OMNI-gx2RSW1000B-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gx2Rsw1000b FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "4" Jan 20, 2003 --DESCRIPTION -- Added revision and description comment section --REVISION "5" Dec 18, 2003 --DESCRIPTION -- Fixed discrepancies from Rev "4" -- Renamed parameters to properly reflect thier function -- This version will be used to do pre-release firmware -- testing of RSW1000B -- Changes will be marked "DFL: description of change..." --REVISION "6" Jan 14, 2004 --DESCRIPTION -- (Changes based on MIB Review directives) -- * Remove: "IpAddress, TimeTicks FROM RFC1155-SMI", -- "sysUpTime", -- "gi,motproxies FROM NLS-BBNIDENT-MIB" -- * Change integer upper limit to 2^31-1 (2147483647) -- * For the unused analog limits add the following text: -- "This object is not used by this module and always -- returns invalid float value of 0xFFFFFFFF . This -- object is kept here for persistence." -- * Unused analog object defined as "obsolete" rather than -- "mandatory" -- * Removed unnecessary comments: -- "Contains a list...network elements" -- "!!! THE TRAP SECTION..." -- "DFL: description of change..." -- * Enforce correspondance with enumeration values ant text -- comments -- * Specified unit of measure in comments: -- "For all analog objects for this parameter type, the -- unit of measure is ___." -- * Remove IEEE floating point comments (consolidate in one -- general comment) -- * Uptate text to identify "gauge" limit parameters. -- * Annotate rsw1000bvalueFactoryDefault with behavioral -- description. --REVISION "7" March 02, 2004 --DESCRIPTION -- Made the PRI/SEC level alarms "unused" -- All analog alarm state parameters are mandatory -- OMNISTAR RF Switch Module MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2Rsw1000b Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Rsw1000b device type. -- These parameters are common across all network elements -- from gx2Rsw1000b device type. -- -- The gx2Rsw1000b Network Elements subgroup is -- a list of gx2Rsw1000b type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Rsw1000b TableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Lmc type. -- -- Both groups are mandatory for management of gx2Lmc devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2Rsw1000b Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Rsw1000b device type. -- These parameters are common across all network elements -- from gx2Rsw1000b device type. gx2Rsw1000bDescriptor OBJECT IDENTIFIER ::= {gx2Rsw1000b 1} --***************************************************************************** -- gx2Rsw1000b Table -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Rsw1000bTableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2Rsw1000b type. gx2Rsw1000bAnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rsw1000bAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rsw1000b specific parameters with nominal and current values." ::= { gx2Rsw1000b 2 } gx2Rsw1000bAnalogEntry OBJECT-TYPE SYNTAX Gx2Rsw1000bAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2Rsw1000bAnalogTableIndex } ::= { gx2Rsw1000bAnalogTable 1} --***************************************************************************** gx2Rsw1000bDigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rsw1000bDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rsw1000b specific parameters with nominal and current values." ::= { gx2Rsw1000b 3 } gx2Rsw1000bDigitalEntry OBJECT-TYPE SYNTAX Gx2Rsw1000bDigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital parameters and descriptions." INDEX { gx2Rsw1000bDigitalTableIndex } ::= { gx2Rsw1000bDigitalTable 2} --***************************************************************************** gx2Rsw1000bStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rsw1000bStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rsw1000b specific parameters with nominal and current values." ::= { gx2Rsw1000b 4 } gx2Rsw1000bStatusEntry OBJECT-TYPE SYNTAX Gx2Rsw1000bStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2Rsw1000bStatusTableIndex } ::= { gx2Rsw1000bStatusTable 3} --***************************************************************************** gx2Rsw1000bFactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rsw1000bFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rsw1000b specific parameters with nominal and current values." ::= { gx2Rsw1000b 5 } gx2Rsw1000bFactoryEntry OBJECT-TYPE SYNTAX Gx2Rsw1000bFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory parameters and descriptions." INDEX { gx2Rsw1000bFactoryTableIndex } ::= { gx2Rsw1000bFactoryTable 