All MIBs › APPIAN-PPORT-SONET-MIB › acSonetFarEndVTDayIntervalESs
acSonetFarEndVTDayIntervalESs
Module: APPIAN-PPORT-SONET-MIB
OID (symbolic): APPIAN-PPORT-SONET-MIB::acSonetFarEndVTDayIntervalESs
OID (numeric): 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.8
Node type: OBJECT-TYPE
Type: PerfIntervalCount
Access: read-only
Description: The counter associated with the number of Errored Seconds encountered by a SONET/SDH FarEndVT in the current 15 minute interval.
What is acSonetFarEndVTDayIntervalESs?
This read-only counter sums Errored Seconds at the far-end VT across the entire day. It measures 24-hour remote transmission errors. A value of 100 indicates the far end accumulated 100 error seconds.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.8 snmpwalk -v2c -c public <target> APPIAN-PPORT-SONET-MIB::acSonetFarEndVTDayIntervalESs
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.8.1 snmpget -v2c -c public <target> APPIAN-PPORT-SONET-MIB::acSonetFarEndVTDayIntervalESs.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> acSonetFarEndVTDayIntervalESs.1
Start monitoring Appian Communications OSAP SONET/optical access platform (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the APPIAN-PPORT-SONET-MIB::acSonetFarEndVTDayIntervalESs OID value, configure state conditions and alerts, and monitor any Appian Communications OSAP SONET/optical access platform (legacy) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2785 | appian | APPIAN-SMI-MIB |
| 1.3.6.1.4.1.2785.2 | acOsap | APPIAN-SMI-MIB |
| 1.3.6.1.4.1.2785.2.3 | acPport | APPIAN-SMI-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2785.2.3.6 | acSonet | APPIAN-PPORT-SONET-MIB |
| 1.3.6.1.4.1.2785.2.3.6.3 | acSonetObjectsVT | APPIAN-PPORT-SONET-MIB |
| 1.3.6.1.4.1.2785.2.3.6.3.2 | acSonetFarEndVT | APPIAN-PPORT-SONET-MIB |
| 1.3.6.1.4.1.2785.2.3.6.3.2.2 | acSonetFarEndVTDayIntervalTable | APPIAN-PPORT-SONET-MIB |
| 1.3.6.1.4.1.2785.2.3.6.3.2.2.1 | acSonetFarEndVTDayIntervalEntry | APPIAN-PPORT-SONET-MIB |
| 1.3.6.1.4.1.2785.2.3.6.3.2.2.1.8 | acSonetFarEndVTDayIntervalESs | APPIAN-PPORT-SONET-MIB |