } mp7002BBEFE OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 8 } mp7002ESFE OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 9 } mp7002LOS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 10 } -- mp7002LOF OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 11 } mp7002AIS OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 12 } mp7002TmgLoss OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 13 } mp7002LCVs OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 14 } mp7002NtwkRAI OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledMajor(2), enabledMinor(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Disables or enables the alarm on the Major buss or Minor buss." ::= { mp7002LocalAlarmConfigEntry 15 } END