| OID symbolic | OID numeric | Type | Access | Description |
| valereDcPowerMgt | 1.3.6.1.4.1.13858 | | | MIB Version 2.0
History
Apr 26, 2007 Added SysAlarm Config Table Version 2.0
Feb 08, 2003 Changed vpwrTrapDestinationTable to vpwrTrapTable
Corrected entry for vpwrTrapTable to be VpwrTrapTableEntry
This fixes errors generated by MG-SOFT mib compiler.Ver1.0
Oct 30, 2002 initial release - version 0.4 |
| vpwrDcPowerProducts | 1.3.6.1.4.1.13858.1 | | | |
| vpwrDcPowerSystem | 1.3.6.1.4.1.13858.2 | | | |
| vpwrSystemIdentGroup | 1.3.6.1.4.1.13858.2.1 | | | |
| STR vpwrIdentManufacturer | 1.3.6.1.4.1.13858.2.1.1 | DisplayString | read-only | The name of the DC Power manufacturer. |
| STR vpwrIdentModel | 1.3.6.1.4.1.13858.2.1.2 | DisplayString | read-only | The DC Power Model designation. |
| STR vpwrIdentControllerVersion | 1.3.6.1.4.1.13858.2.1.3 | DisplayString | read-only | The hardware/firmware version(s). This variable
may or may not have the same value as
vpwrIdentAgentSoftwareVersion. |
| STR vpwrIdentAgentSoftwareVersion | 1.3.6.1.4.1.13858.2.1.4 | DisplayString | read-only | The SNMP agent software version. This variable may or
may not have the same value as
vpwrIdentControllerFirmwareVersion. |
| STR vpwrIdentName | 1.3.6.1.4.1.13858.2.1.5 | DisplayString | read-write | A string identifying the system. This object should be
set by the administrator. |
| vpwrSystemIdentTable | 1.3.6.1.4.1.13858.2.1.6 | | not-accessible | This table describes shelves and modules
that make up the sysetm. |
| vpwrSystemIdentEntry | 1.3.6.1.4.1.13858.2.1.6.1 | | not-accessible | An entry containing information applicable to a
particular module making up the system. |
| NUM vpwrShelfIndex | 1.3.6.1.4.1.13858.2.1.6.1.1 | PositiveInteger | read-only | Identifies shelf number that this module belongs to.
The possible values are 1 through 16 limited by vpwrSystemShelfCapacity.
The shelf that contains the controller is identified as shelf number 1. |
| NUM vpwrModuleIndex | 1.3.6.1.4.1.13858.2.1.6.1.2 | PositiveInteger | read-only | This object identifies the module by its position in the shelf.
Module numbering starts from the controller/expansion controller end of
the shelf.
So, the module in the first slot has an index of 1, the next module
is 2 and so on.
Under the current scheme
- Rectifier module can have a number between 1 and 5.
- LVD module starts with an index of 6. |
| OID vpwrModuleOID | 1.3.6.1.4.1.13858.2.1.6.1.3 | OBJECT IDENTIFIER | read-only | It indicates the type of the module by specifiying its OID |
| INT vpwrModuleParameter | 1.3.6.1.4.1.13858.2.1.6.1.4 | INTEGER | read-only | The meaning of this object depends upon the module type
which is indicated by vpwrModuleOID as follows
- Current for Rectifier module.
- Not Applicable for LVD module |
| INT vpwrModuleOperStatus | 1.3.6.1.4.1.13858.2.1.6.1.5 | INTEGER | read-only | This object indicates current over all status of the module. |
| INT vpwrModuleCapacity | 1.3.6.1.4.1.13858.2.1.6.1.6 | INTEGER | read-only | The meaning of this object depends upon the module type
which is indicated by vpwrModuleOID as follows
- Capacity for Rectifier module.
- Not Applicable for LVD module |
| vpwrSystemConfigGroup | 1.3.6.1.4.1.13858.2.2 | | | |
| INT vpwrSystemTempCompensation | 1.3.6.1.4.1.13858.2.2.1 | INTEGER | read-write | This parameter enables/disables temperature compensation. |
| INT vpwrSystemTempCompStartTemperature | 1.3.6.1.4.1.13858.2.2.2 | INTEGER | read-write | The temperature at which temperature compensation becomes
active. |
| INT vpwrSystemTempCompStopVoltage | 1.3.6.1.4.1.13858.2.2.3 | INTEGER | read-write | When temperature compensation is active, vpwrSystemTempCompStopVoltage is the
limit to which float voltage will be reduced.
