Organization: Alentis Electronics

Last Updated: 2016-08-24

Category: Domain: Environmental Monitoring, Vendor: NetPing/DKSF

Description: MIB for DKSF-70 NetPing device firmware 6.x providing expanded sensor, relay, and environmental monitoring features.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is DKSF-70-6-X-X-1?

DKSF-70-6-X-X-1 is the MIB for the NetPing DKSF-70 device family running firmware 6.x, a remote sensing and control unit used for environmental and equipment monitoring over the network (branded under the "lightcom" enterprise tree). It exposes relay control objects (state, mode, memo, reset behavior) for controlling connected switches/power outlets, thermal sensor objects for reading temperature values from attached probes, and trap configuration for email alerting. Its monitoring focus is squarely on physical/environmental hardware status: reading temperature from npThermoTable sensors and relay on/off state from npRelayTable lets an operator watch equipment-room conditions and remotely toggle power to connected devices, functioning much like an environmental monitoring/PDU controller appliance. It is a self-contained proprietary NetPing MIB with no strong dependency on other standard MIBs evident in the object set. It is typically deployed in server rooms, telecom cabinets, or remote sites where temperature and relay-controlled equipment (fans, heaters, power resets) need remote SNMP monitoring and control. Engineers can download the DKSF-70-6-X-X-1 file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in DKSF-70-6-X-X-1. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • NetPing DKSF-70 environmental sensing/relay controller

Monitoring Examples

An administrator would poll npThermoTable/npThermoEntry, indexed by npThermoSensorN, to read npThermoValue for each attached temperature probe and alert if a room or rack temperature exceeds a safe threshold. Checking npRelayTable/npRelayEntry (indexed by npRelayN) for npRelayState and npRelayMode reveals whether a connected relay-controlled device (like a fan or backup heater) is currently on or off, and npRelayStartReset can be used to trigger a remote power-cycle of attached equipment. Configuring npTrapEmailTo ensures that when npTrapInfo notifications fire (e.g., an over-temperature event), an email alert is sent to the on-call administrator.

What Can Be Monitored

  • temperature sensor readings
  • relay on/off state
  • relay mode configuration
  • relay reset/power-cycle control
  • trap email notification configuration
Imported Objects

From SNMPv2-MIB

snmpTrapsOBJECT-IDENTITY

From SNMPv2-SMI

Counter32
Counter64
Gauge32
Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
TimeTicks
enterprises

From SNMPv2-TC

DisplayString
TEXTUAL-CONVENTION
TimeStamp
TruthValue

How to Use in IPNetwork Monitor

Example using npIoPulseCounter OID:

Select a NetPing DKSF-70 environmental sensing/relay controller as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type npIoPulseCounter into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the pulse Counter on IO input line (counts positive fronts) Write 0 to reset. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Generic NetPing remote sensing and control MIB for temperature, relays, IO lines, and GSM functions.

Start monitoring NetPing DKSF-70 environmental sensing/relay controller with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download DKSF-70-6-X-X-1