All MIBs › WebGraph-8xThermometer-US-MIB
Category: Power and Environmental Monitoring
Description: Monitors WebGraph 8-channel thermometer sensor readings and alarm thresholds for environmental temperature tracking.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is WebGraph-8xThermometer-US-MIB?
WebGraph-8xThermometer-US-MIB is a vendor MIB for WebGraph/Web-IO 8-channel networked thermometer sensor modules, small SNMP-managed environmental monitoring appliances rather than a general-purpose network device. It exposes environmental sensor data, specifically temperature readings from up to eight independent sensor channels, along with binary (threshold-triggered) temperature status and packet/counter-style representations of those readings. Its monitoring role is entirely environmental hardware status: it is used to watch ambient or equipment temperature at multiple points (e.g. a server room, rack, or cabinet) and to detect over-temperature or under-temperature alarm conditions via the binary threshold values. It is a standalone vendor MIB with no significant dependency on other standard MIBs, functioning as a purpose-built sensor-polling interface. It is typically deployed in data centers, network closets, or equipment cabinets where multiple temperature points need centralized SNMP-based environmental monitoring alongside other infrastructure devices. Network engineers evaluating or troubleshooting this functionality can download the WebGraph-8xThermometer-US-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in WebGraph-8xThermometer-US-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- WebGraph/Web-IO 8-channel thermometer sensor module
- environmental monitoring appliance
Monitoring Examples
An administrator would poll the wtWebioAn8GraphSensorTable to enumerate the eight configured sensor channels (indexed via wtWebioAn8GraphSensorNo), then read wtWebioAn8GraphTempValueTable/wtWebioAn8GraphTempValue for each channel's current temperature and wtWebioAn8GraphBinaryTempValueTable/wtWebioAn8GraphBinaryTempValue for its threshold-alarm state; a binary value flipping to the alarm condition on one channel would reveal that a specific rack or cabinet location has exceeded its safe temperature range. The wtWebioAn8GraphTempValuePktTable/Entry structures suggest the device also exposes readings in a packetized/bulk format for efficient polling of all channels at once.
What Can Be Monitored
- per-channel temperature reading
- sensor channel number/identity
- binary over/under-temperature alarm state
- bulk/packetized temperature values across channels
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| IpAddress | |
| NetworkAddress | |
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString | |
| PhysAddress |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| wut | 1.3.6.1.4.1.5040 | |||
| wtComServer | 1.3.6.1.4.1.5040.1 | |||
| wtWebio | 1.3.6.1.4.1.5040.1.2 | |||
| wtWebioAn8Graph | 1.3.6.1.4.1.5040.1.2.6 | |||
| NTF wtWebioAn8GraphAlert1 | 1.3.6.1.4.1.5040.1.2.6.0.11 | This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert2 | 1.3.6.1.4.1.5040.1.2.6.0.12 | This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert3 | 1.3.6.1.4.1.5040.1.2.6.0.13 | This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert4 | 1.3.6.1.4.1.5040.1.2.6.0.14 | This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert5 | 1.3.6.1.4.1.5040.1.2.6.0.15 | This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert6 | 1.3.6.1.4.1.5040.1.2.6.0.16 | This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert7 | 1.3.6.1.4.1.5040.1.2.6.0.17 | This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert8 | 1.3.6.1.4.1.5040.1.2.6.0.18 | This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert9 | 1.3.6.1.4.1.5040.1.2.6.0.71 | This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert10 | 1.3.6.1.4.1.5040.1.2.6.0.72 | This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert11 | 1.3.6.1.4.1.5040.1.2.6.0.73 | This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert12 | 1.3.6.1.4.1.5040.1.2.6.0.74 | This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert13 | 1.3.6.1.4.1.5040.1.2.6.0.75 | This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert14 | 1.3.6.1.4.1.5040.1.2.6.0.76 | This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert15 | 1.3.6.1.4.1.5040.1.2.6.0.77 | This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlert16 | 1.3.6.1.4.1.5040.1.2.6.0.78 | This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled. | ||
