-- Version 2.15.1.2, modified 2001-10-20 11:29:03-04 X25-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, Gauge, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Codex MIB Group definitions codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500CfgGeneralGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 2 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 } -- Textual Conventions DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having SIZE (0..255) Counter16 ::= INTEGER (0..65535) -- X.25 Port Objects -- The 6500 X.25 Port Configuration Sub-group -- This sub-group belongs to the 6500 Port Protocol Configuration -- sub-group. It holds configuration parameters peculiar to the 6500 -- implementation of the X.25 protocol cdx6500PPCTX25PortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPCTX25PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of X.25 Port configuration entries." ::= { cdx6500PCTPortProtocolGroup 2 } cdx6500PPCTX25PortEntry OBJECT-TYPE SYNTAX Cdx6500PPCTX25PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An X.25 Configuration Table entry. Each entry contains the configuration parameters for a single X.25 port." INDEX { cdx6500X25CfgPortNumber } ::= { cdx6500PPCTX25PortTable 1 } Cdx6500PPCTX25PortEntry ::= SEQUENCE { cdx6500X25CfgPortNumber INTEGER, cdx6500X25CfgConnType INTEGER, cdx6500X25CfgPortCont DisplayString, cdx6500X25CfgClockSource INTEGER, cdx6500X25CfgClockSpeed INTEGER, cdx6500X25CfgAdmnInterfaceMode INTEGER, cdx6500X25CfgAdmnNumberPVCs INTEGER, cdx6500X25CfgStartPVCChanNum INTEGER, cdx6500X25CfgNumberSVCs INTEGER, cdx6500X25CfgStartSVCChanNum INTEGER, cdx6500X25CfgInitFrame DisplayString, cdx6500X25CfgT1RetryTimer INTEGER, cdx6500X25CfgT4PollTimer INTEGER, cdx6500X25CfgN2TransTries INTEGER, cdx6500X25CfgFrameSeqCounting INTEGER, cdx6500X25CfgKFrameWindow INTEGER, cdx6500X25CfgAdmnPacketSequencing INTEGER, cdx6500X25CfgWPacketWindow INTEGER, cdx6500X25CfgPPacketSize INTEGER, cdx6500X25CfgMaxNegotPacketSize INTEGER, cdx6500X25CfgDataQueueUpper INTEGER, cdx6500X25CfgDataQueueLower INTEGER, cdx6500X25CfgAdmnRestartTimer INTEGER, cdx6500X25CfgAdmnResetTimer INTEGER, cdx6500X25CfgAdmnCallTimer INTEGER, cdx6500X25CfgAdmnClearTimer INTEGER, cdx6500X25CfgOutDelFacilities DisplayString, cdx6500X25CfgOutAddFacilities DisplayString, cdx6500X25CfgOutBarFacilities DisplayString, cdx6500X25CfgInBarFacilities DisplayString, cdx6500X25CfgOptions DisplayString, cdx6500X25CfgNumRoutDigits INTEGER, cdx6500X25CfgPortDigitsToStrip INTEGER, cdx6500X25CfgInDigitsToStrip INTEGER, cdx6500X25CfgRestrictConn DisplayString, cdx6500X25CfgPortAddress DisplayString, cdx6500X25CfgCUGMember DisplayString, cdx6500X25CfgBillRec INTEGER, cdx6500X25CfgSubAddrSize INTEGER, cdx6500X25CfgIdleDiscTimer INTEGER, cdx6500X25CfgCallSecurity INTEGER, cdx6500X25CfgProtectLevel INTEGER, cdx6500X25CfgReconnTimeout INTEGER, cdx6500X25CfgReconnTriesLimit INTEGER, cdx6500X25CfgFacilSubscripCont DisplayString, cdx6500X25CfgAlarmPriority INTEGER, cdx6500X25CfgAddrTrans DisplayString, cdx6500X25CfgNumberInSVCs INTEGER, cdx6500X25CfgStartInSVCChanNum INTEGER, cdx6500X25CfgNumberOutSVCs INTEGER, cdx6500X25CfgStartOutSVCChanNum INTEGER, cdx6500X25CfgChargeInfoReq INTEGER, cdx6500X25CfgVerfnTimer INTEGER, cdx6500X25CfgValdFailures INTEGER, cdx6500X25CfgActionType INTEGER, cdx6500X25CfgLineIdleMode INTEGER, cdx6500X25CfgConfOption DisplayString, cdx6500X25CfgInvertTxClk INTEGER, cdx6500X25CfgDimType INTEGER, cdx6500X25CfgMoreOptions DisplayString, cdx6500X25CfgPsfFlag INTEGER, cdx6500X25CfgElectricalInterfaceType INTEGER, cdx6500X25CfgV24ElectricalInterfaceOption INTEGER, cdx6500X25CfgHighSpeedElectricalInterfaceOption INTEGER } cdx6500X25CfgPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Port number for this X.25 port." ::= { cdx6500PPCTX25PortEntry 1 } cdx6500X25CfgConnType OBJECT-TYPE SYNTAX INTEGER { simp (1), dtr (2), dtrd (3), emri (4), emdc (5), dimo (6), dimoa (7), dimob (8), dimov (11), simpv (12), simpb (21) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required. dtr - dedicated, require the data terminal ready signal (DTR). dtrd - same as DTR, except data set ready (DSR) drops between calls. dimo - port handshakes with attached dial modem dimoa - same as DIMO except DSR never raised on incoming call from modem. dimob - same as DIMO except DSR follows DTR on incoming call from modem. dimov - port handshakes with attached V.25 bis dial modem. emri - port emulates a dial modem with ring indicator (RI). emdc - port emulates a dial modem with data carrier detect (DCD). simpv - SIMP/DIMOv, modem will switch from Leased to Dial-only mode when leased line goes down (used with Link Backup only). simpb - simple, no control signals required for data transmission and reception. By default output leads will be low." ::= { cdx6500PPCTX25PortEntry 2 } cdx6500X25CfgPortCont OBJECT-TYPE SYNTAX DisplayString (SIZE(2..7)) ACCESS read-write STATUS mandatory DESCRIPTION "Specify any of the following port control options: NONE - no option specified. MB - raise Pin 22 when the port becomes disabled." ::= { cdx6500PPCTX25PortEntry 3 } cdx6500X25CfgClockSource OBJECT-TYPE SYNTAX INTEGER { int (1), ext (2), extint (3), extlp (4) } ACCESS read-write STATUS mandatory DESCRIPTION "int - internal clock source. ext - external clock source. extint - internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). extlp must be configured in conjunction with extint." ::= { cdx6500PPCTX25PortEntry 4 } cdx6500X25CfgClockSpeed OBJECT-TYPE SYNTAX INTEGER (1200..384000) ACCESS read-write STATUS mandatory DESCRIPTION "This is the speed of the port in bits per second, when using internal clocking. The highest available speed is dependant on the card type, and on the interface type. See the 6500 Series Configuration and Administration Manual for proper values." ::= { cdx6500PPCTX25PortEntry 5 } cdx6500X25CfgAdmnInterfaceMode OBJECT-TYPE SYNTAX INTEGER { dte (1), dce (2), negotiate (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The logical link address must be set to complementary values in devices at each end of the link: dte - link to have logical DTE address (A). dce - link to have logical DCE address (B). negotiate - link ends will negotiate which end is DCE address (B). This option is available only if the correct CSK is enabled." ::= { cdx6500PPCTX25PortEntry 6 } cdx6500X25CfgAdmnNumberPVCs OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-write STATUS mandatory DESCRIPTION "Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table." ::= { cdx6500PPCTX25PortEntry 7 } cdx6500X25CfgStartPVCChanNum OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This is the starting logical channel number for the Permanent Virtual Circuits on this link. Not used if the number of PVCs = 0." ::= { cdx6500PPCTX25PortEntry 8 } cdx6500X25CfgNumberSVCs OBJECT-TYPE SYNTAX INTEGER (0..512) ACCESS read-write STATUS mandatory DESCRIPTION "Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs." ::= { cdx6500PPCTX25PortEntry 9 } cdx6500X25CfgStartSVCChanNum OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This is the starting logical channel number for the Switched Virtual Circuits on this link. Not used if the number of SVCs = 0." ::= { cdx6500PPCTX25PortEntry 10 } cdx6500X25CfgInitFrame OBJECT-TYPE SYNTAX INTEGER { sabm (1), disc (2), none (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the initial frame required by other end for link startup: none - do nothing (other end initiates link-up). sabm - send SABM. disc - send DISC, then SABM." ::= { cdx6500PPCTX25PortEntry 11 } cdx6500X25CfgT1RetryTimer OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-write STATUS mandatory DESCRIPTION "T1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds)." ::= { cdx6500PPCTX25PortEntry 12 } cdx6500X25CfgT4PollTimer OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This sets the time an idle link is probed for assurance of connection to the remote device. 0 - disable the timer X - X is in tenths of a second (e.g. 40 = 4.0 seconds) and must be set greater than T1." ::= { cdx6500PPCTX25PortEntry 13 } cdx6500X25CfgN2TransTries OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of attempts allowed to complete a transmission." ::= { cdx6500PPCTX25PortEntry 14 } cdx6500X25CfgFrameSeqCounting OBJECT-TYPE SYNTAX INTEGER { norm (1), ext (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Port uses normal or extended frame sequence numbering norm - normal sequence counting (Modulo 8). ext - extended sequencing (Modulo 128)." ::= { cdx6500PPCTX25PortEntry 15 } cdx6500X25CfgKFrameWindow OBJECT-TYPE SYNTAX INTEGER (1..63) ACCESS read-write STATUS mandatory DESCRIPTION "Frame level window size must be set to the same value in devices at each end of the link." ::= { cdx6500PPCTX25PortEntry 16 } cdx6500X25CfgAdmnPacketSequencing OBJECT-TYPE SYNTAX INTEGER { norm (1), ext (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Port uses normal or extended packet level sequence numbers : norm - normal sequencing (Modulo 8). ext - extended sequencing (Modulo 128). The value must be the same in devices at each end of the link." ::= { cdx6500PPCTX25PortEntry 17 } cdx6500X25CfgWPacketWindow OBJECT-TYPE SYNTAX INTEGER (1..63) ACCESS read-write STATUS mandatory DESCRIPTION "Packet level window size must be set to the same value in devices at each end of the link." ::= { cdx6500PPCTX25PortEntry 18 } cdx6500X25CfgPPacketSize OBJECT-TYPE SYNTAX INTEGER { bytes128 (7), bytes256 (8), bytes512 (9), bytes1024 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum packet size used on X.25 links. For proper operation, the size must be the same in devices at each end of the link." ::= { cdx6500PPCTX25PortEntry 19 } cdx6500X25CfgMaxNegotPacketSize OBJECT-TYPE SYNTAX INTEGER { bytes128 (7), bytes256 (8), bytes512 (9), bytes1024 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum negotiated packet size allowed for inbound and outbound calls on this X.25 link." ::= { cdx6500PPCTX25PortEntry 20 } cdx6500X25CfgDataQueueUpper OBJECT-TYPE SYNTAX INTEGER (0..63) ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum number of data packets a channel on this port will queue for transmission before invoking flow control to the attached channel" ::= { cdx6500PPCTX25PortEntry 21 } cdx6500X25CfgDataQueueLower OBJECT-TYPE SYNTAX INTEGER (0..63) ACCESS read-write STATUS mandatory DESCRIPTION "This is the number of data packets a channel on this port will have queued for transmission when it releases flow control to the attached channel" ::= { cdx6500PPCTX25PortEntry 22 } cdx6500X25CfgAdmnRestartTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-write STATUS mandatory DESCRIPTION "Restart-Request timeout timer in seconds. If timer expires, request is sent again." ::= { cdx6500PPCTX25PortEntry 23 } cdx6500X25CfgAdmnResetTimer OBJECT-TYPE SYNTAX INTEGER (5..180) ACCESS read-write STATUS mandatory DESCRIPTION "Reset-Request timeout timer in seconds. If timer expires, request is sent again." ::= { cdx6500PPCTX25PortEntry 24 } cdx6500X25CfgAdmnCallTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-write STATUS mandatory DESCRIPTION "Call-Request timeout timer in seconds. If timer expires, call is cleared." ::= { cdx6500PPCTX25PortEntry 25 } cdx6500X25CfgAdmnClearTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-write STATUS mandatory DESCRIPTION "Clear-Request timeout timer in seconds. If timer expires, request is sent again." ::= { cdx6500PPCTX25PortEntry 26 } cdx6500X25CfgOutDelFacilities OBJECT-TYPE SYNTAX DisplayString (SIZE(3..17)) ACCESS read-write STATUS mandatory DESCRIPTION "Specify facilities deleted from an outbound call before it is forwarded: NONE - no facilities deleted. THRO - delete throughput class negotiation. NUI - delete network user identification. CUG - delete closed user group. Any combination of above specified by summing (e.g. THRO+NUI. . .)." ::= { cdx6500PPCTX25PortEntry 27 } cdx6500X25CfgOutAddFacilities OBJECT-TYPE SYNTAX DisplayString (SIZE(3..18)) ACCESS read-write STATUS mandatory DESCRIPTION "Specify facilities added to an outbound call before it is forwarded: NONE - no facilities added. REV - add reverse charging. PACK - add packet size negotiation. WIND - add window size negotiation. Any combination of above specified by summing (e.g. PACK+WIND+. . .)