All MIBs › APPIAN-PPORT-SONET-MIB
Organization: Appian Communications, Inc.
Last Updated: 2000-02-23
Category: Optical and WDM, Vendor: Appian
Description: Covers section, line, and path performance management for physical SONET ports on Appian Communications equipment.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is APPIAN-PPORT-SONET-MIB?
APPIAN-PPORT-SONET-MIB is a vendor-specific MIB from Appian Communications that covers section, line, and path-layer performance management for physical SONET/SDH ports on Appian's optical access equipment, built on the standard PerfHist-TC-MIB textual conventions for interval-based counters. It defines acSonetPortTable for per-port administrative/operational status, medium line coding/type, loopback configuration, and ring identification; acSonetThresholdTable for configurable severely-errored-second thresholds; acSonetDCCTable for section/line/Appian data-communications-channel enable and failure state; and matching acSonetSection15MinuteIntervalTable and acSonetSectionDayIntervalTable structures reporting errored seconds (ESs), severely errored seconds (SESs), severely errored framing seconds (SEFSs), and coding violations (CVs) per 15-minute and daily bucket. This gives operators the granular, standards-aligned performance history needed to spot degrading SONET links (rising SES/SEFS counts) well before a port fails outright, similar in spirit to the standard SONET-MIB but scoped to Appian's port/slot/node addressing scheme. It depends on Appian's own APPIAN-SMI-MIB for node/slot/port indexing types and is deployed on Appian SONET/SDH access platforms in metro optical networks. Operators standardizing on Appian gear can download the APPIAN-PPORT-SONET-MIB file to pull it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in APPIAN-PPORT-SONET-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Appian Communications SONET/SDH access platforms
Monitoring Examples
An operator polls acSonetSection15MinuteIntervalSESs and acSonetSection15MinuteIntervalSEFSs for a given acSonetPortNodeId/Slot/Port, comparing recent intervals against acSonetThresholdSESSet; a run of intervals exceeding the configured SES threshold indicates a degrading SONET section that is likely to trigger a line/path alarm soon.
What Can Be Monitored
- errored/severely-errored second counters per interval
- severely errored framing second counts
- coding violation counts
- section/line data-communications-channel failure state
- port admin/operational status and loopback configuration
This MIB depends on
Related MIBs
Imported Objects
From APPIAN-SMI-MIB
| AcAdminStatus | |
| AcNodeId | |
| AcOpStatus | |
| AcPortNumber | |
| AcSlotNumber | |
| acPport | OBJECT-IDENTITY |
From PerfHist-TC-MIB
| PerfIntervalCount |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString | |
| TEXTUAL-CONVENTION | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| acSonet | 1.3.6.1.4.1.2785.2.3.6 | The MIB module to describe SONET/SDH objects. | ||
| acSonetObjects | 1.3.6.1.4.1.2785.2.3.6.1 | |||
| acSonetPort | 1.3.6.1.4.1.2785.2.3.6.1.1 | |||
| acSonetPortTable | 1.3.6.1.4.1.2785.2.3.6.1.1.1 | not-accessible | The SONET/SDH Port table which must be created by the management client. | |
| acSonetPortEntry | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1 | not-accessible | An entry in the SONET/SDH Port table. | |
| ACN acSonetPortNodeId | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetPortSlot | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetPortPort | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| ACA acSonetPortAdminStatus | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.4 | AcAdminStatus | read-create | Appian Administrative Status attribute used to set the provisioning state as either activate(1), inactivate(2) or delete(3). Refer to the Appian-SMI.mib file for additional information. |
| ACO acSonetPortOpStatus | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.5 | AcOpStatus | read-only | The current operational status for the SONET module controlling this port. |
| INT acSonetPortOpCode | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.6 | INTEGER | read-only | Provides a detailed status code which can be used to isolate a problem or state condition reported in acSonetPortOpStatus. |
| INT acSonetPortMediumType | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.7 | INTEGER | read-create | This variable identifies whether a SONET or a SDH signal is used across this interface. |
| I32 acSonetPortTimeElapsed | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.8 | Integer32 | read-only | The number of seconds, including partial seconds, that have elapsed since the beginning of the current measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value. |
| I32 acSonetPortValidIntervals | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.9 | Integer32 | read-only | The number of previous 15-minute intervals for which data was collected. A SONET/SDH interface must be capable of supporting at least n intervals. The minimum value of n is 4. The default of n is 32. The maximum value of n is 96. The value will be unless the measurement was (re-)started within the last (*15) minutes, in which case the value will be the number of complete 15 minute intervals for which the agent has at least some data. In certain cases (e.g., in the case where the agent is a proxy) it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available. |
| INT acSonetPortMediumLineCoding | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.10 | INTEGER | read-create | This variable describes the line coding for this interface. The B3ZS and CMI are used for electrical SONET/SDH signals (STS-1 and STS-3). The Non-Return to Zero (NRZ) and the Return to Zero are used for optical SONET/SDH signals. |
| INT acSonetPortMediumLineType | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.11 | INTEGER | read-create | This variable describes the line type for this interface. The line types are Short and Long Range Single Mode fiber or Multi-Mode fiber interfaces, and coax and UTP for electrical interfaces. The value acSonetOther should be used when the Line Type is not one of the listed values. |
| T/F acSonetPortTransmitterEnable | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.12 | TruthValue | read-create | Turns the laser on and off. |
| STR acSonetPortCircuitIdentifier | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.13 | DisplayString | read-create | This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting. Note that the circuit identifier, if available, is also represented by ifPhysAddress. |
| I32 acSonetPortInvalidIntervals | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.14 | Integer32 | read-only | The number of intervals in the range from 0 to acSonetPortValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals are not available (e.g., in proxy situations). |
| INT acSonetPortLoopbackConfig | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.15 | INTEGER | read-create | The current loopback state of the SONET/SDH interface. The values mean: none(0) Not in the loopback state. A device that is not capable of performing a loopback on this interface shall always return this value. facility(1) The received signal at this interface is looped back out through the corresponding transmitter in the return direction. terminal(2) The signal that is about to be transmitted is connected to the associated incoming receiver. other(3) Loopbacks that are not defined here. |
| T/F acSonetPortResetCurrentPMregs | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.16 | TruthValue | read-create | Reset Performance Monitoring Registers for current 15 minute and day to zero for entity-related statisics. Reset on receiving a 1, will automatically go to 0 at next 15 minute or day interval. |
| T/F acSonetPortResetAllPMregs | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.17 | TruthValue | read-create | Reset Performance Monitoring Registers to zero for all entity-related statisics. Reset on receiving a 1, will automatically go to 0 at next 15 minute or day interval. |
| INT acSonetPortConnectionType | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.18 | INTEGER | read-create | Whether the port is used on the ring side or the interconnect side. An interconnect interface is the one that connects to the ADM. |
| INT acSonetPortRingIdentifier | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.19 | INTEGER | read-create | This is a number assigned by carrier. It is contained here as a convenience for carrier and the EMS. It is not used by the device. When used, this should be set in east facing port row in this table. It can also be optionally set in the west facing port row in this table but it must be the same as the set in the east facing port row. |
| STR acSonetPortRingName | 1.3.6.1.4.1.2785.2.3.6.1.1.1.1.20 | DisplayString | read-create | An ASCII text name up to 32 characters in length which is assigned to this optical ring. Like the RingIdentifier, this is contained here as a convenience for the carrier and the EMS. It is not used by the device. When used, this should be set in east facing port row in this table. It can also be optionally set in the west facing port row in this table but it must be the same as the set in the east facing port row. |
| acSonetThresholdTable | 1.3.6.1.4.1.2785.2.3.6.1.1.2 | not-accessible | The SONET/SDH Threshold Table. | |
| acSonetThresholdEntry | 1.3.6.1.4.1.2785.2.3.6.1.1.2.1 | not-accessible | An entry in the SONET/SDH Port Table. | |