| NTF wtWebioAn8GraphAlertDiag | 1.3.6.1.4.1.5040.1.2.6.0.110 | This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled. | ||
| wtWebioAn8GraphTemp | 1.3.6.1.4.1.5040.1.2.6.1 | |||
| INT wtWebioAn8GraphSensors | 1.3.6.1.4.1.5040.1.2.6.1.1 | INTEGER | read-only | Number of temperature sensors |
| wtWebioAn8GraphSensorTable | 1.3.6.1.4.1.5040.1.2.6.1.2 | not-accessible | List of sensors. | |
| wtWebioAn8GraphSensorEntry | 1.3.6.1.4.1.5040.1.2.6.1.2.1 | not-accessible | Temperature sensor numbers. | |
| INT wtWebioAn8GraphSensorNo | 1.3.6.1.4.1.5040.1.2.6.1.2.1.1 | INTEGER | read-only | Temperature sensor number. |
| wtWebioAn8GraphTempValueTable | 1.3.6.1.4.1.5040.1.2.6.1.3 | not-accessible | List of temperature values corresponding to the channel numbers. | |
| wtWebioAn8GraphTempValueEntry | 1.3.6.1.4.1.5040.1.2.6.1.3.1 | not-accessible | Temperatures of the sensors. | |
| OCT wtWebioAn8GraphTempValue | 1.3.6.1.4.1.5040.1.2.6.1.3.1.1 | OCTET STRING | read-only | Temperature value of the sensor, ASCII, 5 characters in length. |
| wtWebioAn8GraphBinaryTempValueTable | 1.3.6.1.4.1.5040.1.2.6.1.4 | not-accessible | List of binary temperature values corresponding to the channel numbers. | |
| wtWebioAn8GraphBinaryTempValueEntry | 1.3.6.1.4.1.5040.1.2.6.1.4.1 | not-accessible | Binary temperature values of the sensors. | |
| INT wtWebioAn8GraphBinaryTempValue | 1.3.6.1.4.1.5040.1.2.6.1.4.1.1 | INTEGER | read-only | Binary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x4FFF6 indicates an invalid measured value. |
| wtWebioAn8GraphTempValuePktTable | 1.3.6.1.4.1.5040.1.2.6.1.8 | not-accessible | List of temperature values corresponding to the channel numbers. | |
| wtWebioAn8GraphTempValuePktEntry | 1.3.6.1.4.1.5040.1.2.6.1.8.1 | not-accessible | Temperatures of the sensors. | |
| OCT wtWebioAn8GraphTempValuePkt | 1.3.6.1.4.1.5040.1.2.6.1.8.1.1 | OCTET STRING | read-only | Temperature value of the sensor, ASCII, 5 characters in length, decimal point. |
| wtWebioAn8GraphSessCntrl | 1.3.6.1.4.1.5040.1.2.6.2 | |||
| OCT wtWebioAn8GraphSessCntrlPassword | 1.3.6.1.4.1.5040.1.2.6.2.1 | OCTET STRING | read-write | Entering this password opens a session which is ended by writing a 1 to wtWebioAn8GraphSessCntrlLogout. When read this variable provides a string of length zero. |
| INT wtWebioAn8GraphSessCntrlConfigMode | 1.3.6.1.4.1.5040.1.2.6.2.2 | INTEGER | read-only | When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read. |
| INT wtWebioAn8GraphSessCntrlLogout | 1.3.6.1.4.1.5040.1.2.6.2.3 | INTEGER | read-write | If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0. |
| OCT wtWebioAn8GraphSessCntrlAdminPassword | 1.3.6.1.4.1.5040.1.2.6.2.4 | OCTET STRING | read-write | This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public. |
| OCT wtWebioAn8GraphSessCntrlConfigPassword | 1.3.6.1.4.1.5040.1.2.6.2.5 | OCTET STRING | read-write | This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer. |
| wtWebioAn8GraphConfig | 1.3.6.1.4.1.5040.1.2.6.3 | |||
| wtWebioAn8GraphDevice | 1.3.6.1.4.1.5040.1.2.6.3.1 | |||
| wtWebioAn8GraphText | 1.3.6.1.4.1.5040.1.2.6.3.1.1 | |||
| OCT wtWebioAn8GraphDeviceName | 1.3.6.1.4.1.5040.1.2.6.3.1.1.1 | OCTET STRING | read-write | Name of the Webio, which is user definable. |
| OCT wtWebioAn8GraphDeviceText | 1.3.6.1.4.1.5040.1.2.6.3.1.1.2 | OCTET STRING | read-write | Description of the Webio, which is user definable. |
| OCT wtWebioAn8GraphDeviceLocation | 1.3.6.1.4.1.5040.1.2.6.3.1.1.3 | OCTET STRING | read-write | Description of the location of the Webio, which is user definable. |
| OCT wtWebioAn8GraphDeviceContact | 1.3.6.1.4.1.5040.1.2.6.3.1.1.4 | OCTET STRING | read-write | Contact address of the system operator of the Webio, which is user definable. |
| wtWebioAn8GraphTimeDate | 1.3.6.1.4.1.5040.1.2.6.3.1.2 | |||
| wtWebioAn8GraphTimeZone | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1 | |||
| INT wtWebioAn8GraphTzOffsetHrs | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.1 | INTEGER | read-write | Offset hours for the time zone (winter time) with respect to UTC. |
| INT wtWebioAn8GraphTzOffsetMin | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.2 | INTEGER | read-write | Offset minutes for the time zone (winter time) with respect to UTC. |