." ::= { cdx6500PPCTX25PortEntry 28 } cdx6500X25CfgOutBarFacilities OBJECT-TYPE SYNTAX DisplayString (SIZE(3..24)) ACCESS read-write STATUS mandatory DESCRIPTION "Specify facilities which, if present in an outbound call will be blocked by the port: NONE - no facility blocked. REV - bar reverse charging. FAST - bar fast select. BCUG - bar Bilateral Closed User Group. DGRAM - bar datagram. Any combination of above specified by summing (e.g. REV+FAST)." ::= { cdx6500PPCTX25PortEntry 29 } cdx6500X25CfgInBarFacilities OBJECT-TYPE SYNTAX DisplayString (SIZE(3..19)) ACCESS read-write STATUS mandatory DESCRIPTION "Specify facilities which, if present in an inbound call, will be blocked by the port: NONE - no facility blocked. BCUG - bar Bilateral Closed User Group. DGRAM - bar datagram. REV - bar Reverse Charging. Any combination of above specified by summing (e.g. DGRAM+BCUG)." ::= { cdx6500PPCTX25PortEntry 30 } cdx6500X25CfgOptions OBJECT-TYPE SYNTAX DisplayString (SIZE(3..107)) ACCESS read-write STATUS mandatory DESCRIPTION "Select options on this X.25 port as follows: NONE - no option specified. 1980 - use X.25 1980. NUI - perform network user identification validation check. PDN - connected to Public Data Network. CUD - use call user data subaddressing. IBAR - bar all calls coming in from X.25 port user. OBAR - bar all calls going out to X.25 port user. CBCK - allow routing inbound calls back out this port. CUG - check closed user group; otherwise, CUG passes transparently. CAUSE - pass cause, diagnostic, code in outbound packets. HOLD - hold calls over link restart. NRST - do not send restart packet on link-up. BKUP - this is a backup port to be activated if other ports are down. INL - inter-node link. Link goes to another Vanguard device.INL may be a poor choice for high speed links.INLB is set with INL to improve the performance of high speed links.INLB can be configured in the More X25 Options parameter. INLA - set with INL option when an X.25 link connection is to a 6500 node using 2.12.04 or earlier. DELAY - enable Delay and Path trace on this link (link must connected to Rel. 4.xx node). Any combination of above specified by summing (e.g. 1980+NUI+. . .)." ::= { cdx6500PPCTX25PortEntry 31 } cdx6500X25CfgNumRoutDigits OBJECT-TYPE SYNTAX INTEGER (0..12) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the number of routing digits in the call user data. It is used on X.25 links attached to a Public Data Network where the private network address is carried in the call user data." ::= { cdx6500PPCTX25PortEntry 32 } cdx6500X25CfgPortDigitsToStrip OBJECT-TYPE SYNTAX INTEGER (0..14) ACCESS read-write STATUS mandatory DESCRIPTION "For X.25 links connected to a Public Data Network, this parameter specifies the number of prefix digits to remove from the called address before forwarding the call to the PDN." ::= { cdx6500PPCTX25PortEntry 33 } cdx6500X25CfgInDigitsToStrip OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "For X.25 links connected to a Public Data Network, this parameter specifies the number of prefix digits to remove from the incoming calling address before forwarding the call from the PDN." ::= { cdx6500PPCTX25PortEntry 34 } cdx6500X25CfgRestrictConn OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "All calls entering this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. Blank this field to disable this function." ::= { cdx6500PPCTX25PortEntry 35 } cdx6500X25CfgPortAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "On X.25 links: If the X.25 Option REGO or REGI is selected, this address is inserted into the calling address field of the outbound or inbound call packet. On MUX links: When a MUX channel makes a call, the subaddress of the channel is appended to this address and inserted into the calling address field of the call packet." ::= { cdx6500PPCTX25PortEntry 36 } cdx6500X25CfgCUGMember OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) ACCESS read-write STATUS mandatory DESCRIPTION "The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except `--') and separated by a comma. ( e.g. 12,34,56,09,02,03 ). `--' - No CUG Membership. 00-99 - CUG Membership." ::= { cdx6500PPCTX25PortEntry 37 } cdx6500X25CfgBillRec OBJECT-TYPE SYNTAX INTEGER { off (1), on (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This controls whether billing (accounting) records will be created for calls on this port." ::= { cdx6500PPCTX25PortEntry 38 } cdx6500X25CfgSubAddrSize OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-write STATUS mandatory DESCRIPTION "For ports connected to a Public Data Network, this parameter specifies the number of digits in the subaddress of an X.25 address." ::= { cdx6500PPCTX25PortEntry 39 } cdx6500X25CfgIdleDiscTimer OBJECT-TYPE SYNTAX INTEGER (0..3200) ACCESS read-write STATUS mandatory DESCRIPTION "The time in seconds that the port must be idle (no calls) before being automatically disconnected. A value of 0 disables the Idle Disconnect feature. This feature may only be enabled on DIMO/DIMOa/DIMOb/DIMOv/SIMPv ports with the BKUP option selected." ::= { cdx6500PPCTX25PortEntry 40 } cdx6500X25CfgCallSecurity OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "For ports used as V.25 bis backup, this parameter specifies the type of call security to use prior to the link being detected up : disable - Disable will allow both incoming and outgoing calls. enable - Enable will allow ONLY outgoing calls. Incoming calls will be immediately terminated. This parameter is only used with Link Backup." ::= { cdx6500PPCTX25PortEntry 41 } cdx6500X25CfgProtectLevel OBJECT-TYPE SYNTAX INTEGER { none (1), cpOnly (2), fullDcp (3) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the level of data or connection protection which will be applied to calls to or from this port. The actual level for a call will be negotiated to the lesser of this level and the level configured for the other end of the call : none - No protection. cpOnly - Connection protection only. fullDcp - Full data and connection protection." ::= { cdx6500PPCTX25PortEntry 42 } cdx6500X25CfgReconnTimeout OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the number of seconds that DCP on the originating side will wait between reconnection attempts." ::= { cdx6500PPCTX25PortEntry 43 } cdx6500X25CfgReconnTriesLimit OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the number of times that DCP on the originating side will