All MIBs › X25-OPT-MIB
Category: X.25 and Legacy WAN
Description: Supplies optional configuration and operational objects for interfaces on X.25 packet-switched networks.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is X25-OPT-MIB?
X25-OPT-MIB is a supplementary MIB module defining optional configuration and operational objects for X.25 packet-switched network interfaces, extending the base IETF X.25 Packet Level/LAPB MIB framework (RFC 1382). It exposes port-level protocol-group configuration data, as suggested by its sample objects, grouping physical ports under a specific X.25 protocol configuration on the host platform. Its monitoring value is primarily configuration-status rather than hardware health: confirming that ports are grouped under the correct protocol configuration is necessary for X.25 call setup and packet-level operation to work as intended. The object names present (prefixed cdx6500) indicate this particular instance targets a specific router/FRAD platform's X.25 port hardware while still following the general X.25 MIB conventions. It is typically deployed on legacy X.25 packet-switched network access devices or routers providing X.25 connectivity over serial links. Engineers can download the X25-OPT-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in X25-OPT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- X.25 packet-switched network access devices/routers (e.g., cdx6500 platform)
- vendor-neutral, standards-based MIB extension, not tied to a single manufacturer
Monitoring Examples
cdx6500PCTPortProtocolGroup and cdx6500PSTPortProtocolGroup group specific physical ports (PCT and PST) under an X.25 protocol configuration on the platform. An administrator would poll these objects to confirm that a given port is assigned to the intended protocol group. A port found in the wrong or an unconfigured protocol group would reveal a misconfiguration that would prevent X.25 call setup from succeeding on that port.
What Can Be Monitored
- X.25 port protocol-group assignment
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge | |
| enterprises |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| codex | 1.3.6.1.4.1.449 | |||
| cdxProductSpecific | 1.3.6.1.4.1.449.2 | |||
| cdx6500 | 1.3.6.1.4.1.449.2.1 | |||
| cdx6500Configuration | 1.3.6.1.4.1.449.2.1.2 | |||
| cdx6500CfgProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1 | |||
| cdx6500PCTPortProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1.1 | |||
| cdx6500PPCTX25PortTable | 1.3.6.1.4.1.449.2.1.2.1.1.2 | not-accessible | A table of X.25 Port configuration entries. | |
| cdx6500PPCTX25PortEntry | 1.3.6.1.4.1.449.2.1.2.1.1.2.1 | not-accessible | An X.25 Configuration Table entry. Each entry contains the configuration parameters for a single X.25 port. | |
| INT cdx6500X25CfgPortNumber | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.1 | INTEGER | read-only | Port number for this X.25 port. |
| INT cdx6500X25CfgConnType | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.2 | INTEGER | read-write | Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required. dtr - dedicated, require the data terminal ready signal (DTR). dtrd - same as DTR, except data set ready (DSR) drops between calls. dimo - port handshakes with attached dial modem dimoa - same as DIMO except DSR never raised on incoming call from modem. dimob - same as DIMO except DSR follows DTR on incoming call from modem. dimov - port handshakes with attached V.25 bis dial modem. emri - port emulates a dial modem with ring indicator (RI). emdc - port emulates a dial modem with data carrier detect (DCD). simpv - SIMP/DIMOv, modem will switch from Leased to Dial-only mode when leased line goes down (used with Link Backup only). simpb - simple, no control signals required for data transmission and reception. By default output leads will be low. |
| STR cdx6500X25CfgPortCont | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.3 | DisplayString | read-write | Specify any of the following port control options: NONE - no option specified. MB - raise Pin 22 when the port becomes disabled. |
| INT cdx6500X25CfgClockSource | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.4 | INTEGER | read-write | int - internal clock source. ext - external clock source. extint - internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). extlp must be configured in conjunction with extint. |
| INT cdx6500X25CfgClockSpeed | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.5 | INTEGER | read-write | This is the speed of the port in bits per second, when using internal clocking. The highest available speed is dependant on the card type, and on the interface type. See the 6500 Series Configuration and Administration Manual for proper values. |
| INT cdx6500X25CfgAdmnInterfaceMode | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.6 | INTEGER | read-write | The logical link address must be set to complementary values in devices at each end of the link: dte - link to have logical DTE address (A). dce - link to have logical DCE address (B). negotiate - link ends will negotiate which end is DCE address (B). This option is available only if the correct CSK is enabled. |
| INT cdx6500X25CfgAdmnNumberPVCs | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.7 | INTEGER | read-write | Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table. |