| OCT wtWebioAn8GraphTzEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.3 | OCTET STRING | read-write | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone |
| INT wtWebioAn8GraphStTzOffsetHrs | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.4 | INTEGER | read-write | Offset hours of the time zone (summer time) with respect to UTC. |
| INT wtWebioAn8GraphStTzOffsetMin | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.5 | INTEGER | read-write | Offset minutes of the time zone (summer time) with respect to UTC. |
| OCT wtWebioAn8GraphStTzEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.6 | OCTET STRING | read-write | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime |
| INT wtWebioAn8GraphStTzStartMonth | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.7 | INTEGER | read-write | Month in which the change is made from winter time to summer time. |
| INT wtWebioAn8GraphStTzStartMode | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.8 | INTEGER | read-write | Mode of the day of the week for which the change is made from winter time to summer time. |
| INT wtWebioAn8GraphStTzStartWday | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.9 | INTEGER | read-write | Day of the week on which the change is made from winter time to summer time |
| INT wtWebioAn8GraphStTzStartHrs | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.10 | INTEGER | read-write | Hour in which the time zone is changed from winter to summer time with respect to UTC. |
| INT wtWebioAn8GraphStTzStartMin | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.11 | INTEGER | read-write | Minute in which the time zone is changed from winter to summer time with respect to UTC. |
| INT wtWebioAn8GraphStTzStopMonth | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.12 | INTEGER | read-write | Month in which the change is made from summer time to winter time. |
| INT wtWebioAn8GraphStTzStopMode | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.13 | INTEGER | read-write | Mode of the week day on which the change is made from summer time to winter time. |
| INT wtWebioAn8GraphStTzStopWday | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.14 | INTEGER | read-write | Day of the week on which the change is made from summer time to winter time. |
| INT wtWebioAn8GraphStTzStopHrs | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.15 | INTEGER | read-write | Hour at which the time zone is changed from summer to winter time with respect to UTC. |
| INT wtWebioAn8GraphStTzStopMin | 1.3.6.1.4.1.5040.1.2.6.3.1.2.1.16 | INTEGER | read-write | Minute at which the time zone is changed from summer to winter time with respect to UTC. |
| wtWebioAn8GraphTimeServer | 1.3.6.1.4.1.5040.1.2.6.3.1.2.2 | |||
| OCT wtWebioAn8GraphTimeServer1 | 1.3.6.1.4.1.5040.1.2.6.3.1.2.2.1 | OCTET STRING | read-write | IP address or name of the 1st time server in ASCII |
| OCT wtWebioAn8GraphTimeServer2 | 1.3.6.1.4.1.5040.1.2.6.3.1.2.2.2 | OCTET STRING | read-write | IP address or name of the 2nd time server in ASCII |
| OCT wtWebioAn8GraphTsEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.2.2.3 | OCTET STRING | read-write | Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server |
| INT wtWebioAn8GraphTsSyncTime | 1.3.6.1.4.1.5040.1.2.6.3.1.2.2.4 | INTEGER | read-write | Daily synchronisation time with the time server (hour: 0-23). |
| wtWebioAn8GraphDeviceClock | 1.3.6.1.4.1.5040.1.2.6.3.1.2.3 | |||
| INT wtWebioAn8GraphClockHrs | 1.3.6.1.4.1.5040.1.2.6.3.1.2.3.1 | INTEGER | read-write | Clock hours taking into account the time zone settings. |
| INT wtWebioAn8GraphClockMin | 1.3.6.1.4.1.5040.1.2.6.3.1.2.3.2 | INTEGER | read-write | Clock minutes taking into account the time zone settings. |
| INT wtWebioAn8GraphClockDay | 1.3.6.1.4.1.5040.1.2.6.3.1.2.3.3 | INTEGER | read-write | Date: Day of the month, taking into account the time zone settings. |
| INT wtWebioAn8GraphClockMonth | 1.3.6.1.4.1.5040.1.2.6.3.1.2.3.4 | INTEGER | read-write | Date: Month, taking into account the time zone settings. |
| INT wtWebioAn8GraphClockYear | 1.3.6.1.4.1.5040.1.2.6.3.1.2.3.5 | INTEGER | read-write | Date: Year, taking into account the time zone settings. |
| wtWebioAn8GraphBasic | 1.3.6.1.4.1.5040.1.2.6.3.1.3 | |||
