All MIBs › RAID-Adapter-MIB
Category: Storage
Description: Manages RAID adapter configuration, drive status, and logical volume health monitoring.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is RAID-Adapter-MIB?
RAID-Adapter-MIB is a vendor MIB (under the LSI/MegaRAID enterprise branch) for monitoring hardware RAID controller adapters used in servers to manage arrays of physical disks. It exposes an adapter table with firmware and BIOS version, DRAM cache size, rebuild rate, and flush interval, alongside per-adapter operational values such as I/O reads per second and configured limits like maximum concurrent commands and drive spin-up delay/count. This is squarely a hardware-health and storage-status monitoring MIB: it tracks logical drive counts and health, RAID rebuild progress after a disk failure, controller firmware/BIOS version for patch compliance, and I/O throughput, all critical indicators of impending or ongoing storage hardware problems. It is a self-contained vendor (LSI/MegaRAID) MIB with no apparent dependency on IETF standard storage MIBs. It is typically deployed on servers equipped with LSI MegaRAID (or OEM-rebranded, e.g., Dell PERC, IBM ServeRAID) hardware RAID controllers in data centers. Engineers can download the RAID-Adapter-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in RAID-Adapter-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- server hardware RAID controller (LSI/MegaRAID and OEM-rebranded equivalents such as Dell PERC or IBM ServeRAID)
Monitoring Examples
An administrator monitoring array health after a disk replacement would poll numLogicalDrives via adapterTable (keyed by adpAdapterNumber) to confirm the expected number of logical drives are present, and watch rebuildRateInPercent to track how quickly a degraded array is rebuilding onto a replacement disk. firmwareVersion and biosVersion are checked to confirm the controller runs a supported release before a maintenance window, while adpIOReadsPerSec gives a real-time view of storage load that can reveal a bottleneck. A dropping numLogicalDrives count or a stalled rebuildRateInPercent indicates a failing rebuild or an additional disk failure.
What Can Be Monitored
- number of logical drives
- RAID rebuild rate/progress
- controller firmware version
- controller BIOS version
- DRAM cache size
- I/O reads per second
- maximum concurrent commands / spin-up settings
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| enterprises |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| lsi | 1.3.6.1.4.1.3582 | |||
| megaRaid | 1.3.6.1.4.1.3582.1 | |||
| megaRaidMib | 1.3.6.1.4.1.3582.1.1 | |||
| adapterTable | 1.3.6.1.4.1.3582.1.1.1 | not-accessible | A List of Adapter Entries containing Information/Properties about the Adapters in the System. | |
| adapterEntry | 1.3.6.1.4.1.3582.1.1.1.1 | not-accessible | An entry in the Adapter Table. Each Entry corresponds to one Adapter in the System. | |
| INT adpAdapterNumber | 1.3.6.1.4.1.3582.1.1.1.1.1 | INTEGER | read-only | The Adapter Number for this Instance of Adapter Object. This Entry in the Table, contains Information about the Adapter Number specified by this variable. |
| INT numLogicalDrives | 1.3.6.1.4.1.3582.1.1.1.1.2 | INTEGER | read-only | Number of Logical Drives Configured on this Adapter. |
| STR firmwareVersion | 1.3.6.1.4.1.3582.1.1.1.1.3 | DisplayString | read-only | The Firmware Version of the Firmware running on this Adapter. |
| STR biosVersion | 1.3.6.1.4.1.3582.1.1.1.1.4 | DisplayString | read-only | The Bios Version of the BIOS Present in the Flash ROM on this Adapter. |
| INT dramSizeInMB | 1.3.6.1.4.1.3582.1.1.1.1.5 | INTEGER | read-only | Amount of DRAM in Mega Bytes present on this Adapter. |