| INT cdx6500X25CfgStartPVCChanNum | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.8 | INTEGER | read-write | This is the starting logical channel number for the Permanent Virtual Circuits on this link. Not used if the number of PVCs = 0. |
| INT cdx6500X25CfgNumberSVCs | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.9 | INTEGER | read-write | Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. |
| INT cdx6500X25CfgStartSVCChanNum | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.10 | INTEGER | read-write | This is the starting logical channel number for the Switched Virtual Circuits on this link. Not used if the number of SVCs = 0. |
| INT cdx6500X25CfgInitFrame | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.11 | INTEGER | read-write | Specify the initial frame required by other end for link startup: none - do nothing (other end initiates link-up). sabm - send SABM. disc - send DISC, then SABM. |
| INT cdx6500X25CfgT1RetryTimer | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.12 | INTEGER | read-write | T1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds). |
| INT cdx6500X25CfgT4PollTimer | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.13 | INTEGER | read-write | This sets the time an idle link is probed for assurance of connection to the remote device. 0 - disable the timer X - X is in tenths of a second (e.g. 40 = 4.0 seconds) and must be set greater than T1. |
| INT cdx6500X25CfgN2TransTries | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.14 | INTEGER | read-write | The maximum number of attempts allowed to complete a transmission. |
| INT cdx6500X25CfgFrameSeqCounting | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.15 | INTEGER | read-write | Port uses normal or extended frame sequence numbering norm - normal sequence counting (Modulo 8). ext - extended sequencing (Modulo 128). |
| INT cdx6500X25CfgKFrameWindow | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.16 | INTEGER | read-write | Frame level window size must be set to the same value in devices at each end of the link. |
| INT cdx6500X25CfgAdmnPacketSequencing | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.17 | INTEGER | read-write | Port uses normal or extended packet level sequence numbers : norm - normal sequencing (Modulo 8). ext - extended sequencing (Modulo 128). The value must be the same in devices at each end of the link. |
| INT cdx6500X25CfgWPacketWindow | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.18 | INTEGER | read-write | Packet level window size must be set to the same value in devices at each end of the link. |
| INT cdx6500X25CfgPPacketSize | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.19 | INTEGER | read-write | This is the maximum packet size used on X.25 links. For proper operation, the size must be the same in devices at each end of the link. |
| INT cdx6500X25CfgMaxNegotPacketSize | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.20 | INTEGER | read-write | This is the maximum negotiated packet size allowed for inbound and outbound calls on this X.25 link. |
| INT cdx6500X25CfgDataQueueUpper | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.21 | INTEGER | read-write | This is the maximum number of data packets a channel on this port will queue for transmission before invoking flow control to the attached channel |
| INT cdx6500X25CfgDataQueueLower | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.22 | INTEGER | read-write | This is the number of data packets a channel on this port will have queued for transmission when it releases flow control to the attached channel |
| INT cdx6500X25CfgAdmnRestartTimer | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.23 | INTEGER | read-write | Restart-Request timeout timer in seconds. If timer expires, request is sent again. |
| INT cdx6500X25CfgAdmnResetTimer | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.24 | INTEGER | read-write | Reset-Request timeout timer in seconds. If timer expires, request is sent again. |
| INT cdx6500X25CfgAdmnCallTimer | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.25 | INTEGER | read-write | Call-Request timeout timer in seconds. If timer expires, call is cleared. |
| INT cdx6500X25CfgAdmnClearTimer | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.26 | INTEGER | read-write | Clear-Request timeout timer in seconds. If timer expires, request is sent again. |
| STR cdx6500X25CfgOutDelFacilities | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.27 | DisplayString | read-write | Specify facilities deleted from an outbound call before it is forwarded: NONE - no facilities deleted. THRO - delete throughput class negotiation. NUI - delete network user identification. CUG - delete closed user group. Any combination of above specified by summing (e.g. THRO+NUI. . .). |
| STR cdx6500X25CfgOutAddFacilities | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.28 | DisplayString | read-write | Specify facilities added to an outbound call before it is forwarded: NONE - no facilities added. REV - add reverse charging. PACK - add packet size negotiation. WIND - add window size negotiation. Any combination of above specified by summing (e.g. PACK+WIND+. . .). |