| wtWebioAn8GraphNetwork | 1.3.6.1.4.1.5040.1.2.6.3.1.3.1 | |||
| IP wtWebioAn8GraphIpAddress | 1.3.6.1.4.1.5040.1.2.6.3.1.3.1.1 | IpAddress | read-write | IP address of the Webio |
| IP wtWebioAn8GraphSubnetMask | 1.3.6.1.4.1.5040.1.2.6.3.1.3.1.2 | IpAddress | read-write | Subnet mask of the Webio |
| IP wtWebioAn8GraphGateway | 1.3.6.1.4.1.5040.1.2.6.3.1.3.1.3 | IpAddress | read-write | Gateway of the Webio |
| OCT wtWebioAn8GraphDnsServer1 | 1.3.6.1.4.1.5040.1.2.6.3.1.3.1.4 | OCTET STRING | read-write | IP address of the 1st DNS server in ASCII |
| OCT wtWebioAn8GraphDnsServer2 | 1.3.6.1.4.1.5040.1.2.6.3.1.3.1.5 | OCTET STRING | read-write | IP address of the 2nd DNS server in ASCII |
| OCT wtWebioAn8GraphAddConfig | 1.3.6.1.4.1.5040.1.2.6.3.1.3.1.6 | OCTET STRING | read-write | Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable Bit 1: DHCP disable |
| wtWebioAn8GraphHTTP | 1.3.6.1.4.1.5040.1.2.6.3.1.3.2 | |||
| OCT wtWebioAn8GraphStartup | 1.3.6.1.4.1.5040.1.2.6.3.1.3.2.1 | OCTET STRING | read-write | Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time. |
| OCT wtWebioAn8GraphGetHeaderEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.3.2.2 | OCTET STRING | read-write | If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable |
| INT wtWebioAn8GraphHttpPort | 1.3.6.1.4.1.5040.1.2.6.3.1.3.2.3 | INTEGER | read-write | Definition of the standard HTML port (Default: 80). |
| wtWebioAn8GraphMail | 1.3.6.1.4.1.5040.1.2.6.3.1.3.3 | |||
| OCT wtWebioAn8GraphMailAdName | 1.3.6.1.4.1.5040.1.2.6.3.1.3.3.1 | OCTET STRING | read-write | Device name for mail administration. |
| OCT wtWebioAn8GraphMailReply | 1.3.6.1.4.1.5040.1.2.6.3.1.3.3.2 | OCTET STRING | read-write | Reply address for the mail server. |
| OCT wtWebioAn8GraphMailServer | 1.3.6.1.4.1.5040.1.2.6.3.1.3.3.3 | OCTET STRING | read-write | Name or IP address of the mail server. |
| OCT wtWebioAn1MailEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.3.3.4 | OCTET STRING | read-write | Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable |
| OCT wtWebioAn8GraphMailAuthentication | 1.3.6.1.4.1.5040.1.2.6.3.1.3.3.5 | OCTET STRING | read-write | Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication |
| OCT wtWebioAn8GraphMailAuthUser | 1.3.6.1.4.1.5040.1.2.6.3.1.3.3.6 | OCTET STRING | read-write | Name of the user to be authenticated. |
| OCT wtWebioAn8GraphMailAuthPassword | 1.3.6.1.4.1.5040.1.2.6.3.1.3.3.7 | OCTET STRING | read-write | Authentication password. |
| OCT wtWebioAn8GraphMailPop3Server | 1.3.6.1.4.1.5040.1.2.6.3.1.3.3.8 | OCTET STRING | read-write | Name or Ip-address of the POP3 Servers. |
| wtWebioAn8GraphSNMP | 1.3.6.1.4.1.5040.1.2.6.3.1.3.4 | |||
| OCT wtWebioAn8GraphSnmpCommunityStringRead | 1.3.6.1.4.1.5040.1.2.6.3.1.3.4.1 | OCTET STRING | read-write | Community string read only |
| OCT wtWebioAn8GraphSnmpCommunityStringReadWrite | 1.3.6.1.4.1.5040.1.2.6.3.1.3.4.2 | OCTET STRING | read-write | Community string read / write |
| OCT wtWebioAn8GraphSystemTrapManagerIP | 1.3.6.1.4.1.5040.1.2.6.3.1.3.4.3 | OCTET STRING | read-write | Name or IP address of the TCP server which accepts the system trap. |
| OCT wtWebioAn8GraphSystemTrapEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.3.4.4 | OCTET STRING | read-write | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused |
| OCT wtWebioAn8GraphSnmpEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.3.4.5 | OCTET STRING | read-write | Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable |
| OCT wtWebioAn8GraphSnmpCommunityStringTrap | 1.3.6.1.4.1.5040.1.2.6.3.1.3.4.6 | OCTET STRING | read-write | Community string send within traps. |
| wtWebioAn8GraphUDP | 1.3.6.1.4.1.5040.1.2.6.3.1.3.5 | |||
| INT wtWebioAn8GraphUdpPort | 1.3.6.1.4.1.5040.1.2.6.3.1.3.5.1 | INTEGER | read-write | Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device. |
| OCT wtWebioAn8GraphUdpEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.3.5.2 | OCTET STRING | read-write | Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable |
| wtWebioAn8GraphSyslog | 1.3.6.1.4.1.5040.1.2.6.3.1.3.6 | |||
| OCT wtWebioAn8GraphSyslogServerIP | 1.3.6.1.4.1.5040.1.2.6.3.1.3.6.1 | OCTET STRING | read-write | Name or IP address of the Syslog server, which accepts the Syslog messgaes. |
| INT wtWebioAn8GraphSyslogServerPort | 1.3.6.1.4.1.5040.1.2.6.3.1.3.6.2 | INTEGER | read-write | Portnumber of the Syslog servers, default 514. |