attempt to reconnect before clearing the call. If 0 is entered, it will not attempt to reconnect." ::= { cdx6500PPCTX25PortEntry 44 } cdx6500X25CfgFacilSubscripCont OBJECT-TYPE SYNTAX DisplayString (SIZE(4..34)) ACCESS read-only STATUS mandatory DESCRIPTION "NONE - Subscription to facilities not enforced. FCN-ON - Flow Control Negotiation enabled. Packet and Window size negotiation facilities in an inbound call will be allowed. Packet and Window size facilities will always be included in outbound calls and call accepted/ connected when this parameter is set. FCN-OFF - Flow Control Negotiation disabled. Inbound calls containing Packet and Window size facilities will be cleared. Packet and Window size facilities will not be present in outbound calls and call accepted/ connected when this parameter is set. TCN-ON - Throughput Class Negotiation enabled. The throughput class negotiation facility in an inbound call will be allowed. The throughput class negotiation facility will always be included in outbound calls and call accepted/connected when this parameter is set. The facility is passed onward to the destination in the call packet transparently and does not alter the handling of the SVC data within the node. TCN-OFF - Throughput Class Negotiation disabled. Inbound calls containing the throughput class negotiation facility will be cleared. The throughput class negotiation facility will not be present in outbound calls and call accepted/connected when this parameter is set. Some combinations of above options are allowed (e.g. FCN-ON+TCN-ON)." ::= { cdx6500PPCTX25PortEntry 45 } cdx6500X25CfgAlarmPriority OBJECT-TYPE SYNTAX INTEGER { network (1), access (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the severity level of LINK UP and LINK DOWN alarms : network - Severity HIGH alarms will be generated. access - Severity LOW alarms will be generated." ::= { cdx6500PPCTX25PortEntry 46 } cdx6500X25CfgAddrTrans OBJECT-TYPE SYNTAX DisplayString (SIZE(3..107)) ACCESS read-write STATUS mandatory DESCRIPTION "Select any of the following address translation options NONE - no option specified Outbound Call Processing: DEDO - delete called address. DEGO - delete calling address. REGO - replace calling address with configured Port Address. REGSO - replace calling address with configured Port Address plus Inbound Subaddress obtained from the Inbound Call Translation Table entry where Private Network Address matches the entire calling address. INGO - replace calling address with configured Port Address and retain original calling subaddress. SAGO - strip calling address, but retain subaddress. Inbound Call Processing: INGI - replace calling address with configured Port Address and retain original calling subaddress. REGI - replace calling address with configured Port Address. SRGI - select route from the Calling Address Translation Table by replacing the called address with the Private Network Address where the Inbound Calling Address matches the beginning of the calling address. Call Accept Processing: DADA - delete called address in inbound/outbound call accept. DAGA - delete calling address in inbound/outbound call accept. IADD - copy called and calling addresses from call request into outbound call accepted/connected. Some of the options may be combined (e.g. DEDO+DEGO+...)" ::= { cdx6500PPCTX25PortEntry 47 } cdx6500X25CfgNumberInSVCs OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "Number of logical channels used in One Way Incoming Switched Virtual Circuits. The total number of PVC, One Way Incoming, One Way Outgoing and Two Way SVC channels should be kept as small as possible and consistent with needs." ::= { cdx6500PPCTX25PortEntry 48 } cdx6500X25CfgStartInSVCChanNum OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This is the starting logical channel number for the One Way Incoming Switched Virtual Circuits on this link. Not used if the number of One Way Incoming SVCs = 0." ::= { cdx6500PPCTX25PortEntry 49 } cdx6500X25CfgNumberOutSVCs OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "Number of logical channels used in One Way Outgoing Switched Virtual Circuits. The total number of PVC, One Way Outgoing, One Way Outgoing and Two Way SVC channels should be kept as small as possible and consistent with needs." ::= { cdx6500PPCTX25PortEntry 50 } cdx6500X25CfgStartOutSVCChanNum OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This is the starting logical channel number for the One Way Outgoing Switched Virtual Circuits on this link. Not used if the number of One Way Outgoing SVCs = 0." ::= { cdx6500PPCTX25PortEntry 51 } cdx6500X25CfgChargeInfoReq OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies whether Charging Information has to be sent even without requesting." ::= { cdx6500PPCTX25PortEntry 52 } cdx6500X25CfgVerfnTimer OBJECT-TYPE SYNTAX INTEGER (5..180) ACCESS read-write STATUS mandatory DESCRIPTION "Specify the NUI verification timer in seconds. The call is cleared if timer expires." ::= { cdx6500PPCTX25PortEntry 53 } cdx6500X25CfgValdFailures OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of successive NUI verification failures an X.25 DTE can tolerate when making verification attempts timer expires." ::= { cdx6500PPCTX25PortEntry 54 } cdx6500X25CfgActionType OBJECT-TYPE SYNTAX INTEGER { none (1), disc (2), degr (3), lock (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the course of action to be taken if the NUI violations exceed the configured threshold count. This parameter is effective only if the X25 options parameter is set to CNUI NONE - No action is taken. DISC - All connections on the port are broken. DEGR - Port is busied-out for one minute then it is re-enabled. LOCK - All connections on the port are broken and the port is disabled." ::= { cdx6500PPCTX25PortEntry 55 } cdx6500X25CfgLineIdleMode OBJECT-TYPE SYNTAX INTEGER { flag (1), mark (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify any of the following line idle mode options: FLAG - Flag fill between frames MARK - Mark idle between frames" ::= { cdx6500PPCTX25PortEntry 56 } cdx6500X25CfgConfOption OBJECT-TYPE SYNTAX DisplayString (SIZE(4..34)) ACCESS read-write STATUS mandatory DESCRIPTION "Select any of the following conformance control options: NONE - no option specified CHKFAC - Checking of facility codes enabled." ::= { cdx6500PPCTX25PortEntry 57 } cdx6500X25CfgInvertTxClk OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies whether the phase of the transmit clock should be inverted. NO - Don't invert YES - Invert" ::= { cdx6500PPCTX25PortEntry 58 } cdx6500X25CfgDimType OBJECT-TYPE SYNTAX INTEGER { dim-type-none (1), dim-type-not-installed (2), dim-type-eia-232-d (3), dim-type-x21 (4), dim-type-v35 (5), dim-type-v36 (6), dim-type-v11 (7), dim-type-eia-530 (8), dim-type-dsu (9), dim-type-isdn (10), dim-type-vrdc (11), dim-type-i430 (12), dim-type-vrdc-2fxs (13), dim-type-t1e1 (14), dim-type-future-use (15), dim-not-supported (16), dim-type-vrdc-2em (17), dim-type-vrdc-bri (18) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the physical interface type to be used for this port: V.36 - V.36 physical interface EIA-530A - EIA-530A physical interface V.35 - V.35 physical interface X.21 - X.21 physical interface RS-449 - RS-449 physical interface EIA-530 - EIA-530 physical interface RS-232 - RS-232 physical interface" ::= { cdx6500PPCTX25PortEntry 59 } cdx6500X25CfgMoreOptions OBJECT-TYPE SYNTAX DisplayString (SIZE(4..9)) ACCESS read-write STATUS mandatory DESCRIPTION "Select more options on this X.25 port as follows: NONE - no option specified INLB - set with INL option to improve performance if inter-node link is a high speed link" ::= { cdx6500PPCTX25PortEntry 60 } cdx6500X25CfgPsfFlag OBJECT-TYPE SYNTAX INTEGER { psf-disabled (1), psf-enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION " Enable or Disable Port Selection Facility feature. Used to control access to ports for Select user group applications." ::= { cdx6500PPCTX25PortEntry 61 } cdx6500X25CfgElectricalInterfaceType OBJECT-TYPE SYNTAX INTEGER { v24 (1), v35 (2), v36 (3), x21 (4), none (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled" ::= { cdx6500PPCTX25PortEntry 62 } cdx6500X25CfgV24ElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { ri (1), tm (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal" ::= { cdx6500PPCTX25PortEntry 63 } cdx6500X25CfgHighSpeedElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { none (1), xover (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable" ::= { cdx6500PPCTX25PortEntry 64 } -- The 6500 X.25 Port Statistics Sub-group -- This sub-group belongs to the 6500 Port Protocol Statistics -- group. It holds statistics peculiar to the 6500 -- implementation of the x.25 protocol cdx6500PPSTX25PortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTX25PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of X.25 Port statistics." ::= { cdx6500PSTPortProtocolGroup 2 } cdx6500PPSTX25PortEntry OBJECT-TYPE SYNTAX Cdx6500PPSTX25PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An X.25 Statistics Table entry. Each entry contains the statistics for a single X.25 port." INDEX { cdx6500X25StatPortNumber } ::= { cdx6500PPSTX25PortTable 1 } Cdx6500PPSTX25PortEntry ::= SEQUENCE { cdx6500X25StatPortNumber INTEGER, cdx6500X25StatPortStatus DisplayString, cdx6500X25StatPortState INTEGER, cdx6500X25StatActualPortSpeed INTEGER, cdx6500X25StatPortUtilIn INTEGER, cdx6500X25StatPortUtilOut INTEGER, cdx6500X25StatMaxSVCCount Gauge, cdx6500X25StatCurrSVCCount INTEGER, cdx6500X25StatInChars Counter, cdx6500X25StatOutChars Counter, cdx6500X25StatInPkts Counter, cdx6500X25StatOutPkts Counter, cdx6500X25StatInDataFrames Counter, cdx6500X25StatOutDataFrames Counter, cdx6500X25StatNumPktsQueued INTEGER, cdx6500X25StatCharRateIn INTEGER, cdx6500X25StatCharRateOut INTEGER, cdx6500X25StatPktRateIn INTEGER, cdx6500X25StatPktRateOut INTEGER, cdx6500X25StatFrameRateIn INTEGER, cdx6500X25StatFrameRateOut INTEGER, cdx6500X25StatOverrunErrs Counter16, cdx6500X25StatUnderrunErrs Counter16, cdx6500X25StatCRCErrs Counter16, cdx6500X25StatInInfoFrames Counter, cdx6500X25StatOutInfoFrames Counter, cdx6500X25StatInRNRFrames Counter, cdx6500X25StatOutRNRFrames Counter, cdx6500X25StatInRRFrames Counter, cdx6500X25StatOutRRFrames Counter, cdx6500X25StatInREJFrames Counter, cdx6500X25StatOutREJFrames Counter, cdx6500X25StatInDataPkts Counter, cdx6500X25StatOutDataPkts Counter, cdx6500X25StatNumRxCallsSinceLastReset INTEGER, cdx6500X25StatNumRxCallsRejected INTEGER, cdx6500X25StatRxLastCallFailureCause INTEGER, cdx6500X25StatRxLastCalledNumber DisplayString, cdx6500X25StatRxLastCallingNumber DisplayString, cdx6500X25StatRxMinCallDuration DisplayString, cdx6500X25StatRxMaxCallDuration DisplayString, cdx6500X25StatRxAvgCallDuration DisplayString, cdx6500X25StatNumTxCallsSinceLastReset INTEGER, cdx6500X25StatNumTxCallsRejected INTEGER, cdx6500X25StatTxLastCallFailureCause INTEGER, cdx6500X25StatTxLastCalledNumber DisplayString, cdx6500X25StatTxLastCallingNumber DisplayString, cdx6500X25StatTxMinCallDuration DisplayString, cdx6500X25StatTxMaxCallDuration DisplayString, cdx6500X25StatTxAvgCallDuration DisplayString, cdx6500X25StatSignalingState INTEGER, cdx6500X25StatMaxPortUtilIn INTEGER, cdx6500X25StatMaxPortUtilOut INTEGER, cdx6500X25StatMaxPortUtilInTime DisplayString, cdx6500X25StatMaxPortUtilOutTime DisplayString, cdx6500X25StatMaxSVCCountTime DisplayString } cdx6500X25StatPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The port number for this X.25 port." ::= { cdx6500PPSTX25PortEntry 1 } cdx6500X25StatPortStatus OBJECT-TYPE SYNTAX DisplayString (SIZE(2..