| ACN acSonetThresholdNodeId | 1.3.6.1.4.1.2785.2.3.6.1.1.2.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetThresholdSlot | 1.3.6.1.4.1.2785.2.3.6.1.1.2.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetThresholdPort | 1.3.6.1.4.1.2785.2.3.6.1.1.2.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetThresholdSESSet | 1.3.6.1.4.1.2785.2.3.6.1.1.2.1.4 | INTEGER | read-write | An enumerated integer indicating which recognized set of thresholds that the agent uses for determining severely errored seconds and unavailable time. other(1) None of the following. Bellcore1991(2) Bellcore TR-NWT-000253, 1991 [32], or ANSI T1M1.3/93-005R2, 1993 [22]. See also Appendix B. ansi1993(3) ANSI T1.231, 1993 [31], or Bellcore GR-253-CORE, Issue 2, 1995 [34] itu1995(4) ITU Recommendation G.826, 1995 [33] ansi1997(5) ANSI T1.231, 1997 [35] If a manager changes the value of this object then the SES statistics collected prior to this change must be invalidated. |
| acSonetDCCTable | 1.3.6.1.4.1.2785.2.3.6.1.1.3 | not-accessible | The SONET/SDH DCC Table. | |
| acSonetDCCEntry | 1.3.6.1.4.1.2785.2.3.6.1.1.3.1 | not-accessible | An entry in the SONET/SDH Port Table. | |
| ACN acSonetDCCNodeId | 1.3.6.1.4.1.2785.2.3.6.1.1.3.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetDCCSlot | 1.3.6.1.4.1.2785.2.3.6.1.1.3.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetDCCPort | 1.3.6.1.4.1.2785.2.3.6.1.1.3.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| T/F acSonetDCCSectionEnable | 1.3.6.1.4.1.2785.2.3.6.1.1.3.1.4 | TruthValue | read-write | This variable indicates that the DCC for the section is enabled. |
| T/F acSonetDCCLineEnable | 1.3.6.1.4.1.2785.2.3.6.1.1.3.1.5 | TruthValue | read-write | This variable indicates that the DCC for the line is enabled. |
| T/F acSonetDCCAppianEnable | 1.3.6.1.4.1.2785.2.3.6.1.1.3.1.6 | TruthValue | read-write | This variable indicates that the Appian DCC is enabled. |
| T/F acSonetDCCSectionFail | 1.3.6.1.4.1.2785.2.3.6.1.1.3.1.7 | TruthValue | read-only | This variable indicates that the DCC for the section has failed. |
| T/F acSonetDCCLineFail | 1.3.6.1.4.1.2785.2.3.6.1.1.3.1.8 | TruthValue | read-only | This variable indicates that the DCC for the line has failed. |
| T/F acSonetDCCAppianFail | 1.3.6.1.4.1.2785.2.3.6.1.1.3.1.9 | TruthValue | read-only | This variable indicates that the Appian DCC has failed. |
| acSonetPortProtectionTable | 1.3.6.1.4.1.2785.2.3.6.1.1.4 | not-accessible | The SONET/SDH Port Protection table. | |
| acSonetPortProtectionEntry | 1.3.6.1.4.1.2785.2.3.6.1.1.4.1 | not-accessible | An entry in the SONET/SDH Port Protection table. | |
| ACN acSonetPortProtectionNodeId | 1.3.6.1.4.1.2785.2.3.6.1.1.4.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetPortProtectionSlot | 1.3.6.1.4.1.2785.2.3.6.1.1.4.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetPortProtectionPort | 1.3.6.1.4.1.2785.2.3.6.1.1.4.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetPortProtectionType | 1.3.6.1.4.1.2785.2.3.6.1.1.4.1.4 | INTEGER | read-write | This variable statically defines the purpose of the physical port connection as the working or protection port. It does not convey whether the system has undergone a protection switch. |
| acSonetSection | 1.3.6.1.4.1.2785.2.3.6.1.2 | |||
| acSonetSection15MinuteIntervalTable | 1.3.6.1.4.1.2785.2.3.6.1.2.1 | not-accessible | The SONET/SDH Section 15Minute Interval table. | |
| acSonetSection15MinuteIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1 | not-accessible | An entry in the SONET/SDH Section 15Minute Interval table. | |
| ACN acSonetSection15MinuteIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetSection15MinuteIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetSection15MinuteIntervalPort | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetSection15MinuteIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.4 | INTEGER | accessible-for-notify | A number between 1 and 98, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current 15 minute interval. The interval identified by 2 is the most recently completed 15 minute interval. The interval identified by 97 is the oldest 15 minute interval. The interval identified by 98 is a total of the previous 96 stored 15 minute intervals. |
| T/F acSonetSection15MinuteIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.5 | TruthValue | read-only | This flag indicates if the data for this interval is valid. |
| T/F acSonetSection15MinuteIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.6 | TruthValue | read-write | This flag is used to reset the data for a 15 minute interval. |
| I32 acSonetSection15MinuteIntervalStatus | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.7 | Integer32 | read-only | This variable indicates the status of the interface. The acSonetSectionCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The acSonetSectionNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 acSonetSectionNoDefect 2 acSonetSectionLOS 4 acSonetSectionLOF |
| NUM acSonetSection15MinuteIntervalESs | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.8 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours. |
| NUM acSonetSection15MinuteIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours. |
| NUM acSonetSection15MinuteIntervalSEFSs | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours. |
| NUM acSonetSection15MinuteIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.1.2.1.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Section in a particular 15-minute interval in the past 24 hours. |
| acSonetSectionDayIntervalTable | 1.3.6.1.4.1.2785.2.3.6.1.2.2 | not-accessible | The SONET/SDH Section Day Interval table. | |
| acSonetSectionDayIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1 | not-accessible | An entry in the SONET/SDH Section Day Interval table. | |
| ACN acSonetSectionDayIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetSectionDayIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetSectionDayIntervalPort | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetSectionDayIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.4 | INTEGER | accessible-for-notify | A number between 1 and 31, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current day performance monitoring interval. The interval identified by 2 is the most recently completed day interval. The interval identified by 31 is the oldest day interval. |
| T/F acSonetSectionDayIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.5 | TruthValue | read-only | This flag indicates if the data for this interval is valid. |
| T/F acSonetSectionDayIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.6 | TruthValue | read-write | Flag used to reset the current day interval stats. |
| I32 acSonetSectionDayIntervalStatus | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.7 | Integer32 | read-only | This variable indicates the status of the interface. The acSonetSectionCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The acSonetSectionNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 acSonetSectionNoDefect 2 acSonetSectionLOS 4 acSonetSectionLOF |
| NUM acSonetSectionDayIntervalESs | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.8 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Section in a particular day interval in the past 30 days. |
| NUM acSonetSectionDayIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Section in a particular day interval in the past 30 days. |
| NUM acSonetSectionDayIntervalSEFSs | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in a particular day interval in the past 30 days. |
| NUM acSonetSectionDayIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.1.2.2.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Section in a particular day interval in the past 30 days. |
| acSonetSectionThresholdTable | 1.3.6.1.4.1.2785.2.3.6.1.2.3 | not-accessible | The SONET/SDH Section Threshold Table. | |
| acSonetSectionThresholdEntry | 1.3.6.1.4.1.2785.2.3.6.1.2.3.1 | not-accessible | An entry in the SONET/SDH Section Threshold Table. | |
| ACN acSonetSectionThresholdNodeId | 1.3.6.1.4.1.2785.2.3.6.1.2.3.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetSectionThresholdSlot | 1.3.6.1.4.1.2785.2.3.6.1.2.3.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetSectionThresholdPort | 1.3.6.1.4.1.2785.2.3.6.1.2.3.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetSectionThresholdSelectionNum | 1.3.6.1.4.1.2785.2.3.6.1.2.3.1.4 | INTEGER | accessible-for-notify | A number that selects either the 15 thresholds or the day thresholds. |
| ACA acSonetSectionThresholdAdminStatus | 1.3.6.1.4.1.2785.2.3.6.1.2.3.1.5 | AcAdminStatus | read-write | This field is used by the administrator to ensure only one client is performing management operations on this sonet port at a time. When the field is read as available(0), the client can write the value locked(1) into this field to prevent a second client from performing managment ops on this instance. |
| INT acSonetSectionThresholdESs | 1.3.6.1.4.1.2785.2.3.6.1.2.3.1.6 | INTEGER | read-write | The threshold associated with Errored Seconds. |
| INT acSonetSectionThresholdSESs | 1.3.6.1.4.1.2785.2.3.6.1.2.3.1.7 | INTEGER | read-write | The threshold associated with Severely Errored Seconds. |
| INT acSonetSectionThresholdSEFSs | 1.3.6.1.4.1.2785.2.3.6.1.2.3.1.8 | INTEGER | read-write | The threshold associated with Severely Errored Framing Seconds. |
| INT acSonetSectionThresholdCVs | 1.3.6.1.4.1.2785.2.3.6.1.2.3.1.9 | INTEGER | read-write | The threshold associated with Coding Violations. |
| acSonetSectionTIMTable | 1.3.6.1.4.1.2785.2.3.6.1.2.4 | not-accessible | The SONET/SDH Section Trace Identifier Mismatch Table. | |
| acSonetSectionTIMEntry | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1 | not-accessible | An entry in the SONET/SDH Section Trace Identifier Mismatch Table. | |
| ACN acSonetSectionTIMNodeId | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetSectionTIMSlot | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetSectionTIMPort | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| T/F acSonetSectionTIMGenerateEnable | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.4 | TruthValue | read-write | Enables the generation of the Section Trace Identifier. |
