| OID symbolic | OID numeric | Type | Access | Description |
| peaEquipment | 1.3.6.1.4.1.193.72.600.1 | | | The public ethernet access software supports a number of standard
and proprietary MIBs. This MIB module defines objects for reading/writing
common equipment information. |
| commonObjects | 1.3.6.1.4.1.193.72.600.1.1 | | | |
| versions | 1.3.6.1.4.1.193.72.600.1.1.1 | | | |
| STR sysId | 1.3.6.1.4.1.193.72.600.1.1.1.1 | DisplayString | read-only | This value includes the full name and version
identification of the node software. |
| STR bootSwId | 1.3.6.1.4.1.193.72.600.1.1.1.2 | DisplayString | read-only | This value includes the full name and version
identification of the BOOT software. |
| U32 cfgVer | 1.3.6.1.4.1.193.72.600.1.1.1.3 | Unsigned32 | read-write | The CfgVer will initially be zero, but is set to
the version number defined in the configuration file
received from the tftp server at system start-up. The
management system may use this version number to verify
that the unit contains the correct configuration
parameter values. The management system may update the
version number when configuration parameters are modified. |
| STR activeSwInfo | 1.3.6.1.4.1.193.72.600.1.1.1.4 | DisplayString | read-only | This value represents the software version of the active software part of the node. |
| STR passiveSwInfo | 1.3.6.1.4.1.193.72.600.1.1.1.5 | DisplayString | read-only | This value represents the software version of the passive software part of the node. |
| mainProcessor | 1.3.6.1.4.1.193.72.600.1.1.2 | | | |
| U32 processorLoad | 1.3.6.1.4.1.193.72.600.1.1.2.1 | Unsigned32 | read-only | The percentage of time that the main processor was not idle.
Average over 10 seconds. (almost like hrProcessorLoad in RFC1514). |
| U32 memFree | 1.3.6.1.4.1.193.72.600.1.1.2.2 | Unsigned32 | read-only | The amount of free memory on main processor in percent. |
| U32 memFreeBytes | 1.3.6.1.4.1.193.72.600.1.1.2.3 | Unsigned32 | read-only | The amount of free memory on main processor in bytes. |
| U32 memBuffersUsed | 1.3.6.1.4.1.193.72.600.1.1.2.4 | Unsigned32 | read-only | The total number of memory buffers currently used (Ethernet, ATM & local IP-stack). |
| temperature | 1.3.6.1.4.1.193.72.600.1.1.3 | | | |
| INT tempControlStateEx | 1.3.6.1.4.1.193.72.600.1.1.3.1 | INTEGER | read-only | The state of the temperature control can be:
0 - Low
1 - Normal
2 - High
3 - TooHigh |
| I32 tempValue | 1.3.6.1.4.1.193.72.600.1.1.3.2 | Integer32 | read-only | The temperature value in the node in deg. Celsius. |
| fansStatus | 1.3.6.1.4.1.193.72.600.1.1.4 | | | |
| INT greenFanStatus | 1.3.6.1.4.1.193.72.600.1.1.4.1 | INTEGER | read-only | The status of the fan which is placed closest to the green LED.
For ESN310/ECN320/ECN330, green fan is the fan placed near the front.
Made deprecated. Use the greenFanPerfStatus parameter instead. |
| INT redFanStatus | 1.3.6.1.4.1.193.72.600.1.1.4.2 | INTEGER | read-only | The status of the fan which is placed closest to the red LED.
For ESN310/ECN320/ECN330, red fan is the fan placed near the rear.
Made deprecated. Use the redFanPerfStatus parameter instead. |
| U32 greenFanSpeed | 1.3.6.1.4.1.193.72.600.1.1.4.3 | Unsigned32 | read-only | The speed of the fan, which is placed closest to the
green LED, measured in rpm (revolutions per minute).