| INT rebuildRateInPercent | 1.3.6.1.4.1.3582.1.1.1.1.6 | INTEGER | read-write | Rebuild Rate for this Adapter. This determines the Priority of Rebuild/Check-Consistency/Reconstruct Operations versus the Read-Write Operations. |
| INT flushInterval | 1.3.6.1.4.1.3582.1.1.1.1.7 | INTEGER | read-write | Internal Cache Flush Interval for Logical Drives in WriteBack Mode. |
| INT maxConcurrentCmds | 1.3.6.1.4.1.3582.1.1.1.1.8 | INTEGER | read-only | Maximum Concurrent Commands Supported by the Adapter. |
| INT spinupDelay | 1.3.6.1.4.1.3582.1.1.1.1.9 | INTEGER | read-only | This is the Spinup Delay for Spinning Up Physical Drives at Firmware Initialization Time. The Physical Drives are divided into Groups, each containing the number of drives indicated by the spinupCount variable. spinupDelay variable is the amount of delay used before the drives in the next group are issued a SPINUP Command. |
| INT spinupCount | 1.3.6.1.4.1.3582.1.1.1.1.10 | INTEGER | read-only | This is the Spinup Count for Spinning up Physical Drives at Firmware Initialization Time. The Physical Drives are divided into Groups, each containing the number of drives indicated by this variable. All the drives in a group are issued SPINUP Command without any delay. Next group is given SPINUP Commands after a delay indicated by the spinupDelay variable. |
| INT adpIOReadsPerSec | 1.3.6.1.4.1.3582.1.1.1.1.11 | INTEGER | read-only | Number of IO Reads/sec statistics for this adapter. |
| INT adpIOWritesPerSec | 1.3.6.1.4.1.3582.1.1.1.1.12 | INTEGER | read-only | Number of IO Writes/sec statistics for this adapter. |
| INT adpReadKBsPerSec | 1.3.6.1.4.1.3582.1.1.1.1.13 | INTEGER | read-only | Amount of Data Transferred in KBs/sec due to READ Transfers. |
| INT adpWriteKBsPerSec | 1.3.6.1.4.1.3582.1.1.1.1.14 | INTEGER | read-only | Amount of Data Transferred in KBs/sec due to WRITE Transfers. |
| INT adpReadFailuresPerSec | 1.3.6.1.4.1.3582.1.1.1.1.15 | INTEGER | read-only | Number of Read-Failures/sec statistics for this adapter. |
| INT adpWriteFailuresPerSec | 1.3.6.1.4.1.3582.1.1.1.1.16 | INTEGER | read-only | Number of Write-Failures/sec statistics for this adapter. |
| INT scanChannels | 1.3.6.1.4.1.3582.1.1.1.1.17 | INTEGER | read-write | Use this Variable to Discover the Non-Disk Devices attached to the Adapter. Set this Variable to startscan (an integer value of 2) to start the Channel Scanning. |
| STR adpBasePort | 1.3.6.1.4.1.3582.1.1.1.1.18 | DisplayString | read-only | Maximum Concurrent Commands Supported by the Adapter. |
| INT numSCSIChannels | 1.3.6.1.4.1.3582.1.1.1.1.19 | INTEGER | read-only | Maximum number of SCSI Channels Supported by the Adapter. |
| INT numFCLoops | 1.3.6.1.4.1.3582.1.1.1.1.20 | INTEGER | read-only | Number of Fibre channel loops Supported by the Adapter. |
| INT subSystemID | 1.3.6.1.4.1.3582.1.1.1.1.21 | INTEGER | read-only | The PCI sub system ID of this controller |
| INT subSystemVendorID | 1.3.6.1.4.1.3582.1.1.1.1.22 | INTEGER | read-only | The PCI sub system vendor ID of this controller |
| STR productName | 1.3.6.1.4.1.3582.1.1.1.1.23 | DisplayString | read-only | The enriched formation of the controller retrieved from the firmware |
| INT adpSpeed | 1.3.6.1.4.1.3582.1.1.1.1.24 | INTEGER | read-only | Maximum transfer speed of the adapter. |
| logicaldriveTable | 1.3.6.1.4.1.3582.1.1.2 | not-accessible | A List of Logical Drive Entries containing Information/Properties about the Logical Drives Configured in the System. | |
| logicaldriveEntry | 1.3.6.1.4.1.3582.1.1.2.1 | not-accessible | An Entry in the Logical Drive Table. | |
| INT ldAdapterNumber | 1.3.6.1.4.1.3582.1.1.2.1.1 | INTEGER | read-only | The Adapter Number for this Instance of Adapter/LogicalDrive object. |
| INT logicalDriveNumber | 1.3.6.1.4.1.3582.1.1.2.1.2 | INTEGER | read-only | Logical Drive Number for this Logical Drive Entry. |