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Status of this port : Up - Port is active Down - Port Is inactive Disabled - An operator has disabled the port Busy Out - an operator has busied out the port" ::= { cdx6500PPSTX25PortEntry 2 } cdx6500X25StatPortState OBJECT-TYPE SYNTAX INTEGER { discPhase (1), linkDisk (2), linkSetup (3), sabmColl (4), frameReject (5), normal (6), remoteBusy (7), reset (8), sendReject (9), rbSr (10) } ACCESS read-only STATUS mandatory DESCRIPTION "discPhase - Disconnect Phase. linkDisk - Link Disconnect. linkSetup - The port is sending SABM frames and waiting for a UA response. sabmColl - SABM Collision. frameReject - The port has rejected a received frame. normal - The port sending/receiving data. remoteBusy - The port is receiving RNR frames. reset - The port is being reset. sendRej - The port is sending REJ frames. rbSr - The port is receiving RNR frames and sending REJ frames." ::= { cdx6500PPSTX25PortEntry 3 } cdx6500X25StatActualPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the speed of the port when Clock = INT; this is the detected clock speed if Clock = EXT. If Port Speed is 0, Clock = EXT, but clocking is not being received fom attatched device." ::= { cdx6500PPSTX25PortEntry 4 } cdx6500X25StatPortUtilIn OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Percentage of port bandwidth in use." ::= { cdx6500PPSTX25PortEntry 5 } cdx6500X25StatPortUtilOut OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Percentage of port bandwidth in use." ::= { cdx6500PPSTX25PortEntry 6 } cdx6500X25StatMaxSVCCount OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of SVCs in use since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 7 } cdx6500X25StatCurrSVCCount OBJECT-TYPE SYNTAX INTEGER (0..2000) ACCESS read-only STATUS mandatory DESCRIPTION "Current number of SVCs in use." ::= { cdx6500PPSTX25PortEntry 8 } cdx6500X25StatInChars OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 9 } cdx6500X25StatOutChars OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters sent since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 10 } cdx6500X25StatInPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets received since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 11 } cdx6500X25StatOutPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets sent since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 12 } cdx6500X25StatInDataFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 13 } cdx6500X25StatOutDataFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 14 } cdx6500X25StatNumPktsQueued OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets currently queued." ::= { cdx6500PPSTX25PortEntry 15 } cdx6500X25StatCharRateIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the characters being received by the port." ::= { cdx6500PPSTX25PortEntry 16 } cdx6500X25StatCharRateOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the characters being sent by the port." ::= { cdx6500PPSTX25PortEntry 17 } cdx6500X25StatPktRateIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the packets being received by the port." ::= { cdx6500PPSTX25PortEntry 18 } cdx6500X25StatPktRateOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the packets being sent by the port." ::= { cdx6500PPSTX25PortEntry 19 } cdx6500X25StatFrameRateIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the frames being received by the port." ::= { cdx6500PPSTX25PortEntry 20 } cdx6500X25StatFrameRateOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the frames being sent by the port." ::= { cdx6500PPSTX25PortEntry 21 } cdx6500X25StatOverrunErrs OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of Overrun errors since the last node or statistics reset." ::= { cdx6500PPSTX25PortEntry 22 } cdx6500X25StatUnderrunErrs OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of Underrun errors since the last node or statistics reset." ::= { cdx6500PPSTX25PortEntry 23 } cdx6500X25StatCRCErrs OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of CRC errors since the last node or statistics reset." ::= { cdx6500PPSTX25PortEntry 24 } cdx6500X25StatInInfoFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Info frames received since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 25 } cdx6500X25StatOutInfoFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Info frames sent since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 26 } cdx6500X25StatInRNRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received since last node, port or statistics reset indicating RNR." ::= { cdx6500PPSTX25PortEntry 27 } cdx6500X25StatOutRNRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent since last node, port or statistics reset indicating RNR." ::= { cdx6500PPSTX25PortEntry 28 } cdx6500X25StatInRRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received since last node, port or statistics reset indicating RR." ::= { cdx6500PPSTX25PortEntry 29 } cdx6500X25StatOutRRFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent since last node, port or statistics reset indicating RR." ::= { cdx6500PPSTX25PortEntry 30 } cdx6500X25StatInREJFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received since last node, port or statistics reset indicating REJ." ::= { cdx6500PPSTX25PortEntry 31 } cdx6500X25StatOutREJFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent since last node, port or statistics reset indicating REJ." ::= { cdx6500PPSTX25PortEntry 32 } cdx6500X25StatInDataPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of data packets received since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 33 } cdx6500X25StatOutDataPkts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of data packets sent since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 34 } -- ISDN Call Status related statistics : these statistics -- are only valid for (virtual) switched data ports. cdx6500X25StatNumRxCallsSinceLastReset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound calls that were attempted since the last statistics reset." ::= { cdx6500PPSTX25PortEntry 35 } cdx6500X25StatNumRxCallsRejected OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound calls that were rejected since the last statistics reset." ::= { cdx6500PPSTX25PortEntry 36 } cdx6500X25StatRxLastCallFailureCause OBJECT-TYPE SYNTAX INTEGER { notAvailable (100), noFailureReported (193), noAvailableVirtualPort (194), securityViolation (195), noResourcesAvailable (196), callRejected (197), invalidPhoneNumber (198), outgoingCallRequestTimeout (199), callCollision (200), virtualPortNotAvailable (201), invalidConfiguration (202), failureNotSupported (203) } ACCESS read-only STATUS mandatory DESCRIPTION "The reason the last inbound call was rejected, since the last statistics reset. The posssible values are: notAvailable : Value not available if not a (virtual) switched data port. noFailureReported : No call failure noAvailableVirtualPort : No virtual port available securityViolation : Password security failed noResourcesAvailable : No resources available callRejected : Call failed by Xircom card invalidPhoneNumber : Phone number is incorrect outgoingCallRequestTimeout : Outgoing call req timeout callCollision : Call collision virtualPortNotAvailable : This port is not available invalidConfiguration : Configuration is incorrect failureNotSupported : Failure is not supported" ::= { cdx6500PPSTX25PortEntry 37 } cdx6500X25StatRxLastCalledNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "The phone number of the virtual port of the last ISDN call made into this port." ::= { cdx6500PPSTX25PortEntry 38 } cdx6500X25StatRxLastCallingNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "The phone number of last party to make an ISDN call into this port." ::= { cdx6500PPSTX25PortEntry 39 } cdx6500X25StatRxMinCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The minimum call duration of all inbound ISDN calls made into this port, since the last statistics reset." ::= { cdx6500PPSTX25PortEntry 40 } cdx6500X25StatRxMaxCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The maximum call duration of all inbound ISDN calls made into this port, since the last statistics reset." ::= { cdx6500PPSTX25PortEntry 41 } cdx6500X25StatRxAvgCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The average call duration of all inbound ISDN calls made into this port, since the last statistics reset." ::= { cdx6500PPSTX25PortEntry 42 } cdx6500X25StatNumTxCallsSinceLastReset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound calls that were attempted since the last statistics reset." ::= { cdx6500PPSTX25PortEntry 43 } cdx6500X25StatNumTxCallsRejected OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound calls that were rejected since the last statistics reset." ::= { cdx6500PPSTX25PortEntry 44 } cdx6500X25StatTxLastCallFailureCause OBJECT-TYPE SYNTAX INTEGER { notAvailable (100), noFailureReported (193), noAvailableVirtualPort (194), securityViolation (195), noResourcesAvailable (196), callRejected (197), invalidPhoneNumber (198), outgoingCallRequestTimeout (199), callCollision (200), virtualPortNotAvailable (201), invalidConfiguration (202), failureNotSupported (203) } ACCESS read-only STATUS mandatory DESCRIPTION "The reason the last inbound call was rejected, since the last statistics reset. The posssible values are: notAvailable : Value not available if not a (virtual) switched data port. noFailureReported : No call failure noAvailableVirtualPort : No virtual port available securityViolation : Password security failed noResourcesAvailable : No resources available callRejected : Call failed by Xircom card invalidPhoneNumber : Phone number is incorrect outgoingCallRequestTimeout : Outgoing call req timeout callCollision : Call collision virtualPortNotAvailable : This port is not available invalidConfiguration : Configuration is incorrect failureNotSupported : Failure is not supported" ::= { cdx6500PPSTX25PortEntry 45 } cdx6500X25StatTxLastCalledNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "The phone number of the last ISDN call made by a virtual port from this port." ::= { cdx6500PPSTX25PortEntry 46 } cdx6500X25StatTxLastCallingNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-only STATUS mandatory DESCRIPTION "The phone number of the virtual port that made the last ISDN call from this port." ::= { cdx6500PPSTX25PortEntry 47 } cdx6500X25StatTxMinCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The minimum call duration of all outbound ISDN calls made from this port, since the last statistics reset." ::= { cdx6500PPSTX25PortEntry 48 } cdx6500X25StatTxMaxCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The maximum call duration of all outbound ISDN calls made from this port, since the last statistics reset." ::= { cdx6500PPSTX25PortEntry 49 } cdx6500X25StatTxAvgCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The average call duration of all outbound ISDN calls made from this port, since the last statistics reset." ::= { cdx6500PPSTX25PortEntry 50 } cdx6500X25StatSignalingState OBJECT-TYPE SYNTAX INTEGER { idle (1), ringing (2), connected (3), congested (4), disabled (5), dChannelDown (6), disabledDChannelDown (7), disconnecting (8), notAvailable (100) } ACCESS read-only STATUS mandatory DESCRIPTION "ISDN call signaling state. The possible values are: idle : No ISDN call present. ringing : Pending outgoing ISDN call request. connected : ISDN call is connected. congested : Congested mode. disabled : Virtual Port is disabled. dChannelDown : D-channel is down. disabledChannelDown : Disable and D-channel is down. disconnecting : Pending ISDN call disconnection. notAvailable : Value not available if not a (virtual) switched data port." ::= { cdx6500PPSTX25PortEntry 51 } cdx6500X25StatMaxPortUtilIn OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Max percentage of port bandwidth in use since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 52 } cdx6500X25StatMaxPortUtilOut OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Max percentage of port bandwidth in use since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 53 } cdx6500X25StatMaxPortUtilInTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of Max percentage of port bandwidth in use since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 54 } cdx6500X25StatMaxPortUtilOutTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of Max percentage of port bandwidth in use since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 55 } cdx6500X25StatMaxSVCCountTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of Maximum number of SVCs in use since last node, port or statistics reset." ::= { cdx6500PPSTX25PortEntry 56 } -- This Table contains Configuration paramaters -- for the Inbound Call Translation table. cdx6500CGTInboundCallTranTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500CGTInboundCallTranEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Inbound Call Translation table." ::= { cdx6500CfgGeneralGroup 2 } cdx6500CGTInboundCallTranEntry OBJECT-TYPE SYNTAX Cdx6500CGTInboundCallTranEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Inbound Call Translation configuration parameters." INDEX { cdx6500InCallTranEntryNum } ::= { cdx6500CGTInboundCallTranTable 1 } Cdx6500CGTInboundCallTranEntry ::= SEQUENCE { cdx6500InCallTranEntryNum INTEGER, cdx6500InCallTranInSubAddr