For ESN310/ECN320/ECN330, green fan is the fan placed near the front. |
| U32 redFanSpeed | 1.3.6.1.4.1.193.72.600.1.1.4.4 | Unsigned32 | read-only | The speed of the fan, which is placed closest to the
red LED, measured in rpm (revolutions per minute).
For ESN310/ECN320/ECN330, red fan is the fan placed near the rear. |
| INT greenFanPerfStatus | 1.3.6.1.4.1.193.72.600.1.1.4.5 | INTEGER | read-only | The performance status of the fan which is placed closest to the green LED.
For ESN310/ECN320/ECN330, green fan is the fan placed near the front. |
| INT redFanPerfStatus | 1.3.6.1.4.1.193.72.600.1.1.4.6 | INTEGER | read-only | The performance status of the fan which is placed closest to the red LED.
For ESN310/ECN320/ECN330, red fan is the fan placed near the rear. |
| alarmFilter | 1.3.6.1.4.1.193.72.600.1.1.5 | | | |
| INT comAlarmFilter | 1.3.6.1.4.1.193.72.600.1.1.5.1 | INTEGER | read-write | This alarm filter will filter out all communication
alarms with lower severity than the selected.
For example: Selecting minor (1) would filter out all
alarms with warning (0) severity. |
| INT envAlarmFilter | 1.3.6.1.4.1.193.72.600.1.1.5.2 | INTEGER | read-write | This alarm filter will filter out all environment
alarms with lower severity than the selected.
For example: Selecting minor (1) would filter out all
alarms with warning (0) severity. |
| INT equipAlarmFilter | 1.3.6.1.4.1.193.72.600.1.1.5.3 | INTEGER | read-write | This alarm filter will filter out all equipment
alarms with lower severity than the selected.
For example: Selecting minor (1) would filter out all
alarms with warning (0) severity. |
| INT processAlarmFilter | 1.3.6.1.4.1.193.72.600.1.1.5.4 | INTEGER | read-write | This alarm filter will filter out all processing
alarms with lower severity than the selected.
For example: Selecting minor (1) would filter out all
alarms with warning (0) severity. |
| INT qosAlarmFilter | 1.3.6.1.4.1.193.72.600.1.1.5.5 | INTEGER | read-write | This alarm filter will filter out all quality
alarms with lower severity than the selected.
For example: Selecting minor (1) would filter out all
alarms with warning (0) severity. |
| U32 alarmFilterThres | 1.3.6.1.4.1.193.72.600.1.1.5.6 | Unsigned32 | read-write | The threshold value indicates how many alarms that can be filtered by the
node in the time interval indicated by the alarmFilterInterval parameter
before an alarm is sent. If set to 0, the functionality is disabled. |
| U32 alarmFilterInterval | 1.3.6.1.4.1.193.72.600.1.1.5.7 | Unsigned32 | read-write | The value of this parameter indicates the time interval in which the node
can filter a number of alarms indicated by the alarmFilterThres parameter
before an alarm is sent. If set to 0, the functionality is disabled. |
| configurationData | 1.3.6.1.4.1.193.72.600.1.1.6 | | | |
| MAC localMacAddr | 1.3.6.1.4.1.193.72.600.1.1.6.1 | MacAddress | read-only | Unique MAC address of the node. |
| PHY phyMode | 1.3.6.1.4.1.193.72.600.1.1.6.2 | PhyModeType | read-write | Ethernet PHY Mode setting.
The Phy Mode is coded as a bitfield:
* Bit 0: Auto-negotiation. If set, auto-negotiation is OFF else ON.
* Bit 2: Full Duplex control. If set, full duplex operation is NOT allowed.
* Bit 3: 100 Mbit/s control. If set, 100 Mbit/s operation is NOT allowed.
* Bit 4: Half Duplex control. If set, half duplex operation is NOT allowed
* Bit 5: 10 Mbit/s control. If set, 10 Mbit/s operation is NOT allowed.
Examples of PHY Mode values:
* 0x00: Full auto-negotiation.