4} --***************************************************************************** gx2Rsw1000bHoldTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Rsw1000bHoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Rsw1000b specific parameters with nominal and current values." ::= { gx2Rsw1000b 6 } gx2Rsw1000bHoldTimeEntry OBJECT-TYPE SYNTAX Gx2Rsw1000bHoldTimeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital product class and the associated RF channel parameters and descriptions." INDEX { rxgx2Rsw1000bHoldTimeTableIndex, rxgx2Rsw1000bHoldTimeSpecIndex } ::= { gx2Rsw1000bHoldTimeTable 5} --*********************************************************************** Gx2Rsw1000bAnalogEntry ::= SEQUENCE { gx2Rsw1000bAnalogTableIndex INTEGER, -- Analog Parameters rsw1000blabelPriRFInputLvl DisplayString (SIZE (0..80)), rsw1000buomPriRFInputLvl DisplayString (SIZE (0..80)), rsw1000bmajorHighPriRFInputLvl Float, rsw1000bmajorLowPriRFInputLvl Float, rsw1000bminorHighPriRFInputLvl Float, rsw1000bminorLowPriRFInputLvl Float, rsw1000bcurrentValuePriRFInputLvl Float, rsw1000bstateFlagPriRFInputLvl INTEGER, rsw1000bminValuePriRFInputLvl Float, rsw1000bmaxValuePriRFInputLvl Float, rsw1000balarmStatePriRFInputLvl INTEGER, rsw1000blabelSecRFInputLvl DisplayString (SIZE (0..80)), rsw1000buomSecRFInputLvl DisplayString (SIZE (0..80)), rsw1000bmajorHighSecRFInputLvl Float, rsw1000bmajorLowSecRFInputLvl Float, rsw1000bminorHighSecRFInputLvl Float, rsw1000bminorLowSecRFInputLvl Float, rsw1000bcurrentValueSecRFInputLvl Float, rsw1000bstateFlagSecRFInputLvl INTEGER, rsw1000bminValueSecRFInputLvl Float, rsw1000bmaxValueSecRFInputLvl Float, rsw1000balarmStateSecRFInputLvl INTEGER, rsw1000blabelPriRFThreshold DisplayString (SIZE (0..80)), rsw1000buomPriRFThreshold DisplayString (SIZE (0..80)), rsw1000bmajorHighPriRFThreshold Float, rsw1000bmajorLowPriRFThreshold Float, rsw1000bminorHighPriRFThreshold Float, rsw1000bminorLowPriRFThreshold Float, rsw1000bcurrentValuePriRFThreshold Float, rsw1000bstateFlagPriRFThreshold INTEGER, rsw1000bminValuePriRFThreshold Float, rsw1000bmaxValuePriRFThreshold Float, rsw1000balarmStatePriRFThreshold INTEGER, rsw1000blabelSecRFThreshold DisplayString (SIZE (0..80)), rsw1000buomSecRFThreshold DisplayString (SIZE (0..80)), rsw1000bmajorHighSecRFThreshold Float, rsw1000bmajorLowSecRFThreshold Float, rsw1000bminorHighSecRFThreshold Float, rsw1000bminorLowSecRFThreshold Float, rsw1000bcurrentValueSecRFThreshold Float, rsw1000bstateFlagSecRFThreshold INTEGER, rsw1000bminValueSecRFThreshold Float, rsw1000bmaxValueSecRFThreshold Float, rsw1000balarmStateSecRFThreshold INTEGER, rsw1000blabelModTemp DisplayString (SIZE (0..80)), rsw1000buomModTemp DisplayString (SIZE (0..80)), rsw1000bmajorHighModTemp Float, rsw1000bmajorLowModTemp Float, rsw1000bminorHighModTemp Float, rsw1000bminorLowModTemp Float, rsw1000bcurrentValueModTemp Float, rsw1000bstateFlagModTemp INTEGER, rsw1000bminValueModTemp Float, rsw1000bmaxValueModTemp Float, rsw1000balarmStateModTemp INTEGER, rsw1000blabelFanCurrent DisplayString (SIZE (0..80)), rsw1000buomFanCurrent DisplayString (SIZE (0..80)), rsw1000bmajorHighFanCurrent Float, rsw1000bmajorLowFanCurrent Float, rsw1000bminorHighFanCurrent Float, rsw1000bminorLowFanCurrent Float, rsw1000bcurrentValueFanCurrent Float, rsw1000bstateFlagFanCurrent INTEGER, rsw1000bminValueFanCurrent Float, rsw1000bmaxValueFanCurrent Float, rsw1000balarmStateFanCurrent INTEGER } -- **************** Digital Parameters *********************** Gx2Rsw1000bDigitalEntry ::= SEQUENCE { gx2Rsw1000bDigitalTableIndex INTEGER, rsw1000blabelSwitchControl DisplayString (SIZE (0..80)), rsw1000benumSwitchControl DisplayString (SIZE (0..80)), rsw1000bvalueSwitchControl INTEGER, rsw1000bstateflagSwitchControl INTEGER, rsw1000blabelSwitchMode DisplayString (SIZE (0..80)), rsw1000benumSwitchMode DisplayString (SIZE (0..80)), rsw1000bvalueSwitchMode INTEGER, rsw1000bstateflagSwitchMode INTEGER, rsw1000blabelRevertEnable DisplayString (SIZE (0..80)), rsw1000benumRevertEnable DisplayString (SIZE (0..80)), rsw1000bvalueRevertEnable INTEGER, rsw1000bstateflagRevertEnable INTEGER, rsw1000blabelRevertTime DisplayString (SIZE (0..80)), rsw1000benumRevertTime DisplayString (SIZE (0..80)), rsw1000bvalueRevertTime INTEGER, rsw1000bstateflagRevertTime INTEGER, rsw1000blabelSensorMode DisplayString (SIZE (0..80)), rsw1000benumSensorMode DisplayString (SIZE (0..80)), rsw1000bvalueSensorMode INTEGER, rsw1000bstateflagSensorMode INTEGER, rsw1000blabelSwitchMonitor DisplayString (SIZE (0..80)), rsw1000benumSwitchMonitor DisplayString (SIZE (0..80)), rsw1000bvalueSwitchMonitor INTEGER, rsw1000bstateflagSwitchMonitor INTEGER, rsw1000blabelPriStatusSig