| INT status | 1.3.6.1.4.1.3582.1.1.2.1.3 | INTEGER | read-write | The Status of this Logical Drive. |
| INT sizeInMB | 1.3.6.1.4.1.3582.1.1.2.1.4 | INTEGER | read-only | The Configured Size of this Logical Drive. |
| INT raidLevel | 1.3.6.1.4.1.3582.1.1.2.1.5 | INTEGER | read-only | Configured Raid Level for this Logical Drive. |
| INT stripeSize | 1.3.6.1.4.1.3582.1.1.2.1.6 | INTEGER | read-only | Configured Stripe Size for this Logical Drive. |
| INT readPolicy | 1.3.6.1.4.1.3582.1.1.2.1.7 | INTEGER | read-write | Configured Read Policy for this Logical Drive. |
| INT writePolicy | 1.3.6.1.4.1.3582.1.1.2.1.8 | INTEGER | read-write | Configured Write Policy for this Logical Drive. |
| INT cachePolicy | 1.3.6.1.4.1.3582.1.1.2.1.9 | INTEGER | read-write | Configured Cache Policy for this Logical Drive. |
| STR enquiryString | 1.3.6.1.4.1.3582.1.1.2.1.10 | DisplayString | read-only | SCSI Inquiry String for this Logical Drive. |
| INT numberOfSpans | 1.3.6.1.4.1.3582.1.1.2.1.11 | INTEGER | read-only | Number of Arrays across which this Logical Drive is Spanning. |
| INT numberOfStripes | 1.3.6.1.4.1.3582.1.1.2.1.12 | INTEGER | read-only | Configured Number of Stripes for this Logical Drive. |
| STR checkConsistencyOrInitializeProgress | 1.3.6.1.4.1.3582.1.1.2.1.13 | DisplayString | read-only | Check Consistency or Initialize Progress for this Logical Drive if the Logical Drive Status is checkconsistencyinprogress or initializeinprogress. |
| INT ldIOReadsPerSec | 1.3.6.1.4.1.3582.1.1.2.1.14 | INTEGER | read-only | Number of IO Reads/sec Statistics for this Logical Drive. |
| INT ldIOWritesPerSec | 1.3.6.1.4.1.3582.1.1.2.1.15 | INTEGER | read-only | Number of IO Writes/sec Statistics for this Logical Drive. |
| INT ldReadKBsPerSec | 1.3.6.1.4.1.3582.1.1.2.1.16 | INTEGER | read-only | Amount of Data Transferred in KBs/sec due to READ Transfers. |
| INT ldWriteKBsPerSec | 1.3.6.1.4.1.3582.1.1.2.1.17 | INTEGER | read-only | Amount of Data Transferred in KBs/sec due to WRITE Transfers. |
| INT ldReadFailuresPerSec | 1.3.6.1.4.1.3582.1.1.2.1.18 | INTEGER | read-only | Number of Read-Failures/sec Statistics for this Logical Drive. |
| INT ldWriteFailuresPerSec | 1.3.6.1.4.1.3582.1.1.2.1.19 | INTEGER | read-only | Number of Write-Failures/sec Statistics for this Logical Drive. |
| physicaldriveTable | 1.3.6.1.4.1.3582.1.1.3 | not-accessible | A List of Physical Device Entries containing Information about the Physical Devices in the System. | |
| physicaldriveEntry | 1.3.6.1.4.1.3582.1.1.3.1 | not-accessible | An Entry in the Physical Drive Table. | |
| INT physAdapterNumber | 1.3.6.1.4.1.3582.1.1.3.1.1 | INTEGER | read-only | The Adapter Number for this Instance of Adapter/Physical-Drive Instance. |
| INT physChannel | 1.3.6.1.4.1.3582.1.1.3.1.2 | INTEGER | read-only | Channel Number at Which this Physical Drive is Present. |
| INT targetID | 1.3.6.1.4.1.3582.1.1.3.1.3 | INTEGER | read-only | SCSI Target ID at Which This Physical Drive is Present. |
| INT state | 1.3.6.1.4.1.3582.1.1.3.1.4 | INTEGER | read-write | Current State of this Physical Drive. |
| STR arrayPosition | 1.3.6.1.4.1.3582.1.1.3.1.5 | DisplayString | read-only | Array is a group of Physical Drives used to Configure Logical Drives. This String Variable has values of the type Ai-j. Example: A1-2 implies that this drive is 2nd member of Array-1. |
| INT sizeMB | 1.3.6.1.4.1.3582.1.1.3.1.6 | INTEGER | read-only | Actual Size of this Physical Drive. |
| INT deviceType | 1.3.6.1.4.1.3582.1.1.3.1.7 | INTEGER | read-only | Device Type of this Physical Drive. |
| STR inquiryString | 1.3.6.1.4.1.3582.1.1.3.1.8 | DisplayString | read-only | SCSI Inquiry String for this Device. |