For example, to set this voltage to 51.75 volts enter a value of 5175. |
| INT vpwrSystemTempCompensationSlope | 1.3.6.1.4.1.13858.2.2.4 | INTEGER | read-write | The rate at which float voltage is changed, within the specified limits,
when temperature compensation is active. |
| INT vpwrSystemThermalSenseType | 1.3.6.1.4.1.13858.2.2.5 | INTEGER | read-write | This parameter selects the temperature sensing point for temperature
compensation (in)activation. |
| INT vpwrSystemHVAlarmSetpoint | 1.3.6.1.4.1.13858.2.2.6 | INTEGER | read-write | System High voltage alarm voltage setting. |
| INT vpwrSystemBDAlarmSetpoint | 1.3.6.1.4.1.13858.2.2.7 | INTEGER | read-write | System Battery Discharge voltage setting. |
| INT vpwrSystemInternalTempLThreshold | 1.3.6.1.4.1.13858.2.2.8 | INTEGER | read-write | Temperature value at which temperature compensation inactive (clear)
trap would be sent if temperature compensation was active when this
value is reached. |
| INT vpwrSystemInternalTempUThreshold | 1.3.6.1.4.1.13858.2.2.9 | INTEGER | read-write | Temperature value at which temperature compensation active (set) trap
would be sent. |
| vpwrSystemParameterGroup | 1.3.6.1.4.1.13858.2.3 | | | |
| INT vpwrSystemShelfCapacity | 1.3.6.1.4.1.13858.2.3.1 | INTEGER | read-only | It describes the maximum number of shelves that can/are controlled
by the controller. Each shelf is uniquely numbered in the range
from 1 to vpwrShelfCapacity. |
| INT vpwrSystemVoltage | 1.3.6.1.4.1.13858.2.3.2 | INTEGER | read-only | The current system voltage. |
| INT vpwrSystemCurrent | 1.3.6.1.4.1.13858.2.3.3 | INTEGER | read-only | The current system current. |
| INT vpwrSystemControllerState | 1.3.6.1.4.1.13858.2.3.4 | INTEGER | read-only | Current System state as shown on the enhanced display. |
| INT vpwrSystemInternalTemperature | 1.3.6.1.4.1.13858.2.3.5 | INTEGER | read-only | The current controller internal temperature. |
| INT vpwrSystemTempCompensationState | 1.3.6.1.4.1.13858.2.3.6 | INTEGER | read-only | Active or Inactive. Applicable only if temperature compensation is enabled.
This means that the controller is temperature compensating the float voltage. |
| INT vpwrSystemType | 1.3.6.1.4.1.13858.2.3.7 | INTEGER | read-only | This parameter describes the type of the system being managed.
This object is set by Valere Power Inc. |
| vpwrDcPowerRectifier | 1.3.6.1.4.1.13858.3 | | | |
| vpwrRectifierConfigGroup | 1.3.6.1.4.1.13858.3.1 | | | |
| INT vpwrRectifierFVSetpoint | 1.3.6.1.4.1.13858.3.1.1 | INTEGER | read-write | System Float Voltage setting |
| INT vpwrRectifierHVSDSetpoint | 1.3.6.1.4.1.13858.3.1.2 | INTEGER | read-write | System High Voltage Shutdown voltage setting |
| vpwrRectifierAlarmGroup | 1.3.6.1.4.1.13858.3.2 | | | |
| vpwrRectAlarmDCFail | 1.3.6.1.4.1.13858.3.2.1 | | | |
| vpwrRectAlarmBoostFail | 1.3.6.1.4.1.13858.3.2.2 | | | |
| vpwrRectAlarmACFail | 1.3.6.1.4.1.13858.3.2.3 | | | |
| vpwrRectAlarmHVSD | 1.3.6.1.4.1.13858.3.2.4 | | | |
