All MIBs › CONFIG-READER4UWG-MIB2
Organization: Sun Microsystems Inc.
Last Updated: 2006-09-20
Category: Domain: Server Hardware
Description: Configuration reader MIB for UWG devices enabling SNMP-based retrieval of device configuration parameters.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CONFIG-READER4UWG-MIB2?
This MIB provides SNMP-based read access to system configuration and hardware inventory information on Sun/Oracle "UWG" platforms, drawing on Sun's PICL (Platform Information and Control Library) framework given objects like picldStatus and systemsunSmTreeProp. It exposes static and semi-static configuration data such as operating system name and version, hostname, machine/platform/architecture identifiers, system clock frequency, serial number, and general hardware/module inventory. Its monitoring value lies mainly in software/hardware identification and configuration auditing - confirming OS version, platform/hardware model, and PICL subsystem status - rather than dynamic performance counters. It is dependent on Sun's PICL infrastructure (picldStatus) for its underlying data source, tying this MIB closely to Solaris/Sun hardware management conventions. It is typically deployed in Solaris/Sun (or compatible UWG-branded) server environments where administrators need to inventory or audit system configuration via SNMP, using the CONFIG-READER4UWG-MIB2 MIB to expose these configuration objects to their monitoring tools.
IPNetwork Monitor allows you to monitor SNMP objects defined in CONFIG-READER4UWG-MIB2. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Sun/Oracle Solaris server (UWG platform)
- PICL-capable Sun hardware
Monitoring Examples
An administrator would poll oSversion, architecture, and platform together with hostname and serialnumber to build an inventory record or confirm a system matches its expected OS build and hardware model. The picldStatus object indicates whether the underlying PICL configuration-reading subsystem is functioning, so a failed status there would mean the rest of the configuration data (systemclockfrequency, machine, hardware/modules info) may be stale or unavailable. This makes the MIB useful primarily for configuration verification and asset tracking rather than live performance monitoring.
What Can Be Monitored
- OS name and version
- hostname and platform/architecture
- system clock frequency
- hardware serial number
- PICL subsystem read status
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| enterprises |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| activeled | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.31 | |||
| STR activeledstate | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.31.3 | DisplayString | read-only | Character string value |
| STR activeledsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.31.2 | DisplayString | read-only | Character string value |
| STR activeledsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.31.1 | DisplayString | read-only | Character string value |
| STR addrem | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.47.14.1.4 | DisplayString | read-only | Character string value |
| addremTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.47.14 | not-accessible | MIB tree branch | |
| addremTblEntry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.47.14.1 | not-accessible | MIB tree branch | |
| I32 addremTblentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.47.14.1.1 | Integer32 | read-only | Integer value |
| afb | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.28 | not-accessible | MIB tree branch | |
| afbentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.28.1 | not-accessible | MIB tree branch | |
| STR afbentrybuffer | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.28.1.4 | DisplayString | read-only | Character string value |
| STR afbentrydevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.28.1.5 | DisplayString | read-only | Character string value |
| STR afbentrymodel | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.28.1.6 | DisplayString | read-only | Character string value |
| I32 afbentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.28.1.3 | Integer32 | read-only | Integer value |
| STR afbentrypathnameelement | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.28.1.7 | DisplayString | read-only | Character string value |
| STR afbentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.28.1.2 | DisplayString | read-only | Character string value |
| STR afbentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.28.1.1 | DisplayString | read-only | Character string value |
| agent | 1.3.6.1.4.1.42.2.12.2 | |||
| STR architecture | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.6 | DisplayString | read-only | Character string value |
| bank | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.18 | |||
| bankentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.18.1.1 | not-accessible | MIB tree branch | |
| STR bankentrydevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.18.1.1.5 | DisplayString | read-only | Character string value |
| STR bankentryfrudevice | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.18.1.1.6 | DisplayString | read-only | Character string value |
| I32 bankentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.18.1.1.3 | Integer32 | read-only | Integer value |
| STR bankentryStatus | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.18.1.1.7 | DisplayString | read-only | Character string value |
| STR bankentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.18.1.1.2 | DisplayString | read-only | Character string value |
| STR bankentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.18.1.1.1 | DisplayString | read-only | Character string value |
| STR banksize | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.18.1.1.4 | DisplayString | read-only | Character string value |
| bankTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.18.1 | not-accessible | MIB tree branch | |
| STR boardreferencenumber | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1.1.4 | DisplayString | read-only | Character string value |
| STR boardtype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.7 | DisplayString | read-only | Character string value |
