OMNI-gx2RSW200-MIB :: rxgx2Rsw200bHoldTimeData

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2RSW200-MIB › rxgx2Rsw200bHoldTimeData

rxgx2Rsw200bHoldTimeData

Module: OMNI-gx2RSW200-MIB

OID (symbolic): OMNI-gx2RSW200-MIB::rxgx2Rsw200bHoldTimeData

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.8.6.5.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.

What is rxgx2Rsw200bHoldTimeData?

Read-write 32-bit integer that packs validation data and a hold-time value (0 to 1300 seconds) used to suppress noisy, short-lived alarm transitions on the module's analog objects; an admin raises this value to make an alarm wait longer before clearing/re-triggering on flapping readings.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.8.6.5.3
snmpwalk -v2c -c public <target> OMNI-gx2RSW200-MIB::rxgx2Rsw200bHoldTimeData

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.8.6.5.3.1
snmpget -v2c -c public <target> OMNI-gx2RSW200-MIB::rxgx2Rsw200bHoldTimeData.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.8.6.5.3.1 i <value>

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 RSW200 200 MHz RF switch module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2RSW200-MIB::rxgx2Rsw200bHoldTimeData OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 RSW200 200 MHz RF switch module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.8gx2Rsw200GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.8.6gx2Rsw200bHoldTimeTableOMNI-gx2RSW200-MIB
1.3.6.1.4.1.1166.6.1.2.8.6.5gx2Rsw200bHoldTimeEntryOMNI-gx2RSW200-MIB
1.3.6.1.4.1.1166.6.1.2.8.6.5.3rxgx2Rsw200bHoldTimeDataOMNI-gx2RSW200-MIB