* 0x20: 100 Mbit/s only. Auto-negotiation between half & full duplex.
* 0x31: Fixed 100 Mbit/s, full duplex only operation.
* 0x25: Fixed 100 Mbit/s, half duplex only operation |
| INT watchDogEnable | 1.3.6.1.4.1.193.72.600.1.1.6.3 | INTEGER | read-only | Enabling of the HW Watchdog.
If 0 (zero), the watchdog is OFF,
else the watchdog is ON. |
| U32 vlanId | 1.3.6.1.4.1.193.72.600.1.1.6.5 | Unsigned32 | read-write | The VLAN ID setting for the management VLAN. |
| U32 vlanPrio | 1.3.6.1.4.1.193.72.600.1.1.6.6 | Unsigned32 | read-write | Specifies the IEEE 802.1Q priority used for the management VLAN. |
| INT vlanTagging | 1.3.6.1.4.1.193.72.600.1.1.6.7 | INTEGER | read-write | If 0, VLAN tagging is off, meaning that VLAN is not used.
If 1, VLAN tagging is used, with the given ID and Prio. |
| OCT bootString | 1.3.6.1.4.1.193.72.600.1.1.6.8 | OCTET STRING | read-only | Text commands for the bootloader. |
| upgradeSW | 1.3.6.1.4.1.193.72.600.1.1.7 | | | |
| STR swFileName | 1.3.6.1.4.1.193.72.600.1.1.7.1 | DisplayString | read-write | The filename to upload to the node.
The path to this file is in the root directory that is specified in the FTP server |
| INT uploadSW | 1.3.6.1.4.1.193.72.600.1.1.7.2 | INTEGER | read-write | Upload new application software to device.
The file which is loaded is indicated by the swFileName parameter.
1 - upload SW to the device and restart afterwards.
2 - upload SW to the device without restarting.
Using GET command the current (inProgress) or last known state (success or failure) are
displayed. |
| STR bootSwFileName | 1.3.6.1.4.1.193.72.600.1.1.7.3 | DisplayString | read-write | The filename of a boot sw image located on the domain file server. This file
name is used by the uploadBootSw. |
| INT uploadBootSw | 1.3.6.1.4.1.193.72.600.1.1.7.4 | INTEGER | read-write | Upload new boot software to this device. The boot sw image must be named by the
bootSwFileName parameter and located on the domain file server, which is the next-server
in the DHCP offer.
Using GET command the current (inProgress) or last known state (success or failure) are
displayed. |
| INT hideInternalInterfaces | 1.3.6.1.4.1.193.72.600.1.1.8 | INTEGER | read-write | The management system can chose to hide all interfaces (RFC1233/RFC2233)
that are irrelevant in the PEM network view (HP OpenView issue).
If 0, Don't hide any interfaces.
If 1, Hide internal interfaces (for example loopback and ATM interfaces). |
| INT restart | 1.3.6.1.4.1.193.72.600.1.1.9 | INTEGER | read-write | When set to 'restart' the node restarts, which includes
loading the SW image and configuration data from the server.
In this way a new SW version can be loaded and/or the configu-
ration data can be updated. |
| INT ledsAltBlink | 1.3.6.1.4.1.193.72.600.1.1.10 | INTEGER | read-write | When the ledsAltBlink is set to ON(1) the
LEDs will start to blink alternatively. |
| INT startCfgVerification | 1.3.6.1.4.1.193.72.600.1.1.11 | INTEGER | read-write | When startCfgVerification is set to verify(1) the node makes a DHCP renew and retrieves
the configuration file from the address of the server just received from DHCP.
The parameters contained in the configuration file overwrites the current settings.
The status of the last issued verification can be read out by reading this MIB variable. |
| INT saveCfgToNvm | 1.3.6.1.4.1.193.72.600.1.1.12 | INTEGER | read-write | When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM.
