PEGASUS-SDH-MIB :: vcRelatedVC

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PEGASUS-SDH-MIB › vcRelatedVC

vcRelatedVC

Module: PEGASUS-SDH-MIB

OID (symbolic): PEGASUS-SDH-MIB::vcRelatedVC

OID (numeric): 1.3.6.1.4.1.6368.2.8.4.1.3

Node type: OBJECT-TYPE

Type: InterfaceIndexOrZero

Access: read-only

Description: Represents the index of the Virtual Container within the ifTable to which this VC is assigned to. The value depends also on the multiplexing mode. If the value is 0, there doesn't exist the relation VC-x to VC-x. Possible values: 1) multiplexing mode = AU-4: vcRelatedVC = 0 (no dependency on VC type) 2) multiplexing mode = AU-3: VC-3: vcRelatedVC = 0 VC-12: vcRelatedVC = 2031..2033 (example for slot 2)

What is vcRelatedVC?

This is the index within ifTable of the related Virtual Container this VC is assigned to; in AU-4 mode it's always 0, while in AU-3 mode a VC-3 reads 0 but a VC-12 reads an ifIndex like 2031-2033 pointing to its parent VC-3 (numbers shown are an example for slot 2). Admins use this specifically on AU-3-multiplexed cards to trace a VC-12 tributary back to the VC-3 container carrying it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6368.2.8.4.1.3
snmpwalk -v2c -c public <target> PEGASUS-SDH-MIB::vcRelatedVC

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6368.2.8.4.1.3.1
snmpget -v2c -c public <target> PEGASUS-SDH-MIB::vcRelatedVC.1

Start monitoring Schmid Telecom Pegasus STM-1 microwave/SDSL transport cards (SDH/clock status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PEGASUS-SDH-MIB::vcRelatedVC OID value, configure state conditions and alerts, and monitor any Schmid Telecom Pegasus STM-1 microwave/SDSL transport cards (SDH/clock status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6368schmidtelecomPEGASUS-MIB
1.3.6.1.4.1.6368.2pegasusMibModulePEGASUS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6368.2.8pegasusSdhMibModulePEGASUS-SDH-MIB
1.3.6.1.4.1.6368.2.8.4vcTablePEGASUS-SDH-MIB
1.3.6.1.4.1.6368.2.8.4.1vcEntryPEGASUS-SDH-MIB
1.3.6.1.4.1.6368.2.8.4.1.3vcRelatedVCPEGASUS-SDH-MIB