| vpwrRectAlarmFanFail | 1.3.6.1.4.1.13858.3.2.5 | | | |
| vpwrRectAlarmAmbTemp | 1.3.6.1.4.1.13858.3.2.6 | | | |
| vpwrRectAlarmIntTemp | 1.3.6.1.4.1.13858.3.2.7 | | | |
| vpwrRectAlarmIShare | 1.3.6.1.4.1.13858.3.2.8 | | | |
| vpwrRectAlarmUV | 1.3.6.1.4.1.13858.3.2.9 | | | |
| vpwrRectAlarmLowVoltage | 1.3.6.1.4.1.13858.3.2.10 | | | |
| vpwrRectAlarmReserved | 1.3.6.1.4.1.13858.3.2.11 | | | |
| vpwrRectAlarmDCEnable | 1.3.6.1.4.1.13858.3.2.12 | | | |
| vpwrRectAlarmRemoteShutdown | 1.3.6.1.4.1.13858.3.2.13 | | | |
| vpwrRectAlarmModDisableShutdown | 1.3.6.1.4.1.13858.3.2.14 | | | |
| vpwrRectAlarmShortPinShutdown | 1.3.6.1.4.1.13858.3.2.15 | | | |
| vpwrRectAlarmBoostComm | 1.3.6.1.4.1.13858.3.2.16 | | | |
| vpwrRectifierTestGroup | 1.3.6.1.4.1.13858.3.3 | | | |
| vpwrDcPowerLvd | 1.3.6.1.4.1.13858.4 | | | |
| vpwrLvdConfigGroup | 1.3.6.1.4.1.13858.4.1 | | | |
| INT vpwrLvdWarningSetpoint | 1.3.6.1.4.1.13858.4.1.1 | INTEGER | read-write | LVD Warning voltage setpoint. |
| INT vpwrLvdDisconnectSetpoint | 1.3.6.1.4.1.13858.4.1.2 | INTEGER | read-write | LVD disconnect voltage setpoint. |
| INT vpwrLvdReconnectSetpoint | 1.3.6.1.4.1.13858.4.1.3 | INTEGER | read-write | LVD Reconnect voltage setpoint. |
| INT vpwrLvdReconnectDelayTimer | 1.3.6.1.4.1.13858.4.1.4 | INTEGER | read-write | The delay time, in seconds, before LVD is reconnected |
| vpwrLvdAlarmGroup | 1.3.6.1.4.1.13858.4.2 | | | |
| vpwrLvdAlarmContactorOpen | 1.3.6.1.4.1.13858.4.2.1 | | | Contactor open |
| vpwrLvdAlarmCBOpen | 1.3.6.1.4.1.13858.4.2.2 | | | Circuit Breaker open |
| vpwrTrapLvdFuseOpen | 1.3.6.1.4.1.13858.4.2.3 | | | Fuse open |
| vpwrLvdAlarmWarning | 1.3.6.1.4.1.13858.4.2.4 | | | Plant Voltage below warning threshold |
| vpwrLvdTestGroup | 1.3.6.1.4.1.13858.4.3 | | | |
| vpwrDcPowerTest | 1.3.6.1.4.1.13858.5 | | | |
| vpwrDcPowerModuleIdent | 1.3.6.1.4.1.13858.6 | | | |
| vpwrDcPowerBatteryGroup | 1.3.6.1.4.1.13858.7 | | | |
| vpwrBatteryTempGroup | 1.3.6.1.4.1.13858.7.1 | | | |
| vpwrBatteryTempTable | 1.3.6.1.4.1.13858.7.1.1 | | not-accessible | This table describes battery temperature probes. |
| vpwrBatteryTempTableEntry | 1.3.6.1.4.1.13858.7.1.1.1 | | not-accessible | An entry containing information applicable to a
particular temperature probe. |
| INT vpwrBatteryTempIndex | 1.3.6.1.4.1.13858.7.1.1.1.1 | INTEGER | read-only | Index into temperature table |
| STR vpwrBatteryTempName | 1.3.6.1.4.1.13858.7.1.1.1.2 | DisplayString | read-write | A string identifying probe location. |
| INT vpwrBatteryTemp | 1.3.6.1.4.1.13858.7.1.1.1.3 | INTEGER | read-only | Current temperature as recorded by the probe. |
| INT vpwrBatteryTempLThreshold | 1.3.6.1.4.1.13858.7.1.2 | INTEGER | read-write | Temperature value at which a clear trap would be sent.
All three battery temperature must be at or below this value
to trigger this trap. |
| INT vpwrBatteryTempUThreshold | 1.3.6.1.4.1.13858.7.1.3 | INTEGER | read-write | Temperature value at which a set trap would be sent.