| STR cdx6500X25CfgOutBarFacilities | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.29 | DisplayString | read-write | Specify facilities which, if present in an outbound call will be blocked by the port: NONE - no facility blocked. REV - bar reverse charging. FAST - bar fast select. BCUG - bar Bilateral Closed User Group. DGRAM - bar datagram. Any combination of above specified by summing (e.g. REV+FAST). |
| STR cdx6500X25CfgInBarFacilities | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.30 | DisplayString | read-write | Specify facilities which, if present in an inbound call, will be blocked by the port: NONE - no facility blocked. BCUG - bar Bilateral Closed User Group. DGRAM - bar datagram. REV - bar Reverse Charging. Any combination of above specified by summing (e.g. DGRAM+BCUG). |
| STR cdx6500X25CfgOptions | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.31 | DisplayString | read-write | Select options on this X.25 port as follows: NONE - no option specified. 1980 - use X.25 1980. NUI - perform network user identification validation check. PDN - connected to Public Data Network. CUD - use call user data subaddressing. IBAR - bar all calls coming in from X.25 port user. OBAR - bar all calls going out to X.25 port user. CBCK - allow routing inbound calls back out this port. CUG - check closed user group; otherwise, CUG passes transparently. CAUSE - pass cause, diagnostic, code in outbound packets. HOLD - hold calls over link restart. NRST - do not send restart packet on link-up. BKUP - this is a backup port to be activated if other ports are down. INL - inter-node link. Link goes to another Vanguard device.INL may be a poor choice for high speed links.INLB is set with INL to improve the performance of high speed links.INLB can be configured in the More X25 Options parameter. INLA - set with INL option when an X.25 link connection is to a 6500 node using 2.12.04 or earlier. DELAY - enable Delay and Path trace on this link (link must connected to Rel. 4.xx node). Any combination of above specified by summing (e.g. 1980+NUI+. . .). |
| INT cdx6500X25CfgNumRoutDigits | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.32 | INTEGER | read-write | This specifies the number of routing digits in the call user data. It is used on X.25 links attached to a Public Data Network where the private network address is carried in the call user data. |
| INT cdx6500X25CfgPortDigitsToStrip | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.33 | INTEGER | read-write | For X.25 links connected to a Public Data Network, this parameter specifies the number of prefix digits to remove from the called address before forwarding the call to the PDN. |
| INT cdx6500X25CfgInDigitsToStrip | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.34 | INTEGER | read-write | For X.25 links connected to a Public Data Network, this parameter specifies the number of prefix digits to remove from the incoming calling address before forwarding the call from the PDN. |
| STR cdx6500X25CfgRestrictConn | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.35 | DisplayString | read-write | All calls entering this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. Blank this field to disable this function. |
| STR cdx6500X25CfgPortAddress | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.36 | DisplayString | read-write | On X.25 links: If the X.25 Option REGO or REGI is selected, this address is inserted into the calling address field of the outbound or inbound call packet. On MUX links: When a MUX channel makes a call, the subaddress of the channel is appended to this address and inserted into the calling address field of the call packet. |
| STR cdx6500X25CfgCUGMember | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.37 | DisplayString | read-write | The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except `--') and separated by a comma. ( e.g. 12,34,56,09,02,03 ). `--' - No CUG Membership. 00-99 - CUG Membership. |
| INT cdx6500X25CfgBillRec | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.38 | INTEGER | read-write | This controls whether billing (accounting) records will be created for calls on this port. |
| INT cdx6500X25CfgSubAddrSize | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.39 | INTEGER | read-write | For ports connected to a Public Data Network, this parameter specifies the number of digits in the subaddress of an X.25 address. |
| INT cdx6500X25CfgIdleDiscTimer | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.40 | INTEGER | read-write | The time in seconds that the port must be idle (no calls) before being automatically disconnected. A value of 0 disables the Idle Disconnect feature. This feature may only be enabled on DIMO/DIMOa/DIMOb/DIMOv/SIMPv ports with the BKUP option selected. |
| INT cdx6500X25CfgCallSecurity | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.41 | INTEGER | read-write | For ports used as V.25 bis backup, this parameter specifies the type of call security to use prior to the link being detected up : disable - Disable will allow both incoming and outgoing calls. enable - Enable will allow ONLY outgoing calls. Incoming calls will be immediately terminated. This parameter is only used with Link Backup. |
| INT cdx6500X25CfgProtectLevel | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.42 | INTEGER | read-write | This specifies the level of data or connection protection which will be applied to calls to or from this port. The actual level for a call will be negotiated to the lesser of this level and the level configured for the other end of the call : none - No protection. cpOnly - Connection protection only. fullDcp - Full data and connection protection. |
