All MIBs › OMNI-gx2Em870-MIB › gx2Em870HoldTimeData
gx2Em870HoldTimeData
Module: OMNI-gx2Em870-MIB
OID (symbolic): OMNI-gx2Em870-MIB::gx2Em870HoldTimeData
OID (numeric): 1.3.6.1.4.1.1166.6.1.2.12.6.5.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
What is gx2Em870HoldTimeData?
Read-write 32-bit value that sets the alarm hold-off (debounce) timer, from 0 to 1300 seconds, for the analog alarm identified by this row's index, so an admin can suppress brief noise-driven alarm flaps on the EM870 without disabling the alarm itself; the object packs separate validation and timer-duration bytes within the same 32-bit value.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.12.6.5.3 snmpwalk -v2c -c public <target> OMNI-gx2Em870-MIB::gx2Em870HoldTimeData
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.12.6.5.3.1 snmpget -v2c -c public <target> OMNI-gx2Em870-MIB::gx2Em870HoldTimeData.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.12.6.5.3.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> gx2Em870HoldTimeData.1
Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM870 870 MHz expansion module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2Em870-MIB::gx2Em870HoldTimeData OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 EM870 870 MHz expansion module) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.12 | gx2Em870 | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.12.6 | gx2Em870HoldTimeTable | OMNI-gx2Em870-MIB |
| 1.3.6.1.4.1.1166.6.1.2.12.6.5 | gx2Em870HoldTimeEntry | OMNI-gx2Em870-MIB |
| 1.3.6.1.4.1.1166.6.1.2.12.6.5.3 | gx2Em870HoldTimeData | OMNI-gx2Em870-MIB |