| OID symbolic | OID numeric | Type | Access | Description |
| salixM4MIB | 1.3.6.1.4.1.2158.2.5 | | | The MIB describing SALIX specific extensions
to the M4-MIB |
| salixM4MIBTrapPrefix | 1.3.6.1.4.1.2158.2.5.0 | | | |
| NTF salixAtmfM4HwSwDownloadSuccess | 1.3.6.1.4.1.2158.2.5.0.1 | | | Indicates that software was successfully downloaded to
the physical entity identified by the entPhysicalIndex.
For a successful download to a 'salixSysSwDownloadEntry'
the physical entity will identify an instance of a
'salixAtmfM4PlugInUnitEntry' that represents the physical
device that received the download. The 'hrSWInstalledIndex'
represents the instance of the 'salixSysSwDownloadEntry'
or download destination on the physical entity.
For a successful download to a 'salixAtmfM4EquipHolderEntry'
the physical entity will identify an instance of a
'salixAtmfM4EquipHolderEntry' that represents the physical
device that received the download. The 'hrSWInstalledIndex'
represents the instance of the 'salixSysHrSWInstalledEntry'
or source of the download. |
| NTF salixAtmfM4PlugInUnitRedundancyPairCreated | 1.3.6.1.4.1.2158.2.5.0.2 | | | Indicates that a 1:1 redundancy pair was created between
two plug-in units. The salixAtmfM4PlugInUnitRedundancyConfig'
objects identify the 'working' and 'protect' plug-in units
configured as the redundant pair. |
| NTF salixAtmfM4PlugInUnitRedundancyPairDestroyed | 1.3.6.1.4.1.2158.2.5.0.3 | | | Indicates that the 1:1 redundancy pair between the two
plug-in units identified by the
salixAtmfM4PlugInUnitRedundancyConfig objects was
destroyed. |
| NTF salixAtmfM4PlugInUnitRedundancyPairSwitchover | 1.3.6.1.4.1.2158.2.5.0.4 | | | Indicates a switch from the working plug-in unit of the
redundant pair to the protect partner plug-in unit. The
'salixAtmfM4PlugInUnitRedundancyConfig' objects reflect
the redundancy configuration of the plug-in units after
the switchover. The reason for the switchover is
identified by the 'salixAtmfM4TrapSwitchoverReason' object. |
| NTF salixAtmfM4PlugInUnitRedundancyPairStatusChange | 1.3.6.1.4.1.2158.2.5.0.5 | | | Indicates a change in status of the redundant plug-in unit
pair. The 'salixAtmfM4PlugInUnitRedundancyConfig' objects
reflect the current redundancy configuration of the plug-in
units. The 'salixAtmfM4PlugInUnitRedundancyPairStatus' object
identifies the current status of the redundant plug-in unit
pair. |
| salixM4MIBObjects | 1.3.6.1.4.1.2158.2.5.1 | | | |
| salixAtmfM4EquipHolderTable | 1.3.6.1.4.1.2158.2.5.1.2 | | not-accessible | The HNE equipment holder table. This table augments the
atmfM4EquipHolderTable defined in the ATM-FORUM-M4-MIB. |
| salixAtmfM4EquipHolderEntry | 1.3.6.1.4.1.2158.2.5.1.2.1 | | not-accessible | An entry in the HNE equipment holder table. An entry
contains HNE specific equipment holder information not found
in the ATM-FORUM-M4-MIB. |
| INT salixAtmfM4EquipHolderDownloadState | 1.3.6.1.4.1.2158.2.5.1.2.1.1 | INTEGER | read-only | The software download state of the plug-in unit contained
in the equipment holder. This status is only valid if the
equipment holder is a slot. If the equipment holder is not
a slot then the status will be none(1).
none(1) - download not started or not supported
inProgress(2) - download in progress
success(3) - download to plug-in unit successful
aborted(4) - download aborted
failed(5) - download failed |
| OCT salixAtmfM4EquipHolderDownloadStatusMessage | 1.3.6.1.4.1.2158.2.5.1.2.1.2 | OCTET STRING | read-only | Status message that describes the current state of the
download as indicated by the
'salixAtmfM4EquipHolderDownloadState' attribute. |
| salixAtmfM4PlugInUnitTable | 1.3.6.1.4.1.2158.2.5.1.3 | | not-accessible | The HNE plug-in unit table. This table augments the
atmfM4PlugInUnitTable defined in the ATM-FORUM-M4-MIB. |
| salixAtmfM4PlugInUnitEntry | 1.3.6.1.4.1.2158.2.5.1.3.1 | | not-accessible | An entry in the HNE plug-in unit table. An entry contains HNE
specific plug-in information not found in the ATM-FORUM-M4-MIB. |
| STR salixAtmfM4PlugInUnitSerialNumber | 1.3.6.1.4.1.2158.2.5.1.3.1.1 | DisplayString | read-only | The serial number of the plug-in unit. |
| SAL salixAtmfM4PlugInUnitType | 1.3.6.1.4.1.2158.2.5.1.3.1.2 | SalixPlugInUnitType | read-only | The type of plug-in unit loaded in the slot. |
| INT salixAtmfM4PlugInUnitReset | 1.3.6.1.4.1.2158.2.5.1.3.1.3 | INTEGER | read-write | The type of reset to issue to the plug-in unit. The
following types of plug-in units can be reset, 'mpu',
'dpu', 'smu', 'liu' and 'hsf'.