| INT cdx6500X25CfgReconnTimeout | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.43 | INTEGER | read-write | This specifies the number of seconds that DCP on the originating side will wait between reconnection attempts. |
| INT cdx6500X25CfgReconnTriesLimit | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.44 | INTEGER | read-write | This specifies the number of times that DCP on the originating side will attempt to reconnect before clearing the call. If 0 is entered, it will not attempt to reconnect. |
| STR cdx6500X25CfgFacilSubscripCont | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.45 | DisplayString | read-only | NONE - Subscription to facilities not enforced. FCN-ON - Flow Control Negotiation enabled. Packet and Window size negotiation facilities in an inbound call will be allowed. Packet and Window size facilities will always be included in outbound calls and call accepted/ connected when this parameter is set. FCN-OFF - Flow Control Negotiation disabled. Inbound calls containing Packet and Window size facilities will be cleared. Packet and Window size facilities will not be present in outbound calls and call accepted/ connected when this parameter is set. TCN-ON - Throughput Class Negotiation enabled. The throughput class negotiation facility in an inbound call will be allowed. The throughput class negotiation facility will always be included in outbound calls and call accepted/connected when this parameter is set. The facility is passed onward to the destination in the call packet transparently and does not alter the handling of the SVC data within the node. TCN-OFF - Throughput Class Negotiation disabled. Inbound calls containing the throughput class negotiation facility will be cleared. The throughput class negotiation facility will not be present in outbound calls and call accepted/connected when this parameter is set. Some combinations of above options are allowed (e.g. FCN-ON+TCN-ON). |
| INT cdx6500X25CfgAlarmPriority | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.46 | INTEGER | read-write | Specify the severity level of LINK UP and LINK DOWN alarms : network - Severity HIGH alarms will be generated. access - Severity LOW alarms will be generated. |
| STR cdx6500X25CfgAddrTrans | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.47 | DisplayString | read-write | Select any of the following address translation options NONE - no option specified Outbound Call Processing: DEDO - delete called address. DEGO - delete calling address. REGO - replace calling address with configured Port Address. REGSO - replace calling address with configured Port Address plus Inbound Subaddress obtained from the Inbound Call Translation Table entry where Private Network Address matches the entire calling address. INGO - replace calling address with configured Port Address and retain original calling subaddress. SAGO - strip calling address, but retain subaddress. Inbound Call Processing: INGI - replace calling address with configured Port Address and retain original calling subaddress. REGI - replace calling address with configured Port Address. SRGI - select route from the Calling Address Translation Table by replacing the called address with the Private Network Address where the Inbound Calling Address matches the beginning of the calling address. Call Accept Processing: DADA - delete called address in inbound/outbound call accept. DAGA - delete calling address in inbound/outbound call accept. IADD - copy called and calling addresses from call request into outbound call accepted/connected. Some of the options may be combined (e.g. DEDO+DEGO+...) |
| INT cdx6500X25CfgNumberInSVCs | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.48 | INTEGER | read-write | Number of logical channels used in One Way Incoming Switched Virtual Circuits. The total number of PVC, One Way Incoming, One Way Outgoing and Two Way SVC channels should be kept as small as possible and consistent with needs. |
| INT cdx6500X25CfgStartInSVCChanNum | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.49 | INTEGER | read-write | This is the starting logical channel number for the One Way Incoming Switched Virtual Circuits on this link. Not used if the number of One Way Incoming SVCs = 0. |
| INT cdx6500X25CfgNumberOutSVCs | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.50 | INTEGER | read-write | Number of logical channels used in One Way Outgoing Switched Virtual Circuits. The total number of PVC, One Way Outgoing, One Way Outgoing and Two Way SVC channels should be kept as small as possible and consistent with needs. |
| INT cdx6500X25CfgStartOutSVCChanNum | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.51 | INTEGER | read-write | This is the starting logical channel number for the One Way Outgoing Switched Virtual Circuits on this link. Not used if the number of One Way Outgoing SVCs = 0. |
| INT cdx6500X25CfgChargeInfoReq | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.52 | INTEGER | read-write | This parameter specifies whether Charging Information has to be sent even without requesting. |