Any one of the three battery temperatures at or exceeding this limit
would trigger the trap. |
| vpwrDcPowerAlarmGroup | 1.3.6.1.4.1.13858.8 | | | |
| G32 vpwrAlarmsPresentEx | 1.3.6.1.4.1.13858.8.1 | Gauge32 | read-only | The present number of active alarm conditions. |
| vpwrAlarmTable | 1.3.6.1.4.1.13858.8.2 | | not-accessible | A list of alarm table entries. The table contains
zero, one, or many rows at any moment, depending upon
the number of alarm conditions in effect. The table
is initially empty at agent startup. The agent
creates a row in the table each time a condition is
detected and deletes that row when that condition no
longer pertains.
The vpwrAlarmIndex, for each type of module starts at 1
and is limited by the total number of alarams that can be
generated by the module.
Alarms are named by an AutonomousType (OBJECT
IDENTIFIER), vpwrAlarmDescr, to allow a single table to
reflect alarms for different type of modules.
The number of rows in the table at any given time is
reflected by the value of vpwrAlarmsPresent. |
| vpwrAlarmEntry | 1.3.6.1.4.1.13858.8.2.1 | | not-accessible | An entry containing information applicable to a
particular alarm. |
| NUM vpwrAlarmIndex | 1.3.6.1.4.1.13858.8.2.1.1 | PositiveInteger | read-only | Identifies the alarm associated with the module.
It is unique on per module type basis. For example,
multiple rectifiers can have the same alarm and therefore same
vpwrAlarmIndex active at any one time. |
| OID vpwrAlarmDescr | 1.3.6.1.4.1.13858.8.2.1.2 | AutonomousType | read-only | A reference to an alarm description object. The
object referenced should not be accessible, but rather
be used to provide a unique description of the alarm
condition. |
| TIM vpwrAlarmTime | 1.3.6.1.4.1.13858.8.2.1.3 | TimeStamp | read-only | The value of sysUpTime when the alarm condition was
detected. |
| sysAlarmConfigTable | 1.3.6.1.4.1.13858.8.4 | | not-accessible | This table describes battery temperature probes. |
| sysAlarmConfigEntry | 1.3.6.1.4.1.13858.8.4.1 | | not-accessible | An entry containing information applicable to a
particular temperature probe. |
| INT sysAlarmIndex | 1.3.6.1.4.1.13858.8.4.1.1 | INTEGER | read-only | Index into temperature table |
| STR sysAlarmDefaultName | 1.3.6.1.4.1.13858.8.4.1.2 | DisplayString | read-only | A string identifying probe location. |
| STR sysAlarmCustomName | 1.3.6.1.4.1.13858.8.4.1.3 | DisplayString | read-write | A string identifying probe location. |
| INT sysAlarmSeverity | 1.3.6.1.4.1.13858.8.4.1.4 | INTEGER | read-write | Alarm Severity as denoted by Major and Minor Alarm Mask |
| STR sysAlarmToRelayMapping | 1.3.6.1.4.1.13858.8.4.1.5 | DisplayString | read-write | No additional mapping = 0
Map to Relay A = 1
Map to Relay B = 2
Map to Relay C = 4
Map to Relay D = 8
Map to Relay E = 16
Map to Relay F = 32
Map to Relay A and B = (1 + 2) and so on
The major/minor classification of alarms automatically
associates it with Major/Minor relay. Assigning a null
mapping here does not override sysRelayAlarmSeverity for
the alarm.
