PDN-MPE-DSLAM-SYSTEM-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PDN-MPE-DSLAM-SYSTEM-MIB

Organization: Paradyne Corporation MIB Working Group

Last Updated: 2004-05-13

Category: DSL and Broadband

Description: Manages system-level objects for the Paradyne MPE DSLAM configuration, slot status, and chassis inventory.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is PDN-MPE-DSLAM-SYSTEM-MIB?

PDN-MPE-DSLAM-SYSTEM-MIB is a Paradyne (PDN) enterprise MIB that extends the standard entPhysicalTable to provide system-level management for the Paradyne MPE DSLAM chassis, covering slot inventory, alarm relays, and physical entity extensions. It exposes objects for external alarm inputs, alarm relay contact state, and extended physical entity attributes such as uptime and location. Administrators use it to monitor the hardware status of DSLAM chassis components, including external alarm contact closures (e.g., door open, temperature threshold) and per-slot/module uptime, which helps detect environmental faults or unexpected card resets. It explicitly builds on and extends the IETF Entity MIB's entPhysicalTable, tying its extended attributes back to standard physical entity indices. It is deployed on Paradyne MPE DSLAM chassis used by telecom carriers to deliver DSL broadband access. Engineers can download the PDN-MPE-DSLAM-SYSTEM-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in PDN-MPE-DSLAM-SYSTEM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Paradyne MPE DSLAM chassis

Monitoring Examples

An operator would poll mpeEntExtAlarmTable/mpeEntExtAlarmEntry and mpeEntExtAlarm to check whether an external alarm input (such as a cabinet door or environmental sensor) has been triggered, and mpeAlarmRelayTable/mpeAlarmRelayInputContactState to see the current state of alarm relay contacts. mpeEntPhysicalExtTable's mpeEntPhysicalExtUpTime would be checked per slot/card to detect an unexpected reset (uptime reset to near zero), while mpeEntPhysicalExtLocation helps map the alarm back to a physical rack/shelf position for dispatch.

What Can Be Monitored

  • external alarm input state
  • alarm relay contact state
  • per-slot/card uptime
  • physical entity location
  • chassis inventory extensions
Imported Objects

From ENTITY-MIB

entPhysicalEntryOBJECT-TYPE
entPhysicalIndexOBJECT-TYPE

From PDN-HEADER-MIB

pdn-mpe

From PDN-MPE-MIB2-MIB

mpeSysObjectIDOBJECT-TYPE

From PDN-TC

ContactState

From SNMP-FRAMEWORK-MIB

SnmpAdminString

From SNMPv2-CONF

MODULE-COMPLIANCE
NOTIFICATION-GROUP
OBJECT-GROUP

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
TimeTicks

From SNMPv2-TC

TEXTUAL-CONVENTION
TruthValue

How to Use in IPNetwork Monitor

Example using mpeEntPhysicalExtUpTime OID:

Select a Paradyne MPE DSLAM chassis (slot inventory/alarm relay, entPhysicalTable extension) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type mpeEntPhysicalExtUpTime into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The time, in hundredths of a second (just like sysUpTime), since the entity was last re-initialized. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a TimeTicks-type OID, Value bounds is the most useful condition here — trigger an alert if the value is unexpectedly low (e.g. under 10 minutes), since that indicates a recent, possibly unplanned, reboot or restart. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Paradyne DSLAM system MIB extending physical entity management with fan, power supply, and alarm monitoring.

Start monitoring Paradyne MPE DSLAM chassis (slot inventory/alarm relay, entPhysicalTable extension) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download PDN-MPE-DSLAM-SYSTEM-MIB