All MIBs › CONFIG-READER4UWG-MIB2 › cpufansTblsunSmNodeName
cpufansTblsunSmNodeName
Module: CONFIG-READER4UWG-MIB2
OID (symbolic): CONFIG-READER4UWG-MIB2::cpufansTblsunSmNodeName
OID (numeric): 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1.2
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: Character string value
What is cpufansTblsunSmNodeName?
cpufansTblsunSmNodeName is a DisplayString giving the human-readable node name label for a CPU cooling fan entry in the CPU fan table's management object tree. An admin scanning the CPU fan table can read this label to know which specific CPU fan (e.g. by slot or position) a neighboring speed or status reading belongs to. For example, cpufansTblsunSmNodeName might return "cpu-fan0" so the admin can tell that a corresponding cpufansTblspeed reading of 0 RPM refers to that exact fan and not another one in the chassis.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1.2 snmpwalk -v2c -c public <target> CONFIG-READER4UWG-MIB2::cpufansTblsunSmNodeName
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1.2.1 snmpget -v2c -c public <target> CONFIG-READER4UWG-MIB2::cpufansTblsunSmNodeName.1
Start monitoring Sun/Oracle Solaris server (UWG platform, PICL) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CONFIG-READER4UWG-MIB2::cpufansTblsunSmNodeName OID value, configure state conditions and alerts, and monitor any Sun/Oracle Solaris server (UWG platform, PICL) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.42 | sun | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2 | prod | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2.12 | sunsymon | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2.12.2 | agent | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2.12.2.2 | modules | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2.12.2.2.1 | hardware | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2.12.2.2.1.1 | config | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2.12.2.2.1.1.3 | reader4uwg | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24 | cpufans | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1 | cpufansTbl | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1 | cpufanentry | CONFIG-READER4UWG-MIB2 |
| 1.3.6.1.4.1.42.2.12.2.2.1.1.3.24.1.1.2 | cpufansTblsunSmNodeName | CONFIG-READER4UWG-MIB2 |