| OCT wtWebioAn8GraphSyslogSystemMessagesEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.3.6.3 | OCTET STRING | read-write | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused |
| OCT wtWebioAn8GraphSyslogEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.3.6.4 | OCTET STRING | read-write | Set bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable |
| wtWebioAn8GraphFTP | 1.3.6.1.4.1.5040.1.2.6.3.1.3.7 | |||
| OCT wtWebioAn8GraphFTPServerIP | 1.3.6.1.4.1.5040.1.2.6.3.1.3.7.1 | OCTET STRING | read-write | Name or IP address of the FTP server, which accepts the FTP messages. |
| INT wtWebioAn8GraphFTPServerControlPort | 1.3.6.1.4.1.5040.1.2.6.3.1.3.7.2 | INTEGER | read-write | Portnumber of the control port of the FTP server, default 21. |
| OCT wtWebioAn8GraphFTPUserName | 1.3.6.1.4.1.5040.1.2.6.3.1.3.7.3 | OCTET STRING | read-write | FTP Loggin: user name. |
| OCT wtWebioAn8GraphFTPPassword | 1.3.6.1.4.1.5040.1.2.6.3.1.3.7.4 | OCTET STRING | read-write | FTP Loggin: user password. |
| OCT wtWebioAn8GraphFTPAccount | 1.3.6.1.4.1.5040.1.2.6.3.1.3.7.5 | OCTET STRING | read-write | FTP Loggin: name of account. |
| OCT wtWebioAn8GraphFTPOption | 1.3.6.1.4.1.5040.1.2.6.3.1.3.7.6 | OCTET STRING | read-write | Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable |
| OCT wtWebioAn8GraphFTPEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.3.7.7 | OCTET STRING | read-write | Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable |
| wtWebioAn8GraphDatalogger | 1.3.6.1.4.1.5040.1.2.6.3.1.4 | |||
| INT wtWebioAn8GraphLoggerTimebase | 1.3.6.1.4.1.5040.1.2.6.3.1.4.1 | INTEGER | read-write | Time base of the data logger |
| OCT wtWebioAn8GraphLoggerSensorSel | 1.3.6.1.4.1.5040.1.2.6.3.1.4.2 | OCTET STRING | read-write | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8 |
| OCT wtWebioAn8GraphDisplaySensorSel | 1.3.6.1.4.1.5040.1.2.6.3.1.4.3 | OCTET STRING | read-write | Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8 |
| wtWebioAn8GraphSensorColorTable | 1.3.6.1.4.1.5040.1.2.6.3.1.4.4 | not-accessible | List of sensor colors for the praphical presentation. | |
| wtWebioAn8GraphSensorColorEntry | 1.3.6.1.4.1.5040.1.2.6.3.1.4.4.1 | not-accessible | Index numbers of the sensors. | |
| OCT wtWebioAn8GraphSensorColor | 1.3.6.1.4.1.5040.1.2.6.3.1.4.4.1.1 | OCTET STRING | read-write | Color of the sensors at the praphical presention. |
| OCT wtWebioAn8GraphAutoScaleEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.4.5 | OCTET STRING | read-write | If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable |
| OCT wtWebioAn8GraphVerticalUpperLimit | 1.3.6.1.4.1.5040.1.2.6.3.1.4.6 | OCTET STRING | read-write | This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places. |
| OCT wtWebioAn8GraphVerticalLowerLimit | 1.3.6.1.4.1.5040.1.2.6.3.1.4.7 | OCTET STRING | read-write | This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places. |
| INT wtWebioAn8GraphHorizontalZoom | 1.3.6.1.4.1.5040.1.2.6.3.1.4.8 | INTEGER | read-write | Defines the default zoom stage, if no auto scaling is selected. |
| wtWebioAn8GraphAlarm | 1.3.6.1.4.1.5040.1.2.6.3.1.5 | |||
| INT wtWebioAn8GraphAlarmCount | 1.3.6.1.4.1.5040.1.2.6.3.1.5.1 | INTEGER | read-only | Number of independent alarms. |
| wtWebioAn8GraphAlarmIfTable | 1.3.6.1.4.1.5040.1.2.6.3.1.5.2 | not-accessible | List of alarm indices. | |
| wtWebioAn8GraphAlarmIfEntry | 1.3.6.1.4.1.5040.1.2.6.3.1.5.2.1 | not-accessible | Numbers of the alarms. | |
| INT wtWebioAn8GraphAlarmNo | 1.3.6.1.4.1.5040.1.2.6.3.1.5.2.1.1 | INTEGER | read-only | Alarm number. |
| wtWebioAn8GraphAlarmTable | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3 | not-accessible | List of settings depending on the alarm number. | |
| wtWebioAn8GraphAlarmEntry | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1 | not-accessible | Alarm parameters of the individual alarms. | |
| OCT wtWebioAn8GraphAlarmTrigger | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.1 | OCTET STRING | read-write | Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8 |
| OCT wtWebioAn8GraphAlarmMin | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.2 | OCTET STRING | read-write | Minimum temperature in degrees with maximum 2 decimal places. |