| T/F acSonetSectionTIMDetectEnable | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.5 | TruthValue | read-write | Enables the detection of the Section Trace Identifier. |
| STR acSonetSectionTIMTransmitedString | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.6 | AcTraceString | read-write | The string that gets sent to the destination. |
| STR acSonetSectionTIMExpectedString | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.7 | AcTraceString | read-write | The expected string that is to be received. |
| STR acSonetSectionTIMReceivedString | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.8 | AcTraceString | read-only | The contents of the string that is received. |
| T/F acSonetSectionTIMFailure | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.9 | TruthValue | read-only | Failure declared of the Section Trace Identifier. |
| INT acSonetSectionTIMFormat | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.10 | INTEGER | read-write | Format of Path Trace buffer. |
| T/F acSonetSectionTIMMismatchZeros | 1.3.6.1.4.1.2785.2.3.6.1.2.4.1.11 | TruthValue | read-write | Controls whether a received trace message containing all zeros can cause a mismatch defect. |
| acSonetSectionSSMTable | 1.3.6.1.4.1.2785.2.3.6.1.2.5 | not-accessible | The SONET/SDH Section Synchronization Status Message Table. | |
| acSonetSectionSSMEntry | 1.3.6.1.4.1.2785.2.3.6.1.2.5.1 | not-accessible | An entry in the SONET/SDH Section Synchronization Status Message Table. | |
| ACN acSonetSectionSSMNodeId | 1.3.6.1.4.1.2785.2.3.6.1.2.5.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetSectionSSMSlot | 1.3.6.1.4.1.2785.2.3.6.1.2.5.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetSectionSSMPort | 1.3.6.1.4.1.2785.2.3.6.1.2.5.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| T/F acSonetSectionSSMDetectEnable | 1.3.6.1.4.1.2785.2.3.6.1.2.5.1.4 | TruthValue | read-write | Enables the detection of the Synchronization Status Message. |
| INT acSonetSectionSSMTransmitedValue | 1.3.6.1.4.1.2785.2.3.6.1.2.5.1.5 | INTEGER | read-only | The S1 byte value that gets sent to the destination. |
| INT acSonetSectionSSMReceivedValue | 1.3.6.1.4.1.2785.2.3.6.1.2.5.1.6 | INTEGER | read-only | The S1 byte value that is received. |
| acSonetLine | 1.3.6.1.4.1.2785.2.3.6.1.3 | |||
| acSonetLine15MinuteIntervalTable | 1.3.6.1.4.1.2785.2.3.6.1.3.1 | not-accessible | The SONET/SDH Line 15Minute Interval Table. | |
| acSonetLine15MinuteIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1 | not-accessible | An entry in the SONET/SDH Line 15Minute Interval table. | |
| ACN acSonetLine15MinuteIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetLine15MinuteIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetLine15MinuteIntervalPort | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetLine15MinuteIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.4 | INTEGER | accessible-for-notify | A number between 1 and 98, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current 15 minute interval. The interval identified by 2 is the most recently completed 15 minute interval. The interval identified by 97 is the oldest 15 minute interval. The interval identified by 98 is a total of the previous 96 stored 15 minute intervals. |
| T/F acSonetLine15MinuteIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.5 | TruthValue | read-only | This variable indicates if the data for this interval is valid. |
| T/F acSonetLine15MinuteIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.6 | TruthValue | read-write | Flag to reset the 15 minute SONET Line interval statistics. |
| I32 acSonetLine15MinuteIntervalStatus | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.7 | Integer32 | read-only | This variable indicates the status of the interface. The acSonetLineCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The acSonetLineNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 acSonetLineNoDefect 2 acSonetLineAIS 4 acSonetLineRDI |
| NUM acSonetLine15MinuteIntervalESs | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.8 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours. |
| NUM acSonetLine15MinuteIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours. |
| NUM acSonetLine15MinuteIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours. |
| NUM acSonetLine15MinuteIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours. |
| NUM acSonetLine15MinuteIntervalBER | 1.3.6.1.4.1.2785.2.3.6.1.3.1.1.12 | PerfIntervalCount | read-only | The counter associated with the max BER encountered by a SONET/SDH Line in a particular 15-minute interval in the past 24 hours. |
| acSonetLineDayIntervalTable | 1.3.6.1.4.1.2785.2.3.6.1.3.2 | not-accessible | The SONET/SDH Line Day Interval Table. | |
| acSonetLineDayIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1 | not-accessible | An entry in the SONET/SDH Line Day Interval table. | |
| ACN acSonetLineDayIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetLineDayIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetLineDayIntervalPort | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetLineDayIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.4 | INTEGER | accessible-for-notify | A number between 1 and 31, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current day performance monitoring interval. The interval identified by 2 is the most recently completed day interval. The interval identified by 31 is the oldest day interval. |
| T/F acSonetLineDayIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.5 | TruthValue | read-only | This variable indicates if the data for this interval is valid. |
| T/F acSonetLineDayIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.6 | TruthValue | read-write | Flag to reset the SONET Line Day interval statistics. |
| I32 acSonetLineDayIntervalStatus | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.7 | Integer32 | read-only | This variable indicates the status of the interface. The acSonetLineCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The acSonetLineNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 acSonetLineNoDefect 2 acSonetLineAIS 4 acSonetLineRDI |
| NUM acSonetLineDayIntervalESs | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.8 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Line in a particular day interval in the past 30 days. |
| NUM acSonetLineDayIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in a particular day interval in the past 30 days. |
| NUM acSonetLineDayIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Line in a particular day interval in the past 30 days. |
| NUM acSonetLineDayIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Line in a particular day interval in the past 30 days. |
| NUM acSonetLineDayIntervalBER | 1.3.6.1.4.1.2785.2.3.6.1.3.2.1.12 | PerfIntervalCount | read-only | The counter associated with the max BER encountered by a SONET/SDH Line in a particular day interval in the past 30 days. |
| acSonetLineThresholdTable | 1.3.6.1.4.1.2785.2.3.6.1.3.3 | not-accessible | The SONET/SDH Line Threshold Table. | |
| acSonetLineThresholdEntry | 1.3.6.1.4.1.2785.2.3.6.1.3.3.1 | not-accessible | An entry in the SONET/SDH Line Threshold Table. | |
| ACN acSonetLineThresholdNodeId | 1.3.6.1.4.1.2785.2.3.6.1.3.3.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetLineThresholdSlot | 1.3.6.1.4.1.2785.2.3.6.1.3.3.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetLineThresholdPort | 1.3.6.1.4.1.2785.2.3.6.1.3.3.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetLineThresholdSelectionNum | 1.3.6.1.4.1.2785.2.3.6.1.3.3.1.4 | INTEGER | accessible-for-notify | A number that selects either the 15 thresholds or the day thresholds. |
| ACA acSonetLineThresholdAdminStatus | 1.3.6.1.4.1.2785.2.3.6.1.3.3.1.5 | AcAdminStatus | read-write | This field is used by the administrator to ensure only one client is performing management operations on this serial port at a time. When the field is read as available(0), the client can write the value locked(1) into this field to prevent a second client from performing managment ops on this instance. |
| INT acSonetLineThresholdESs | 1.3.6.1.4.1.2785.2.3.6.1.3.3.1.6 | INTEGER | read-write | The threshold associated with Errored Seconds. |
| INT acSonetLineThresholdSESs | 1.3.6.1.4.1.2785.2.3.6.1.3.3.1.7 | INTEGER | read-write | The threshold associated with Severely Errored Seconds. |
| INT acSonetLineThresholdCVs | 1.3.6.1.4.1.2785.2.3.6.1.3.3.1.8 | INTEGER | read-write | The threshold associated with Coding Violations. |
| INT acSonetLineThresholdUASs | 1.3.6.1.4.1.2785.2.3.6.1.3.3.1.9 | INTEGER | read-write | The threshold associated with Unavailable Secondss. |
| acSonetLineProtectionTable | 1.3.6.1.4.1.2785.2.3.6.1.3.4 | not-accessible | The SONET/SDH Line Protection table. | |
| acSonetLineProtectionEntry | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1 | not-accessible | An entry in the SONET/SDH Line Protection table. | |
| ACN acSonetLineProtectionNodeId | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetLineProtectionSlot | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetLineProtectionPort | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetLineProtectionArchitecture | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.4 | INTEGER | read-write | This variable defines the APS architecture as either 1+1 or 1:1. |
| INT acSonetLineProtectionOpMode | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.5 | INTEGER | read-write | This variable defines the APS mode as either unidirectional or bidirectional. |
| INT acSonetLineProtectionSwitchType | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.6 | INTEGER | read-write | This variable defines the APS switch type as either revertive or nonrevertive. |
| I32 acSonetLineProtectionSFThreshold | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.7 | Integer32 | read-write | The threshold associated with Signal Fail (SF). This value determines the BER level for protection switching. |