| config | 1.3.6.1.4.1.42.2.12.2.2.1.1 | |||
| cpufanentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1 | not-accessible | MIB tree branch | |
| cpufans | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24 | |||
| cpufansTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1 | not-accessible | MIB tree branch | |
| I32 cpufansTblentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1.3 | Integer32 | read-only | Integer value |
| STR cpufansTblfanentryStatus | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1.4 | DisplayString | read-only | Character string value |
| I32 cpufansTblspeed | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1.5 | Integer32 | read-only | Integer value |
| STR cpufansTblsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1.2 | DisplayString | read-only | Character string value |
| STR cpufansTblsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1.1 | DisplayString | read-only | Character string value |
| STR cputype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.5 | DisplayString | read-only | Character string value |
| cpuunit | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15 | |||
| cpuunitentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1 | not-accessible | MIB tree branch | |
| STR cpuunitentryclockfrequency | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.4 | DisplayString | read-only | Character string value |
| STR cpuunitentrydevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.7 | DisplayString | read-only | Character string value |
| I32 cpuunitentryentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.3 | Integer32 | read-only | Integer value |
| STR cpuunitentryfru | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.9 | DisplayString | read-only | Character string value |
| STR cpuunitentrymodel | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.11 | DisplayString | read-only | Character string value |
| STR cpuunitentrypathnameelement | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.12 | DisplayString | read-only | Character string value |
| STR cpuunitentryStatus | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.14 | DisplayString | read-only | Character string value |
| STR cpuunitentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.2 | DisplayString | read-only | Character string value |
| STR cpuunitentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.1 | DisplayString | read-only | Character string value |
| STR cpuunitentryunitunit | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.15 | DisplayString | read-only | Character string value |
| STR cpuunitentryupaportid | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.17 | DisplayString | read-only | Character string value |
| cpuunitTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1 | not-accessible | MIB tree branch | |
| STR dAC | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.5 | DisplayString | read-only | Character string value |
| STR dcachesize | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.6 | DisplayString | read-only | Character string value |
| dimm | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19 | |||
| dimmentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1 | not-accessible | MIB tree branch | |
| STR dimmentrydevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1.4 | DisplayString | read-only | Character string value |
| I32 dimmentryerrorcount | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1.19 | Integer32 | read-only | Integer value |
| STR dimmentryfru | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1.5 | DisplayString | read-only | Character string value |
| STR dimmentryfrudevice | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1.6 | DisplayString | read-only | Character string value |
| I32 dimmentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1.3 | Integer32 | read-only | Integer value |
| STR dimmentryStatus | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1.9 | DisplayString | read-only | Character string value |
| STR dimmentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1.2 | DisplayString | read-only | Character string value |
| STR dimmentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1.1 | DisplayString | read-only | Character string value |
| dimmTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1 | not-accessible | MIB tree branch | |
| disk | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51 | |||
| STR diskcount | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.5 | DisplayString | read-only | Character string value |
| diskEntry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1 | not-accessible | MIB tree branch | |
| diskerrorled | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.32 | |||
| STR diskerrorledstate | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.32.3 | DisplayString | read-only | Character string value |
| STR diskerrorledsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.32.2 | DisplayString | read-only | Character string value |
| STR diskerrorledsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.32.1 | DisplayString | read-only | Character string value |
| STR diskname | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.5 | DisplayString | read-only | Character string value |
| diskstatusleds | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.38 | not-accessible | MIB tree branch | |
| diskstatusledsentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.38.1 | not-accessible | MIB tree branch | |
| I32 diskstatusledsentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.38.1.3 | Integer32 | read-only | Integer value |
| STR diskstatusledssunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.38.1.2 | DisplayString | read-only | Character string value |
| STR diskstatusledssunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.38.1.1 | DisplayString | read-only | Character string value |
| diskTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1 | not-accessible | MIB tree branch | |
| STR diskTbldevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.4 | DisplayString | read-only | Character string value |
| I32 diskTblentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.3 | Integer32 | read-only | Integer value |