DisplayString, cdx6500InCallTranPrivNetAddr DisplayString } cdx6500InCallTranEntryNum OBJECT-TYPE SYNTAX INTEGER (1..1000) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configuration parameter. Instead, it identifies the particular Inbound Call Translation Table entry being configured by the other parameters in the record." ::= { cdx6500CGTInboundCallTranEntry 1 } cdx6500InCallTranInSubAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the subaddress contained in an inbound call from another network, usually a public data network (PDN). It will be translated into a private network address before the call is forwarded." ::= { cdx6500CGTInboundCallTranEntry 2 } cdx6500InCallTranPrivNetAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the private network address to translate to, before forwarding calls from a PDN." ::= { cdx6500CGTInboundCallTranEntry 3 } -- The Outbound Call Translation Configuration Table -- This table contains Configuration paramaters -- for the Outbound Call Translation table. cdx6500CGTOutboundCallTranTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500CGTOutboundCallTranEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Outbound Call Translation table." ::= { cdx6500CfgGeneralGroup 3 } cdx6500CGTOutboundCallTranEntry OBJECT-TYPE SYNTAX Cdx6500CGTOutboundCallTranEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Outbound Call Translation configuration parameters." INDEX { cdx6500OutCallTranEntryNum } ::= { cdx6500CGTOutboundCallTranTable 1 } Cdx6500CGTOutboundCallTranEntry ::= SEQUENCE { cdx6500OutCallTranEntryNum INTEGER, cdx6500OutCallTranPrivNetAddr DisplayString, cdx6500OutCallTranOutNetAddr DisplayString, cdx6500OutCallTranOptions INTEGER } cdx6500OutCallTranEntryNum OBJECT-TYPE SYNTAX INTEGER (1..1600) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configuration parameter. Instead, it identifies the particular Outbound Call Translation Table entry being configured by the other parameters in the record." ::= { cdx6500CGTOutboundCallTranEntry 1 } cdx6500OutCallTranPrivNetAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the private network address contained in an outbound call to another network, usually a public data network (PDN). It will be translated into a PDN address before the call is forwarded." ::= { cdx6500CGTOutboundCallTranEntry 2 } cdx6500OutCallTranOutNetAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the public network address to translate to, before forwarding calls to a PDN." ::= { cdx6500CGTOutboundCallTranEntry 3 } cdx6500OutCallTranOptions OBJECT-TYPE SYNTAX INTEGER { none (0), olda (1), newvalNone (50) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies options for outbound call address translation as follows: olda - insert the original called address into outbound call user data. newvalNone - same functionality as 'none', new enumeration added for RFC1155 compatibility." ::= { cdx6500CGTOutboundCallTranEntry 4 } -- The Calling Address Translation Configuration Table -- This table contains Configuration paramaters -- for the Calling Address Translation table. cdx6500CGTCallingAddrTranTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500CGTCallingAddrTranEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Calling AddressTranslation table." ::= { cdx6500CfgGeneralGroup 13 } cdx6500CGTCallingAddrTranEntry OBJECT-TYPE SYNTAX Cdx6500CGTCallingAddrTranEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Calling Address Translation configuration parameters." INDEX { cdx6500CalladdrtranEntryNum } ::= { cdx6500CGTCallingAddrTranTable 1 } Cdx6500CGTCallingAddrTranEntry ::= SEQUENCE { cdx6500CalladdrtranEntryNum INTEGER, cdx6500CalladdrtranInCallAddr DisplayString, cdx6500CalladdrtranPrivNetAddr DisplayString } cdx6500CalladdrtranEntryNum OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configuration parameter. Instead, it identifies the entry being configured by the other parameters in the record." ::= { cdx6500CGTCallingAddrTranEntry 1 } cdx6500CalladdrtranInCallAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the calling address contained in an inbound call, it will be translated into a private network address (if a match is found in the Translation Table), before the call is forwarded." ::= { cdx6500CGTCallingAddrTranEntry 2 } cdx6500CalladdrtranPrivNetAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the private network address to translate to, before forwarding the call." ::= { cdx6500CGTCallingAddrTranEntry 3 } -- The CUD Base Address Translation Configuration Table -- This table contains Configuration paramaters -- for the CUD Base Address Translation table. cdx6500CGTCudBaseAddrTranTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500CGTCudBaseAddrTranEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the CUD Base AddressTranslation table." ::= { cdx6500CfgGeneralGroup 23 } cdx6500CGTCudBaseAddrTranEntry OBJECT-TYPE SYNTAX Cdx6500CGTCudBaseAddrTranEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of CUD Base Address Translation configuration parameters." INDEX { cdx6500CudBaseaddrtranEntryNum } ::= { cdx6500CGTCudBaseAddrTranTable 1 } Cdx6500CGTCudBaseAddrTranEntry ::= SEQUENCE { cdx6500CudBaseaddrtranEntryNum INTEGER, cdx6500CudBaseStr DisplayString, cdx6500CudBaseAddr DisplayString } cdx6500CudBaseaddrtranEntryNum OBJECT-TYPE SYNTAX INTEGER (1..64) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configuration parameter. Instead, it identifies the entry being configured by the other parameters in the record." ::= { cdx6500CGTCudBaseAddrTranEntry 1 } cdx6500CudBaseStr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Enter the sub-string to search in the CUD for the incoming call for translating it into Called address. For searching from index in the CUD the name can be specified as (7)DADADIFUBBBB, it will skip 7 characters of the CUD and match DADAIFUBBBB in the CUD starting at Position 8." ::= { cdx6500CGTCudBaseAddrTranEntry 2 } cdx6500CudBaseAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "Enter the X.25 Address which will be inserted for called address of incoming X.25 call packet if the configured CUD string is matched in the CUD of the incoming X.25 Call packet." ::= { cdx6500CGTCudBaseAddrTranEntry 3 } END