Writing a cold(1) or warm(2) value to this object will
initiate a reset of the plug-in unit. The reset value
will remain until the reset completes. When completed
the reset value will be changed to none(0). The following
are valid reset values:
cold(1) - cold reset initiated
warm(2) - warm reset initiated |
| STR salixAtmfM4PlugInUnitHwRevision | 1.3.6.1.4.1.2158.2.5.1.3.1.4 | DisplayString | read-only | The hardware revision of the plug-in unit. |
| INT salixAtmfM4PlugInUnitLedStatus | 1.3.6.1.4.1.2158.2.5.1.3.1.5 | INTEGER | read-only | The status of the LEDs on the plug-in unit.
The various bit positions are:
1 OK LED is on
2 OK LED is flashing
4 Active LED is on
8 Active LED is flashing
16 Failed LED is on
32 Failed LED is flashing |
| INT salixAtmfM4PlugInUnitRedundancyConfig | 1.3.6.1.4.1.2158.2.5.1.3.1.6 | INTEGER | read-write | When retrieved, this attribute represents the current
redundancy configuration of the specified Plug-In Unit. A value
of 'none' indicates that the specified Plug-In Unit has no
redundant module. A status of either 'working' or 'protect'
indicates that the specified Plug-In Unit is either the
working or protect Plug-In Unit in a redundancy relationship.
When used with the 'salixAtmfM4PlugInUnitRedundancyPartnerModule'
attribute of the 'salixAtfM4PlugInUnitTable', it can be
determined which Plug-In Units are in redudancy relationship
and also the plug-in units role in that relationship (if
they are in a relationship at all).
In addition to using these attributes to get information on
redundant modules, these attributes can also be used to
create redundancy relationships. By setting the
'salixAtmfM4PlugInUnitRedundancyPartnerModule' to a valid PhysicalIndex
and also setting the 'salixAtmfM4PlugInUnitRedundancyConfig' on either of
the plug-in units to 'working' or 'protect' (as the desired
configuration for that plug-in unit), a redundancy pair is
created. Redundancy relationships can be destroyed by
setting the 'salixAtmfM4PlugInUnitRedundancyConfig' of either of the
modules to 'none'.
If a new value of either 'working' or 'protect' is written
to the 'salixAtmfM4PlugInUnitRedundancyConfig' attribute, a switchover
occurs in the system (i.e. the 'working' becomes the
'protect' while the 'protect' becomes the 'working).
NOTE: It is only necessary to set the information on one of
the plug-in unit entries. The information will be
automatically set in the other entry by the system. |
| PHY salixAtmfM4PlugInUnitRedundancyPartnerModule | 1.3.6.1.4.1.2158.2.5.1.3.1.7 | PhysicalIndex | read-write | When retrieved, this attributes represents the current
partner module of a pair of plugins that are in redundancy
relationship. This attribute is only valid when the
'salixAtmfM4PlugInUnitRedundancyConfig' attribute is set to
either 'working' or 'protect'.
Writing to this object can either create a redundancy pair
(if one doesn't already exist) or can cause a manual
changeover of the working module (if there is a new value
written).
NOTE: It is only necessary to set the information on one of
plug-in units entries. The information will be
automatically set in the other entry by the system. |
| INT salixAtmfM4PlugInUnitRedundancyPairStatus | 1.3.6.1.4.1.2158.2.5.1.3.1.8 | INTEGER | read-only | This attribute reflects the status of the redundant
plug-in unit pair:
none(1) - indicates that a 1:1 redundant pair does not exist
with this plug-in unit.
created(2) - indicates that a 1:1 redundant pair was created between
this plug-in unit and the plug-in unit identified
by the 'salixAtmfM4PlugInUnitRedundancyPartnerModule'.
configured(3) indicates that the working module identified by this
1:1 redundant pair is operational.
active(4) - indicates that 1:1 redundancy is active. This
state is entered if both redundant plug-in units
are physically installed with administrative and
operational status as 'up'. |
| OCT salixAtmfM4PlugInUnitRedundancyStatusMessage | 1.3.6.1.4.1.2158.2.5.1.3.1.9 | OCTET STRING | read-only | Status message that describes the current state of the
redundant plug-in unit pair. |
| SAL salixAtmfM4TrapSwitchoverReason | 1.3.6.1.4.1.2158.2.5.1.4 | SalixAtmfM4SwitchoverReasons | accessible-for-notify | This object identifies the reason for the switchover
that occurred between two plug-in units in a redundant
pair. |
| salixM4MIBTraps | 1.3.6.1.4.1.2158.2.5.2 | | | |
| salixM4MIBCompliance | 1.3.6.1.4.1.2158.2.5.3 | | | |
| salixM4Groups | 1.3.6.1.4.1.2158.2.5.3.1 | | | |
| salixM4Group | 1.3.6.1.4.1.2158.2.5.3.1.1 | | | Salix M4 Objects Group |
| salixM4Compliances | 1.3.6.1.4.1.2158.2.5.3.2 | | | |
| salixM4Compliance | 1.3.6.1.4.1.2158.2.5.3.2.1 | | | The basic implementation requirements for the SALIX-M4-MIB. |