| OCT wtWebioAn8GraphAlarmMax | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.3 | OCTET STRING | read-write | Maximum temperature in degrees with maximum 2 decimal places. |
| OCT wtWebioAn8GraphAlarmHysteresis | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.4 | OCTET STRING | read-write | Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places. |
| OCT wtWebioAn8GraphAlarmDelay | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.5 | OCTET STRING | read-write | Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes). |
| OCT wtWebioAn8GraphAlarmInterval | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.6 | OCTET STRING | read-write | Send interval for alarm messages. |
| OCT wtWebioAn8GraphAlarmEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.7 | OCTET STRING | read-write | Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable |
| OCT wtWebioAn8GraphAlarmEMailAddr | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.8 | OCTET STRING | read-write | E-Mail address for sending the alarm mail to. |
| OCT wtWebioAn8GraphAlarmMailSubject | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.9 | OCTET STRING | read-write | Subject line for alarm mail. |
| OCT wtWebioAn8GraphAlarmMailText | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.10 | OCTET STRING | read-write | Alarm mail text: provides the current temperature; n = 1..8. provides the current time. |
| OCT wtWebioAn8GraphAlarmManagerIP | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.11 | OCTET STRING | read-write | Name or IP address of the SNMP Manager which accepts the trap. |
| OCT wtWebioAn8GraphAlarmTrapText | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.12 | OCTET STRING | read-write | This text is sent in the trap body. |
| OCT wtWebioAn8GraphAlarmMailOptions | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.13 | OCTET STRING | read-write | Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
| OCT wtWebioAn8GraphAlarmTcpIpAddr | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.14 | OCTET STRING | read-write | Name or IP address of the TCP server which accepts the trap. |
| INT wtWebioAn8GraphAlarmTcpPort | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.15 | INTEGER | read-write | Port number of the TCP server which accepts the trap. |
| OCT wtWebioAn8GraphAlarmTcpText | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.16 | OCTET STRING | read-write | This text is sent in the TCP trap body. |
| OCT wtWebioAn8GraphAlarmClearMailSubject | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.17 | OCTET STRING | read-write | Subject line for alarm clear mail. |
| OCT wtWebioAn8GraphAlarmClearMailText | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.18 | OCTET STRING | read-write | Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time. |
| OCT wtWebioAn8GraphAlarmClearTrapText | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.19 | OCTET STRING | read-write | This text is sent in the trap body. |
| OCT wtWebioAn8GraphAlarmClearTcpText | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.20 | OCTET STRING | read-write | This text is sent in the TCP trap body. |
| IP wtWebioAn8GraphAlarmSyslogIpAddr | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.21 | IpAddress | read-write | IP address of the syslog server to which the Webio device should send syslog messages. |
| INT wtWebioAn8GraphAlarmSyslogPort | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.22 | INTEGER | read-write | Port number of the syslog server to which the Webio device should send syslog messages. |
| OCT wtWebioAn8GraphAlarmSyslogText | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.23 | OCTET STRING | read-write | Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
| OCT wtWebioAn8GraphAlarmSyslogClearText | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.24 | OCTET STRING | read-write | Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. |
| OCT wtWebioAn8GraphAlarmFtpDataPort | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.25 | OCTET STRING | read-write | Local data port: 1..65535 or AUTO: the next free port will be assigned. |
| OCT wtWebioAn8GraphAlarmFtpFileName | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.26 | OCTET STRING | read-write | Name of the file including path informations. |
| OCT wtWebioAn8GraphAlarmFtpText | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.27 | OCTET STRING | read-write | Message text to store on the FTP server. |
