| OID symbolic | OID numeric | Type | Access | Description |
| pegasusSdhMibModule | 1.3.6.1.4.1.6368.2.8 | | | This MIB applies to the PEGASUS SDSL product manufactured by Schmid
Telecom Zurich. The MIB is modelled after the PEM management model, so
object hierarchy and individual variables agree with the PEM client. This
MIB represents an extension to the DS1-MIB and the SONET-MIB. These three
MIB files are used to manage the PEGASUS STM-1 card.
The PEGASUS-SDH-MIB contains five tables:
- stm1CardTable one entry for each STM-1 card configured.
- stm1CardClockTable one entry for each STM-1 card configured.
- ethernetIfTable one entry for each Ethernet interface of a
configured STM-1 card.
- vcTable one entry for each Virtual Container (VC-3/4/12).
- tugConfigTable one entry for each Tributary Unit Group (TUG-3).
Note
- The tables that represent extensions to the DS1-/SINET-MIB use the
ifIndex from IF-MIB (ifTable). |
| stm1CardTable | 1.3.6.1.4.1.6368.2.8.1 | | not-accessible | A table containing stm1 card specific information. |
| stm1CardEntry | 1.3.6.1.4.1.6368.2.8.1.1 | | not-accessible | Row and index definition for stm1 card table. |
| STM stm1CardSlotNumber | 1.3.6.1.4.1.6368.2.8.1.1.1 | STM1SlotNumber | not-accessible | Slot number for stm1 card. |
| STR stm1CardName | 1.3.6.1.4.1.6368.2.8.1.1.2 | DisplayString | read-only | Name of the PEGASUS device. |
| STR stm1CardHardwareVersion | 1.3.6.1.4.1.6368.2.8.1.1.3 | DisplayString | read-only | Hardware version of the STM-1 card. This is also called CHM-number
(it always starts with the letters 'CHM'). The number '404' after
'CHM' identifies the card as a STM-1 card. |
| STR stm1CardFirmwareVersion | 1.3.6.1.4.1.6368.2.8.1.1.4 | DisplayString | read-only | Version number and build date of the firmware running on the line
card. The format is 'major.minor YYYYMMDD hh:mm'. |
| STR stm1CardManufacturer | 1.3.6.1.4.1.6368.2.8.1.1.5 | DisplayString | read-only | Manufacturer of the STM-1 card. |
| STR stm1CardSerialNumber | 1.3.6.1.4.1.6368.2.8.1.1.6 | DisplayString | read-only | Serial number of the line card. Also called HM-number, as it always
starts with 'HM'. Example: HMVSS014810294. |
| MUL stm1CardMultiplexingMode | 1.3.6.1.4.1.6368.2.8.1.1.7 | MultiplexingModeEnum | read-write | Selects the SDH multiplexing mode. Either it is STM1-AU3-VC3 or
STM1-AU4-VC4. |
| OPE stm1CardJ0TraceMonitoring | 1.3.6.1.4.1.6368.2.8.1.1.8 | OperStateEnum | read-write | If trace monitoring is disable no alarm is propagated to PEM and
also no RDI/AIS is inserted. |
| OPE stm1CardJ1TraceMonitoring | 1.3.6.1.4.1.6368.2.8.1.1.9 | OperStateEnum | read-write | If trace monitoring is disable no alarm is propagated to PEM and
also no RDI/AIS is inserted. |
| OPE stm1CardJ2TraceMonitoring | 1.3.6.1.4.1.6368.2.8.1.1.10 | OperStateEnum | read-write | If trace monitoring is disable no alarm is propagated to PEM and
also no RDI/AIS is inserted. |
| TRA stm1CardJ0PathTraceSize | 1.3.6.1.4.1.6368.2.8.1.1.11 | TraceSizeEnum | read-write | Size of the Regenerator Section Trace Message. |
| STR stm1CardJ0PathTraceSend | 1.3.6.1.4.1.6368.2.8.1.1.12 | DisplayString | read-write | Configurable Regenerator Section (RS) Trace Message. |
| STR stm1CardJ0PathTraceExpected | 1.3.6.1.4.1.6368.2.8.1.1.13 | DisplayString | read-write | Regenerator Section (RS) Trace Message that should be received. |
| STR stm1CardJ0PathTraceReceive | 1.3.6.1.4.1.6368.2.8.1.1.14 | DisplayString | read-only | Regenerator Section (RS) Trace Message that is be received. |
| LAS stm1CardLaserOperationMode | 1.3.6.1.4.1.6368.2.8.1.1.15 | LaserOperationModeEnum | read-write | Configuration of the 'Automatic Laser Shutdown' feature. |
| LAS stm1CardLaserState | 1.3.6.1.4.1.6368.2.8.1.1.16 | LaserStateEnum | read-only | Actual state of the laser. |
| OPE stm1CardOperState | 1.3.6.1.4.1.6368.2.8.1.1.17 | OperStateEnum | read-only | The operational state is a status property indicating whether or
not a device is physically installed and working.