| STR diskTblfru | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.6 | DisplayString | read-only | Character string value |
| I32 diskTblharderrors | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.11 | Integer32 | read-only | Integer value |
| STR diskTblinstance | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.7 | DisplayString | read-only | Character string value |
| STR diskTblnodehierarchy | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.8 | DisplayString | read-only | Character string value |
| I32 diskTblsofterrors | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.10 | Integer32 | read-only | Integer value |
| STR diskTblsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.2 | DisplayString | read-only | Character string value |
| STR diskTblsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.1 | DisplayString | read-only | Character string value |
| STR diskTbltarget | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.9 | DisplayString | read-only | Character string value |
| I32 diskTbltransporterrors | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.51.1.1.12 | Integer32 | read-only | Integer value |
| STR ecachesize | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.8 | DisplayString | read-only | Character string value |
| STR ether | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.6 | DisplayString | read-only | Character string value |
| fan | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.26 | not-accessible | MIB tree branch | |
| fanentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.26.1 | not-accessible | MIB tree branch | |
| I32 fanentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.26.1.3 | Integer32 | read-only | Integer value |
| STR fanentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.26.1.2 | DisplayString | read-only | Character string value |
| STR fanentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.26.1.1 | DisplayString | read-only | Character string value |
| STR fantblfanentryStatus | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.26.1.4 | DisplayString | read-only | Character string value |
| STR fBCversion | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.6 | DisplayString | read-only | Character string value |
| ffb | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.27 | not-accessible | MIB tree branch | |
| ffbentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.27.1 | not-accessible | MIB tree branch | |
| STR ffbentrybuffer | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.27.1.4 | DisplayString | read-only | Character string value |
| STR ffbentrydevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.27.1.5 | DisplayString | read-only | Character string value |
| STR ffbentrymodel | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.27.1.6 | DisplayString | read-only | Character string value |
| I32 ffbentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.27.1.3 | Integer32 | read-only | Integer value |
| STR ffbentrypathnameelement | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.27.1.7 | DisplayString | read-only | Character string value |
| STR ffbentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.27.1.2 | DisplayString | read-only | Character string value |
| STR ffbentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.27.1.1 | DisplayString | read-only | Character string value |
| genericdevice | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.55 | |||
| genericdeviceentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.55.1.1 | not-accessible | MIB tree branch | |
| genericdeviceTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.55.1 | not-accessible | MIB tree branch | |
| I32 genericdeviceTblentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.55.1.1.3 | Integer32 | read-only | Integer value |
| STR genericdeviceTblpathnameelement | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.55.1.1.4 | DisplayString | read-only | Character string value |
| STR genericdeviceTblsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.55.1.1.2 | DisplayString | read-only | Character string value |
| STR genericdeviceTblsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.55.1.1.1 | DisplayString | read-only | Character string value |
| generrorled | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.33 | |||
| STR generrorledstate | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.33.3 | DisplayString | read-only | Character string value |
| STR generrorledsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.33.2 | DisplayString | read-only | Character string value |
| STR generrorledsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.33.1 | DisplayString | read-only | Character string value |
| hardware | 1.3.6.1.4.1.42.2.12.2.2.1 | |||
| hardwarerules | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.47 | |||
| STR height | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.10 | DisplayString | read-only | Character string value |
| STR hostname | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.7 | DisplayString | read-only | Character string value |
| STR icachesize | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.10 | DisplayString | read-only | Character string value |
| STR inet | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.7 | DisplayString | read-only | Character string value |
| I32 inputerrors | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.12 | Integer32 | read-only | Integer value |
| STR interfacename | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.8 | DisplayString | read-only | Character string value |
| iocontroller | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49 | |||
| iocontrollerTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1 | not-accessible | MIB tree branch | |
| STR iocontrollerTblboardnum | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.4 | DisplayString | read-only | Character string value |
| STR iocontrollerTblclockfrequency | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.5 | DisplayString | read-only | Character string value |
| STR iocontrollerTbldevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.6 | DisplayString | read-only | Character string value |