| INT scsiLevel | 1.3.6.1.4.1.3582.1.1.3.1.9 | INTEGER | read-only | ANSI SCSI Level Conformance of this Device. |
| INT maximumQueueDepth | 1.3.6.1.4.1.3582.1.1.3.1.10 | INTEGER | read-only | The maximum queue depth of this Device. |
| STR rebuildProgress | 1.3.6.1.4.1.3582.1.1.3.1.11 | DisplayString | read-only | Rebuild Progress for this Physical Drive if the Physical Drive State is Rebuild. |
| INT mediumErrors | 1.3.6.1.4.1.3582.1.1.3.1.12 | INTEGER | read-only | Medium Errors Occurred on this Drive Since it was Configured. |
| INT physSlotStatus | 1.3.6.1.4.1.3582.1.1.3.1.13 | INTEGER | read-only | Indicates the status of interest on the drive slot |
| INT physSlotNumber | 1.3.6.1.4.1.3582.1.1.3.1.14 | INTEGER | read-only | SCSI Target Slot Number at Which This Physical Drive is Present. |
| INT otherErrors | 1.3.6.1.4.1.3582.1.1.3.1.15 | INTEGER | read-only | Other Errors Occurred on this Drive Since it was Configured. |
| INT physTermination | 1.3.6.1.4.1.3582.1.1.3.1.16 | INTEGER | read-only | Negotiation Information of the physical drive. This field is applicable only to drives. |
| INT physSpeed | 1.3.6.1.4.1.3582.1.1.3.1.17 | INTEGER | read-only | Transfer speed of the physical drive. This field is applicable only to drives. |
| INT lunNumber | 1.3.6.1.4.1.3582.1.1.3.1.18 | INTEGER | read-only | SCSI LUN ID of this Physical Device |
| channelTable | 1.3.6.1.4.1.3582.1.1.4 | not-accessible | A List of Channel Entries containing Information/Properties about the Channels on the Adapter. | |
| channelEntry | 1.3.6.1.4.1.3582.1.1.4.1 | not-accessible | An Entry in the channel table. | |
| INT chanAdapterNumber | 1.3.6.1.4.1.3582.1.1.4.1.1 | INTEGER | read-only | The Adapter Number for this Instance of Adapter/Channel Instance. |
| INT channel | 1.3.6.1.4.1.3582.1.1.4.1.2 | INTEGER | read-only | Channel Number for this Channel. |
| INT terminations | 1.3.6.1.4.1.3582.1.1.4.1.3 | INTEGER | read-only | Current Terminations Effective on this Channel |
| INT channelStatus | 1.3.6.1.4.1.3582.1.1.4.1.4 | INTEGER | read-only | Current Activity Status (QUIET/ACTIVE) for this Channel. |
| INT channelType | 1.3.6.1.4.1.3582.1.1.4.1.5 | INTEGER | read-only | Type of the channel(RAID/SCSI). |
| fcDeviceTable | 1.3.6.1.4.1.3582.1.1.5 | not-accessible | A List of Entries containing Information about the FC Devices in the System. | |
| fcDeviceEntry | 1.3.6.1.4.1.3582.1.1.5.1 | not-accessible | An Entry in the FC Device Table. | |
| INT fcPhysAdapterNumber | 1.3.6.1.4.1.3582.1.1.5.1.1 | INTEGER | read-only | The Adapter Number for this Instance of Adapter/Physical-Drive Instance. |
| INT fcPhysChannel | 1.3.6.1.4.1.3582.1.1.5.1.2 | INTEGER | read-only | The Channel Number for this Instance of Adapter/Physical-Drive |
| INT fcTargetId | 1.3.6.1.4.1.3582.1.1.5.1.3 | INTEGER | read-only | The Target Number for this Instance of Adapter/Physical-Drive |
| INT fcLoopID_0 | 1.3.6.1.4.1.3582.1.1.5.1.4 | INTEGER | read-only | Loop ID of this FC Drive. |
| INT fcLoopID_1 | 1.3.6.1.4.1.3582.1.1.5.1.5 | INTEGER | read-only | Loop ID of this FC Drive. |
| STR fcWwn | 1.3.6.1.4.1.3582.1.1.5.1.6 | DisplayString | read-only | WWN is the World Wide Name of this FC device |
| INT fcState | 1.3.6.1.4.1.3582.1.1.5.1.7 | INTEGER | read-write | Current State of this Physical Drive. |
| STR fcArrayPosition | 1.3.6.1.4.1.3582.1.1.5.1.8 | DisplayString | read-only | Array is a group of Physical Drives used to Configure Logical Drives. This String Variable has values of the type Ai-j. Example: A1-2 implies that this drive is 2nd member of Array-1. |
| INT fcSizeMB | 1.3.6.1.4.1.3582.1.1.5.1.9 | INTEGER | read-only | Actual Size of this Physical Drive. |
| STR fcInquiryString | 1.3.6.1.4.1.3582.1.1.5.1.10 | DisplayString | read-only | SCSI Inquiry String for this Device. |