| OCT wtWebioAn8GraphAlarmFtpClearText | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.28 | OCTET STRING | read-write | Alarm clear message to store on the FTP server. |
| OCT wtWebioAn8GraphAlarmFtpOptions | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.29 | OCTET STRING | read-write | Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused |
| OCT wtWebioAn8GraphAlarmTimerCron | 1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.30 | OCTET STRING | read-write | This entry contains 5 text fields space or tab seperated for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute). |
| wtWebioAn8GraphGraphics | 1.3.6.1.4.1.5040.1.2.6.3.1.6 | |||
| wtWebioAn8GraphGraphicsBase | 1.3.6.1.4.1.5040.1.2.6.3.1.6.1 | |||
| OCT wtWebioAn8GraphGraphicsBaseEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.6.1.1 | OCTET STRING | read-write | Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unused |
| INT wtWebioAn8GraphGraphicsBaseWidth | 1.3.6.1.4.1.5040.1.2.6.3.1.6.1.2 | INTEGER | read-write | Defines the width of the graphic in pixels. |
| INT wtWebioAn8GraphGraphicsBaseHeight | 1.3.6.1.4.1.5040.1.2.6.3.1.6.1.3 | INTEGER | read-write | Defines the height of the graphic in pixels. |
| OCT wtWebioAn8GraphGraphicsBaseFrameColor | 1.3.6.1.4.1.5040.1.2.6.3.1.6.1.4 | OCTET STRING | read-write | Frame color definition in RGB. |
| OCT wtWebioAn8GraphGraphicsBaseBackgroundColor | 1.3.6.1.4.1.5040.1.2.6.3.1.6.1.5 | OCTET STRING | read-write | Background color definition in RGB. |
| INT wtWebioAn8GraphGraphicsBasePollingrate | 1.3.6.1.4.1.5040.1.2.6.3.1.6.1.6 | INTEGER | read-write | Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic. |
| wtWebioAn8GraphGraphicsSelect | 1.3.6.1.4.1.5040.1.2.6.3.1.6.2 | |||
| OCT wtWebioAn8GraphGraphicsSelectDisplaySensorSel | 1.3.6.1.4.1.5040.1.2.6.3.1.6.2.1 | OCTET STRING | read-write | Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8 |
| OCT wtWebioAn8GraphGraphicsSelectDisplayShowExtrem | 1.3.6.1.4.1.5040.1.2.6.3.1.6.2.2 | OCTET STRING | read-write | Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8 |
| wtWebioAn8GraphGraphicsSensorColorTable | 1.3.6.1.4.1.5040.1.2.6.3.1.6.2.3 | not-accessible | List of sensor colors for the praphical presentation. | |
| wtWebioAn8GraphGraphicsSensorColorEntry | 1.3.6.1.4.1.5040.1.2.6.3.1.6.2.3.1 | not-accessible | Numbers of the sensors. | |
| OCT wtWebioAn8GraphGraphicsSensorColor | 1.3.6.1.4.1.5040.1.2.6.3.1.6.2.3.1.1 | OCTET STRING | read-write | Color of the sensors at the praphical presention. |
| OCT wtWebioAn8GraphGraphicsSelectScale | 1.3.6.1.4.1.5040.1.2.6.3.1.6.2.3.1.2 | OCTET STRING | read-write | Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3 : Use Scale 4 Bit 4-7: unused |
| wtWebioAn8GraphGraphicsScale | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3 | |||
| OCT wtWebioAn8GraphGraphicsScaleAutoScaleEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.1 | OCTET STRING | read-write | Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 : Scale 3 Auto scale enable Bit 3 : Scale 4 Auto scale enable Bit 4-7: unused |
| OCT wtWebioAn8GraphGraphicsScaleAutoFitEnable | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.2 | OCTET STRING | read-write | Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Scale 3 Auto fit enable Bit 3 : Scale 4 Auto fit enable Bit 4-7: unused |
| INT wtWebioAn8GraphGraphicsScale1Min | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.3 | INTEGER | read-only | Scale 1: Minimum. |
| INT wtWebioAn8GraphGraphicsScale2Min | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.4 | INTEGER | read-only | Scale 2: Minimum. |
| INT wtWebioAn8GraphGraphicsScale3Min | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.5 | INTEGER | read-only | Scale 3: Minimum. |
| INT wtWebioAn8GraphGraphicsScale4Min | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.6 | INTEGER | read-only | Scale 4: Minimum. |
| INT wtWebioAn8GraphGraphicsScale1Max | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.7 | INTEGER | read-only | Scale 1: Maximum. |
| INT wtWebioAn8GraphGraphicsScale2Max | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.8 | INTEGER | read-only | Scale 2: Maximum. |
| INT wtWebioAn8GraphGraphicsScale3Max | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.9 | INTEGER | read-only | Scale 3: Maximum. |