Using GET command the current (inProgress) or last known state (success or failure) are
displayed. |
| U32 cfgVerificationInterval | 1.3.6.1.4.1.193.72.600.1.1.13 | Unsigned32 | read-write | This is the time in minutes between configuration file verification.
If the value is zero the configuration verification is disabled. |
| INT notifyType | 1.3.6.1.4.1.193.72.600.1.1.14 | INTEGER | read-write | Set the type of the notify sent by the node:
1. Trap
2. Inform |
| identificationData | 1.3.6.1.4.1.193.72.600.1.1.15 | | | |
| deviceIdData | 1.3.6.1.4.1.193.72.600.1.1.15.1 | | | |
| STR productNumber | 1.3.6.1.4.1.193.72.600.1.1.15.1.1 | DisplayString | read-only | Index number that identifies the node. |
| STR revisionState | 1.3.6.1.4.1.193.72.600.1.1.15.1.2 | DisplayString | read-only | Revision State or 'R-state' declaring minor versions.
For example: different types of components or new boot SW. |
| STR functionDesignation | 1.3.6.1.4.1.193.72.600.1.1.15.1.3 | DisplayString | read-only | Number with reference to the handling and use of the product. |
| OCT dateOfProduction | 1.3.6.1.4.1.193.72.600.1.1.15.1.4 | OCTET STRING | read-only | Manufacturing date, describing when the unit has been manufactured,
in terms of a year, month and a day, as described below:
Year code(0000 ..9999) - 2 bytes (LSB,MSB)
Month (1..12)- 1 byte
Day (1 ..31)- 1 byte.
For example, Wednesday June 12, 2002 would be displayed as:
h'02, h'14, h'06, h'0C. |
| OCT dateOfRepair | 1.3.6.1.4.1.193.72.600.1.1.15.1.5 | OCTET STRING | read-only | Repair date, declaring the year, month and day of the latest repair.
The format is described below:
Year code(0000 ..9999) - 2 bytes (LSB,MSB)
Month (1..12)- 1 byte
Day (1 ..31)- 1 byte.
For example, Wednesday June 12, 2002 would be displayed as:
h'02, h'14, h'06, h'0C. |
| STR productionSerialNumber | 1.3.6.1.4.1.193.72.600.1.1.15.1.6 | DisplayString | read-only | Unique serial number, describing the product in terms of a manufacturing
site code and a sequence number. |
| OCT layoutVersionCode | 1.3.6.1.4.1.193.72.600.1.1.15.1.7 | OCTET STRING | read-only | The data layout version that allows the possibility
to interpret stored data differently. |
| OCT idCheckSum | 1.3.6.1.4.1.193.72.600.1.1.15.1.8 | OCTET STRING | read-only | CRC32 Checksum of identification data structure
of the node. |
| microProcessorIdData | 1.3.6.1.4.1.193.72.600.1.1.15.2 | | | |
| STR productNumberMicroProcessor | 1.3.6.1.4.1.193.72.600.1.1.15.2.1 | DisplayString | read-only | Index number that identifies the MicroProcessor board. |
| STR revisionStateMicroProcessor | 1.3.6.1.4.1.193.72.600.1.1.15.2.2 | DisplayString | read-only | Revision State or 'R-state' declaring minor versions.
For example: different types of components or new boot SW. |
| STR functionDesignationMicroProcessor | 1.3.6.1.4.1.193.72.600.1.1.15.2.3 | DisplayString | read-only | Number with reference to the handling and use of the product. |
| OCT dateOfProductionMicroProcessor | 1.3.6.1.4.1.193.72.600.1.1.15.2.4 | OCTET STRING | read-only | Manufacturing date, describing when the unit has been manufactured,
in terms of a year, month and a day, as described below:
Year code(0000 ..9999) - 2 bytes (LSB,MSB)
Month (1..12)- 1 byte
Day (1 ..31)- 1 byte.
