| OID symbolic | OID numeric | Type | Access | Description |
| G32 ac1frequency | 1.3.6.1.4.1.32050.2.2.5 | Gauge32 | read-only | The frequency of the AC input AC1 in 1/100ths
of a Hertz. |
| G32 ac1voltageEx | 1.3.6.1.4.1.32050.2.2.4 | Gauge32 | read-only | The voltage of the AC input AC1 in 1/10ths of
a volt. |
| G32 ac2frequency | 1.3.6.1.4.1.32050.2.2.7 | Gauge32 | read-only | The frequency of the AC input AC2 in 1/100ths
of a Hertz. |
| G32 ac2voltage | 1.3.6.1.4.1.32050.2.2.6 | Gauge32 | read-only | The voltage of the AC input AC2 in 1/10ths of
a volt. |
| TIK currentstandbyruntime | 1.3.6.1.4.1.32050.2.2.24 | TimeTicks | read-write | The amount of time the standby power source has
been running during it's current run. This timer
resets to zero when the standby power source
shuts down. This timer can be reset via the web
interface or by writing 0 to this object. |
| TIK currenttimeonprimary | 1.3.6.1.4.1.32050.2.2.20 | TimeTicks | read-write | The amount of time the transfer switch has been
in the primary state (position) since the most
recent transfer to that state. This timer resets
to zero when the transfer switch leaves the primary
state (position). This timer can be reset via
the web interface or by writing 0 to this object. |
| TIK currenttimeonstandby | 1.3.6.1.4.1.32050.2.2.22 | TimeTicks | read-write | The amount of time the transfer switch has been
in the standby state (position) since the most
recent transfer to that state. This timer resets
to zero when the transfer switch leaves the primary
state (position). This timer can be reset via
the web interface or by writing 0 to this object. |
| T/F enabled | 1.3.6.1.4.1.32050.2.2.35 | TruthValue | read-only | True(1) if the enable input is closed (shorted/on).
False(2) if it is open. |
| TIK laststandbyfailure | 1.3.6.1.4.1.32050.2.2.29 | TimeTicks | read-write | The amount of time since the stall or failure
while running of the standby power source . This
timer resets and starts timing upon a stall/failure
of the power source. This timer can be reset
via the web interface or by writing 0 to this
object. |
| TIK laststandbygracefulstop | 1.3.6.1.4.1.32050.2.2.27 | TimeTicks | read-write | The amount of time since standby power source
was gracefully shutdown. This timer resets and
starts timing upon graceful shutdown of the standby
power source. This timer can be reset via the
web interface or by writing 0 to this object. |
| TIK laststandbyrun | 1.3.6.1.4.1.32050.2.2.26 | TimeTicks | read-write | The amount of time since the standby power source
ran last. This timer resets upon start of the
standby power source and starts timing upon shutdown
of the standby power source. This timer can be
reset via the web interface or by writing 0 to
this object. |
| TIK laststandbyunsuccessfulstart | 1.3.6.1.4.1.32050.2.2.28 | TimeTicks | read-write | The amount of time since the last failed start
of the standby power source . This timer resets
and starts timing upon a unsuccessful start of
the power source. This timer can be reset via
the web interface or by writing 0 to this object. |
| G32 mtr1voltage | 1.3.6.1.4.1.32050.2.2.8 | Gauge32 | read-only | The voltage of the DC input Mtr1 in 1/10ths of
a volt. |
| G32 mtr2voltage | 1.3.6.1.4.1.32050.2.2.9 | Gauge32 | read-only | The voltage of the DC input Mtr2 in 1/10ths of
a volt. |
| I32 numberofstarts | 1.3.6.1.4.1.32050.2.2.18 | Integer32 | read-write | The number of times the secondary power source
has started. This counter increments when the
standby sequence reaches the running state. This
counter can be reset via the web interface or
by writing 0 to this object. |
| I32 numberoftransfers | 1.3.6.1.4.1.32050.2.2.19 | Integer32 | read-write | The number of times the power has transfered from
primary to standby, or back. A complete transfer
cycle from primary to standby and back to primary
will increment this counter twice. This counter
can be reset via the web interface or by writing
0 to this object. |
| packetfluxStandbypowerAllObjects | 1.3.6.1.4.1.32050.2.2.256.1.1 | | | This automatically created object group contains
all those objects that do not belong to any other
OBJECT-GROUP |
| INT powercontrollerstate | 1.3.6.1.4.1.32050.2.2.1 | INTEGER | read-only | The status of the standby power controller. |
| G32 pwr1voltage | 1.3.6.1.4.1.32050.2.2.10 | Gauge32 | read-only | The voltage of the DC input Pwr3 in 1/10ths of
a volt. |
| G32 pwr2voltage | 1.3.6.1.4.1.32050.2.2.11 | Gauge32 | read-only | The voltage of the DC input Pwr2 in 1/10ths of
a volt. |
| I32 recentstalls | 1.3.6.1.4.1.32050.2.2.16 | Integer32 | read-write | The number of times the standby power source has
stalled. This counter resets upon a clean shutdown.