enabled The device is partially or fully operable and available
for use.
disabled The device is totally inoperable and unavailable to provide
service. |
| AVA stm1CardAvailabilityState | 1.3.6.1.4.1.6368.2.8.1.1.18 | AvailabilityStatusElem | read-only | The availability status gives more detailed information about
failures within a device. An empty status set means that no error
exists. Possible status are:
in test The device is under test.
failed The device has an internal fault that prevents it from
operating.
power off The device requires power to be applied and is not
powered on.
off line The device requires a routine operation to be performed
to place it online and make it available for use.
off duty The device has been made inactive by an internal control
process in accordance with a predetermined time
schedule.
dependency The device can not operate because some other resource
on which it depends is unavailable.
degraded The device is partially defective but still operable.
not installed The device is not present, or incomplete.
log full The log is full. |
| COM stm1CardMgmtCommState | 1.3.6.1.4.1.6368.2.8.1.1.19 | CommStateEnum | read-only | The Management Comm State indicates the state of the management
connection between the PEM Server and the STM-1 card.
disconnected No connection has been established.
init A connection has freshly been established on
the underlying protocol, but no management
information has been transmitted so far.
identification The connected device is being identified.
check hardware The connected hardware is compared to the one
stored in the configuration.
hardware adaptation If the configured and the existing device do
not match, an adoption is made. The behaviour
in this case can be configured with the 'HW
Adaptation Policy' option.
check program version The program version of the connected hardware
is compared to the one stored in the
configuration.
check config version The configuration version of the connected
hardware is compared to the one stored in the
configuration.
download config If a configuration version mismatch has been
detected and the 'Config Priority' of 'PEGASUS
system' is set to 'Device', the configuration
is downloaded from the device to the PEM
Server.
upload config If a configuration version mismatch has been
detected and the 'Config Priority' of 'PEGASUS
system' is set to 'Server', the configuration
is uploaded from the PEM Server to the device.
status synch The values of the status properties are being
synchronised.
resetting The device is resetting.
inactive The device is connected, but it is inactive,
that is not operational. This may be due to a
hardware mismatch.
active The management connection between the device
and the PEM Server is fully established and
the device is active. |
| NUM stm1CardPRBSGeneratorSink | 1.3.6.1.4.1.6368.2.8.1.1.20 | SdhInterfaceEnum | read-write | Determines, whether the PRBS Generator should be used on the
optical or on the E1 links. |
| NUM stm1CardPRBSAnalyzerSource | 1.3.6.1.4.1.6368.2.8.1.1.21 | SdhInterfaceEnum | read-write | Determines, whether the PRBS Analyzer should be used on the
optical or on the E1 links. |
| PRB stm1CardPRBSPattern | 1.3.6.1.4.1.6368.2.8.1.1.22 | PRBSPatternEnum | read-write | Determines the PRBS Pattern to be used. |
| I32 stm1CardAlarmStatusEx | 1.3.6.1.4.1.6368.2.8.1.1.23 | Integer32 | read-only | This variable indicates the status of STM-1 card, regenerator
section and multiplex section. It's a bitmap represented as a sum.
Therefore multiple alarms can be displayed simultaneously. The value
noAlarm is only set if there isn't any alarm active.