DisplayString (SIZE (0..80)), rsw1000benumPriStatusSig DisplayString (SIZE (0..80)), rsw1000bvaluePriStatusSig INTEGER, rsw1000bstateflagPriStatusSig INTEGER, rsw1000blabelSecStatusSig DisplayString (SIZE (0..80)), rsw1000benumSecStatusSig DisplayString (SIZE (0..80)), rsw1000bvalueSecStatusSig INTEGER, rsw1000bstateflagSecStatusSig INTEGER, rsw1000blabelFactoryDefault DisplayString (SIZE (0..80)), rsw1000benumFactoryDefault DisplayString (SIZE (0..80)), rsw1000bvalueFactoryDefault INTEGER, rsw1000bstateflagFactoryDefault INTEGER } -- **************** Status Parameters ************************************ Gx2Rsw1000bStatusEntry ::= SEQUENCE { gx2Rsw1000bStatusTableIndex INTEGER, rsw1000blabelBoot DisplayString (SIZE (0..80)), rsw1000bvalueBoot INTEGER, rsw1000bstateflagBoot INTEGER, rsw1000blabelFlash DisplayString (SIZE (0..80)), rsw1000bvalueFlash INTEGER, rsw1000bstateflagFlash INTEGER, rsw1000blabelFactoryDataCRC DisplayString (SIZE (0..80)), rsw1000bvalueFactoryDataCRC INTEGER, rsw1000bstateflagFactoryDataCRC INTEGER, rsw1000blabelRFDataCRC DisplayString (SIZE (0..80)), rsw1000bvalueRFDataCRC INTEGER, rsw1000bstateflagRFDataCRC INTEGER, rsw1000blabelAlarmDataCRC DisplayString (SIZE (0..80)), rsw1000bvalueAlarmDataCRC INTEGER, rsw1000bstateflagAlarmDataCRC INTEGER, rsw1000blabelRFSignalStatus DisplayString (SIZE (0..80)), rsw1000bvalueRFSignalStatus INTEGER, rsw1000bstateflagRFSignalStatus INTEGER, rsw1000blabelPriActiveStatus DisplayString (SIZE (0..80)), rsw1000bvaluePriActiveStatus INTEGER, rsw1000bstateflagPriActiveStatus INTEGER } -- **************** Factory Parameters ************************************* Gx2Rsw1000bFactoryEntry ::= SEQUENCE { gx2Rsw1000bFactoryTableIndex INTEGER, rsw1000bbootControlByte INTEGER, rsw1000bbootStatusByte INTEGER, rsw1000bbank0CRC INTEGER, rsw1000bbank1CRC INTEGER, rsw1000bprgEEPROMByte INTEGER, rsw1000bfactoryCRC INTEGER, rsw1000bcalculateCRC INTEGER, rsw1000bhourMeter INTEGER, rsw1000bflashPrgCnt0 INTEGER, rsw1000bflashPrgCnt1 INTEGER, rsw1000bflashBank0Rev DisplayString (SIZE (0..80)), rsw1000bflashBank1Rev DisplayString (SIZE (0..80)), rsw1000bSubagentRev DisplayString (SIZE (0..80)) } -- **************** Hold Time Parameters ************************************* Gx2Rsw1000bHoldTimeEntry ::= SEQUENCE { rxgx2Rsw1000bHoldTimeTableIndex INTEGER, rxgx2Rsw1000bHoldTimeSpecIndex INTEGER, rxgx2Rsw1000bHoldTimeData INTEGER } -- ************** Analog Parameters **************************** gx2Rsw1000bAnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rsw1000bAnalogEntry 1} rsw1000blabelPriRFInputLvl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Primary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 2} rsw1000buomPriRFInputLvl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Primary RF Input Level Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV." ::= { gx2Rsw1000bAnalogEntry 3} rsw1000bmajorHighPriRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Primary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 4} rsw1000bmajorLowPriRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Primary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 5} rsw1000bminorHighPriRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Primary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 6} rsw1000bminorLowPriRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Primary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 7} rsw1000bcurrentValuePriRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Primary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 8} rsw1000bstateFlagPriRFInputLvl OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Primary RF Input Level Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2Rsw1000bAnalogEntry 9} rsw1000bminValuePriRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge minimum limit for the Primary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 10} rsw1000bmaxValuePriRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge maximum limit for the Primary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 11} rsw1000balarmStatePriRFInputLvl OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Primary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 12} rsw1000blabelSecRFInputLvl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Secondary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 13} rsw1000buomSecRFInputLvl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Secondary RF Input Level Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV." ::= { gx2Rsw1000bAnalogEntry 14} rsw1000bmajorHighSecRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Secondary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 