| I32 acSonetLineProtectionSDThreshold | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.8 | Integer32 | read-write | The threshold associated with Signal Degrade (SD). This value determines the BER level for protection switching. |
| T/F acSonetLineProtectionActiveTraffic | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.9 | TruthValue | read-only | This variable indicates when active traffic is on this line. |
| T/F acSonetLineProtectionProtectionSwitch | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.10 | TruthValue | read-only | This variable indicates when a protection switch is currently affecting this line. |
| T/F acSonetLineProtectionFail | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.11 | TruthValue | read-only | This variable indicates when a protection switching failure has taken place. See GR-253, 6.2.1.1.6. |
| T/F acSonetLineProtectionChannelMismatchFail | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.12 | TruthValue | read-only | This variable indicates when a protection switching channel mismatch failure has taken place. See GR-253, 6.2.1.1.6. |
| T/F acSonetLineProtectionModeMismatchFail | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.13 | TruthValue | read-only | This variable indicates when a protection switching mode mismatch failure has taken place. See GR-253, 6.2.1.1.6. |
| T/F acSonetLineProtectionFarEndLineFail | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.14 | TruthValue | read-only | This variable indicates when a protection switching far-end protection-line failure has taken place. See GR-253, 6.2.1.1.6. |
| I32 acSonetLineProtectionWTRTime | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.15 | Integer32 | read-write | This variable defines the APS Wait To Restore time. The time has one second granularity and may have a value in the range from 300 seconds (5 minutes) to 720 seconds (12 minutes). |
| INT acSonetLineProtectionManCommand | 1.3.6.1.4.1.2785.2.3.6.1.3.4.1.16 | INTEGER | read-write | This variable defines the APS manually initiated commands. |
| acSonetFarEndLine | 1.3.6.1.4.1.2785.2.3.6.1.4 | |||
| acSonetFarEndLine15MinuteIntervalTable | 1.3.6.1.4.1.2785.2.3.6.1.4.1 | not-accessible | The SONET/SDH FarEndLine 15Minute Interval Table. | |
| acSonetFarEndLine15MinuteIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1 | not-accessible | An entry in the SONET/SDH FarEndLine 15Minute Interval table. | |
| ACN acSonetFarEndLine15MinuteIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetFarEndLine15MinuteIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetFarEndLine15MinuteIntervalPort | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetFarEndLine15MinuteIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1.4 | INTEGER | accessible-for-notify | A number between 1 and 98, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current 15 minute interval. The interval identified by 2 is the most recently completed 15 minute interval. The interval identified by 97 is the oldest 15 minute interval. The interval identified by 98 is a total of the previous 96 stored 15 minute intervals. |
| T/F acSonetFarEndLine15MinuteIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1.5 | TruthValue | read-only | This variable indicates if the data for this interval is valid. |
| T/F acSonetFarEndLine15MinuteIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1.6 | TruthValue | read-write | Flag to reset the SONET Far End Line 15 minute interval statistics. |
| NUM acSonetFarEndLine15MinuteIntervalESs | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1.7 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH FarEndLine in a particular 15-minute interval in the past 24 hours. |
| NUM acSonetFarEndLine15MinuteIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1.8 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH FarEndLine in a particular 15-minute interval in the past 24 hours. |
| NUM acSonetFarEndLine15MinuteIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH FarEndLine in a particular 15-minute interval in the past 24 hours. |
| NUM acSonetFarEndLine15MinuteIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.1.4.1.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH FarEndLine in a particular 15-minute interval in the past 24 hours. |
| acSonetFarEndLineDayIntervalTable | 1.3.6.1.4.1.2785.2.3.6.1.4.2 | not-accessible | The SONET/SDH FarEndLine Day Interval Table. | |
| acSonetFarEndLineDayIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1 | not-accessible | An entry in the SONET/SDH FarEndLine Day Interval table. | |
| ACN acSonetFarEndLineDayIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetFarEndLineDayIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetFarEndLineDayIntervalPort | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetFarEndLineDayIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1.4 | INTEGER | accessible-for-notify | A number between 1 and 31, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current day performance monitoring interval. The interval identified by 2 is the most recently completed day interval. The interval identified by 31 is the oldest day interval. |
| T/F acSonetFarEndLineDayIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1.5 | TruthValue | read-only | This variable indicates if the data for this interval is valid. |
| T/F acSonetFarEndLineDayIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1.6 | TruthValue | read-write | Flag to reset the SONET far end line day interval statistics. |
| NUM acSonetFarEndLineDayIntervalESs | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1.7 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH FarEndLine in a particular day interval in the past 30 days. |
| NUM acSonetFarEndLineDayIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1.8 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH FarEndLine in a particular day interval in the past 30 days. |
| NUM acSonetFarEndLineDayIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH FarEndLine in a particular day interval in the past 30 days. |
| NUM acSonetFarEndLineDayIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.1.4.2.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH FarEndLine in a particular day interval in the past 30 days. |
| acSonetFarEndLineThresholdTable | 1.3.6.1.4.1.2785.2.3.6.1.4.3 | not-accessible | The SONET/SDH FarEndLine Threshold Table. | |
| acSonetFarEndLineThresholdEntry | 1.3.6.1.4.1.2785.2.3.6.1.4.3.1 | not-accessible | An entry in the SONET/SDH FarEndLine Threshold Table. | |
| ACN acSonetFarEndLineThresholdNodeId | 1.3.6.1.4.1.2785.2.3.6.1.4.3.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetFarEndLineThresholdSlot | 1.3.6.1.4.1.2785.2.3.6.1.4.3.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetFarEndLineThresholdPort | 1.3.6.1.4.1.2785.2.3.6.1.4.3.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetFarEndLineThresholdSelectionNum | 1.3.6.1.4.1.2785.2.3.6.1.4.3.1.4 | INTEGER | accessible-for-notify | A number that selects either the 15 thresholds or the day thresholds. |
| ACA acSonetFarEndLineThresholdAdminStatus | 1.3.6.1.4.1.2785.2.3.6.1.4.3.1.5 | AcAdminStatus | read-write | This field is used by the administrator to ensure only one client is performing management operations on this serial port at a time. When the field is read as available(0), the client can write the value locked(1) into this field to prevent a second client from performing managment ops on this instance. |
| INT acSonetFarEndLineThresholdESs | 1.3.6.1.4.1.2785.2.3.6.1.4.3.1.6 | INTEGER | read-write | The threshold associated with Errored Seconds. |
| INT acSonetFarEndLineThresholdSESs | 1.3.6.1.4.1.2785.2.3.6.1.4.3.1.7 | INTEGER | read-write | The threshold associated with Severely Errored Seconds. |
| INT acSonetFarEndLineThresholdCVs | 1.3.6.1.4.1.2785.2.3.6.1.4.3.1.8 | INTEGER | read-write | The threshold associated with Coding Violations. |
| INT acSonetFarEndLineThresholdUASs | 1.3.6.1.4.1.2785.2.3.6.1.4.3.1.9 | INTEGER | read-write | The threshold associated with Unavailable Secondss. |
| acSonetObjectsPath | 1.3.6.1.4.1.2785.2.3.6.2 | |||
| acSonetPath | 1.3.6.1.4.1.2785.2.3.6.2.1 | |||
| acSonetPath15MinuteIntervalTable | 1.3.6.1.4.1.2785.2.3.6.2.1.1 | not-accessible | The SONET/SDH Path 15Minute Interval table. | |
| acSonetPath15MinuteIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1 | not-accessible | An entry in the SONET/SDH Path 15Minute Interval table. | |
| ACN acSonetPath15MinuteIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetPath15MinuteIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetPath15MinuteIntervalPort | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetPath15MinuteIntervalPath | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.4 | INTEGER | accessible-for-notify | The STS Path for which the set of statistics is available. |
| INT acSonetPath15MinuteIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.5 | INTEGER | accessible-for-notify | A number between 1 and 98, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current 15 minute interval. The interval identified by 2 is the most recently completed 15 minute interval. The interval identified by 97 is the oldest 15 minute interval. The interval identified by 98 is a total of the previous 96 stored 15 minute intervals. |
| I32 acSonetPath15MinuteIntervalStatus | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.6 | Integer32 | read-only | This variable indicates the status of the interface. The acSonetPathCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The acSonetPathNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 acSonetPathNoDefect 2 acSonetPathSTSLOP 4 acSonetPathSTSAIS 8 acSonetPathSTSRDI 16 acSonetPathUnequipped 32 acSonetPathPayloadLabelMismatch |
| T/F acSonetPath15MinuteIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.7 | TruthValue | read-only | This variable indicates if the data for this interval is valid. |