The various bit positions are:
1 No alarm present
-- STM-1 card --
2 Initialization failure
4 Firmware Version Mismatch
8 Maintenance
-- regenerator section RS --
16 Loss of Signal (LOS)
32 Loss of Frame (LOF)
64 Trace ID Mismatch (RS-TIM)
-- multiplex section MS --
128 Alarm Indication Signal (MS-AIS)
256 Remote Defect Indication (MS-RDI, former FERF) |
| stm1CardClockTable | 1.3.6.1.4.1.6368.2.8.2 | | not-accessible | A table containing stm1 card specific clock information. |
| stm1CardClockEntry | 1.3.6.1.4.1.6368.2.8.2.1 | | not-accessible | Row and index definition for stm1 card clock table. |
| CLO stm1CardActiveClockSource | 1.3.6.1.4.1.6368.2.8.2.1.1 | ClockSourceEnum | read-only | Displays which clock sourceis active and used as sync source. |
| CLO stm1CardClockSyncState | 1.3.6.1.4.1.6368.2.8.2.1.2 | ClockSyncStateEnum | read-only | Sync status is OK if RX or Reference clock is valid and used as
active sync source. |
| CLO stm1CardTxLineClockQuality | 1.3.6.1.4.1.6368.2.8.2.1.3 | ClockQualityEnum | read-write | This is the clock quality of the outgoing SDH signal. The default
sets the outgoing quality to the incoming quality. Sometime it may
be useful to set a fix outgoing quality. |
| CLO stm1CardRxClockMode | 1.3.6.1.4.1.6368.2.8.2.1.4 | ClockModeEnum | read-write | If enabled the RX line clock can be used as sync source. |
| CLO stm1CardRxClockPriority | 1.3.6.1.4.1.6368.2.8.2.1.5 | ClockPriorityEnum | read-write | This value has always the opposite value of Reference Clock
Priority. |
| CLO stm1CardRxClockQuality | 1.3.6.1.4.1.6368.2.8.2.1.6 | ClockQualityEnum | read-only | This is the clock quality of the incoming SDH signal. |
| CLO stm1CardRxClockState | 1.3.6.1.4.1.6368.2.8.2.1.7 | ClockStateEnum | read-only | Clock status is valid if a good clock can be found on input
(clock checker). |
| CLO stm1CardReferenceClockMode | 1.3.6.1.4.1.6368.2.8.2.1.8 | ClockModeEnum | read-write | If enabled the Reference clock (V5 card input) can be used as sync
source. |
| CLO stm1CardReferenceClockPriority | 1.3.6.1.4.1.6368.2.8.2.1.9 | ClockPriorityEnum | read-write | This value has always the opposite value of Rx Clock Priority. |
| CLO stm1CardReferenceClockQuality | 1.3.6.1.4.1.6368.2.8.2.1.10 | ClockQualityEnum | read-write | Defines the quality of the reference clock input. This value will
be transmitted in SDH-TX if reference clock is used as active sync
source. |
| CLO stm1CardReferenceClockState | 1.3.6.1.4.1.6368.2.8.2.1.11 | ClockStateEnum | read-only | Clock status is valid if a good clock can be found on input
(clock checker). |
| ethernetIfTable | 1.3.6.1.4.1.6368.2.8.3 | | not-accessible | This table contains additional information concerning the ethernet
interfaces of a STM-1 card. It represents an extension of the
if(X)Table (see IF-MIB). |
| ethernetIfEntry | 1.3.6.1.4.1.6368.2.8.3.1 | | not-accessible | Row and index definition for the ethernetIfTable. |
| CON etherIfConcatenationOption | 1.3.6.1.4.1.6368.2.8.3.1.1 | ConcatenationTypeEnum | read-write | Configuration of the Link Capacity Adjustment Scheme. |
| ETH etherIfEncapsulation | 1.3.6.1.4.1.6368.2.8.3.1.2 | EthernetIfEncapsulationEnum | read-only | This attribute shows the used Ethernet encapsulation protocol. |
| ORD etherIfOrderLevel | 1.3.6.1.4.1.6368.2.8.3.1.3 | OrderLevelEnum | read-only | Only relevant, if SDH Multiplexing Mode (see STM-1 card propertied)
is set to VC3. |
| I32 etherIfAlarmStatus | 1.3.6.1.4.1.6368.2.8.3.1.4 | Integer32 | read-only | This variable indicates the status of an Ethernet Interface. It's
a bitmap represented as a sum. Therefore multiple defects can be
displayed simultaneously. The value noAlarm is only set if there
isn't any alarm.
The various bit positions are (LO = LowOrder, HO = HighOrder):
1 No alarm
2 LO LCAS group identifier mismatch (Rx)
4 HO LCAS group identifier mismatch (Rx)
8 LO VCG exceeds max. differential delay (Rx)
16 HO VCG exceeds max. differential delay (Rx)
32 LO VCG exceeds max. differential delay, calculated over all
containers (Rx)
64 HO VCG exceeds max. differential delay, calculated over all
containers (Rx)
128 Transmit FIFO overflow (Tx)
256 Rx head-of-line blocking FIFO overflow |
| vcTable | 1.3.6.1.4.1.6368.2.8.4 | | not-accessible | This table contains additional information for VC concerning the
multiplexing configuration. It's an extension of the ifTable
(IF-MIB) and the tables of the SONET/SDH-MIB. |