| iocontrollerTblEntry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1 | not-accessible | MIB tree branch | |
| I32 iocontrollerTblentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.3 | Integer32 | read-only | Integer value |
| STR iocontrollerTblfru | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.13 | DisplayString | read-only | Character string value |
| STR iocontrollerTblinstance | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.7 | DisplayString | read-only | Character string value |
| STR iocontrollerTblmodel | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.8 | DisplayString | read-only | Character string value |
| STR iocontrollerTblreg | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.9 | DisplayString | read-only | Character string value |
| STR iocontrollerTblsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.2 | DisplayString | read-only | Character string value |
| STR iocontrollerTblsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.1 | DisplayString | read-only | Character string value |
| STR iocontrollerTblupaportid | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.11 | DisplayString | read-only | Character string value |
| iodevice | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50 | |||
| iodeviceEntry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1 | not-accessible | MIB tree branch | |
| iodeviceTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1 | not-accessible | MIB tree branch | |
| STR iodeviceTbldevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.4 | DisplayString | read-only | Character string value |
| I32 iodeviceTblentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.3 | Integer32 | read-only | Integer value |
| STR iodeviceTblfru | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.12 | DisplayString | read-only | Character string value |
| STR iodeviceTblinstance | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.6 | DisplayString | read-only | Character string value |
| STR iodeviceTblmodel | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.7 | DisplayString | read-only | Character string value |
| STR iodeviceTblnodehierarchy | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.8 | DisplayString | read-only | Character string value |
| STR iodeviceTblreg | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.10 | DisplayString | read-only | Character string value |
| STR iodeviceTblsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.2 | DisplayString | read-only | Character string value |
| STR iodeviceTblsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.1 | DisplayString | read-only | Character string value |
| iounit | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.54 | not-accessible | MIB tree branch | |
| STR iounitboardnum | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.54.1.4 | DisplayString | read-only | Character string value |
| STR iounitdeviceid | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.54.1.5 | DisplayString | read-only | Character string value |
| iounitEntry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.54.1 | not-accessible | MIB tree branch | |
| I32 iounitentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.54.1.3 | Integer32 | read-only | Integer value |
| STR iounitinstance | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.54.1.6 | DisplayString | read-only | Character string value |
| STR iounitreg | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.54.1.7 | DisplayString | read-only | Character string value |
| STR iounitsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.54.1.2 | DisplayString | read-only | Character string value |
| STR iounitsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.54.1.1 | DisplayString | read-only | Character string value |
| keyswitch | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.30 | |||
| STR keyswitchsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.30.2 | DisplayString | read-only | Character string value |
| STR keyswitchsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.30.1 | DisplayString | read-only | Character string value |
| STR machine | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.8 | DisplayString | read-only | Character string value |
| mc | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.17 | |||
| mcentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.17.1.1 | not-accessible | MIB tree branch | |
| STR mcentrydevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.17.1.1.4 | DisplayString | read-only | Character string value |
| STR mcentryfrudevice | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.17.1.1.5 | DisplayString | read-only | Character string value |
| I32 mcentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.17.1.1.3 | Integer32 | read-only | Integer value |
| STR mcentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.17.1.1.2 | DisplayString | read-only | Character string value |
| STR mcentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.17.1.1.1 | DisplayString | read-only | Character string value |
| mcTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.17.1 | not-accessible | MIB tree branch | |
| memory | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.20 | not-accessible | MIB tree branch | |
| memoryentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.20.1 | not-accessible | MIB tree branch | |
| I32 memoryentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.20.1.3 | Integer32 | read-only | Integer value |
| STR memoryentrypathnameelement | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.20.1.4 | DisplayString | read-only | Character string value |
| STR memoryentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.20.1.2 | DisplayString | read-only | Character string value |
| STR memoryentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.20.1.1 | DisplayString | read-only | Character string value |
| modules | 1.3.6.1.4.1.42.2.12.2.2 | |||
| STR modulesize | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1.7 | DisplayString | read-only | Character string value |
| network | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53 | |||
| STR networkcount | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.9 | DisplayString | read-only | Character string value |