| INT fcScsiLevel | 1.3.6.1.4.1.3582.1.1.5.1.11 | INTEGER | read-only | ANSI SCSI Level Conformance of this Device. |
| STR fcRebuildProgress | 1.3.6.1.4.1.3582.1.1.5.1.12 | DisplayString | read-only | Rebuild Progress for this Physical Drive if the Physical Drive State is Rebuild. |
| INT fcMediumErrors | 1.3.6.1.4.1.3582.1.1.5.1.13 | INTEGER | read-only | Medium Errors Occurred on this Drive Since it was Configured. |
| INT fcOtherErrors | 1.3.6.1.4.1.3582.1.1.5.1.14 | INTEGER | read-only | Other Errors Occurred on this Drive Since it was Configured. |
| fcChannelTable | 1.3.6.1.4.1.3582.1.1.6 | not-accessible | A List of FC Channel Entries containing Information about the FC Channels on the Adapter. | |
| fcChannelEntry | 1.3.6.1.4.1.3582.1.1.6.1 | not-accessible | An Entry in the FC channel table. | |
| INT fcChanAdapterNumber | 1.3.6.1.4.1.3582.1.1.6.1.1 | INTEGER | read-only | The Adapter Number for this Instance of Adapter/fc-Channel Instance. |
| INT fcChannel | 1.3.6.1.4.1.3582.1.1.6.1.2 | INTEGER | read-only | The Channel Number for this Instance |
| INT fcLoopNumber | 1.3.6.1.4.1.3582.1.1.6.1.3 | INTEGER | read-only | Loop Index for this fcChannel. |
| INT fcLoopStatus | 1.3.6.1.4.1.3582.1.1.6.1.4 | INTEGER | read-only | Current Activity Status (QUIET/ACTIVE) for this fcChannel. |
| INT fcNumberofDevices | 1.3.6.1.4.1.3582.1.1.6.1.5 | INTEGER | read-only | The number of FC devices in this fcChannel |
| INT fcProcessorType | 1.3.6.1.4.1.3582.1.1.6.1.6 | INTEGER | read-only | The processor type on this fcChannel |
| INT ioReadsPerSec | 1.3.6.1.4.1.3582.1.1.9 | INTEGER | read-only | The Total IO-Reads/Sec Statistics on all Adapters. |
| INT ioWritesPerSec | 1.3.6.1.4.1.3582.1.1.10 | INTEGER | read-only | The Total IO-Writes/Sec Statistics on all Adapters. |
| INT readKBsPerSec | 1.3.6.1.4.1.3582.1.1.11 | INTEGER | read-only | The Total Read KBs Per Second Statistics on all Adapters. |
| INT writeKBsPerSec | 1.3.6.1.4.1.3582.1.1.12 | INTEGER | read-only | The Total Write KBs Per Second Statistics on all Adapters. |
| INT readFailuresPerSec | 1.3.6.1.4.1.3582.1.1.13 | INTEGER | read-only | The Total Read Failures Per Second Statistics on all Adapters. |
| INT writeFailuresPerSec | 1.3.6.1.4.1.3582.1.1.14 | INTEGER | read-only | The Total Write Failures Per Second Statistics on all Adapters. |
| enclConfigurationTable | 1.3.6.1.4.1.3582.1.1.15 | not-accessible | A List of Enclosure Configuration Entries containing Information about the SAF-TE Enclosures in the System. | |
| enclConfigurationEntry | 1.3.6.1.4.1.3582.1.1.15.1 | not-accessible | An Entry in the Enclosure Configuration Table. | |
| INT enclAdapterNumber | 1.3.6.1.4.1.3582.1.1.15.1.1 | INTEGER | read-only | The Adapter Number for this Instance of Adapter/Enclosure Instance. |
| INT enclNumber | 1.3.6.1.4.1.3582.1.1.15.1.2 | INTEGER | read-only | Indicates the enclosure number for this Enclosure. The numbering is w.r.t adapter and not w.r.t Channel |
| INT enclChannel | 1.3.6.1.4.1.3582.1.1.15.1.3 | INTEGER | read-only | Channel Number at Which this Enclosure is Present. |
| INT enclNumDeviceSlots | 1.3.6.1.4.1.3582.1.1.15.1.4 | INTEGER | read-only | Total number of device slots on the channel for this Enclosure |
| INT enclNumFans | 1.3.6.1.4.1.3582.1.1.15.1.5 | INTEGER | read-only | Total number SEP manageable of fans for this Enclosure |
| INT enclNumTempSensors | 1.3.6.1.4.1.3582.1.1.15.1.6 | INTEGER | read-only | Number of SEP manageable Temperature Sensors for this Enclosure |
| INT enclNumPowerSupplies | 1.3.6.1.4.1.3582.1.1.15.1.7 | INTEGER | read-only | Maximum number of SEP manageable Power Supplies for this Enclosure |
| INT enclDoorLockStatus | 1.3.6.1.4.1.3582.1.1.15.1.8 | INTEGER | read-only | Indicates whether this enclosure has door lock installed/locked/unlocked |