15} rsw1000bmajorLowSecRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Secondary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 16} rsw1000bminorHighSecRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Secondary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 17} rsw1000bminorLowSecRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Secondary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 18} rsw1000bcurrentValueSecRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Secondary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 19} rsw1000bstateFlagSecRFInputLvl OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Secondary RF Input Level Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2Rsw1000bAnalogEntry 20} rsw1000bminValueSecRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge minimum limit for the Secondary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 21} rsw1000bmaxValueSecRFInputLvl OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge maximum limit for the Secondary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 22} rsw1000balarmStateSecRFInputLvl OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Secondary RF Input Level Analog parameter." ::= { gx2Rsw1000bAnalogEntry 23} rsw1000blabelPriRFThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Primary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 24} rsw1000buomPriRFThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Primary RF Threshold Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV." ::= { gx2Rsw1000bAnalogEntry 25} rsw1000bmajorHighPriRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Primary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 26} rsw1000bmajorLowPriRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Primary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 27} rsw1000bminorHighPriRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Primary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 28} rsw1000bminorLowPriRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Primary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 29} rsw1000bcurrentValuePriRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Primary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 30} rsw1000bstateFlagPriRFThreshold OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Primary RF Threshold Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2Rsw1000bAnalogEntry 31} rsw1000bminValuePriRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge minimum limit for the Primary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 32} rsw1000bmaxValuePriRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge maximum limit for the Primary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 33} rsw1000balarmStatePriRFThreshold OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Primary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 34} rsw1000blabelSecRFThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Secondary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 35} rsw1000buomSecRFThreshold OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Secondary RF Threshold Analog parameter. For all analog objects for this parameter type, the Unit of Measure is dBmV." ::= { gx2Rsw1000bAnalogEntry 36} rsw1000bmajorHighSecRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major High alarm value of the Secondary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 37} rsw1000bmajorLowSecRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Major Low alarm value of the Secondary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 38} rsw1000bminorHighSecRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Secondary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 39} rsw1000bminorLowSecRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Secondary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 40} rsw1000bcurrentValueSecRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the current value of the Secondary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 41} rsw1000bstateFlagSecRFThreshold OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Secondary RF Threshold Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2Rsw1000bAnalogEntry 42} rsw1000bminValueSecRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge minimum limit for the Secondary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 43} rsw1000bmaxValueSecRFThreshold OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge maximum limit for the Secondary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 