| T/F acSonetPath15MinuteIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.8 | TruthValue | read-write | This flag is used to reset the data for a 15 minute interval. |
| NUM acSonetPath15MinuteIntervalESs | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Path in the current 15 minute interval. |
| NUM acSonetPath15MinuteIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Path in the current 15 minute interval. |
| NUM acSonetPath15MinuteIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Path in the current 15 minute interval. |
| NUM acSonetPath15MinuteIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.12 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a Path in the current 15 minute interval. |
| NUM acSonetPath15MinuteIntervalBER | 1.3.6.1.4.1.2785.2.3.6.2.1.1.1.13 | PerfIntervalCount | read-only | The counter associated with the BER encountered by a Path in the current 15 minute interval. Represents the max value for an interval for number > 1. |
| acSonetPathDayIntervalTable | 1.3.6.1.4.1.2785.2.3.6.2.1.2 | not-accessible | The SONET/SDH Path Day Interval table. | |
| acSonetPathDayIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1 | not-accessible | An entry in the SONET/SDH Path Day Interval table. | |
| ACN acSonetPathDayIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetPathDayIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetPathDayIntervalPort | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetPathDayIntervalPath | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.4 | INTEGER | accessible-for-notify | The STS Path for which the set of statistics is available. |
| INT acSonetPathDayIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.5 | INTEGER | accessible-for-notify | A number between 1 and 31, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current day performance monitoring interval. The interval identified by 2 is the most recently completed day interval. The interval identified by 31 is the oldest day interval. |
| I32 acSonetPathDayIntervalStatus | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.6 | Integer32 | read-only | This variable indicates the status of the interface. The acSonetPathCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The acSonetPathNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 acSonetPathNoDefect 2 acSonetPathSTSLOP 4 acSonetPathSTSAIS 8 acSonetPathSTSRDI 16 acSonetPathUnequipped 32 acSonetPathPayloadLabelMismatch |
| T/F acSonetPathDayIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.7 | TruthValue | read-only | This variable indicates if the data for this day is valid. |
| T/F acSonetPathDayIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.8 | TruthValue | read-write | This flag is used to reset the data for day interval. |
| NUM acSonetPathDayIntervalESs | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH Path in the past day interval. |
| NUM acSonetPathDayIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Path in the past day interval. |
| NUM acSonetPathDayIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH Path in the past day interval. |
| NUM acSonetPathDayIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.12 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a Path in the past day interval. |
| NUM acSonetPathDayIntervalBER | 1.3.6.1.4.1.2785.2.3.6.2.1.2.1.13 | PerfIntervalCount | read-only | The counter associated with the BER encountered by a Path in the past day interval. |
| acSonetPathThresholdTable | 1.3.6.1.4.1.2785.2.3.6.2.1.3 | not-accessible | The SONET/SDH Path Threshold Table. | |
| acSonetPathThresholdEntry | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1 | not-accessible | An entry in the SONET/SDH Path Threshold Table. | |
| ACN acSonetPathThresholdNodeId | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetPathThresholdSlot | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetPathThresholdPort | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetPathThresholdPath | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1.4 | INTEGER | accessible-for-notify | The STS Path for which the set of statistics is available. |
| INT acSonetPathThresholdSelectionNum | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1.5 | INTEGER | accessible-for-notify | A number that selects either the 15 thresholds or the day thresholds. |
| ACA acSonetPathThresholdAdminStatus | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1.6 | AcAdminStatus | read-write | This field is used by the administrator to ensure only one client is performing management operations on this serial port at a time. When the field is read as available(0), the client can write the value locked(1) into this field to prevent a second client from performing managment ops on this instance. |
| INT acSonetPathThresholdESs | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1.7 | INTEGER | read-write | The threshold associated with Errored Seconds. |
| INT acSonetPathThresholdSESs | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1.8 | INTEGER | read-write | The threshold associated with Severely Errored Seconds. |
| INT acSonetPathThresholdCVs | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1.9 | INTEGER | read-write | The threshold associated with Coding Violations. |
| INT acSonetPathThresholdUASs | 1.3.6.1.4.1.2785.2.3.6.2.1.3.1.10 | INTEGER | read-write | The threshold associated with Unavailable Seconds. |
| acSonetPathRDITable | 1.3.6.1.4.1.2785.2.3.6.2.1.4 | not-accessible | The SONET/SDH Path RDI Table. | |
| acSonetPathRDIEntry | 1.3.6.1.4.1.2785.2.3.6.2.1.4.1 | not-accessible | An entry in the SONET/SDH Path RDI Table. | |
| ACN acSonetPathRDINodeId | 1.3.6.1.4.1.2785.2.3.6.2.1.4.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetPathRDISlot | 1.3.6.1.4.1.2785.2.3.6.2.1.4.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetPathRDIPort | 1.3.6.1.4.1.2785.2.3.6.2.1.4.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetPathRDIPath | 1.3.6.1.4.1.2785.2.3.6.2.1.4.1.4 | INTEGER | accessible-for-notify | The STS path instance for this port |
| INT acSonetPathRDIOpMode | 1.3.6.1.4.1.2785.2.3.6.2.1.4.1.5 | INTEGER | read-write | The Remote Defect Indiction signals have undergone a number of changes over the years, and now encompass two or even three different versions. See GR-253 6.2.1.3.2 for more information. |
| acSonetPathTIMTable | 1.3.6.1.4.1.2785.2.3.6.2.1.5 | not-accessible | The SONET/SDH Path Trace Identifier Mismatch Table. | |
| acSonetPathTIMEntry | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1 | not-accessible | An entry in the SONET/SDH Path Trace Identifier Mismatch Table. | |
| ACN acSonetPathTIMNodeId | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetPathTIMSlot | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetPathTIMPort | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetPathTIMPath | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.4 | INTEGER | accessible-for-notify | The path instance of the port. |
| T/F acSonetPathTIMGenerateEnable | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.5 | TruthValue | read-write | Enables the generation of the Path Trace Identifier. |
| T/F acSonetPathTIMDetectEnable | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.6 | TruthValue | read-write | Enables the detection of the Path Trace Identifier. |
| STR acSonetPathTIMTransmitedString | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.7 | AcTraceString | read-write | The string that gets sent to the destination. |
| STR acSonetPathTIMExpectedString | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.8 | AcTraceString | read-write | The expected string that is to be received. |
| STR acSonetPathTIMReceivedString | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.9 | AcTraceString | read-only | The contents of the string that is received. |
| T/F acSonetPathTIMFailure | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.10 | TruthValue | read-only | Failure declared of the Path Trace Identifier. |
| INT acSonetPathTIMFormat | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.11 | INTEGER | read-write | Format of Path Trace buffer. |
| T/F acSonetPathTIMMismatchZeros | 1.3.6.1.4.1.2785.2.3.6.2.1.5.1.12 | TruthValue | read-write | Controls whether a received trace message containing all zeros can cause a mismatch defect. |
| acSonetPathPLMTable | 1.3.6.1.4.1.2785.2.3.6.2.1.6 | not-accessible | The SONET/SDH Path Payload Label Mismatch Table. | |
| acSonetPathPLMEntry | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1 | not-accessible | An entry in the SONET/SDH Path Payload Label Mismatch Table. | |
| ACN acSonetPathPLMNodeId | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetPathPLMSlot | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetPathPLMPort | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetPathPLMPath | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1.4 | INTEGER | accessible-for-notify | The path instance of the port. |
| T/F acSonetPathPLMDetectEnable | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1.5 | TruthValue | read-write | Enables the detection of the Path Payload Label. |
| INT acSonetPathPLMTransmitedValue | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1.6 | INTEGER | read-write | The Path Payload Label that gets sent to the destination. See GR-253 Tables 3-2, 3-3. |
| INT acSonetPathPLMExpectedValue | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1.7 | INTEGER | read-write | The expected Path Payload Label that is to be received. See GR-253 Tables 3-2, 3-3. |
| INT acSonetPathPLMReceivedValue | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1.8 | INTEGER | read-only | The contents of the Path Payload Label that is received. See GR-253 Tables 3-2, 3-3. |
| T/F acSonetPathPLMMismatchFailure | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1.9 | TruthValue | read-only | Mismatch failure declared for the Path Payload Label. |