It can also be reset via the web interface or
by writing 0 to this object. |
| I32 recentunsuccessfulstarts | 1.3.6.1.4.1.32050.2.2.14 | Integer32 | read-write | The number of times the standby power source was
not successfully started. This counter resets
upon a successful start. It can also be reset
via the web interface or by writing 0 to this
object. |
| T/F relay1on | 1.3.6.1.4.1.32050.2.2.36 | TruthValue | read-only | True(1) if the Relay 1 ouput is on (C and NO connected).
False(2) if it is off (C and NC connected). |
| T/F relay2on | 1.3.6.1.4.1.32050.2.2.37 | TruthValue | read-only | True(1) if the Relay 2 ouput is on (C and NO connected).
False(2) if it is off (C and NC connected). |
| T/F relay3on | 1.3.6.1.4.1.32050.2.2.38 | TruthValue | read-only | True(1) if the Relay 3 ouput is on (C and NO connected).
False(2) if it is off (C and NC connected). |
| T/F relay4on | 1.3.6.1.4.1.32050.2.2.39 | TruthValue | read-only | True(1) if the Relay 4 ouput is on (C and NO connected).
False(2) if it is off (C and NC connected). |
| T/F relay5on | 1.3.6.1.4.1.32050.2.2.40 | TruthValue | read-only | True(1) if the Relay 5 output is on (C and NO
connected). False(2) if it is off (C and NC connected). |
| T/F relay6on | 1.3.6.1.4.1.32050.2.2.41 | TruthValue | read-only | True(1) if the Relay 6 output is on (C and NO
connected). False(2) if it is off (C and NC connected). |
| T/F relay7on | 1.3.6.1.4.1.32050.2.2.42 | TruthValue | read-only | True(1) if the Relay 7 output is on (C and NO
connected). False(2) if it is off (C and NC connected). |
| T/F ruleexercisestandby | 1.3.6.1.4.1.32050.2.2.47 | TruthValue | read-only | True(1) if the exercise standby without transfer
rule is true. False(2) if it is not. |
| T/F rulereturnprimary | 1.3.6.1.4.1.32050.2.2.44 | TruthValue | read-only | True(1) if the return to primary rule is true.
False(2) if it is not. |
| T/F rulestandbygood | 1.3.6.1.4.1.32050.2.2.45 | TruthValue | read-only | True(1) if the standby power good rule is true.
False(2) if it is not. |
| T/F rulestopstandby | 1.3.6.1.4.1.32050.2.2.46 | TruthValue | read-only | True(1) if the stop standby and consider it failed
rule is true. False(2) if it is not. |
| T/F ruleswitchstandby | 1.3.6.1.4.1.32050.2.2.43 | TruthValue | read-only | True(1) if the switch to standby rule is true.
False(2) if it is not. |
| I32 shuntvoltage | 1.3.6.1.4.1.32050.2.2.12 | Integer32 | read-only | The voltage of the DC input Shunt in 1/10ths of
a millivolt. Can be negative. |
| standbypower | 1.3.6.1.4.1.32050.2.2 | | | MIB for the PacketFlux Standby Power Controller |
| standbypowerConformance | 1.3.6.1.4.1.32050.2.2.256 | | | |
| standbypowerGroups | 1.3.6.1.4.1.32050.2.2.256.1 | | | |
| INT standbypowerstate | 1.3.6.1.4.1.32050.2.2.3 | INTEGER | read-only | The current state in the standby power sequence. |
| T/F switch1closed | 1.3.6.1.4.1.32050.2.2.30 | TruthValue | read-only | True(1) if the Switch 1 input is closed (shorted/on).
False(2) if it is open. |
| T/F switch2closed | 1.3.6.1.4.1.32050.2.2.31 | TruthValue | read-only | True(1) if the Switch 2 input is closed (shorted/on).
