| OID symbolic | OID numeric | Type | Access | Description |
| wfFrDlcmiTable | 1.3.6.1.4.1.18.3.5.9.1.1 | | not-accessible | The Parameters for the Data Link Connection Management Interface |
| wfFrDlcmiEntry | 1.3.6.1.4.1.18.3.5.9.1.1.1 | | not-accessible | The parameters for a particular Data Link Connection Management Interface |
| INT wfFr1DlcmiDelete | 1.3.6.1.4.1.18.3.5.9.1.1.1.1 | INTEGER | read-write | Indication to delete this frame relay interface |
| INT wfFr1DlcmiDisable | 1.3.6.1.4.1.18.3.5.9.1.1.1.2 | INTEGER | read-write | Indicates when a dlcmi entry is to be enabled or disabled. |
| INT wfFr1DlcmiState | 1.3.6.1.4.1.18.3.5.9.1.1.1.3 | INTEGER | read-only | The current state of Frame Relay. The not present state is not actually
valid except when the record is first added. It is included for
consistency. |
| INT wfFr1DlcmiCircuit | 1.3.6.1.4.1.18.3.5.9.1.1.1.4 | INTEGER | read-only | Instance identifier. The circuit number of this entry |
| INT wfFr1DlcmiManagementType | 1.3.6.1.4.1.18.3.5.9.1.1.1.5 | INTEGER | read-write | This variable indicates which Data Link Connection Management
scheme is active (and by implication, what DLCI it uses). |
| INT wfFr1DlcmiStatus | 1.3.6.1.4.1.18.3.5.9.1.1.1.6 | INTEGER | read-only | Indicates the status of the interface.
FR1_STATUS_START is the state during rebooting or initial
start of circuit
FR1_STATUS_RUNNING1 is the sate after the circuit is up (either LMI
successful or there is no DLCMI and the system just comes up).
FR1_STATUS_FAULT is a transient state indicating that errors have
caused the circuit to be disabled until DLCMI recovery.
FR1_STATUS_RECOVERED indicates that an the system has been in the
FR_STATUS_FAULT mode before, but has since recovered. |
| INT wfFr1DlcmiAddress | 1.3.6.1.4.1.18.3.5.9.1.1.1.7 | INTEGER | read-write | This states which address format is in use on the FR interface.
The default is Q922 |
| INT wfFr1DlcmiAddressLen | 1.3.6.1.4.1.18.3.5.9.1.1.1.8 | INTEGER | read-write | This variable states the address length in octets. In the case
of Q922 format, the length indicates the entire length of the
address includeding the control portion. |
| INT wfFr1DlcmiPollingInterval | 1.3.6.1.4.1.18.3.5.9.1.1.1.9 | INTEGER | read-write | The number of seconds between successive status enquiry messages |
| INT wfFr1DlcmiFullEnquiryInterval | 1.3.6.1.4.1.18.3.5.9.1.1.1.10 | INTEGER | read-write | The number of status enquiry intervals that pass before issuance
of a full status enquiry message. |
| INT wfFr1DlcmiErrorThreshold | 1.3.6.1.4.1.18.3.5.9.1.1.1.11 | INTEGER | read-write | This is the maximum number of unanswered Status Enquiries the
equipment shall accept before declaring the interface down. |
| INT wfFr1DlcmiMonitoredEvents | 1.3.6.1.4.1.18.3.5.9.1.1.1.12 | INTEGER | read-write | This is the number of status polling intervals over
which the error threshold is counted. For example, if
within 'MonitoredEvents' number of events the station
receives 'ErrorThreshold' number of errors, the
interface is marked as down. |
| INT wfFr1DlcmiMaxSupportedVCs | 1.3.6.1.4.1.18.3.5.9.1.1.1.13 | INTEGER | read-only | The maximum number of Virtual Circuits allowed for
this interface. Usually dictated by the Frame Relay
network. The system sets this initially. |
| INT wfFr1DlcmiMulticast | 1.3.6.1.4.1.18.3.5.9.1.1.1.14 | INTEGER | read-write | This indicates whether the frame relay provider offers a multicast |
| INT wfFr1DlcmiSeqCount | 1.3.6.1.4.1.18.3.5.9.1.1.1.15 | INTEGER | read-only | This station's sequence counter. It represents the next
value to send. |
| INT wfFr1DlcmiLastReceived | 1.3.6.1.4.1.18.3.5.9.1.1.1.16 | INTEGER | read-only | The sequence number just received from the switch. |
| INT wfFr1DlcmiPassiveSeqCount | 1.3.6.1.4.1.18.3.5.9.1.1.1.17 | INTEGER | read-only | This station's sequence counter for answering status enquiry. |
| INT wfFr1DlcmiPassiveReceived | 1.3.6.1.4.1.18.3.5.9.1.1.1.18 | INTEGER | read-only | The sequence number just received from the enquring station. |
| INT wfFr1DlcmiPolls | 1.3.6.1.4.1.18.3.5.9.1.1.1.19 | INTEGER | read-only | This is the counter of where we are in the polling cycle. |
| INT wfFr1DlcmiAlarmTimer | 1.3.6.1.4.1.18.3.5.9.1.1.1.20 | INTEGER | read-only | This is a counter of 1/2 second timeouts. When it reaches
2 x the polling interval, an enquiry message is sent. |
| INT wfFr1ErrType | 1.3.6.1.4.1.18.3.5.9.1.1.1.21 | INTEGER | read-only | Indicate the type of the last specific monitored error. |
| OCT wfFr1ErrData | 1.3.6.1.4.1.18.3.5.9.1.1.1.22 | OCTET STRING | read-only | Contains as much of the error packet as possible. |