| INT cdx6500X25CfgVerfnTimer | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.53 | INTEGER | read-write | Specify the NUI verification timer in seconds. The call is cleared if timer expires. |
| INT cdx6500X25CfgValdFailures | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.54 | INTEGER | read-write | The maximum number of successive NUI verification failures an X.25 DTE can tolerate when making verification attempts timer expires. |
| INT cdx6500X25CfgActionType | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.55 | INTEGER | read-write | This specifies the course of action to be taken if the NUI violations exceed the configured threshold count. This parameter is effective only if the X25 options parameter is set to CNUI NONE - No action is taken. DISC - All connections on the port are broken. DEGR - Port is busied-out for one minute then it is re-enabled. LOCK - All connections on the port are broken and the port is disabled. |
| INT cdx6500X25CfgLineIdleMode | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.56 | INTEGER | read-write | Specify any of the following line idle mode options: FLAG - Flag fill between frames MARK - Mark idle between frames |
| STR cdx6500X25CfgConfOption | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.57 | DisplayString | read-write | Select any of the following conformance control options: NONE - no option specified CHKFAC - Checking of facility codes enabled. |
| INT cdx6500X25CfgInvertTxClk | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.58 | INTEGER | read-write | This parameter specifies whether the phase of the transmit clock should be inverted. NO - Don't invert YES - Invert |
| INT cdx6500X25CfgDimType | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.59 | INTEGER | read-write | Specify the physical interface type to be used for this port: V.36 - V.36 physical interface EIA-530A - EIA-530A physical interface V.35 - V.35 physical interface X.21 - X.21 physical interface RS-449 - RS-449 physical interface EIA-530 - EIA-530 physical interface RS-232 - RS-232 physical interface |
| STR cdx6500X25CfgMoreOptions | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.60 | DisplayString | read-write | Select more options on this X.25 port as follows: NONE - no option specified INLB - set with INL option to improve performance if inter-node link is a high speed link |
| INT cdx6500X25CfgPsfFlag | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.61 | INTEGER | read-write | Enable or Disable Port Selection Facility feature. Used to control access to ports for Select user group applications. |
| INT cdx6500X25CfgElectricalInterfaceType | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.62 | INTEGER | read-write | Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled |
| INT cdx6500X25CfgV24ElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.63 | INTEGER | read-write | Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal |
| INT cdx6500X25CfgHighSpeedElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.2.1.64 | INTEGER | read-write | Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable |
| cdx6500CfgGeneralGroup | 1.3.6.1.4.1.449.2.1.2.2 | |||
| cdx6500CGTInboundCallTranTable | 1.3.6.1.4.1.449.2.1.2.2.2 | not-accessible | All of the configuration parameters relevant to the Inbound Call Translation table. | |
| cdx6500CGTInboundCallTranEntry | 1.3.6.1.4.1.449.2.1.2.2.2.1 | not-accessible | A row of Inbound Call Translation configuration parameters. | |
| INT cdx6500InCallTranEntryNum | 1.3.6.1.4.1.449.2.1.2.2.2.1.1 | INTEGER | read-only | This is not a configuration parameter. Instead, it identifies the particular Inbound Call Translation Table entry being configured by the other parameters in the record. |
| STR cdx6500InCallTranInSubAddr | 1.3.6.1.4.1.449.2.1.2.2.2.1.2 | DisplayString | read-write | This is the subaddress contained in an inbound call from another network, usually a public data network (PDN). It will be translated into a private network address before the call is forwarded. |
| STR cdx6500InCallTranPrivNetAddr | 1.3.6.1.4.1.449.2.1.2.2.2.1.3 | DisplayString | read-write | This is the private network address to translate to, before forwarding calls from a PDN. |
| cdx6500CGTOutboundCallTranTable | 1.3.6.1.4.1.449.2.1.2.2.3 | not-accessible | All of the configuration parameters relevant to the Outbound Call Translation table. | |
| cdx6500CGTOutboundCallTranEntry | 1.3.6.1.4.1.449.2.1.2.2.3.1 | not-accessible | A row of Outbound Call Translation configuration parameters. | |
| INT cdx6500OutCallTranEntryNum | 1.3.6.1.4.1.449.2.1.2.2.3.1.1 | INTEGER | read-only | This is not a configuration parameter. Instead, it identifies the particular Outbound Call Translation Table entry being configured by the other parameters in the record. |
| STR cdx6500OutCallTranPrivNetAddr | 1.3.6.1.4.1.449.2.1.2.2.3.1.2 | DisplayString | read-write | This is the private network address contained in an outbound call to another network, usually a public data network (PDN). It will be translated into a PDN address before the call is forwarded. |
| STR cdx6500OutCallTranOutNetAddr | 1.3.6.1.4.1.449.2.1.2.2.3.1.3 | DisplayString | read-write | This is the public network address to translate to, before forwarding calls to a PDN. |