| vcEntry | 1.3.6.1.4.1.6368.2.8.4.1 | | not-accessible | Row and index definition for the vcConfigTable. |
| VIR vcType | 1.3.6.1.4.1.6368.2.8.4.1.1 | VirtualContainerTypeEnum | read-only | Type of Virtual Container (VC). In Pegasus VC-4, VC-3 or VC-12. |
| TUG vcRelatedTUG | 1.3.6.1.4.1.6368.2.8.4.1.2 | TUGIndexOrZero | read-only | Represents the index of the Tributary Unit Group within the
tugConfigTable to which this VC is assigned to. The value depends
also on the multiplexing mode. If the value is 0, there doesn't
exist the relation VC-x to TUG-3. Possible values:
1) multiplexing mode = AU-4:
VC-4: vcRelatedTUG = 0
VC-3/12: vcRelatedTUG = 1..3
2) multiplexing mode = AU-3:
vcRelatedTUG = 0 (no dependency on VC type) |
| NUM vcRelatedVC | 1.3.6.1.4.1.6368.2.8.4.1.3 | InterfaceIndexOrZero | read-only | Represents the index of the Virtual Container within the
ifTable to which this VC is assigned to. The value depends
also on the multiplexing mode. If the value is 0, there doesn't
exist the relation VC-x to VC-x. Possible values:
1) multiplexing mode = AU-4:
vcRelatedVC = 0 (no dependency on VC type)
2) multiplexing mode = AU-3:
VC-3: vcRelatedVC = 0
VC-12: vcRelatedVC = 2031..2033 (example for slot 2) |
| NUM vcAssignedIfIndex | 1.3.6.1.4.1.6368.2.8.4.1.4 | InterfaceIndexOrZero | read-write | Represents the index of the interface within the ifTable (IF-MIB)
that transmits to this VC. |
| STR vcPathTraceSend | 1.3.6.1.4.1.6368.2.8.4.1.5 | DisplayString | read-write | The value of the outgoing J1 Byte VC Path Trace byte message. |
| STR vcPathTraceExpected | 1.3.6.1.4.1.6368.2.8.4.1.6 | DisplayString | read-write | The value of the expected J1 Byte VC Path Trace byte message. |
| STR vcPathTraceReceive | 1.3.6.1.4.1.6368.2.8.4.1.7 | DisplayString | read-only | The value of the incoming J1 Byte VC Path Trace byte message. |
| SIG vcSignalLabelSend | 1.3.6.1.4.1.6368.2.8.4.1.8 | SignalLabel | read-write | The outgoing C2 VC Signal Label (0x02 = TUG structure). |
| SIG vcSignalLabelExpected | 1.3.6.1.4.1.6368.2.8.4.1.9 | SignalLabel | read-write | The expected C2 VC Signal Label (0x02 = TUG structure). |
| SIG vcSignalLabelReceive | 1.3.6.1.4.1.6368.2.8.4.1.10 | SignalLabel | read-only | The incoming C2 VC Signal Label (0x02 = TUG structure). |
| I32 vcAlarmStatus | 1.3.6.1.4.1.6368.2.8.4.1.11 | Integer32 | read-only | This variable indicates the status of the VC. It's a bitmap
represented as a sum. Therefore multiple defects can be displayed
simultaneously. The value noDefect should only be set if there is
no other defect. Some alarms can't occur actually.
The various bit positions are:
1 vcNoDefect
2 vcAlarmAIS
4 vcAlarmLOP
8 vcAlarmRDI
16 vcAlarmUnequipped
32 vcAlarmPLM
64 vcAlarmTIM
128 vcAlarmLOM
256 vcAlarmRFI
512 vcgTxAddTimeout -- not used (deprecated)
1024 vcgTxAdd -- not used (deprecated)
2048 vcgTxRemove -- not used (deprecated)
4096 vcgTxDnu -- not used (deprecated)
8192 vcgDnuOk -- not used (deprecated)
16384 vcgRxAdd -- not used (deprecated)
32768 vcgRxRemove -- not used (deprecated)
65536 vcgRxFail -- not used (deprecated)
131072 vcgLcasCrcError
262144 vcgNonLcasSeqError |
| tugConfigTable | 1.3.6.1.4.1.6368.2.8.5 | | not-accessible | This table contains information concerning Tributary Unit Groups.
If AU-3 structure is used, this table is empty. |
| tugConfigEntry | 1.3.6.1.4.1.6368.2.8.5.1 | | not-accessible | Row and index definition for the tugConfigTable. |
| TUG tugIndex | 1.3.6.1.4.1.6368.2.8.5.1.1 | TUGIndex | not-accessible | Number of the TUG. Range 1..3 |
| NUM tugRelatedVC4 | 1.3.6.1.4.1.6368.2.8.5.1.2 | InterfaceIndex | read-only | |
| ORD tugOrderLevel | 1.3.6.1.4.1.6368.2.8.5.1.3 | OrderLevelEnum | read-write | Individual Order Level of this TUG. If high order is used, the TUG
has exactly one VC-3 and no VC-12s. If low order is used, the TUG
has exactly 21 VC-12 and no VC-3. |
| STR sdhMibRevision | 1.3.6.1.4.1.6368.2.8.6 | DisplayString | read-only | The version number assigned by the version control system. You can query
this from the agent, to find out with which version of the MIB was built
into the agent. The value is also present in copies of the MIB to feed
into SNMP managers. Comparing the version numbers from both sources can
help to detect mismatches. The revision string for this version is:
$Workfile: PEGASUS-SDH-MIB.txt $ $Revision: 14 $ $Date: 3/18/04 6:40p $ |