| T/F acSonetPathPLMUnequipped | 1.3.6.1.4.1.2785.2.3.6.2.1.6.1.10 | TruthValue | read-only | Unequipped failure declared for the Path Payload Label. |
| acSonetPathProtectionTable | 1.3.6.1.4.1.2785.2.3.6.2.1.7 | not-accessible | The SONET/SDH Path Protection table. | |
| acSonetPathProtectionEntry | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1 | not-accessible | An entry in the SONET/SDH Path Protection table. | |
| ACN acSonetPathProtectionNodeId | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetPathProtectionSlot | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetPathProtectionPort | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetPathProtectionPath | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.4 | INTEGER | accessible-for-notify | The STS-1 path for the port. |
| INT acSonetPathProtectionSwitchType | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.5 | INTEGER | read-write | This variable defines the path switch type as either revertive or nonrevertive. |
| I32 acSonetPathProtectionSFThreshold | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.6 | Integer32 | read-write | The threshold associated with Signal Fail (SF). This value determines the BER level for protection switching. The value used is the exponent to a power of 10, so 3 means 10E-3. |
| I32 acSonetPathProtectionSDThreshold | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.7 | Integer32 | read-write | The threshold associated with Signal Degrade (SD). This value determines the BER level for protection switching. The value used is the exponent to a power of 10, so 6 means 10E-6. |
| T/F acSonetPathProtectionActiveTraffic | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.8 | TruthValue | read-only | This variable indicates when ODP or UPSR active traffic is on this path. |
| T/F acSonetPathProtectionProtectionSwitch | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.9 | TruthValue | read-only | This variable indicates when either a UPSR or an ODP protection switch is currently affecting this path. |
| I32 acSonetPathProtectionWTRTime | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.10 | Integer32 | read-write | This variable defines the ODP or UPSR Wait To Restore time. The time has one second granularity and may have a value in the range from 1 second to 720 seconds(12 minutes). |
| I32 acSonetPathProtectionWTITime | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.11 | Integer32 | read-write | This variable defines the ODP Wait To Idle time. The time has one second granularity and may have a value in the range from 1 to 50 seconds. |
| I32 acSonetPathProtectionWTCTime | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.12 | Integer32 | read-write | This variable defines the ODP Wait To Clear time. The time has one second granularity and may have a value in the range from 1 second to 720 seconds (12 minutes). |
| I32 acSonetPathProtectionWTRelTime | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.13 | Integer32 | read-write | This variable defines the ODP Wait To Release time. The time has one second granularity and may have a value in the range from 1 to 50 seconds. |
| INT acSonetPathProtectionManSwitch | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.14 | INTEGER | read-write | This variable defines the ODP and UPSR manually initiated commands. Entries 7..10 are used in ODP only. |
| INT acSonetPathProtectionSwitchOpStatus | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.15 | INTEGER | read-only | This variable defines the current switch condition of an ODP path. |
| INT acSonetPathProtectionProtectionMode | 1.3.6.1.4.1.2785.2.3.6.2.1.7.1.16 | INTEGER | read-write | !! This object *MUST* be set before any other object is accessed. !! This is the type of protection switching to be used if independent path level protection switching is enabled. This is similar to the acTimeSlotPathProtectionMode object that resides in the timeslot table. Refer to it for a description of the enumerations. |
| acSonetFarEndPath | 1.3.6.1.4.1.2785.2.3.6.2.2 | |||
| acSonetFarEndPath15MinuteIntervalTable | 1.3.6.1.4.1.2785.2.3.6.2.2.1 | not-accessible | The SONET/SDH FarEndPath 15Minute Interval table. | |
| acSonetFarEndPath15MinuteIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1 | not-accessible | An entry in the SONET/SDH FarEndPath 15Minute Interval table. | |
| ACN acSonetFarEndPath15MinuteIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetFarEndPath15MinuteIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetFarEndPath15MinuteIntervalPort | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetFarEndPath15MinuteIntervalPath | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.4 | INTEGER | accessible-for-notify | The STS Path for which the set of statistics is available. |
| INT acSonetFarEndPath15MinuteIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.5 | INTEGER | accessible-for-notify | A number between 1 and 98, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current 15 minute interval. The interval identified by 2 is the most recently completed 15 minute interval. The interval identified by 97 is the oldest 15 minute interval. The interval identified by 98 is a total of the previous 96 stored 15 minute intervals. |
| T/F acSonetFarEndPath15MinuteIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.6 | TruthValue | read-only | This variable indicates if the data for this far end 15 minute interval is valid. |
| T/F acSonetFarEndPath15MinuteIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.7 | TruthValue | read-write | This flag is used to reset the data for far end 15 minute interval. |
| NUM acSonetFarEndPath15MinuteIntervalESs | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.8 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH FarEndPath in the current 15 minute interval. |
| NUM acSonetFarEndPath15MinuteIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH FarEndPath in the current 15 minute interval. |
| NUM acSonetFarEndPath15MinuteIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH FarEndPath in the current 15 minute interval. |
| NUM acSonetFarEndPath15MinuteIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.2.2.1.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a FarEndPath in the current 15 minute interval. |
| acSonetFarEndPathDayIntervalTable | 1.3.6.1.4.1.2785.2.3.6.2.2.2 | not-accessible | The SONET/SDH FarEndPath Day Interval table. | |
| acSonetFarEndPathDayIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1 | not-accessible | An entry in the SONET/SDH FarEndPath Day Interval table. | |
| ACN acSonetFarEndPathDayIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetFarEndPathDayIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetFarEndPathDayIntervalPort | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetFarEndPathDayIntervalPath | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.4 | INTEGER | accessible-for-notify | The STS Path for which the set of statistics is available. |
| INT acSonetFarEndPathDayIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.5 | INTEGER | accessible-for-notify | A number between 1 and 31, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current day performance monitoring interval. The interval identified by 2 is the most recently completed day interval. The interval identified by 31 is the oldest day interval. |
| T/F acSonetFarEndPathDayIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.6 | TruthValue | read-only | This variable indicates if the data for this far end day interval is valid. |
| T/F acSonetFarEndPathDayIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.7 | TruthValue | read-write | This flag is used to reset the data for far end day interval. |
| NUM acSonetFarEndPathDayIntervalESs | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.8 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH FarEndPath in the current 15 minute interval. |
| NUM acSonetFarEndPathDayIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH FarEndPath in the current 15 minute interval. |
| NUM acSonetFarEndPathDayIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH FarEndPath in the current 15 minute interval. |
| NUM acSonetFarEndPathDayIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.2.2.2.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a FarEndPath in the current 15 minute interval. |
| acSonetFarEndPathThresholdTable | 1.3.6.1.4.1.2785.2.3.6.2.2.3 | not-accessible | The SONET/SDH FarEndPath Threshold Table. | |
| acSonetFarEndPathThresholdEntry | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1 | not-accessible | An entry in the SONET/SDH FarEndPath Threshold Table. | |
| ACN acSonetFarEndPathThresholdNodeId | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetFarEndPathThresholdSlot | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetFarEndPathThresholdPort | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetFarEndPathThresholdPath | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1.4 | INTEGER | accessible-for-notify | The STS Path for which the set of statistics is available. |
| INT acSonetFarEndPathThresholdSelectionNum | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1.5 | INTEGER | accessible-for-notify | A number that selects either the 15 thresholds or the day thresholds. |
| ACA acSonetFarEndPathThresholdAdminStatus | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1.6 | AcAdminStatus | read-write | This field is used by the administrator to ensure only one client is performing management operations on this serial port at a time. When the field is read as available(0), the client can write the value locked(1) into this field to prevent a second client from performing managment ops on this instance. |
| INT acSonetFarEndPathThresholdESs | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1.7 | INTEGER | read-write | The threshold associated with Errored Seconds. |