| INT wtWebioAn8GraphGraphicsScale4Max | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.10 | INTEGER | read-only | Scale 4: Maximum. |
| OCT wtWebioAn8GraphGraphicsScale1Unit | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.11 | OCTET STRING | read-only | Scale 1: Unit. |
| OCT wtWebioAn8GraphGraphicsScale2Unit | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.12 | OCTET STRING | read-only | Scale 2: Unit. |
| OCT wtWebioAn8GraphGraphicsScale3Unit | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.13 | OCTET STRING | read-only | Scale 3: Unit. |
| OCT wtWebioAn8GraphGraphicsScale4Unit | 1.3.6.1.4.1.5040.1.2.6.3.1.6.3.14 | OCTET STRING | read-only | Scale 4: Unit. |
| wtWebioAn8GraphPorts | 1.3.6.1.4.1.5040.1.2.6.3.2 | |||
| wtWebioAn8GraphPortTable | 1.3.6.1.4.1.5040.1.2.6.3.2.1 | not-accessible | List of settings depending on the sensor number. | |
| wtWebioAn8GraphPortEntry | 1.3.6.1.4.1.5040.1.2.6.3.2.1.1 | not-accessible | Sensor parameters for the individual sensors. | |
| OCT wtWebioAn8GraphPortName | 1.3.6.1.4.1.5040.1.2.6.3.2.1.1.1 | OCTET STRING | read-write | Name of the sensor. |
| OCT wtWebioAn8GraphPortText | 1.3.6.1.4.1.5040.1.2.6.3.2.1.1.2 | OCTET STRING | read-write | Description of the sensor. |
| OCT wtWebioAn8GraphPortOffset1 | 1.3.6.1.4.1.5040.1.2.6.3.2.1.1.3 | OCTET STRING | read-write | Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1. |
| OCT wtWebioAn8GraphPortTemperature1 | 1.3.6.1.4.1.5040.1.2.6.3.2.1.1.4 | OCTET STRING | read-write | Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. |
| OCT wtWebioAn8GraphPortOffset2 | 1.3.6.1.4.1.5040.1.2.6.3.2.1.1.5 | OCTET STRING | read-write | Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2. |
| OCT wtWebioAn8GraphPortTemperature2 | 1.3.6.1.4.1.5040.1.2.6.3.2.1.1.6 | OCTET STRING | read-write | Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. |
| OCT wtWebioAn8GraphPortComment | 1.3.6.1.4.1.5040.1.2.6.3.2.1.1.7 | OCTET STRING | read-write | Offset calibration: informations of date, name of operator, reference devices. |
| OCT wtWebioAn8GraphPortSensorSelect | 1.3.6.1.4.1.5040.1.2.6.3.2.1.1.8 | OCTET STRING | read-write | Bin�r kodierte Optionen f�r Sensor: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: ungenutzt |
| wtWebioAn8GraphManufact | 1.3.6.1.4.1.5040.1.2.6.3.3 | |||
| OCT wtWebioAn8GraphMfName | 1.3.6.1.4.1.5040.1.2.6.3.3.1 | OCTET STRING | read-write | Manufacturer company name |
| OCT wtWebioAn8GraphMfAddr | 1.3.6.1.4.1.5040.1.2.6.3.3.2 | OCTET STRING | read-write | Manufacturer address. |
| OCT wtWebioAn8GraphMfHotline | 1.3.6.1.4.1.5040.1.2.6.3.3.3 | OCTET STRING | read-write | Manufacturer hotline. |
| OCT wtWebioAn8GraphMfInternet | 1.3.6.1.4.1.5040.1.2.6.3.3.4 | OCTET STRING | read-write | Manufacturer Internet address. |
| OCT wtWebioAn8GraphMfDeviceTyp | 1.3.6.1.4.1.5040.1.2.6.3.3.5 | OCTET STRING | read-write | Manufacturer device name (model number). |
| OCT wtWebioAn8GraphMfOrderNo | 1.3.6.1.4.1.5040.1.2.6.3.3.6 | OCTET STRING | read-write | Manufacturer part number. |
| wtWebioAn8GraphDiag | 1.3.6.1.4.1.5040.1.2.6.4 | |||
| INT wtWebioAn8GraphDiagErrorCount | 1.3.6.1.4.1.5040.1.2.6.4.1 | INTEGER | read-only | Number of entries in the error memory. |
| OCT wtWebioAn8GraphDiagBinaryError | 1.3.6.1.4.1.5040.1.2.6.4.2 | OCTET STRING | read-only | Error causes coded bit-by-bit. |
| INT wtWebioAn8GraphDiagErrorIndex | 1.3.6.1.4.1.5040.1.2.6.4.3 | INTEGER | read-write | The value of this variable is used as an index to read an error massege from wtWebioAn8GraphDiagErrorMessage. Errors are numbered from 1 to wtWebioAn8GraphDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioAn8GraphDiagErrorMessage. |
| OCT wtWebioAn8GraphDiagErrorMessage | 1.3.6.1.4.1.5040.1.2.6.4.4 | OCTET STRING | read-only | Using wtWebioAn8GraphDiagErrorIndex as an index, the appropriate message is available. |
| INT wtWebioAn8GraphDiagErrorClear | 1.3.6.1.4.1.5040.1.2.6.4.5 | INTEGER | write-only | Writing 1 into this variable clears all diagnosis messages. |
RFC description
Wiesemann & Theis WebGraph 8-channel thermometer MIB for remote temperature monitoring via SNMP.
Start monitoring WebGraph/Web-IO 8-channel thermometer sensor module, environmental monitoring appliance (per-channel temperature/threshold-alarm status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.