SALIX-M4-MIB :: salixAtmfM4PlugInUnitRedundancyConfig

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › SALIX-M4-MIB › salixAtmfM4PlugInUnitRedundancyConfig

salixAtmfM4PlugInUnitRedundancyConfig

Module: SALIX-M4-MIB

OID (symbolic): SALIX-M4-MIB::salixAtmfM4PlugInUnitRedundancyConfig

OID (numeric): 1.3.6.1.4.1.2158.2.5.1.3.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: When retrieved, this attribute represents the current redundancy configuration of the specified Plug-In Unit. A value of 'none' indicates that the specified Plug-In Unit has no redundant module. A status of either 'working' or 'protect' indicates that the specified Plug-In Unit is either the working or protect Plug-In Unit in a redundancy relationship.

When used with the 'salixAtmfM4PlugInUnitRedundancyPartnerModule' attribute of the 'salixAtfM4PlugInUnitTable', it can be determined which Plug-In Units are in redudancy relationship and also the plug-in units role in that relationship (if they are in a relationship at all).

In addition to using these attributes to get information on redundant modules, these attributes can also be used to create redundancy relationships. By setting the 'salixAtmfM4PlugInUnitRedundancyPartnerModule' to a valid PhysicalIndex and also setting the 'salixAtmfM4PlugInUnitRedundancyConfig' on either of the plug-in units to 'working' or 'protect' (as the desired configuration for that plug-in unit), a redundancy pair is created. Redundancy relationships can be destroyed by setting the 'salixAtmfM4PlugInUnitRedundancyConfig' of either of the modules to 'none'.

If a new value of either 'working' or 'protect' is written to the 'salixAtmfM4PlugInUnitRedundancyConfig' attribute, a switchover occurs in the system (i.e. the 'working' becomes the 'protect' while the 'protect' becomes the 'working).

NOTE: It is only necessary to set the information on one of the plug-in unit entries. The information will be automatically set in the other entry by the system.

What is salixAtmfM4PlugInUnitRedundancyConfig?

This read-write object reports and configures this plug-in unit's role in a 1:1 redundancy relationship: working, protect, or none if it has no redundant partner. Admins create a redundancy pair by setting salixAtmfM4PlugInUnitRedundancyPartnerModule to a valid partner and setting this attribute to working or protect on either unit, and can force a manual switchover by writing a new working or protect value, or tear down the pairing by setting it to none. Writing protect(2) to a currently working(1) unit's salixAtmfM4PlugInUnitRedundancyConfig would trigger a switchover, making its redundant partner the new working module.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2158.2.5.1.3.1.6
snmpwalk -v2c -c public <target> SALIX-M4-MIB::salixAtmfM4PlugInUnitRedundancyConfig

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2158.2.5.1.3.1.6.1
snmpget -v2c -c public <target> SALIX-M4-MIB::salixAtmfM4PlugInUnitRedundancyConfig.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2158.2.5.1.3.1.6.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> salixAtmfM4PlugInUnitRedundancyConfig.1

Start monitoring SALIX Technologies media gateway, M4 interface telecom access equipment (M4-MIB conformance extension) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SALIX-M4-MIB::salixAtmfM4PlugInUnitRedundancyConfig OID value, configure state conditions and alerts, and monitor any SALIX Technologies media gateway, M4 interface telecom access equipment (M4-MIB conformance extension) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2158salixTechnologiesSALIX-MIB
1.3.6.1.4.1.2158.2salixGenericSALIX-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2158.2.5salixM4MIBSALIX-M4-MIB
1.3.6.1.4.1.2158.2.5.1salixM4MIBObjectsSALIX-M4-MIB
1.3.6.1.4.1.2158.2.5.1.3salixAtmfM4PlugInUnitTableSALIX-M4-MIB
1.3.6.1.4.1.2158.2.5.1.3.1salixAtmfM4PlugInUnitEntrySALIX-M4-MIB
1.3.6.1.4.1.2158.2.5.1.3.1.6salixAtmfM4PlugInUnitRedundancyConfigSALIX-M4-MIB