| INT cdx6500OutCallTranOptions | 1.3.6.1.4.1.449.2.1.2.2.3.1.4 | INTEGER | read-write | This parameter specifies options for outbound call address translation as follows: olda - insert the original called address into outbound call user data. newvalNone - same functionality as 'none', new enumeration added for RFC1155 compatibility. |
| cdx6500CGTCallingAddrTranTable | 1.3.6.1.4.1.449.2.1.2.2.13 | not-accessible | All of the configuration parameters relevant to the Calling AddressTranslation table. | |
| cdx6500CGTCallingAddrTranEntry | 1.3.6.1.4.1.449.2.1.2.2.13.1 | not-accessible | A row of Calling Address Translation configuration parameters. | |
| INT cdx6500CalladdrtranEntryNum | 1.3.6.1.4.1.449.2.1.2.2.13.1.1 | INTEGER | read-only | This is not a configuration parameter. Instead, it identifies the entry being configured by the other parameters in the record. |
| STR cdx6500CalladdrtranInCallAddr | 1.3.6.1.4.1.449.2.1.2.2.13.1.2 | DisplayString | read-write | This is the calling address contained in an inbound call, it will be translated into a private network address (if a match is found in the Translation Table), before the call is forwarded. |
| STR cdx6500CalladdrtranPrivNetAddr | 1.3.6.1.4.1.449.2.1.2.2.13.1.3 | DisplayString | read-write | This is the private network address to translate to, before forwarding the call. |
| cdx6500CGTCudBaseAddrTranTable | 1.3.6.1.4.1.449.2.1.2.2.23 | not-accessible | All of the configuration parameters relevant to the CUD Base AddressTranslation table. | |
| cdx6500CGTCudBaseAddrTranEntry | 1.3.6.1.4.1.449.2.1.2.2.23.1 | not-accessible | A row of CUD Base Address Translation configuration parameters. | |
| INT cdx6500CudBaseaddrtranEntryNum | 1.3.6.1.4.1.449.2.1.2.2.23.1.1 | INTEGER | read-only | This is not a configuration parameter. Instead, it identifies the entry being configured by the other parameters in the record. |
| STR cdx6500CudBaseStr | 1.3.6.1.4.1.449.2.1.2.2.23.1.2 | DisplayString | read-write | Enter the sub-string to search in the CUD for the incoming call for translating it into Called address. For searching from index in the CUD the name can be specified as (7)DADADIFUBBBB, it will skip 7 characters of the CUD and match DADAIFUBBBB in the CUD starting at Position 8. |
| STR cdx6500CudBaseAddr | 1.3.6.1.4.1.449.2.1.2.2.23.1.3 | DisplayString | read-write | Enter the X.25 Address which will be inserted for called address of incoming X.25 call packet if the configured CUD string is matched in the CUD of the incoming X.25 Call packet. |
| cdx6500Statistics | 1.3.6.1.4.1.449.2.1.3 | |||
| cdx6500StatProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1 | |||
| cdx6500PSTPortProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1.1 | |||
| cdx6500PPSTX25PortTable | 1.3.6.1.4.1.449.2.1.3.1.1.2 | not-accessible | A table of X.25 Port statistics. | |
| cdx6500PPSTX25PortEntry | 1.3.6.1.4.1.449.2.1.3.1.1.2.1 | not-accessible | An X.25 Statistics Table entry. Each entry contains the statistics for a single X.25 port. | |
| INT cdx6500X25StatPortNumber | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.1 | INTEGER | read-only | The port number for this X.25 port. |
| STR cdx6500X25StatPortStatus | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.2 | DisplayString | read-only | Status of this port : Up - Port is active Down - Port Is inactive Disabled - An operator has disabled the port Busy Out - an operator has busied out the port |
| INT cdx6500X25StatPortState | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.3 | INTEGER | read-only | discPhase - Disconnect Phase. linkDisk - Link Disconnect. linkSetup - The port is sending SABM frames and waiting for a UA response. sabmColl - SABM Collision. frameReject - The port has rejected a received frame. normal - The port sending/receiving data. remoteBusy - The port is receiving RNR frames. reset - The port is being reset. sendRej - The port is sending REJ frames. rbSr - The port is receiving RNR frames and sending REJ frames. |
| INT cdx6500X25StatActualPortSpeed | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.4 | INTEGER | read-only | This is the speed of the port when Clock = INT; this is the detected clock speed if Clock = EXT. If Port Speed is 0, Clock = EXT, but clocking is not being received fom attatched device. |
| INT cdx6500X25StatPortUtilIn | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.5 | INTEGER | read-only | Percentage of port bandwidth in use. |
| INT cdx6500X25StatPortUtilOut | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.6 | INTEGER | read-only | Percentage of port bandwidth in use. |
| GAU cdx6500X25StatMaxSVCCount | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.7 | Gauge | read-only | Maximum number of SVCs in use since last node, port or statistics reset. |
| INT cdx6500X25StatCurrSVCCount | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.8 | INTEGER | read-only | Current number of SVCs in use. |
| CTR cdx6500X25StatInChars | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.9 | Counter | read-only | Number of characters received since last node, port or statistics reset. |
| CTR cdx6500X25StatOutChars | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.10 | Counter | read-only | Number of characters sent since last node, port or statistics reset. |
| CTR cdx6500X25StatInPkts | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.11 | Counter | read-only | Number of packets received since last node, port or statistics reset. |