| INT enclAudibleAlarm | 1.3.6.1.4.1.3582.1.1.15.1.9 | INTEGER | read-only | Indicates the availability of Audible Alarm with this Enclosure |
| INT enclAlarmStatus | 1.3.6.1.4.1.3582.1.1.15.1.10 | INTEGER | read-only | Indicates whether this Enclosure speaker is ON or OFF |
| INT enclTemperatureScale | 1.3.6.1.4.1.3582.1.1.15.1.11 | INTEGER | read-only | Indicates whether this Enclosure reports temperature in Celsius or Fahrenheit |
| INT enclTotalPowerOnMins | 1.3.6.1.4.1.3582.1.1.15.1.12 | INTEGER | read-only | This indicates the total time in minutes that the RAID device has been powered ON. It is cumulative over the life of the device |
| INT enclTotalPowerOnCycles | 1.3.6.1.4.1.3582.1.1.15.1.13 | INTEGER | read-only | This indicates the count of number of times that the RAID device has been powered ON. It is cumulative over the life of the device |
| enclFanTable | 1.3.6.1.4.1.3582.1.1.16 | not-accessible | A List of SAF-TE Enclosure Fan Entries | |
| enclFanEntry | 1.3.6.1.4.1.3582.1.1.16.1 | not-accessible | An Entry in the Enclosure Fan Table. | |
| INT enclNumberFan | 1.3.6.1.4.1.3582.1.1.16.1.1 | INTEGER | read-only | Enclosure Number at Which this Enclosure with the Fan is Present. |
| INT enclFanIndex | 1.3.6.1.4.1.3582.1.1.16.1.2 | INTEGER | read-only | The instance of the fan in the enclosure for the adapter/channel |
| INT enclFanStatus | 1.3.6.1.4.1.3582.1.1.16.1.3 | INTEGER | read-only | The Status of this fan |
| enclPowerSupplyTable | 1.3.6.1.4.1.3582.1.1.17 | not-accessible | A List of SAF-TE Enclosure Power Supply Entries | |
| enclPowerSupplyEntry | 1.3.6.1.4.1.3582.1.1.17.1 | not-accessible | An Entry in the Enclosure Power Supply Table. | |
| INT enclNumberPower | 1.3.6.1.4.1.3582.1.1.17.1.1 | INTEGER | read-only | enclosure number at Which this Enclosure with the Power Supply is Present. |
| INT enclPowerSupplyIndex | 1.3.6.1.4.1.3582.1.1.17.1.2 | INTEGER | read-only | The instance of the PowerSupply in the enclosure for the adapter/channel |
| INT enclPowerSupplyStatus | 1.3.6.1.4.1.3582.1.1.17.1.3 | INTEGER | read-only | The Status of this PowerSupply |
| enclTempSensorsTable | 1.3.6.1.4.1.3582.1.1.18 | not-accessible | A List of SAF-TE Enclosure Temperature Sensor Entries | |
| enclTempSensorsEntry | 1.3.6.1.4.1.3582.1.1.18.1 | not-accessible | An Entry in the Enclosure Temperature Sensor Table. | |
| INT enclNumberTemp | 1.3.6.1.4.1.3582.1.1.18.1.1 | INTEGER | read-only | enclosure number at Which this Enclosure with the temperature sensor is Present. |
| INT enclTempSensorIndex | 1.3.6.1.4.1.3582.1.1.18.1.2 | INTEGER | read-only | The instance of the temperature sensor indices in the enclosure for the adapter/channel |
| INT enclTemperature | 1.3.6.1.4.1.3582.1.1.18.1.3 | INTEGER | read-only | Indicates the temperature reported by the sensor in degree Fahrenheit |
| raidTraps | 1.3.6.1.4.1.3582.1.1.200 | |||
| NTF rtConfigUpdated | 1.3.6.1.4.1.3582.1.1.200.0.9001 | Adapter-%d: A New Configuration has been written. | ||
| NTF rtPhysicalDriveStateChange | 1.3.6.1.4.1.3582.1.1.200.0.9002 | Adapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s. | ||
| NTF rtLogicalDriveStateChange | 1.3.6.1.4.1.3582.1.1.200.0.9003 | Adapter-%d, Logical Drive-%d: State Changed from %s to %s. | ||
| NTF rtInitializeStarted | 1.3.6.1.4.1.3582.1.1.200.0.9004 | Adapter-%d, Logical Drive-%d: Initialization Started. | ||
| NTF rtInitializeCompleted | 1.3.6.1.4.1.3582.1.1.200.0.9005 | Adapter-%d, Logical Drive-%d: Initialization Completed Successfully. | ||
| NTF rtInitializeAborted | 1.3.6.1.4.1.3582.1.1.200.0.9006 | Adapter-%d, Logical Drive-%d: Initialization Aborted by User. | ||
| NTF rtInitializeFailed | 1.3.6.1.4.1.3582.1.1.200.0.9007 | Adapter-%d, Logical Drive-%d: Initialization Failed. | ||