44} rsw1000balarmStateSecRFThreshold OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Secondary RF Threshold Analog parameter." ::= { gx2Rsw1000bAnalogEntry 45} rsw1000blabelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2Rsw1000bAnalogEntry 46} rsw1000buomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. For all analog objects for this parameter type, the Unit of Measure is degrees Celsius." ::= { gx2Rsw1000bAnalogEntry 47} rsw1000bmajorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter." ::= { gx2Rsw1000bAnalogEntry 48} rsw1000bmajorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter." ::= { gx2Rsw1000bAnalogEntry 49} rsw1000bminorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter." ::= { gx2Rsw1000bAnalogEntry 50} rsw1000bminorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter." ::= { gx2Rsw1000bAnalogEntry 51} rsw1000bcurrentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter." ::= { gx2Rsw1000bAnalogEntry 52} rsw1000bstateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2Rsw1000bAnalogEntry 53} rsw1000bminValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge minimum limit for the Module Temperature Analog parameter." ::= { gx2Rsw1000bAnalogEntry 54} rsw1000bmaxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge maximum limit for the Module Temperature Analog parameter." ::= { gx2Rsw1000bAnalogEntry 55} rsw1000balarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2Rsw1000bAnalogEntry 56} rsw1000blabelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2Rsw1000bAnalogEntry 57} rsw1000buomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter. For all analog objects for this parameter type, the Unit of Measure is mA" ::= { gx2Rsw1000bAnalogEntry 58} rsw1000bmajorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter." ::= { gx2Rsw1000bAnalogEntry 59} rsw1000bmajorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter." ::= { gx2Rsw1000bAnalogEntry 60} rsw1000bminorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid floating point value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor High alarm value of the Fan Current Analog parameter." ::= { gx2Rsw1000bAnalogEntry 61} rsw1000bminorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "This object is not used by this module and always returns invalid floating point value of 0xFFFFFFFF. This object is kept here for persistence. The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter." ::= { gx2Rsw1000bAnalogEntry 62} rsw1000bcurrentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter." ::= { gx2Rsw1000bAnalogEntry 63} rsw1000bstateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2Rsw1000bAnalogEntry 64} rsw1000bminValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge minimum limit for the Fan Current Analog parameter." ::= { gx2Rsw1000bAnalogEntry 65} rsw1000bmaxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents a gauge maximum limit for the Fan Current Analog parameter." ::= { gx2Rsw1000bAnalogEntry 66} rsw1000balarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2Rsw1000bAnalogEntry 67} -- ************************ Digital parameters ********************************** gx2Rsw1000bDigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rsw1000bDigitalEntry 1} rsw1000blabelSwitchControl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Switch Control Digital parameter." ::= { gx2Rsw1000bDigitalEntry 2} rsw1000benumSwitchControl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rsw1000bDigitalEntry 3} rsw1000bvalueSwitchControl OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rsw1000bDigitalEntry 4} rsw1000bstateflagSwitchControl OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bDigitalEntry 5} rsw1000blabelSwitchMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Revert Mode Digital parameter." ::= { gx2Rsw1000bDigitalEntry 6} rsw1000benumSwitchMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rsw1000bDigitalEntry 7} rsw1000bvalueSwitchMode OBJECT-TYPE SYNTAX INTEGER { automatic(1), manual(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rsw1000bDigitalEntry 8} rsw1000bstateflagSwitchMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bDigitalEntry 9} rsw1000blabelRevertEnable OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Revert Enable Digital parameter." ::= { gx2Rsw1000bDigitalEntry 10} rsw1000benumRevertEnable OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rsw1000bDigitalEntry 11} rsw1000bvalueRevertEnable OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rsw1000bDigitalEntry 12} rsw1000bstateflagRevertEnable OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2Rsw1000bDigitalEntry 