All MIBs › UPSMAN
Category: Power and Environmental Monitoring
Description: Manages UPS power management system status, load, battery health, and bypass modes.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is UPSMAN?
UPSMAN is a vendor UPS (uninterruptible power supply) management MIB exposing the core status of a UPS unit, closely paralleling the structure of the standard IETF UPS-MIB (RFC 1628). It reports identity information (model name, UPS ID), battery health metrics, input line conditions, and output load/status, giving a full picture of the power protection subsystem. Its monitoring purpose is explicitly hardware status: battery capacity, voltage, temperature and remaining runtime/lifetime indicate battery health and imminent depletion, while input line voltage/frequency and output load/status reveal whether the UPS is on utility power, on battery, or overloaded/in bypass. It functions as a vendor-specific analog to the standard UPS-MIB rather than depending on it directly. It is typically deployed in data centers and network closets to give NMS platforms early warning of power events and battery degradation before a UPS-protected outage occurs. Network engineers evaluating or troubleshooting this functionality can download the UPSMAN file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in UPSMAN. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Uninterruptible Power Supply (UPS) unit
Monitoring Examples
An operator can poll upsBatteryStatus and upsBatteryCapacity together with upsBatteryRunTimeRemaining to determine whether the UPS battery is healthy and how much runtime is left during a power event. upsInputLineVoltage and upsInputLineFrequence show whether utility power is within normal range, while upsOutputStatus and upsOutputLoad reveal if the UPS has switched to battery or bypass mode and how heavily loaded the output is. A rising upsBatteryTemperature combined with a falling upsBatteryLifeTimeRemaining is a classic early sign of battery degradation requiring replacement before the next outage.
What Can Be Monitored
- battery status and capacity
- battery voltage and temperature
- runtime/lifetime remaining
- input line voltage/frequency
- output status and load
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge | |
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString |
How to Use in IPNetwork Monitor
Example using upsBatteryLifeTimeRemaining OID:
OIDs
RFC description
Uninterruptible Power Supply Management Information Base (RFC 1628) for monitoring and controlling UPS systems through SNMP. Enables remote tracking of battery status, power conditions, alarms, and diagnostic functions on UPS devices.
Start monitoring Uninterruptible Power Supply (UPS) unit (battery capacity/input-line/output-load status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.