For example, Wednesday June 12, 2002 would be displayed as:
h'02, h'14, h'06, h'0C. |
| OCT dateOfRepairMicroProcessor | 1.3.6.1.4.1.193.72.600.1.1.15.2.5 | OCTET STRING | read-only | Repair date, declaring the year, month and day of the latest repair.
The format is described below:
Year code(0000 ..9999) - 2 bytes (LSB,MSB)
Month (1..12)- 1 byte
Day (1 ..31)- 1 byte.
For example, Wednesday June 12, 2002 would be displayed as:
h'02, h'14, h'06, h'0C. |
| STR productionSerialNumberMicroProcessor | 1.3.6.1.4.1.193.72.600.1.1.15.2.6 | DisplayString | read-only | Unique serial number, describing the product in terms of a manufacturing
site code and a sequence number. |
| OCT layoutVersionCodeMicroProcessor | 1.3.6.1.4.1.193.72.600.1.1.15.2.7 | OCTET STRING | read-only | The data layout version that allows the possibility
to interpret stored data differently. |
| OCT idCheckSumMicroProcessor | 1.3.6.1.4.1.193.72.600.1.1.15.2.8 | OCTET STRING | read-only | CRC32 Checksum of identification data structure
for the MicroProcessor board. |
| analogueFrontEndIdData | 1.3.6.1.4.1.193.72.600.1.1.15.3 | | | |
| STR productNumberAnalogueFrontEnd | 1.3.6.1.4.1.193.72.600.1.1.15.3.1 | DisplayString | read-only | Index number that identifies the AFE board. |
| STR revisionStateAnalogueFrontEnd | 1.3.6.1.4.1.193.72.600.1.1.15.3.2 | DisplayString | read-only | Revision State or 'R-state' declaring minor versions.
For example: different types of components or new boot SW. |
| STR functionDesignationAnalogueFrontEnd | 1.3.6.1.4.1.193.72.600.1.1.15.3.3 | DisplayString | read-only | Number with reference to the handling and use of the product. |
| OCT dateOfProductionAnalogueFrontEnd | 1.3.6.1.4.1.193.72.600.1.1.15.3.4 | OCTET STRING | read-only | Manufacturing date, describing when the unit has been manufactured,
in terms of a year, month and a day, as described below:
Year code(0000 ..9999) - 2 bytes (LSB,MSB)
Month (1..12)- 1 byte
Day (1 ..31)- 1 byte.
For example, Wednesday June 12, 2002 would be displayed as:
h'02, h'14, h'06, h'0C. |
| OCT dateOfRepairAnalogueFrontEnd | 1.3.6.1.4.1.193.72.600.1.1.15.3.5 | OCTET STRING | read-only | Repair date, declaring the year, month and day of the latest repair.
The format is described below:
Year code(0000 ..9999) - 2 bytes (LSB,MSB)
Month (1..12)- 1 byte
Day (1 ..31)- 1 byte.
For example, Wednesday June 12, 2002 would be displayed as:
h'02, h'14, h'06, h'0C. |
| STR productionSerialNumberAnalogueFrontEnd | 1.3.6.1.4.1.193.72.600.1.1.15.3.6 | DisplayString | read-only | Unique serial number, describing the product in terms of a manufacturing
site code and a sequence number. |
| OCT layoutVersionCodeAnalogueFrontEnd | 1.3.6.1.4.1.193.72.600.1.1.15.3.7 | OCTET STRING | read-only | The data layout version that allows the possibility
to interpret stored data differently. |
| OCT idCheckSumAnalogueFrontEnd | 1.3.6.1.4.1.193.72.600.1.1.15.3.8 | OCTET STRING | read-only | CRC32 Checksum of identification data structure
for the Analogue Front End board. |
| dcDcConverterIdData | 1.3.6.1.4.1.193.72.600.1.1.15.4 | | | |
| STR productNumberDcDcConverter | 1.3.6.1.4.1.193.72.600.1.1.15.4.1 | DisplayString | read-only | Index number that identifies the DC-DC Converter board. |
| STR revisionStateDcDcConverter | 1.3.6.1.4.1.193.72.600.1.1.15.4.2 | DisplayString | read-only | Revision State or 'R-state' declaring minor versions.
