tempControlState

Module: PEA-EQUIPMENT

OID (symbolic): PEA-EQUIPMENT::tempControlState

OID (numeric): 1.3.6.1.4.1.193.72.600.1.1.3.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The state of the temperature control can be: 0 - Low 1 - Normal 2 - High 3 - TooHigh

What is tempControlState?

Reports the device's temperature-control state as low(0), normal(1), high(2), or tooHigh(3); tooHigh means the unit is overheating and needs attention before it protectively shuts lines down.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.72.600.1.1.3.1
snmpwalk -v2c -c public <target> PEA-EQUIPMENT::tempControlState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.193.72.600.1.1.3.1.1
snmpget -v2c -c public <target> PEA-EQUIPMENT::tempControlState.1

Start monitoring Ericsson IP DSLAM chassis (system identity/hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PEA-EQUIPMENT::tempControlState OID value, configure state conditions and alerts, and monitor any Ericsson IP DSLAM chassis (system identity/hardware health) from a single console.

How to Use in IPNetwork Monitor

Select an Ericsson IP DSLAM chassis (system identity/hardware health) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type tempControlState into the Find box to locate it in the OID tree, then select it and click OK. The state of the temperature control can be: 0 - Low 1 - Normal 2 - High 3 - TooHigh. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'normal', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.72diaxMIBDXD-SMI
1.3.6.1.4.1.193.72.600peaPEA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.193.72.600.1peaEquipmentPEA-EQUIPMENT
1.3.6.1.4.1.193.72.600.1.1commonObjectsPEA-EQUIPMENT
1.3.6.1.4.1.193.72.600.1.1.3temperaturePEA-EQUIPMENT
1.3.6.1.4.1.193.72.600.1.1.3.1tempControlStatePEA-EQUIPMENT