| TIK wfFr1ErrTime | 1.3.6.1.4.1.18.3.5.9.1.1.1.23 | TimeTicks | read-only | The time the last error occurred. |
| CTR wfFr1ErrDiscards | 1.3.6.1.4.1.18.3.5.9.1.1.1.24 | Counter | read-only | The number of inbound frames dropped because of format or other
errors or because the VC was not known. |
| CTR wfFr1ErrDrops | 1.3.6.1.4.1.18.3.5.9.1.1.1.25 | Counter | read-only | The number of outbound frames dropped. Usually this is due the
specified DLCI being unknown or a broadcast packet is too long |
| wfFrCircuitTable | 1.3.6.1.4.1.18.3.5.9.1.2 | | not-accessible | Frame Relay Circuit table gives information about a virtual circuits. |
| wfFrCircuitEntry | 1.3.6.1.4.1.18.3.5.9.1.2.1 | | not-accessible | An entry in the Frame Relay Circuit table. |
| INT wfFr1CircuitDelete | 1.3.6.1.4.1.18.3.5.9.1.2.1.1 | INTEGER | read-write | Indication to delete this frame relay interface. |
| INT wfFr1CircuitNumber | 1.3.6.1.4.1.18.3.5.9.1.2.1.2 | INTEGER | read-only | Instance identifier. The circuit number of this interface. |
| INT wfFr1CircuitDlci | 1.3.6.1.4.1.18.3.5.9.1.2.1.3 | INTEGER | read-only | Instance identifier. This indicates which virtual circuit. |
| INT wfFr1CircuitState | 1.3.6.1.4.1.18.3.5.9.1.2.1.4 | INTEGER | read-only | Indicates the state of the particular virtual circuit. |
| INT wfFr1CircuitStateSet | 1.3.6.1.4.1.18.3.5.9.1.2.1.5 | INTEGER | read-write | User access for setting the state of a virtual circuit |
| CTR wfFr1CircuitReceivedFECNs | 1.3.6.1.4.1.18.3.5.9.1.2.1.6 | Counter | read-only | Number of frames received indicating forward congestion. |
| CTR wfFr1CircuitReceivedBECNs | 1.3.6.1.4.1.18.3.5.9.1.2.1.7 | Counter | read-only | Number of frames received indicating backward congestion. |
| CTR wfFr1CircuitSentFrames | 1.3.6.1.4.1.18.3.5.9.1.2.1.8 | Counter | read-only | The number of frames sent from this virtual circuit. |
| CTR wfFr1CircuitSentOctets | 1.3.6.1.4.1.18.3.5.9.1.2.1.9 | Counter | read-only | The number of octets sent from this virtual circuit. |
| CTR wfFr1CircuitReceivedFrames | 1.3.6.1.4.1.18.3.5.9.1.2.1.10 | Counter | read-only | The number of frames received from this virtual circuit. |
| CTR wfFr1CircuitReceivedOctets | 1.3.6.1.4.1.18.3.5.9.1.2.1.11 | Counter | read-only | The number of octets received from this virtual circuit. |
| TIK wfFr1CircuitCreationTime | 1.3.6.1.4.1.18.3.5.9.1.2.1.12 | TimeTicks | read-only | The value of sysUpTime when the vc was created. |
| TIK wfFr1CircuitLastTimeChange | 1.3.6.1.4.1.18.3.5.9.1.2.1.13 | TimeTicks | read-only | The value of sysUpTime when last there was a change in vc state. |
| INT wfFr1CircuitCommittedBurst | 1.3.6.1.4.1.18.3.5.9.1.2.1.14 | INTEGER | read-write | Indicates the maximum amount of data, in bits, that the network
agrees to transfer under normal conditions, during the measurement
interval. Wellfleet does not presently support this. |
| INT wfFr1CircuitExcessBurst | 1.3.6.1.4.1.18.3.5.9.1.2.1.15 | INTEGER | read-write | Indicates teh maximum amount of uncommitted data bits that the network
will attempt to deliver over the measurement interval. Wellfleet
does not presently support this. |
| INT wfFr1CircuitThroughput | 1.3.6.1.4.1.18.3.5.9.1.2.1.16 | INTEGER | read-write | This is the average number of 'Frame Relay Information Field'
bits transferred per second across a user network interface in one
direction, measured over the measurement interval. Wellfleet
does not presently support this. |
| INT wfFr1CircuitMulticast | 1.3.6.1.4.1.18.3.5.9.1.2.1.17 | INTEGER | read-write | Indicates whether this DLCI is used for multicast or single destination. |
| CTR wfFr1CircuitDiscards | 1.3.6.1.4.1.18.3.5.9.1.2.1.18 | Counter | read-only | The number of inbound frames discarded because of format errors,
because the VC is inactive or because the protocol was not registered
for this circuit. |
| CTR wfFr1CircuitDrops | 1.3.6.1.4.1.18.3.5.9.1.2.1.19 | Counter | read-only | Indicates how many outbound frames were dropped. Usually these are
dropped because the VC is not active. |
| INT wfFr1CircuitSubCct | 1.3.6.1.4.1.18.3.5.9.1.2.1.20 | INTEGER | read-write | Circuit number to use for this VC when configured in hybrid
(for bridging) or direct access (VC as a circuit) mode. |
| INT wfFr1CircuitMode | 1.3.6.1.4.1.18.3.5.9.1.2.1.21 | INTEGER | read-write | The mode of the given VC.
GROUP - treats the VC as one of many vc's on a circuit.
HYBRID - treats the VC as one of many vc's on a circuit for
protocol traffic, but as a separate circuit for bridging.
DIRECT - treats the VC as a separate circuit for all applications. |