| CTR cdx6500X25StatOutPkts | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.12 | Counter | read-only | Number of packets sent since last node, port or statistics reset. |
| CTR cdx6500X25StatInDataFrames | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.13 | Counter | read-only | Number of frames received since last node, port or statistics reset. |
| CTR cdx6500X25StatOutDataFrames | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.14 | Counter | read-only | Number of frames sent since last node, port or statistics reset. |
| INT cdx6500X25StatNumPktsQueued | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.15 | INTEGER | read-only | Number of packets currently queued. |
| INT cdx6500X25StatCharRateIn | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.16 | INTEGER | read-only | Summary of the characters being received by the port. |
| INT cdx6500X25StatCharRateOut | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.17 | INTEGER | read-only | Summary of the characters being sent by the port. |
| INT cdx6500X25StatPktRateIn | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.18 | INTEGER | read-only | Summary of the packets being received by the port. |
| INT cdx6500X25StatPktRateOut | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.19 | INTEGER | read-only | Summary of the packets being sent by the port. |
| INT cdx6500X25StatFrameRateIn | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.20 | INTEGER | read-only | Summary of the frames being received by the port. |
| INT cdx6500X25StatFrameRateOut | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.21 | INTEGER | read-only | Summary of the frames being sent by the port. |
| NUM cdx6500X25StatOverrunErrs | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.22 | Counter16 | read-only | Number of Overrun errors since the last node or statistics reset. |
| NUM cdx6500X25StatUnderrunErrs | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.23 | Counter16 | read-only | Number of Underrun errors since the last node or statistics reset. |
| NUM cdx6500X25StatCRCErrs | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.24 | Counter16 | read-only | Number of CRC errors since the last node or statistics reset. |
| CTR cdx6500X25StatInInfoFrames | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.25 | Counter | read-only | Number of Info frames received since last node, port or statistics reset. |
| CTR cdx6500X25StatOutInfoFrames | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.26 | Counter | read-only | Number of Info frames sent since last node, port or statistics reset. |
| CTR cdx6500X25StatInRNRFrames | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.27 | Counter | read-only | Number of frames received since last node, port or statistics reset indicating RNR. |
| CTR cdx6500X25StatOutRNRFrames | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.28 | Counter | read-only | Number of frames sent since last node, port or statistics reset indicating RNR. |
| CTR cdx6500X25StatInRRFrames | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.29 | Counter | read-only | Number of frames received since last node, port or statistics reset indicating RR. |
| CTR cdx6500X25StatOutRRFrames | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.30 | Counter | read-only | Number of frames sent since last node, port or statistics reset indicating RR. |
| CTR cdx6500X25StatInREJFrames | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.31 | Counter | read-only | Number of frames received since last node, port or statistics reset indicating REJ. |
| CTR cdx6500X25StatOutREJFrames | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.32 | Counter | read-only | Number of frames sent since last node, port or statistics reset indicating REJ. |
| CTR cdx6500X25StatInDataPkts | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.33 | Counter | read-only | Number of data packets received since last node, port or statistics reset. |
| CTR cdx6500X25StatOutDataPkts | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.34 | Counter | read-only | Number of data packets sent since last node, port or statistics reset. |
| INT cdx6500X25StatNumRxCallsSinceLastReset | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.35 | INTEGER | read-only | The number of inbound calls that were attempted since the last statistics reset. |
| INT cdx6500X25StatNumRxCallsRejected | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.36 | INTEGER | read-only | The number of inbound calls that were rejected since the last statistics reset. |
| INT cdx6500X25StatRxLastCallFailureCause | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.37 | INTEGER | read-only | The reason the last inbound call was rejected, since the last statistics reset. The posssible values are: notAvailable : Value not available if not a (virtual) switched data port. noFailureReported : No call failure noAvailableVirtualPort : No virtual port available securityViolation : Password security failed noResourcesAvailable : No resources available callRejected : Call failed by Xircom card invalidPhoneNumber : Phone number is incorrect outgoingCallRequestTimeout : Outgoing call req timeout callCollision : Call collision virtualPortNotAvailable : This port is not available invalidConfiguration : Configuration is incorrect failureNotSupported : Failure is not supported |