For example: different types of components or new boot SW. |
| STR functionDesignationDcDcConverter | 1.3.6.1.4.1.193.72.600.1.1.15.4.3 | DisplayString | read-only | Number with reference to the handling and use of the product. |
| OCT dateOfProductionDcDcConverter | 1.3.6.1.4.1.193.72.600.1.1.15.4.4 | OCTET STRING | read-only | Manufacturing date, describing when the unit has been manufactured,
in terms of a year, month and a day, as described below:
Year code(0000 ..9999) - 2 bytes (LSB,MSB)
Month (1..12)- 1 byte
Day (1 ..31)- 1 byte.
For example, Wednesday June 12, 2002 would be displayed as:
h'02, h'14, h'06, h'0C. |
| OCT dateOfRepairDcDcConverter | 1.3.6.1.4.1.193.72.600.1.1.15.4.5 | OCTET STRING | read-only | Repair date, declaring the year, month and day of the latest repair.
The format is described below:
Year code(0000 ..9999) - 2 bytes (LSB,MSB)
Month (1..12)- 1 byte
Day (1 ..31)- 1 byte.
For example, Wednesday June 12, 2002 would be displayed as:
h'02, h'14, h'06, h'0C. |
| STR productionSerialNumberDcDcConverter | 1.3.6.1.4.1.193.72.600.1.1.15.4.6 | DisplayString | read-only | Unique serial number, describing the product in terms of a manufacturing
site code and a sequence number. |
| OCT layoutVersionCodeDcDcConverter | 1.3.6.1.4.1.193.72.600.1.1.15.4.7 | OCTET STRING | read-only | The data layout version that allows the possibility
to interpret stored data differently. |
| OCT idCheckSumDcDcConverter | 1.3.6.1.4.1.193.72.600.1.1.15.4.8 | OCTET STRING | read-only | CRC32 Checksum of identification data for the DC-DC Converter board. |
| IP sntpServerIP | 1.3.6.1.4.1.193.72.600.1.1.16 | IpAddress | read-write | The IP address of SNTP server used for time synchronization. |
| U32 snmpKeepAliveTimerTime | 1.3.6.1.4.1.193.72.600.1.1.17 | Unsigned32 | read-write | The interval between SNMP KeepAlive checks. |
| INT allowBroadcastToDux | 1.3.6.1.4.1.193.72.600.1.1.18 | INTEGER | read-write | Enables/disables broadcast to DUX (broadcast beacons).
When the IP DSLAM is restarted one broadcast to DUX is always sent, hereafter
allowBroadcastToDux determines whether broadcast to DUX are sent on a regular
basis. In default settings the broadcast to DUX is enabled.
Note: It is not recommended to disable broadcast to DUX because it might result in reboot of
EDA nodes due to expire of the 'Keep-alive Timer'. For more details consult the Users
Guide. |
| peaMultilink | 1.3.6.1.4.1.193.72.600.1.1.20 | | | |
| INT peaMultilinkMode | 1.3.6.1.4.1.193.72.600.1.1.20.1 | INTEGER | read-write | This defines the mode the multiple network-side links operate in.
singleLink(1) - only one link is used for active data
transfer. This is the only possible
value for devices with a single
network-side link.
linkAggregation(2) - the multiple links are used as one trunk
aggregating the traffic.
redundantConfiguration(3) - only one of the the multiple links is
used for active data transfer, but the
other are kept stand by for resilience
(uses RSTP protocol).
Note: the read value may not match the actual mode during switch over. |
| I32 peaMultilinkPreferredInterface | 1.3.6.1.4.1.193.72.600.1.1.20.2 | Integer32 | read-only | Shows the index of the interface (link) selected for traffic forwarding
whenever there is no other explicit indication on which one to choose.