| networkEntry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1 | not-accessible | MIB tree branch | |
| networkTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1 | not-accessible | MIB tree branch | |
| STR networkTbldevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.4 | DisplayString | read-only | Character string value |
| I32 networkTblentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.3 | Integer32 | read-only | Integer value |
| STR networkTblfru | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.5 | DisplayString | read-only | Character string value |
| STR networkTblnodehierarchy | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.9 | DisplayString | read-only | Character string value |
| STR networkTblreg | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.11 | DisplayString | read-only | Character string value |
| STR networkTblsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.2 | DisplayString | read-only | Character string value |
| STR networkTblsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.1 | DisplayString | read-only | Character string value |
| STR nodename | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.47.14.1.3 | DisplayString | read-only | Character string value |
| STR os | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.3 | DisplayString | read-only | Character string value |
| STR oSversion | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.4 | DisplayString | read-only | Character string value |
| I32 outputerrors | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.13 | Integer32 | read-only | Integer value |
| picld | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.1 | |||
| I32 picldStatus | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.1.1 | Integer32 | read-only | Integer value |
| STR platform | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.9 | DisplayString | read-only | Character string value |
| STR position | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.30.3 | DisplayString | read-only | Character string value |
| powerled | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.34 | |||
| STR powerledstate | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.34.3 | DisplayString | read-only | Character string value |
| STR powerledsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.34.2 | DisplayString | read-only | Character string value |
| STR powerledsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.34.1 | DisplayString | read-only | Character string value |
| powersupply | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.22 | |||
| powersupplyentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.22.1.1 | not-accessible | MIB tree branch | |
| STR powersupplyentryfru | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.22.1.1.4 | DisplayString | read-only | Character string value |
| I32 powersupplyentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.22.1.1.3 | Integer32 | read-only | Integer value |
| STR powersupplyentrystate | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.22.1.1.5 | DisplayString | read-only | Character string value |
| STR powersupplyentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.22.1.1.2 | DisplayString | read-only | Character string value |
| powersupplyfans | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.25 | |||
| powersupplyfansTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.25.1 | not-accessible | MIB tree branch | |
| powersupplyTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.22.1 | not-accessible | MIB tree branch | |
| STR processorid | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.13 | DisplayString | read-only | Character string value |
| prod | 1.3.6.1.4.1.42.2 | |||
| pserrorled | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.35 | |||
| STR pserrorledstate | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.35.3 | DisplayString | read-only | Character string value |
| STR pserrorledsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.35.2 | DisplayString | read-only | Character string value |
| STR pserrorledsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.35.1 | DisplayString | read-only | Character string value |
| psfanentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.25.1.1 | not-accessible | MIB tree branch | |
| I32 psfanentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.25.1.1.3 | Integer32 | read-only | Integer value |
| STR psfanentryStatus | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.25.1.1.4 | DisplayString | read-only | Character string value |
| STR psfanentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.25.1.1.2 | DisplayString | read-only | Character string value |
| STR psfanentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.25.1.1.1 | DisplayString | read-only | Character string value |
| STR rcr4u209 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.47.1 | DisplayString | read-only | No Data Value |
| STR rcr4u290 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.47.2 | DisplayString | read-only | No Data Value |
| reader4uwg | 1.3.6.1.4.1.42.2.12.2.2.1.1.3 | |||
| STR revision | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.12 | DisplayString | read-only | Character string value |
| rsc | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.46 | |||
| STR rscdevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.46.3 | DisplayString | read-only | Character string value |
| STR rscfrudevice | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.46.4 | DisplayString | read-only | Character string value |
| STR rschostname | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.46.6 | DisplayString | read-only | Character string value |
| STR rscname | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.46.5 | DisplayString | read-only | Character string value |
| STR rscsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.46.2 | DisplayString | read-only | Character string value |
| STR rscsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.46.1 | DisplayString | read-only | Character string value |
| STR sample | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.10 | DisplayString | read-only | Character string value |