It should be used to define mapping to additional relays. |
| INT sysAlarmOperStatus | 1.3.6.1.4.1.13858.8.4.1.6 | INTEGER | read-only | Indicates current alarm status |
| vpwrDcPowerSnmpConfig | 1.3.6.1.4.1.13858.9 | | | |
| vpwrTrapTable | 1.3.6.1.4.1.13858.9.1 | | not-accessible | A list of possible trap destinations depending upon
the criticality of the trap. |
| vpwrTrapTableEntry | 1.3.6.1.4.1.13858.9.1.1 | | not-accessible | An entry containing information applicable to a
particular trap destination. |
| INT vpwrTrapIpIndex | 1.3.6.1.4.1.13858.9.1.1.1 | INTEGER | read-only | Trap Entry Index |
| IP vpwrTrapIpAddress | 1.3.6.1.4.1.13858.9.1.1.2 | IpAddress | read-write | Trap destination IP Address |
| INT vpwrTrapCriticality | 1.3.6.1.4.1.13858.9.1.1.3 | INTEGER | read-write | Criticality of traps sent to this IP Address |
| vpwrDcPowerTraps | 1.3.6.1.4.1.13858.10 | | | |
| NTF vpwrTrapPowerMajorAlarm | 1.3.6.1.4.1.13858.10.0.1 | | | Major Alarm |
| NTF vpwrTrapPowerMinorAlarm | 1.3.6.1.4.1.13858.10.0.2 | | | Minor Alarm |
| NTF vpwrTrapACFAlarm | 1.3.6.1.4.1.13858.10.0.3 | | | AC Fail Alarm |
| NTF vpwrTrapHVAlarm | 1.3.6.1.4.1.13858.10.0.4 | | | High Voltage Warning Alarm |
| NTF vpwrTrapHVSDAlarm | 1.3.6.1.4.1.13858.10.0.5 | | | High Voltage Shutdown Alarm |
| NTF vpwrTrapBDAlarm | 1.3.6.1.4.1.13858.10.0.6 | | | Battery on Discharge Alarm |
| NTF vpwrTrapLVDWarningAlarm | 1.3.6.1.4.1.13858.10.0.7 | | | LVD Warning Alarm |
| NTF vpwrTrapLVDOpenAlarm | 1.3.6.1.4.1.13858.10.0.8 | | | LVD Open Alarm |
| NTF vpwrTrapDistAlarm | 1.3.6.1.4.1.13858.10.0.9 | | | Distribution Open Alarm |
| NTF vpwrTrapAuxAlarm | 1.3.6.1.4.1.13858.10.0.10 | | | Auxiliary System Alarm |
| NTF vpwrTrapSystemRedundancyAlarm | 1.3.6.1.4.1.13858.10.0.11 | | | System Redundant Capacity Alarm |
| NTF vpwrTrapIShareAlarm | 1.3.6.1.4.1.13858.10.0.12 | | | Rectifier Current Share Alarm |
| NTF vpwrTrapModuleFailAlarm | 1.3.6.1.4.1.13858.10.0.13 | | | Single Rectifier Fail Alarm |
| NTF vpwrTrapMultipleModuleFailAlarm | 1.3.6.1.4.1.13858.10.0.14 | | | Multiple Rectifier Fail Alarm |
| NTF vpwrTrapModuleCommAlarm | 1.3.6.1.4.1.13858.10.0.15 | | | Module Communication Alarm |
| NTF vpwrTrapSystemOverTemperatureAlarm | 1.3.6.1.4.1.13858.10.0.16 | | | System Over Temperature Alarm |
| NTF vpwrTrapSystemOK | 1.3.6.1.4.1.13858.10.0.17 | | | SYSTEM OK - No Active Alarms |
| NTF vpwrTrapModuleInserted | 1.3.6.1.4.1.13858.10.0.18 | | | A new module has been inserted into the system. |
| NTF vpwrTrapModuleRemoved | 1.3.6.1.4.1.13858.10.0.19 | | | A module has been removed from the system. |
| NTF vpwrTrapThermalCompActive | 1.3.6.1.4.1.13858.10.0.20 | | | Thermal compensation has become active. |
| NTF vpwrTrapThermalCompInactive | 1.3.6.1.4.1.13858.10.0.21 | | | Thermal compensation has been de-activated. |
| NTF vpwrTrapInternalTempAlarmSet | 1.3.6.1.4.1.13858.10.0.22 | | | Internal Temperature upper threshold exceeded. |
| NTF vpwrTrapInternalTempAlarmCleared | 1.3.6.1.4.1.13858.10.0.23 | | | Internal Temperature within limits |
| NTF vpwrTrapBatteryTempAlarmSet | 1.3.6.1.4.1.13858.10.0.24 | | | At least one Battery Temperature exceeded upper threshold. |
| NTF vpwrTrapBatteryTempAlarmCleared | 1.3.6.1.4.1.13858.10.0.25 | | | All Battery Temperatures within limits |
| vpwrDcPowerTrapsMsgString | 1.3.6.1.4.1.13858.11 | | | |
| STR vpwrTrapsMsgString | 1.3.6.1.4.1.13858.11.1 | DisplayString | not-accessible | Place holder for trap notification message string |