| NTF rtCheckConsistencyStarted | 1.3.6.1.4.1.3582.1.1.200.0.9008 | Adapter-%d, Logical Drive-%d: Check Consistency Started. | ||
| NTF rtCheckConsistencyCompleted | 1.3.6.1.4.1.3582.1.1.200.0.9009 | Adapter-%d, Logical Drive-%d: Check Consistency Completed. No Inconsistencies Found. | ||
| NTF rtCheckConsistencyAborted | 1.3.6.1.4.1.3582.1.1.200.0.9010 | Adapter-%d, Logical Drive-%d: Check Consistency Aborted by User. | ||
| NTF rtConsistencyCorrected | 1.3.6.1.4.1.3582.1.1.200.0.9011 | Adapter-%d, Logical Drive-%d: Check Consistency Operation Completed. Inconsistencies have been Cured. | ||
| NTF rtCheckConsistencyFailed | 1.3.6.1.4.1.3582.1.1.200.0.9012 | Adapter-%d, Logical Drive-%d: Check Consistency Failed. | ||
| NTF rtReconstructionStarted | 1.3.6.1.4.1.3582.1.1.200.0.9013 | Adapter-%d, Logical Drive-%d: Reconstruction Started. | ||
| NTF rtReconstructionCompleted | 1.3.6.1.4.1.3582.1.1.200.0.9014 | Adapter-%d, Logical Drive-%d: Reconstruction Completed Successfully. | ||
| NTF rtReconstructionFailed | 1.3.6.1.4.1.3582.1.1.200.0.9015 | Adapter-%d, Logical Drive-%d: Reconstruction Failed. | ||
| NTF rtPredictiveFailuresExceeded | 1.3.6.1.4.1.3582.1.1.200.0.9016 | Adapter-%d, Channel-%d, Target-%d: Reported Predictive Failure. Drive Identification String = %s Sense Key = 0x%x, ASC = 0x%x, ASCQ = 0x%x. | ||
| NTF rtPredictiveFailuresFalse | 1.3.6.1.4.1.3582.1.1.200.0.9017 | Adapter-%d, Channel-%d, Target-%d: Reported Failure Prediction Threshold Exceeded [FALSE]. Drive Identification String = %s Sense Key = 0x%x, ASC = 0x%x, ASCQ = 0x%x. | ||
| NTF rtCheckConditionStatus | 1.3.6.1.4.1.3582.1.1.200.0.9018 | Adapter-%d, Channel-%d, Target-%d: Command Completed with Sense-Key-0x%x ASC-0x%x ASCQ-0x%x. | ||
| NTF rtNewDriveInserted | 1.3.6.1.4.1.3582.1.1.200.0.9019 | Adapter-%d, Channel-%d, Target-%d: New Device Inserted. | ||
| NTF rtBatteryMissing | 1.3.6.1.4.1.3582.1.1.200.0.9020 | Adapter-%d: Battery Module is missing. | ||
| NTF rtBatteryVolatageLow | 1.3.6.1.4.1.3582.1.1.200.0.9021 | Adapter-%d: Battery Module Voltage is Low. | ||
| NTF rtBatteryTemperatureHigh | 1.3.6.1.4.1.3582.1.1.200.0.9022 | Adapter-%d: Battery Module Temperature Exceeded Danger Threshold. | ||
| NTF rtPhysicalDriveStateReady | 1.3.6.1.4.1.3582.1.1.200.0.9023 | Adapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s. | ||
| NTF rtPhysicalDriveStateOnline | 1.3.6.1.4.1.3582.1.1.200.0.9024 | Adapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s. | ||
| NTF rtPhysicalDriveStateFailed | 1.3.6.1.4.1.3582.1.1.200.0.9025 | Adapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s. | ||
| NTF rtPhysicalDriveStateRebuild | 1.3.6.1.4.1.3582.1.1.200.0.9026 | Adapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s. | ||
| NTF rtPhysicalDriveStateHotspare | 1.3.6.1.4.1.3582.1.1.200.0.9027 | Adapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s. | ||
| NTF rtLogicalDriveStateOffline | 1.3.6.1.4.1.3582.1.1.200.0.9028 | Adapter-%d, Logical Drive-%d: State Changed from %s to %s. | ||
| NTF rtLogicalDriveStateDegraded | 1.3.6.1.4.1.3582.1.1.200.0.9029 | Adapter-%d, Logical Drive-%d: State Changed from %s to %s. | ||
| NTF rtLogicalDriveStateOptimal | 1.3.6.1.4.1.3582.1.1.200.0.9030 | Adapter-%d, Logical Drive-%d: State Changed from %s to %s. | ||
| NTF rtLogicalDriveStateInitialize | 1.3.6.1.4.1.3582.1.1.200.0.9031 | Adapter-%d, Logical Drive-%d: State Changed from %s to %s. | ||
| NTF rtLogicalDriveStateChkConsist | 1.3.6.1.4.1.3582.1.1.200.0.9032 | Adapter-%d, Logical Drive-%d: State Changed from %s to %s. | ||
| NTF rtEnclTemperatureOutofRange | 1.3.6.1.4.1.3582.1.1.200.0.9033 | Adapter-%d, Channel-%d, Enclosure-%d, Temperature Sensor -%d: Temperature %d is out of Range | ||
