ac1voltage

Module: PACKETFLUX-STANDBYPOWER

OID (symbolic): PACKETFLUX-STANDBYPOWER::ac1voltage

OID (numeric): 1.3.6.1.4.1.32050.2.2.4

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The voltage of the AC input AC1 in 1/10ths of a volt.

What is ac1voltage?

The measured voltage of AC input 1 (the primary utility feed), reported in tenths of a volt, so a value of 1200 means 120.0V -- watched to confirm utility power is present and within range before a transfer decision is made.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.32050.2.2.4
snmpwalk -v2c -c public <target> PACKETFLUX-STANDBYPOWER::ac1voltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.32050.2.2.4.1
snmpget -v2c -c public <target> PACKETFLUX-STANDBYPOWER::ac1voltage.1

Start monitoring PacketFlux Technologies Standby Power Controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PACKETFLUX-STANDBYPOWER::ac1voltage OID value, configure state conditions and alerts, and monitor any PacketFlux Technologies Standby Power Controller from a single console.

How to Use in IPNetwork Monitor

Select a PacketFlux Technologies Standby Power Controller as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ac1voltage into the Find box to locate it in the OID tree, then select it and click OK. The voltage of the AC input AC1 in 1/10ths of a volt. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline, since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.32050packetfluxPACKETFLUX-SMI
1.3.6.1.4.1.32050.2packetfluxMgmtPACKETFLUX-SMI
Numeric OIDNameModule
1.3.6.1.4.1.32050.2.2standbypowerPACKETFLUX-STANDBYPOWER
1.3.6.1.4.1.32050.2.2.4ac1voltagePACKETFLUX-STANDBYPOWER