False(2) if it is open. |
| T/F switch3closed | 1.3.6.1.4.1.32050.2.2.32 | TruthValue | read-only | True(1) if the Switch 3 input is closed (shorted/on).
False(2) if it is open. |
| T/F switch4closed | 1.3.6.1.4.1.32050.2.2.33 | TruthValue | read-only | True(1) if the Switch 4 input is closed (shorted/on).
False(2) if it is open. |
| T/F switch5closed | 1.3.6.1.4.1.32050.2.2.34 | TruthValue | read-only | True(1) if the Switch 5 input is closed (shorted/on).
False(2) if it is open. |
| G32 temperature | 1.3.6.1.4.1.32050.2.2.13 | Gauge32 | read-only | The temperature of the onboard temperature sensor
in 1/10ths of a degree centigrade. |
| I32 totalstalls | 1.3.6.1.4.1.32050.2.2.17 | Integer32 | read-write | The number of times the standby power source has
stalled. This counter DOES NOT reset upon a clean
shutdown. It can be reset via the web interface
or by writing 0 to this object. |
| TIK totalstandbyruntime | 1.3.6.1.4.1.32050.2.2.25 | TimeTicks | read-write | The amount of time the standby power source has
been running since power on or the last reset
of this counter. This timer does not automatically
reset. This timer can be reset via the web interface
or by writing 0 to this object. |
| TIK totaltimeonprimary | 1.3.6.1.4.1.32050.2.2.21 | TimeTicks | read-write | The amount of time the transfer switch has been
in the primary state (position) since power on
or the last reset of this counter. This timer
does not automatically reset. This timer can
be reset via the web interface or by writing
0 to this object. |
| TIK totaltimeonstandby | 1.3.6.1.4.1.32050.2.2.23 | TimeTicks | read-write | The amount of time the transfer switch has been
in the standby state (position) since power on
or the last reset of this counter. This timer
does not automatically reset. This timer can
be reset via the web interface or by writing
0 to this object. |
| I32 totalunsuccessfulstarts | 1.3.6.1.4.1.32050.2.2.15 | Integer32 | read-write | The number of times the standby power source was
not successfully started. This counter DOES NOT
reset upon a successful start. It can be reset
via the web interface or by writing 0 to this
object. |
| INT transferswitchstate | 1.3.6.1.4.1.32050.2.2.2 | INTEGER | read-only | The current state in the transfer sequence. |
| T/F webcontrol1 | 1.3.6.1.4.1.32050.2.2.48 | TruthValue | read-write | True(1) if the webcontrol 1 virtual toggle switch
is in the on position. False(2) if it is not.
This value can be written to affect the position
of the toggle switch. |
| T/F webcontrol2 | 1.3.6.1.4.1.32050.2.2.49 | TruthValue | read-write | True(1) if the webcontrol 2 virtual toggle switch
is in the on position. False(2) if it is not.
This value can be written to affect the position
of the toggle switch. |
| T/F webcontrol3 | 1.3.6.1.4.1.32050.2.2.50 | TruthValue | read-write | True(1) if the webcontrol 3 virtual toggle switch
is in the on position. False(2) if it is not.
This value can be written to affect the position
of the toggle switch. |
| T/F webcontrol4 | 1.3.6.1.4.1.32050.2.2.51 | TruthValue | read-write | True(1) if the webcontrol 4 virtual toggle switch
is in the on position. False(2) if it is not.
This value can be written to affect the position
of the toggle switch. |
| T/F webcontrol5 | 1.3.6.1.4.1.32050.2.2.52 | TruthValue | read-write | True(1) if the webcontrol 5 virtual toggle switch
is in the on position. False(2) if it is not.
This value can be written to affect the position
of the toggle switch. |
| T/F webcontrol6 | 1.3.6.1.4.1.32050.2.2.53 | TruthValue | read-write | True(1) if the webcontrol 6 virtual toggle switch
is in the on position. False(2) if it is not.
This value can be written to affect the position
of the toggle switch. |
| T/F webcontrol7 | 1.3.6.1.4.1.32050.2.2.54 | TruthValue | read-write | True(1) if the webcontrol 7 virtual toggle switch
is in the on position. False(2) if it is not.
This value can be written to affect the position
of the toggle switch. |
| T/F webcontrol8 | 1.3.6.1.4.1.32050.2.2.55 | TruthValue | read-write | True(1) if the webcontrol 8 virtual toggle switch
is in the on position. False(2) if it is not.
This value can be written to affect the position
of the toggle switch. |