13} rsw1000blabelRevertTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Revert Time Digital parameter." ::= { gx2Rsw1000bDigitalEntry 14} rsw1000benumRevertTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rsw1000bDigitalEntry 15} rsw1000bvalueRevertTime OBJECT-TYPE SYNTAX INTEGER { tensec(1), sixtysec(2), sixhundredsec(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rsw1000bDigitalEntry 16} rsw1000bstateflagRevertTime OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable)." ::= { gx2Rsw1000bDigitalEntry 17} rsw1000blabelSensorMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the SensorMode Digital parameter." ::= { gx2Rsw1000bDigitalEntry 18} rsw1000benumSensorMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rsw1000bDigitalEntry 19} rsw1000bvalueSensorMode OBJECT-TYPE SYNTAX INTEGER { internal(1), external(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rsw1000bDigitalEntry 20} rsw1000bstateflagSensorMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bDigitalEntry 21} rsw1000blabelSwitchMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Switch Monitor Digital parameter." ::= { gx2Rsw1000bDigitalEntry 22} rsw1000benumSwitchMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rsw1000bDigitalEntry 23} rsw1000bvalueSwitchMonitor OBJECT-TYPE SYNTAX INTEGER { primary(1), secondary(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rsw1000bDigitalEntry 24} rsw1000bstateflagSwitchMonitor OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bDigitalEntry 25} rsw1000blabelPriStatusSig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Primary Control Signal Digital parameter." ::= { gx2Rsw1000bDigitalEntry 26} rsw1000benumPriStatusSig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rsw1000bDigitalEntry 27} rsw1000bvaluePriStatusSig OBJECT-TYPE SYNTAX INTEGER { short(1), valid(2), invalid(3), open(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rsw1000bDigitalEntry 28} rsw1000bstateflagPriStatusSig OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bDigitalEntry 29} rsw1000blabelSecStatusSig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Secondary Control Signal Digital parameter." ::= { gx2Rsw1000bDigitalEntry 30} rsw1000benumSecStatusSig OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rsw1000bDigitalEntry 31} rsw1000bvalueSecStatusSig OBJECT-TYPE SYNTAX INTEGER { short(1), valid(2), invalid(3), open(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Rsw1000bDigitalEntry 32} rsw1000bstateflagSecStatusSig OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bDigitalEntry 33} rsw1000blabelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Reset Digital parameter." ::= { gx2Rsw1000bDigitalEntry 34} rsw1000benumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Rsw1000bDigitalEntry 35} rsw1000bvalueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This is a one-shot control value. A read of this value is always the value corresponding to off(1). A write of the value corresponding to on(2) results in effecting the factory default reset. A write of the value corresponding to off(1) has no effect." ::= { gx2Rsw1000bDigitalEntry 36} rsw1000bstateflagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bDigitalEntry 37} --*********** STATUS ***************** gx2Rsw1000bStatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rsw1000bStatusEntry 1} rsw1000blabelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2Rsw1000bStatusEntry 2} rsw1000bvalueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical)." ::= { gx2Rsw1000bStatusEntry 3} rsw1000bstateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bStatusEntry 4} rsw1000blabelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2Rsw1000bStatusEntry 5} rsw1000bvalueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical)." ::= { gx2Rsw1000bStatusEntry 6} rsw1000bstateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bStatusEntry 7} rsw1000blabelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2Rsw1000bStatusEntry 8} rsw1000bvalueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical)." ::= { gx2Rsw1000bStatusEntry 9} rsw1000bstateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bStatusEntry 10} rsw1000blabelRFDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Radio Frequency Data CRC Status parameter." ::= { gx2Rsw1000bStatusEntry 11} rsw1000bvalueRFDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical)." ::= { gx2Rsw1000bStatusEntry 12} rsw1000bstateflagRFDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bStatusEntry 13} rsw1000blabelAlarmDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2Rsw1000bStatusEntry 