PACKETFLUX-STANDBYPOWER

MIB Reference — IPNetwork Monitor · Updated September 09, 2026

All MIBsPACKETFLUX-STANDBYPOWER

Organization: PacketFlux Technologies

Last Updated: 2013-06-04

Category: UPS/Power

Description: Monitors standby power system status, battery state, and alarm conditions on PacketFlux Technologies devices.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is PACKETFLUX-STANDBYPOWER?

PACKETFLUX-STANDBYPOWER is a PacketFlux Technologies proprietary MIB (built on PACKETFLUX-SMI) for the PacketFlux Standby Power Controller, managing automatic generator/transfer-switch failover at remote broadcast/telecom sites. Its objects cover power-controller/transfer-switch/standby-power state, AC1/AC2 voltage/frequency, meter 1/2 voltage, PWR 1/2 voltage, shunt voltage, temperature, recent/total unsuccessful-start and stall counts, start/transfer counts, and current/total time on primary and standby power (plus current standby runtime). As a status/performance MIB it lets an administrator confirm generator health and watch failover history on a PacketFlux Standby Power Controller. It is deployed on PacketFlux Technologies Standby Power Controller equipment. Engineers can download the PACKETFLUX-STANDBYPOWER file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in PACKETFLUX-STANDBYPOWER. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • PacketFlux Technologies Standby Power Controller equipment

Monitoring Examples

An administrator checks totalunsuccessfulstarts and standbypowerstate to confirm generator reliability and current failover state on a PacketFlux Standby Power Controller.

What Can Be Monitored

  • generator/transfer-switch health and failover history
Imported Objects

From PACKETFLUX-SMI

packetfluxMgmtOBJECT-IDENTITY

From SNMPv2-CONF

OBJECT-GROUP

From SNMPv2-SMI

Gauge32
Integer32
MODULE-IDENTITY
OBJECT-TYPE
TimeTicks

From SNMPv2-TC

TruthValue

How to Use in IPNetwork Monitor

Example using ac1voltage OID:

Select a PacketFlux Technologies Standby Power Controller as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ac1voltage into the Find box to locate it in the OID tree, then select it and click OK. The voltage of the AC input AC1 in 1/10ths of a volt. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline, since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Monitors standby power controller status and transfer switch states for PacketFlux power management systems.

Start monitoring PacketFlux Technologies Standby Power Controller with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download PACKETFLUX-STANDBYPOWER