| NTF rtEnclTemperatureNormal | 1.3.6.1.4.1.3582.1.1.200.0.9034 | Adapter-%d, Channel-%d, Enclosure-%d, Temperature Sensor -%d: Temperature %d is Normal | ||
| NTF rtEnclFanMalfunction | 1.3.6.1.4.1.3582.1.1.200.0.9035 | Adapter-%d, Channel-%d, Enclosure-%d, Fan-%d: Fan is Malfunctioning | ||
| NTF rtEnclFanOk | 1.3.6.1.4.1.3582.1.1.200.0.9036 | Adapter-%d, Channel-%d, Enclosure-%d, Fan-%d: Fan is operating properly | ||
| NTF rtEnclPowerSupplyMalfunction | 1.3.6.1.4.1.3582.1.1.200.0.9037 | Adapter-%d, Channel-%d, Enclosure-%d, Power Supply-%d: Power Supply is Malfunctioning | ||
| NTF rtEnclPowerSupplyOk | 1.3.6.1.4.1.3582.1.1.200.0.9038 | Adapter-%d, Channel-%d, Enclosure-%d, Power Supply-%d: Power Supply is operating properly | ||
| NTF rtFCLooplStateChange | 1.3.6.1.4.1.3582.1.1.200.0.9040 | Adapter-%d, LoopId-%d: Loop State Changed from %s to %s. | ||
| INT rtAdapterNumber | 1.3.6.1.4.1.3582.1.1.200.1001 | INTEGER | read-only | Adapter Number for which Trap is generated. |
| INT rtLogicalDriveNumber | 1.3.6.1.4.1.3582.1.1.200.1002 | INTEGER | read-only | Logical Drive Number for which Trap is generated. |
| INT rtChannelNumber | 1.3.6.1.4.1.3582.1.1.200.1003 | INTEGER | read-only | Channel Number on the Adapter for which Trap is Generated. |
| INT rtTargetID | 1.3.6.1.4.1.3582.1.1.200.1004 | INTEGER | read-only | Device ID of the Physical Drive for which Trap is Generated. |
| STR rtOldDriveState | 1.3.6.1.4.1.3582.1.1.200.1005 | DisplayString | read-only | Old State of Logical/Physical Drive, when a State Change Trap is Generated. |
| STR rtNewDriveState | 1.3.6.1.4.1.3582.1.1.200.1006 | DisplayString | read-only | New State of Logical/Physical Drive, when a State Change Trap is Generated. |
| INT rtSenseKey | 1.3.6.1.4.1.3582.1.1.200.1007 | INTEGER | read-only | Check Condition Sense-Key reported by Physical Drive for which Trap is Generated. |
| INT rtASC | 1.3.6.1.4.1.3582.1.1.200.1008 | INTEGER | read-only | Check Condition Additional Sense Code (ASC) reported by Physical Drive for which Trap is Generated. |
| INT rtASCQ | 1.3.6.1.4.1.3582.1.1.200.1009 | INTEGER | read-only | Check Condition Additional Sense Code Qualifier (ASCQ) reported by Physical Drive for which Trap is Generated. |
| STR rtDriveVendor | 1.3.6.1.4.1.3582.1.1.200.1010 | DisplayString | read-only | Vendor Identification String from the SCSI Inquiry Data for the Drive. |
| INT rtEnclNumber | 1.3.6.1.4.1.3582.1.1.200.1011 | INTEGER | read-only | Enclosure Number reported by the RAID Controller. |
| INT rtEnclTempSensorIndex | 1.3.6.1.4.1.3582.1.1.200.1012 | INTEGER | read-only | Enclosure Temperature Sensor Number reported by the SEP device |
| INT rtEnclTemperature | 1.3.6.1.4.1.3582.1.1.200.1013 | INTEGER | read-only | Enclosure Temperature in Fahrenheit reported by the SEP device |
| INT rtEnclFanIndex | 1.3.6.1.4.1.3582.1.1.200.1014 | INTEGER | read-only | Enclosure Fan Number reported by the SEP device |
| INT rtEnclPowerSupplyIndex | 1.3.6.1.4.1.3582.1.1.200.1015 | INTEGER | read-only | Enclosure Power Supply Number reported by the SEP device |
| STR rtWWN | 1.3.6.1.4.1.3582.1.1.200.1016 | DisplayString | read-only | The World Wide Name of the FC device whose loop ID or State changes |
| INT rtOldLoopID | 1.3.6.1.4.1.3582.1.1.200.1017 | INTEGER | read-only | Index of the loop before its state changed |
| INT rtNewLoopID | 1.3.6.1.4.1.3582.1.1.200.1018 | INTEGER | read-only | Index of the loop after its state changed |
RFC description
Monitors RAID adapter configuration, logical drives, physical drives, and performance metrics on LSI MegaRAID controllers.
Start monitoring server hardware RAID controller, LSI/MegaRAID and OEM-rebranded equivalents e.g. Dell PERC/IBM ServeRAID with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.