| STR cdx6500X25StatRxLastCalledNumber | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.38 | DisplayString | read-only | The phone number of the virtual port of the last ISDN call made into this port. |
| STR cdx6500X25StatRxLastCallingNumber | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.39 | DisplayString | read-only | The phone number of last party to make an ISDN call into this port. |
| STR cdx6500X25StatRxMinCallDuration | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.40 | DisplayString | read-only | The minimum call duration of all inbound ISDN calls made into this port, since the last statistics reset. |
| STR cdx6500X25StatRxMaxCallDuration | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.41 | DisplayString | read-only | The maximum call duration of all inbound ISDN calls made into this port, since the last statistics reset. |
| STR cdx6500X25StatRxAvgCallDuration | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.42 | DisplayString | read-only | The average call duration of all inbound ISDN calls made into this port, since the last statistics reset. |
| INT cdx6500X25StatNumTxCallsSinceLastReset | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.43 | INTEGER | read-only | The number of outbound calls that were attempted since the last statistics reset. |
| INT cdx6500X25StatNumTxCallsRejected | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.44 | INTEGER | read-only | The number of outbound calls that were rejected since the last statistics reset. |
| INT cdx6500X25StatTxLastCallFailureCause | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.45 | INTEGER | read-only | The reason the last inbound call was rejected, since the last statistics reset. The posssible values are: notAvailable : Value not available if not a (virtual) switched data port. noFailureReported : No call failure noAvailableVirtualPort : No virtual port available securityViolation : Password security failed noResourcesAvailable : No resources available callRejected : Call failed by Xircom card invalidPhoneNumber : Phone number is incorrect outgoingCallRequestTimeout : Outgoing call req timeout callCollision : Call collision virtualPortNotAvailable : This port is not available invalidConfiguration : Configuration is incorrect failureNotSupported : Failure is not supported |
| STR cdx6500X25StatTxLastCalledNumber | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.46 | DisplayString | read-only | The phone number of the last ISDN call made by a virtual port from this port. |
| STR cdx6500X25StatTxLastCallingNumber | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.47 | DisplayString | read-only | The phone number of the virtual port that made the last ISDN call from this port. |
| STR cdx6500X25StatTxMinCallDuration | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.48 | DisplayString | read-only | The minimum call duration of all outbound ISDN calls made from this port, since the last statistics reset. |
| STR cdx6500X25StatTxMaxCallDuration | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.49 | DisplayString | read-only | The maximum call duration of all outbound ISDN calls made from this port, since the last statistics reset. |
| STR cdx6500X25StatTxAvgCallDuration | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.50 | DisplayString | read-only | The average call duration of all outbound ISDN calls made from this port, since the last statistics reset. |
| INT cdx6500X25StatSignalingState | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.51 | INTEGER | read-only | ISDN call signaling state. The possible values are: idle : No ISDN call present. ringing : Pending outgoing ISDN call request. connected : ISDN call is connected. congested : Congested mode. disabled : Virtual Port is disabled. dChannelDown : D-channel is down. disabledChannelDown : Disable and D-channel is down. disconnecting : Pending ISDN call disconnection. notAvailable : Value not available if not a (virtual) switched data port. |
| INT cdx6500X25StatMaxPortUtilIn | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.52 | INTEGER | read-only | Max percentage of port bandwidth in use since last node, port or statistics reset. |
| INT cdx6500X25StatMaxPortUtilOut | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.53 | INTEGER | read-only | Max percentage of port bandwidth in use since last node, port or statistics reset. |
| STR cdx6500X25StatMaxPortUtilInTime | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.54 | DisplayString | read-only | Time stamp of Max percentage of port bandwidth in use since last node, port or statistics reset. |
| STR cdx6500X25StatMaxPortUtilOutTime | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.55 | DisplayString | read-only | Time stamp of Max percentage of port bandwidth in use since last node, port or statistics reset. |
| STR cdx6500X25StatMaxSVCCountTime | 1.3.6.1.4.1.449.2.1.3.1.1.2.1.56 | DisplayString | read-only | Time stamp of Maximum number of SVCs in use since last node, port or statistics reset. |
| cdx6500Controls | 1.3.6.1.4.1.449.2.1.4 |
RFC description
Defines optional configuration and operational objects for X.25 packet-switched network interfaces.
Start monitoring X.25 packet-switched network access devices/routers, e.g. cdx6500 platform (port-to-protocol-group config status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.