The interface is selected during boot - it is the interface the device
was booted from. The value is the same as used for interfaces in the
IF-MIB (1-based). |
| peaMultilinkInterfaceTable | 1.3.6.1.4.1.193.72.600.1.1.20.3 | | not-accessible | This is a table of interfaces (links) on the network-side. The table
is indexed by the same interface numbers as used in the IF-MIB (1-based). |
| peaMultilinkInterfaceEntry | 1.3.6.1.4.1.193.72.600.1.1.20.3.1 | | not-accessible | This is an entry of the multilinkInterfaceTable |
| NUM peaMultilinkInterfaceIndex | 1.3.6.1.4.1.193.72.600.1.1.20.3.1.1 | InterfaceIndex | not-accessible | This is the index to the multilinkInterfaceTable. The values
are the same as used in the IF-MIB (1-based). |
| T/F peaMultilinkIsForwarding | 1.3.6.1.4.1.193.72.600.1.1.20.3.1.2 | TruthValue | read-only | This shows if the corresponding interface (link) is forwarding
traffic - true(1) or not - false(2). An interface that is not
forwarding may still carry some service data (e.g. PDUs). |
| T/F peaMultilinkIsUp | 1.3.6.1.4.1.193.72.600.1.1.20.3.1.3 | TruthValue | read-only | This shows if the corresponding interface (link) is up
true(1) or down - false(2). The true(1) value is returned
if the ifOperState of the corresponding port is up.
The false(1) value is returned if the ifOperState of the
corresponding port is NOT up (e.g. down, testing, etc.). |
| INT peaMultilinkForceManagementToUsePreferredInterface | 1.3.6.1.4.1.193.72.600.1.1.20.4 | INTEGER | read-write | Setting this value to 'enabled (1)' forces the management traffic to be sent on
the interface towards the Active ECN thereby overruling the RSTP protocol
for management traffic towards this node.
This enables the node controller to stay in contact with the DSLAM, even if the
link is switched to the other interface by RSTP. |
| INT comboConnector | 1.3.6.1.4.1.193.72.600.1.1.21 | INTEGER | read-only | Tell if a combo connector is mounted for this board. |
| INT blockUnit | 1.3.6.1.4.1.193.72.600.1.1.22 | INTEGER | read-write | Block this unit. When blocked:
- no user traffic is carried out
- no alarms are issued
- it does not allow any configuration
Getting a card out of blocked state can be done by either
sending a restart request to it (MIB or Reset-On-Lan) or
by dismouting and mounting it again.
Setting state to unblock will be ignored. |
| commonTraps | 1.3.6.1.4.1.193.72.600.1.2 | | | |
| traps | 1.3.6.1.4.1.193.72.600.1.2.0 | | | |
| trapsParameters | 1.3.6.1.4.1.193.72.600.1.2.1 | | | |
| ifObjects | 1.3.6.1.4.1.193.72.600.1.5 | | | |
| ifNotifications | 1.3.6.1.4.1.193.72.600.1.6 | | | |
| ifNotificationTypes | 1.3.6.1.4.1.193.72.600.1.6.0 | | | |
| peaEquipmentMibGroups | 1.3.6.1.4.1.193.72.600.1.7 | | | |
| snmpv2Notifications | 1.3.6.1.4.1.193.72.600.1.8 | | | |
| snmpv2NotificationsTypes | 1.3.6.1.4.1.193.72.600.1.8.0 | | | |
| bridgeNotifications | 1.3.6.1.4.1.193.72.600.1.9 | | | |
| bridgeNotificationsTypes | 1.3.6.1.4.1.193.72.600.1.9.0 | | | |
| rmonNotifications | 1.3.6.1.4.1.193.72.600.1.10 | | | |
| rmonNotificationsTypes | 1.3.6.1.4.1.193.72.600.1.10.0 | | | |