| STR serialnumber | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.11 | DisplayString | read-only | Character string value |
| simm | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21 | |||
| simmentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1.1 | not-accessible | MIB tree branch | |
| I32 simmentryerrorcount | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1.1.21 | Integer32 | read-only | Integer value |
| STR simmentryfru | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1.1.5 | DisplayString | read-only | Character string value |
| I32 simmentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1.1.3 | Integer32 | read-only | Integer value |
| STR simmentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1.1.2 | DisplayString | read-only | Character string value |
| STR simmentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1.1.1 | DisplayString | read-only | Character string value |
| simmTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1 | not-accessible | MIB tree branch | |
| STR size | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1.1.6 | DisplayString | read-only | Character string value |
| STR slot | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1.1.7 | DisplayString | read-only | Character string value |
| STR socketname | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.19.1.1.8 | DisplayString | read-only | Character string value |
| sspentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.37.1 | not-accessible | MIB tree branch | |
| I32 sspentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.37.1.3 | Integer32 | read-only | Integer value |
| STR sspentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.37.1.2 | DisplayString | read-only | Character string value |
| STR sspentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.37.1.1 | DisplayString | read-only | Character string value |
| sun | 1.3.6.1.4.1.42 | |||
| STR sunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.22.1.1.1 | DisplayString | read-only | Character string value |
| sunsymon | 1.3.6.1.4.1.42.2.12 | |||
| sUNWffb | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29 | not-accessible | MIB tree branch | |
| sUNWffbentry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1 | not-accessible | MIB tree branch | |
| STR sUNWffbentrybuffer | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.8 | DisplayString | read-only | Character string value |
| STR sUNWffbentrydevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.9 | DisplayString | read-only | Character string value |
| STR sUNWffbentrymodel | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.11 | DisplayString | read-only | Character string value |
| I32 sUNWffbentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.3 | Integer32 | read-only | Integer value |
| STR sUNWffbentrysunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.2 | DisplayString | read-only | Character string value |
| STR sUNWffbentrysunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.1 | DisplayString | read-only | Character string value |
| STR sUNWffbentryupaportid | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.13 | DisplayString | read-only | Character string value |
| sUNWUltra1 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.4 | |||
| sUNWUltra10 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.7 | |||
| STR sUNWUltra10sunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.7.2 | DisplayString | read-only | Character string value |
| STR sUNWUltra10sunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.7.1 | DisplayString | read-only | Character string value |
| STR sUNWUltra1sunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.4.2 | DisplayString | read-only | Character string value |
| STR sUNWUltra1sunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.4.1 | DisplayString | read-only | Character string value |
| sUNWUltra2 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.5 | |||
| sUNWUltra250 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.9 | |||
| STR sUNWUltra250sunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.9.2 | DisplayString | read-only | Character string value |
| STR sUNWUltra250sunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.9.1 | DisplayString | read-only | Character string value |
| STR sUNWUltra2sunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.5.2 | DisplayString | read-only | Character string value |
| STR sUNWUltra2sunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.5.1 | DisplayString | read-only | Character string value |
| sUNWUltra4 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.12 | |||
| STR sUNWUltra4sunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.12.2 | DisplayString | read-only | Character string value |
| STR sUNWUltra4sunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.12.1 | DisplayString | read-only | Character string value |
| sUNWUltra5 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.6 | |||
| sUNWUltra510 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.8 | |||
| STR sUNWUltra510sunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.8.2 | DisplayString | read-only | Character string value |
| STR sUNWUltra510sunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.8.1 | DisplayString | read-only | Character string value |
| STR sUNWUltra5sunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.6.2 | DisplayString | read-only | Character string value |
| STR sUNWUltra5sunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.6.1 | DisplayString | read-only | Character string value |
| sUNWUltra60 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.10 | |||
| STR sUNWUltra60sunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.10.2 | DisplayString | read-only | Character string value |
| STR sUNWUltra60sunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.10.1 | DisplayString | read-only | Character string value |
| sUNWUltra80 | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.11 | |||
| STR sUNWUltra80sunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.11.2 | DisplayString | read-only | Character string value |
| STR sUNWUltra80sunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.11.1 | DisplayString | read-only | Character string value |