| INT acSonetFarEndPathThresholdSESs | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1.8 | INTEGER | read-write | The threshold associated with Severely Errored Seconds. |
| INT acSonetFarEndPathThresholdCVs | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1.9 | INTEGER | read-write | The threshold associated with Coding Violations. |
| INT acSonetFarEndPathThresholdUASs | 1.3.6.1.4.1.2785.2.3.6.2.2.3.1.10 | INTEGER | read-write | The threshold associated with Unavailable Secondss. |
| acSonetObjectsVT | 1.3.6.1.4.1.2785.2.3.6.3 | |||
| acSonetVT | 1.3.6.1.4.1.2785.2.3.6.3.1 | |||
| acSonetVT15MinuteIntervalTable | 1.3.6.1.4.1.2785.2.3.6.3.1.1 | not-accessible | The SONET/SDH VT 15Minute Interval table. | |
| acSonetVT15MinuteIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1 | not-accessible | An entry in the SONET/SDH VT 15Minute Interval table. | |
| ACN acSonetVT15MinuteIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetVT15MinuteIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetVT15MinuteIntervalPort | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetVT15MinuteIntervalVT | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.4 | INTEGER | accessible-for-notify | The VT for which the set of statistics is available. |
| INT acSonetVT15MinuteIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.5 | INTEGER | accessible-for-notify | A number between 1 and 98, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current 15 minute interval. The interval identified by 2 is the most recently completed 15 minute interval. The interval identified by 97 is the oldest 15 minute interval. The interval identified by 98 is a total of the previous 96 stored 15 minute intervals. |
| I32 acSonetVT15MinuteIntervalStatus | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.7 | Integer32 | read-only | This variable indicates the status of the interface. The acSonetVTCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects and failures simultaneously. The acSonetVTNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 acSonetVTNoDefect 2 acSonetVTLOP 4 acSonetVTPathAIS 8 acSonetVTPathRDI 16 acSonetVTPathRFI 32 acSonetVTUnequipped 64 acSonetVTPayloadLabelMismatch |
| T/F acSonetVT15MinuteIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.8 | TruthValue | read-only | This variable indicates if the data for this VT 15 minute interval is valid. |
| T/F acSonetVT15MinuteIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.9 | TruthValue | read-write | This flag is used to reset the data for this VT 15 minute interval. |
| NUM acSonetVT15MinuteIntervalESs | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH VT in the current 15 minute interval. |
| NUM acSonetVT15MinuteIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH VT in the current 15 minute interval. |
| NUM acSonetVT15MinuteIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.12 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH VT in the current 15 minute interval. |
| NUM acSonetVT15MinuteIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.13 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a VT in the current 15 minute interval. |
| NUM acSonetVT15MinuteIntervalBER | 1.3.6.1.4.1.2785.2.3.6.3.1.1.1.14 | PerfIntervalCount | read-only | The counter associated with the BER encountered by a VT in the current 15 minute interval. Represents the max BER for the interval when number > 1. |
| acSonetVTDayIntervalTable | 1.3.6.1.4.1.2785.2.3.6.3.1.2 | not-accessible | The SONET/SDH VT Day Interval table. | |
| acSonetVTDayIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1 | not-accessible | An entry in the SONET/SDH VT Day Interval table. | |
| ACN acSonetVTDayIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetVTDayIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetVTDayIntervalPort | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetVTDayIntervalVT | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.4 | INTEGER | accessible-for-notify | The VT for which the set of statistics is available. |
| INT acSonetVTDayIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.5 | INTEGER | accessible-for-notify | A number between 1 and 31, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current day performance monitoring interval. The interval identified by 2 is the most recently completed day interval. The interval identified by 31 is the oldest day interval. |
| I32 acSonetVTDayIntervalStatus | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.6 | Integer32 | read-only | This variable indicates the status of the interface. The acSonetVTCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects and failures simultaneously. The acSonetVTNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 acSonetVTNoDefect 2 acSonetVTLOP 4 acSonetVTPathAIS 8 acSonetVTPathRDI 16 acSonetVTPathRFI 32 acSonetVTUnequipped 64 acSonetVTPayloadLabelMismatch |
| T/F acSonetVTDayIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.7 | TruthValue | read-only | This variable indicates if the data for this VT Day interval is valid. |
| T/F acSonetVTDayIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.8 | TruthValue | read-write | This flag is used to reset the data for this VT Day interval. |
| NUM acSonetVTDayIntervalESs | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH VT in the last day interval. |
| NUM acSonetVTDayIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH VT in the last day interval. |
| NUM acSonetVTDayIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH VT in the last day interval. |
| NUM acSonetVTDayIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.12 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a VT in the last day interval. |
| NUM acSonetVTDayIntervalBER | 1.3.6.1.4.1.2785.2.3.6.3.1.2.1.13 | PerfIntervalCount | read-only | The counter associated with the max BER encountered by a VT in a day. |
| acSonetVTThresholdTable | 1.3.6.1.4.1.2785.2.3.6.3.1.3 | not-accessible | The SONET/SDH VT Threshold Table. | |
| acSonetVTThresholdEntry | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1 | not-accessible | An entry in the SONET/SDH VT Threshold Table. | |
| ACN acSonetVTThresholdNodeId | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetVTThresholdSlot | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetVTThresholdPort | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetVTThresholdVT | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1.4 | INTEGER | accessible-for-notify | The VT for which the set of statistics is available. |
| INT acSonetVTThresholdSelectionNum | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1.5 | INTEGER | accessible-for-notify | A number that selects either the 15 thresholds or the day thresholds. |
| ACA acSonetVTThresholdAdminStatus | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1.6 | AcAdminStatus | read-write | This field is used by the administrator to ensure only one client is performing management operations on this serial port at a time. When the field is read as available(0), the client can write the value locked(1) into this field to prevent a second client from performing managment ops on this instance. |
| INT acSonetVTThresholdESs | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1.7 | INTEGER | read-write | The threshold associated with Errored Seconds. |
| INT acSonetVTThresholdSESs | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1.8 | INTEGER | read-write | The threshold associated with Severely Errored Seconds. |
| INT acSonetVTThresholdCVs | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1.9 | INTEGER | read-write | The threshold associated with Coding Violations. |
| INT acSonetVTThresholdUASs | 1.3.6.1.4.1.2785.2.3.6.3.1.3.1.10 | INTEGER | read-write | The threshold associated with Unavailable Secondss. |
| acSonetVTRDITable | 1.3.6.1.4.1.2785.2.3.6.3.1.4 | not-accessible | The SONET/SDH VT RDI Table. | |
| acSonetVTRDIEntry | 1.3.6.1.4.1.2785.2.3.6.3.1.4.1 | not-accessible | An entry in the SONET/SDH VT RDI Table. | |
| ACN acSonetVTRDINodeId | 1.3.6.1.4.1.2785.2.3.6.3.1.4.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetVTRDISlot | 1.3.6.1.4.1.2785.2.3.6.3.1.4.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetVTRDIPort | 1.3.6.1.4.1.2785.2.3.6.3.1.4.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetVTRDIVT | 1.3.6.1.4.1.2785.2.3.6.3.1.4.1.4 | INTEGER | accessible-for-notify | The Virtual Tributary (VT) instance. |
| INT acSonetVTRDIOpMode | 1.3.6.1.4.1.2785.2.3.6.3.1.4.1.5 | INTEGER | read-write | The Remote Defect Indiction signals have undergone a number of changes over the years, and now encompass two or even three different versions. See GR-253 6.2.1.3.3 for more information. |
| acSonetVTPLMTable | 1.3.6.1.4.1.2785.2.3.6.3.1.5 | not-accessible | The SONET/SDH VT Payload Label Mismatch Table. | |
| acSonetVTPLMEntry | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1 | not-accessible | An entry in the SONET/SDH VT Payload Label Mismatch Table. | |
| ACN acSonetVTPLMNodeId | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetVTPLMSlot | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetVTPLMPort | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetVTPLMVT | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1.4 | INTEGER | accessible-for-notify | The Virtual Tributary (VT) instance. |
| T/F acSonetVTPLMDetectEnable | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1.5 | TruthValue | read-write | Enables the detection of the VT Payload Label. |
| INT acSonetVTPLMTransmitedValue | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1.6 | INTEGER | read-write | The VT Payload Label that gets sent to the destination. See GR-253 Tables 3-4. |
| INT acSonetVTPLMExpectedValue | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1.7 | INTEGER | read-write | The expected VT Payload Label that is to be received. See GR-253 Tables 3-4. |
