VPWR-DC-POWER-MIB :: vpwrAlarmsPresent

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsVPWR-DC-POWER-MIBvpwrAlarmsPresent

vpwrAlarmsPresent

Module: VPWR-DC-POWER-MIB

OID (symbolic): VPWR-DC-POWER-MIB::vpwrAlarmsPresent

OID (numeric): 1.3.6.1.4.1.13858.8.1

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The present number of active alarm conditions.

What is vpwrAlarmsPresent?

Reports the current count of active alarm conditions across the power system, mirroring how many rows currently exist in vpwrAlarmTable; an admin polls this as a quick health check before drilling into the alarm table for detail.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.13858.8.1
snmpwalk -v2c -c public <target> VPWR-DC-POWER-MIB::vpwrAlarmsPresent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.13858.8.1.1
snmpget -v2c -c public <target> VPWR-DC-POWER-MIB::vpwrAlarmsPresent.1

Start monitoring Valere Power DC power plant / rectifier system (voltage/current/rectifier alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VPWR-DC-POWER-MIB::vpwrAlarmsPresent OID value, configure state conditions and alerts, and monitor any Valere Power DC power plant / rectifier system (voltage/current/rectifier alarm status) from a single console.

How to Use in IPNetwork Monitor

Select a Valere Power DC power plant / rectifier system (voltage/current/rectifier alarm status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type vpwrAlarmsPresent into the Find box to locate it in the OID tree, then select it and click OK. The present number of active alarm conditions. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.13858vpwrDcPowerMgtVALERE-DC-POWER-MIB
1.3.6.1.4.1.13858.8vpwrDcPowerAlarmGroupVALERE-DC-POWER-MIB
Numeric OIDNameModule
1.3.6.1.4.1.13858.8.1vpwrAlarmsPresentVPWR-DC-POWER-MIB