All MIBs › OMNI-gx2RSW1000B-MIB › rsw1000bvaluePriStatusSig
rsw1000bvaluePriStatusSig
Module: OMNI-gx2RSW1000B-MIB
OID (symbolic): OMNI-gx2RSW1000B-MIB::rsw1000bvaluePriStatusSig
OID (numeric): 1.3.6.1.4.1.1166.6.1.2.18.3.2.28
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The value of this object is the current value of the parameter.
What is rsw1000bvaluePriStatusSig?
Reports the current state of the primary control-signal line: short(1), valid(2), invalid(3), or open(4) — useful for diagnosing a wiring fault (short or open) versus a normal valid signal.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.18.3.2.28 snmpwalk -v2c -c public <target> OMNI-gx2RSW1000B-MIB::rsw1000bvaluePriStatusSig
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.18.3.2.28.1 snmpget -v2c -c public <target> OMNI-gx2RSW1000B-MIB::rsw1000bvaluePriStatusSig.1
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 RSW1000B 1000 MHz RF switch module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2RSW1000B-MIB::rsw1000bvaluePriStatusSig OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 RSW1000B 1000 MHz RF switch module) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.18 | gx2Rsw1000b | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.18.3 | gx2Rsw1000bDigitalTable | OMNI-gx2RSW1000B-MIB |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2 | gx2Rsw1000bDigitalEntry | OMNI-gx2RSW1000B-MIB |
| 1.3.6.1.4.1.1166.6.1.2.18.3.2.28 | rsw1000bvaluePriStatusSig | OMNI-gx2RSW1000B-MIB |