PACKETFLUX-STANDBYPOWER :: webcontrol2

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsPACKETFLUX-STANDBYPOWERwebcontrol2

webcontrol2

Module: PACKETFLUX-STANDBYPOWER

OID (symbolic): PACKETFLUX-STANDBYPOWER::webcontrol2

OID (numeric): 1.3.6.1.4.1.32050.2.2.49

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: True(1) if the webcontrol 2 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle switch.

What is webcontrol2?

A writable virtual toggle switch (webcontrol 2): reads true when the switch is in the on position, false when off, and can be written by an admin to flip the virtual switch.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.32050.2.2.49
snmpwalk -v2c -c public <target> PACKETFLUX-STANDBYPOWER::webcontrol2

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.32050.2.2.49.1
snmpget -v2c -c public <target> PACKETFLUX-STANDBYPOWER::webcontrol2.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.32050.2.2.49.1 s <value>

Start monitoring PacketFlux Technologies Standby Power Controller with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PACKETFLUX-STANDBYPOWER::webcontrol2 OID value, configure state conditions and alerts, and monitor any PacketFlux Technologies Standby Power Controller from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.32050packetfluxPACKETFLUX-SMI
1.3.6.1.4.1.32050.2packetfluxMgmtPACKETFLUX-SMI
Numeric OIDNameModule
1.3.6.1.4.1.32050.2.2standbypowerPACKETFLUX-STANDBYPOWER
1.3.6.1.4.1.32050.2.2.49webcontrol2PACKETFLUX-STANDBYPOWER