SALIX-M4-MIB :: salixAtmfM4PlugInUnitReset

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › SALIX-M4-MIB › salixAtmfM4PlugInUnitReset

salixAtmfM4PlugInUnitReset

Module: SALIX-M4-MIB

OID (symbolic): SALIX-M4-MIB::salixAtmfM4PlugInUnitReset

OID (numeric): 1.3.6.1.4.1.2158.2.5.1.3.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The type of reset to issue to the plug-in unit. The following types of plug-in units can be reset, 'mpu', 'dpu', 'smu', 'liu' and 'hsf'.

Writing a cold(1) or warm(2) value to this object will initiate a reset of the plug-in unit. The reset value will remain until the reset completes. When completed the reset value will be changed to none(0). The following are valid reset values:

cold(1) - cold reset initiated warm(2) - warm reset initiated

What is salixAtmfM4PlugInUnitReset?

This read-write object triggers a reset of this plug-in unit when set to cold(1) or warm(2), automatically reverting to none(0) once the reset completes. Admins use it to remotely reboot a specific module type, mpu, dpu, smu, liu, or hsf, without power-cycling the whole chassis, choosing cold for a full hardware reset or warm for a lighter-weight restart. Setting salixAtmfM4PlugInUnitReset to warm(2) on a misbehaving line interface unit would restart just that module, and the value would return to none(0) once the reset finishes.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2158.2.5.1.3.1.3
snmpwalk -v2c -c public <target> SALIX-M4-MIB::salixAtmfM4PlugInUnitReset

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2158.2.5.1.3.1.3.1
snmpget -v2c -c public <target> SALIX-M4-MIB::salixAtmfM4PlugInUnitReset.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2158.2.5.1.3.1.3.1 i <value>

Start monitoring SALIX Technologies media gateway, M4 interface telecom access equipment (M4-MIB conformance extension) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SALIX-M4-MIB::salixAtmfM4PlugInUnitReset OID value, configure state conditions and alerts, and monitor any SALIX Technologies media gateway, M4 interface telecom access equipment (M4-MIB conformance extension) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2158salixTechnologiesSALIX-MIB
1.3.6.1.4.1.2158.2salixGenericSALIX-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2158.2.5salixM4MIBSALIX-M4-MIB
1.3.6.1.4.1.2158.2.5.1salixM4MIBObjectsSALIX-M4-MIB
1.3.6.1.4.1.2158.2.5.1.3salixAtmfM4PlugInUnitTableSALIX-M4-MIB
1.3.6.1.4.1.2158.2.5.1.3.1salixAtmfM4PlugInUnitEntrySALIX-M4-MIB
1.3.6.1.4.1.2158.2.5.1.3.1.3salixAtmfM4PlugInUnitResetSALIX-M4-MIB