| STR symbolicname | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.53.1.1.10 | DisplayString | read-only | Character string value |
| system | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2 | |||
| systemboard | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.3 | |||
| STR systemboardfru | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.3.3 | DisplayString | read-only | Character string value |
| STR systemboardstate | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.3.4 | DisplayString | read-only | Character string value |
| STR systemboardsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.3.2 | DisplayString | read-only | Character string value |
| STR systemboardsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.3.1 | DisplayString | read-only | Character string value |
| STR systemclockfrequency | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.5 | DisplayString | read-only | Character string value |
| systemstatuspanel | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.37 | not-accessible | MIB tree branch | |
| STR systemsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.2 | DisplayString | read-only | Character string value |
| STR systemsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.1 | DisplayString | read-only | Character string value |
| tape | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52 | |||
| STR tapecount | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.50.1.1.11 | DisplayString | read-only | Character string value |
| tapeEntry | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1 | not-accessible | MIB tree branch | |
| STR tapeEntryStatus | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.10 | DisplayString | read-only | Character string value |
| STR tapename | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.9 | DisplayString | read-only | Character string value |
| tapeTbl | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1 | not-accessible | MIB tree branch | |
| STR tapeTbldevicetype | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.4 | DisplayString | read-only | Character string value |
| I32 tapeTblentryno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.3 | Integer32 | read-only | Integer value |
| STR tapeTblfru | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.5 | DisplayString | read-only | Character string value |
| I32 tapeTblharderrors | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.13 | Integer32 | read-only | Integer value |
| STR tapeTblinstance | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.6 | DisplayString | read-only | Character string value |
| STR tapeTblmodel | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.7 | DisplayString | read-only | Character string value |
| STR tapeTblnodehierarchy | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.8 | DisplayString | read-only | Character string value |
| I32 tapeTblsofterrors | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.12 | Integer32 | read-only | Integer value |
| STR tapeTblsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.2 | DisplayString | read-only | Character string value |
| STR tapeTblsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.1 | DisplayString | read-only | Character string value |
| STR tapeTbltarget | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.11 | DisplayString | read-only | Character string value |
| I32 tapeTbltransporterrors | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.52.1.1.14 | Integer32 | read-only | Integer value |
| STR temperature | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.15.1.1.16 | DisplayString | read-only | Character string value |
| temperrorled | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.36 | |||
| STR temperrorledstate | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.36.3 | DisplayString | read-only | Character string value |
| STR temperrorledsunSmNodeName | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.36.2 | DisplayString | read-only | Character string value |
| STR temperrorledsunSmTreeProp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.36.1 | DisplayString | read-only | Character string value |
| STR timestamp | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.12 | DisplayString | read-only | Character string value |
| STR timestampraw | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.13 | DisplayString | read-only | Character string value |
| I32 totalconfigchanges | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.19 | Integer32 | read-only | Integer value |
| STR totaldisks | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.14 | DisplayString | read-only | Character string value |
| STR totalmemory | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.15 | DisplayString | read-only | Character string value |
| I32 totalmodelchanges | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.18 | Integer32 | read-only | Integer value |
| STR totalprocessors | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.16 | DisplayString | read-only | Character string value |
| STR totaltapedevices | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.2.17 | DisplayString | read-only | Character string value |
| STR type | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.21.1.1.8 | DisplayString | read-only | Character string value |
| STR uniqueid | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.47.14.1.2 | DisplayString | read-only | Character string value |
| STR upamid | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.10 | DisplayString | read-only | Character string value |
| STR versionno | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.49.1.1.12 | DisplayString | read-only | Character string value |
| STR width | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.14 | DisplayString | read-only | Character string value |
| STR xDRAM | 1.3.6.1.4.1.42.2.12.2.2.1.1.3.29.1.4 | DisplayString | read-only | Character string value |
RFC description
Sun Microsystems configuration reader MIB for Universal Web Graph hardware configuration monitoring.
Start monitoring Sun/Oracle Solaris server (UWG platform, PICL) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.