| INT acSonetVTPLMReceivedValue | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1.8 | INTEGER | read-only | The contents of the VT Payload Label that is received. See GR-253 Tables 3-4. |
| T/F acSonetVTPLMMismatchFailure | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1.9 | TruthValue | read-only | Mismatch failure declared for the VT Payload Label. |
| T/F acSonetVTPLMUnequipped | 1.3.6.1.4.1.2785.2.3.6.3.1.5.1.10 | TruthValue | read-only | Unequipped failure declared for the VT Payload Label. |
| acSonetVTProtectionTable | 1.3.6.1.4.1.2785.2.3.6.3.1.6 | not-accessible | The SONET/SDH VT Protection table. | |
| acSonetVTProtectionEntry | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1 | not-accessible | An entry in the SONET/SDH VT Protection table. | |
| ACN acSonetVTProtectionNodeId | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetVTProtectionSlot | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetVTProtectionPort | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetVTProtectionVT | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.4 | INTEGER | accessible-for-notify | The VT path instance for the port. |
| INT acSonetVTProtectionSwitchType | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.5 | INTEGER | read-write | This variable defines the VT path switch type as either revertive or nonrevertive. |
| I32 acSonetVTProtectionSFThreshold | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.6 | Integer32 | read-write | The threshold associated with Signal Fail (SF). This value determines the BER level for protection switching. |
| I32 acSonetVTProtectionSDThreshold | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.7 | Integer32 | read-write | The threshold associated with Signal Degrade (SD). This value determines the BER level for protection switching. |
| T/F acSonetVTProtectionProtectionSwitch | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.8 | TruthValue | read-only | This variable indicates when a protection switch is currently affecting this path. |
| I32 acSonetVTProtectionWTRTime | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.9 | Integer32 | read-write | This variable defines the UPSR Wait To Restore time. The time has one second granularity and may have a value in the range from 1 second to 720 seconds(12 minutes). |
| INT acSonetVTProtectionManSwitch | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.10 | INTEGER | read-write | This variable defines the UPSR manually initiated commands. |
| T/F acSonetVTProtectionActiveTraffic | 1.3.6.1.4.1.2785.2.3.6.3.1.6.1.11 | TruthValue | read-only | This variable indicates when UPSR active traffic is on this path. |
| acSonetFarEndVT | 1.3.6.1.4.1.2785.2.3.6.3.2 | |||
| acSonetFarEndVT15MinuteIntervalTable | 1.3.6.1.4.1.2785.2.3.6.3.2.1 | not-accessible | The SONET/SDH FarEndVT 15Minute Interval table. | |
| acSonetFarEndVT15MinuteIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1 | not-accessible | An entry in the SONET/SDH FarEndVT 15Minute Interval table. | |
| ACN acSonetFarEndVT15MinuteIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetFarEndVT15MinuteIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetFarEndVT15MinuteIntervalPort | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetFarEndVT15MinuteIntervalVT | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.4 | INTEGER | accessible-for-notify | The VT for which the set of statistics is available. |
| INT acSonetFarEndVT15MinuteIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.5 | INTEGER | accessible-for-notify | A number between 1 and 98, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current 15 minute interval. The interval identified by 2 is the most recently completed 15 minute interval. The interval identified by 97 is the oldest 15 minute interval. The interval identified by 98 is a total of the previous 96 stored 15 minute intervals. |
| T/F acSonetFarEndVT15MinuteIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.6 | TruthValue | read-only | This variable indicates if the data for this VT FE 15 minute interval is valid. |
| T/F acSonetFarEndVT15MinuteIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.7 | TruthValue | read-write | This flag is used to reset the data for this VT FE 15 minute interval. |
| NUM acSonetFarEndVT15MinuteIntervalESs | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.8 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH FarEndVT in the current 15 minute interval. |
| NUM acSonetFarEndVT15MinuteIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH FarEndVT in the current 15 minute interval. |
| NUM acSonetFarEndVT15MinuteIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH FarEndVT in the current 15 minute interval. |
| NUM acSonetFarEndVT15MinuteIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.3.2.1.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a FarEndVT in the current 15 minute interval. |
| acSonetFarEndVTDayIntervalTable | 1.3.6.1.4.1.2785.2.3.6.3.2.2 | not-accessible | The SONET/SDH FarEndVT Day Interval table. | |
| acSonetFarEndVTDayIntervalEntry | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1 | not-accessible | An entry in the SONET/SDH FarEndVT Day Interval table. | |
| ACN acSonetFarEndVTDayIntervalNodeId | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetFarEndVTDayIntervalSlot | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetFarEndVTDayIntervalPort | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetFarEndVTDayIntervalVT | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.4 | INTEGER | accessible-for-notify | The VT for which the set of statistics is available. |
| INT acSonetFarEndVTDayIntervalNumber | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.5 | INTEGER | accessible-for-notify | A number between 1 and 31, which identifies the interval for which the set of statistics is available. The interval identified by 1 is the ongoing, current day performance monitoring interval. The interval identified by 2 is the most recently completed day interval. The interval identified by 31 is the oldest day interval. |
| T/F acSonetFarEndVTDayIntervalValidStats | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.6 | TruthValue | read-only | This variable indicates if the data for this VT Day interval is valid. |
| T/F acSonetFarEndVTDayIntervalResetStats | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.7 | TruthValue | read-write | This flag is used to reset the data for this VT Day interval. |
| NUM acSonetFarEndVTDayIntervalESs | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.8 | PerfIntervalCount | read-only | The counter associated with the number of Errored Seconds encountered by a SONET/SDH FarEndVT in the current 15 minute interval. |
| NUM acSonetFarEndVTDayIntervalSESs | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.9 | PerfIntervalCount | read-only | The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH FarEndVT in the current 15 minute interval. |
| NUM acSonetFarEndVTDayIntervalCVs | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.10 | PerfIntervalCount | read-only | The counter associated with the number of Coding Violations encountered by a SONET/SDH FarEndVT in the current 15 minute interval. |
| NUM acSonetFarEndVTDayIntervalUASs | 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.11 | PerfIntervalCount | read-only | The counter associated with the number of Unavailable Seconds encountered by a FarEndVT in the current 15 minute interval. |
| acSonetFarEndVTThresholdTable | 1.3.6.1.4.1.2785.2.3.6.3.2.3 | not-accessible | The SONET/SDH FarEndVT Threshold Table. | |
| acSonetFarEndVTThresholdEntry | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1 | not-accessible | An entry in the SONET/SDH FarEndVT Threshold Table. | |
| ACN acSonetFarEndVTThresholdNodeId | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1.1 | AcNodeId | accessible-for-notify | The node id is the id for this specific node in the OSAP ring. |
| ACS acSonetFarEndVTThresholdSlot | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1.2 | AcSlotNumber | accessible-for-notify | The physical slot number of the port. |
| ACP acSonetFarEndVTThresholdPort | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1.3 | AcPortNumber | accessible-for-notify | The physical port number of the port. |
| INT acSonetFarEndVTThresholdVT | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1.4 | INTEGER | accessible-for-notify | The VT for which the set of statistics is available. |
| INT acSonetFarEndVTThresholdSelectionNum | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1.5 | INTEGER | accessible-for-notify | A number that selects either the 15 thresholds or the day thresholds. |
| ACA acSonetFarEndVTThresholdAdminStatus | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1.6 | AcAdminStatus | read-write | This field is used by the administrator to ensure only one client is performing management operations on this serial port at a time. When the field is read as available(0), the client can write the value locked(1) into this field to prevent a second client from performing managment ops on this instance. |
| INT acSonetFarEndVTThresholdESs | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1.7 | INTEGER | read-write | The threshold associated with Errored Seconds. |
| INT acSonetFarEndVTThresholdSESs | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1.8 | INTEGER | read-write | The threshold associated with Severely Errored Seconds. |
| INT acSonetFarEndVTThresholdCVs | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1.9 | INTEGER | read-write | The threshold associated with Coding Violations. |
| INT acSonetFarEndVTThresholdUASs | 1.3.6.1.4.1.2785.2.3.6.3.2.3.1.10 | INTEGER | read-write | The threshold associated with Unavailable Secondss. |
RFC description
Appian Communications physical SONET port section, line, and path performance management.
Start monitoring Appian Communications OSAP SONET/optical access platform (legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.