14} rsw1000bvalueAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical)." ::= { gx2Rsw1000bStatusEntry 15} rsw1000bstateflagAlarmDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bStatusEntry 16} rsw1000blabelRFSignalStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Signal Status parameter." ::= { gx2Rsw1000bStatusEntry 17} rsw1000bvalueRFSignalStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical)." ::= { gx2Rsw1000bStatusEntry 18} rsw1000bstateflagRFSignalStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bStatusEntry 19} rsw1000blabelPriActiveStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Secondary Active Status parameter." ::= { gx2Rsw1000bStatusEntry 20} rsw1000bvaluePriActiveStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical)." ::= { gx2Rsw1000bStatusEntry 21} rsw1000bstateflagPriActiveStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable)." ::= { gx2Rsw1000bStatusEntry 22} -- ************ FACTORY DATA **************** gx2Rsw1000bFactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Rsw1000bFactoryEntry 1} rsw1000bbootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2Rsw1000bFactoryEntry 2} rsw1000bbootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot" ::= { gx2Rsw1000bFactoryEntry 3} rsw1000bbank0CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0." ::= { gx2Rsw1000bFactoryEntry 4} rsw1000bbank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1." ::= { gx2Rsw1000bFactoryEntry 5} rsw1000bprgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2Rsw1000bFactoryEntry 6} rsw1000bfactoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2Rsw1000bFactoryEntry 7} rsw1000bcalculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), rf(2), alarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This oject indicates which of the Emnums will have the CRC calculated." ::= { gx2Rsw1000bFactoryEntry 8} rsw1000bhourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2Rsw1000bFactoryEntry 9} rsw1000bflashPrgCnt0 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2Rsw1000bFactoryEntry 10} rsw1000bflashPrgCnt1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2Rsw1000bFactoryEntry 11} rsw1000bflashBank0Rev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0." ::= { gx2Rsw1000bFactoryEntry 12} rsw1000bflashBank1Rev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1." ::= { gx2Rsw1000bFactoryEntry 13} rsw1000bSubagentRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of the subagent." ::= { gx2Rsw1000bFactoryEntry 14} -- ************ Hold Time DATA **************** rxgx2Rsw1000bHoldTimeTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is the index of the data object." ::= { gx2Rsw1000bHoldTimeEntry 1} rxgx2Rsw1000bHoldTimeSpecIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the index of the alarm object to be modified." ::= { gx2Rsw1000bHoldTimeEntry 2} rxgx2Rsw1000bHoldTimeData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds." ::= { gx2Rsw1000bHoldTimeEntry 3} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ************************************************************************** -- RF Switch Module traps -- ************************************************************************** trapRSW1000bConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapRSW1000bConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapRSW1000bRFInputAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Switch Control signals go out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapRSW1000bFanCurrentAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapRSW1000bModuleTempAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 5 trapRSW1000bFlashAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the detects an error during Flash memory operations." ::= 6 trapRSW1000bBankBootAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the detects an error while booting from bank 0 or bank 1." ::= 7 trapRSW1000bAlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 8 trapRSW1000bFactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 9 trapRSW1000bInputSwitchedAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the RF input switched." ::= 10 trapRSW1000bResetFactoryDefaultAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Default Reset occurs." ::= 11 trapRSW1000bSecondaryInputActiveAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the scondary input becomes active." ::= 12 trapRSW1000bCalibrationDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Rsw1000b VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the calibration data CRC is incorrect." ::= 13 END -- // Section: Header & History