OMNI-gx2CEB-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress, TimeTicks, Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2CEB FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "0" Sept 1, 2003 --DESCRIPTION -- Added revision and description comment section -- OMNISTAR DM 1550 Laser Module (Return Path Transmetter) MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2CEB Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2CEB device type. -- These parameters are common across all network elements -- from gx2CEB device type. -- -- The gx2CEB Network Elements subgroup is -- a list of gx2CEB type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2CEBTableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2CEB type. -- -- Both groups are mandatory for management of gx2CEB devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2CEB Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2CEB device type. -- These parameters are common across all network elements -- from gx2CEB device type. gx2CEBDescriptor OBJECT IDENTIFIER ::= {gx2CEB 1} --***************************************************************************** -- gx2CEB Table -- Contains a list of all gx2CEB type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2CEBTableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2CEB type. gx2CEBAnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2CEBAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2CEB specific parameters with nominal and current values." ::= { gx2CEB 2 } gx2CEBAnalogEntry OBJECT-TYPE SYNTAX Gx2CEBAnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2CEBAnalogTableIndex } ::= { gx2CEBAnalogTable 1} --************************************************************************* --************ No Digital Table ******************************************* --************************************************************************* gx2CEBStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2CEBStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2CEB specific parameters with nominal and current values." ::= { gx2CEB 3 } gx2CEBStatusEntry OBJECT-TYPE SYNTAX Gx2CEBStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2CEBStatusTableIndex } ::= { gx2CEBStatusTable 2} --************************************************************************* gx2CEBFactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2CEBFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2CEB specific parameters with nominal and current values." ::= { gx2CEB 4 } gx2CEBFactoryEntry OBJECT-TYPE SYNTAX Gx2CEBFactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory parameters and descriptions." INDEX { gx2CEBFactoryTableIndex } ::= { gx2CEBFactoryTable 3} --************************************************************************* Gx2CEBAnalogEntry ::= SEQUENCE { gx2CEBAnalogTableIndex INTEGER, -- Analog Parameters ceblabelModTemp DisplayString (SIZE (0..80)), cebuomModTemp DisplayString (SIZE (0..80)), cebmajorHighModTemp Float, cebmajorLowModTemp Float, cebminorHighModTemp Float, cebminorLowModTemp Float, cebcurrentValueModTemp Float, cebstateFlagModTemp INTEGER, cebminValueModTemp Float, cebmaxValueModTemp Float, cebalarmStateModTemp INTEGER, ceblabelFanCurrent DisplayString (SIZE (0..80)), cebuomFanCurrent DisplayString (SIZE (0..80)), cebmajorHighFanCurrent Float, cebmajorLowFanCurrent Float, cebminorHighFanCurrent Float, cebminorLowFanCurrent Float, cebcurrentValueFanCurrent Float, cebstateFlagFanCurrent INTEGER, cebminValueFanCurrent Float, cebmaxValueFanCurrent Float, cebalarmStateFanCurrent INTEGER, ceblabelAnalogVoltage01 DisplayString (SIZE (0..80)), cebuomAnalogVoltage01 DisplayString (SIZE (0..80)), cebmajorHighAnalogVoltage01 Float, cebmajorLowAnalogVoltage01 Float, cebminorHighAnalogVoltage01 Float, cebminorLowAnalogVoltage01 Float, cebcurrentValueAnalogVoltage01 Float, cebstateFlagAnalogVoltage01 INTEGER, cebminValueAnalogVoltage01 Float, cebmaxValueAnalogVoltage01 Float, cebalarmStateAnalogVoltage01 INTEGER, ceblabelAnalogVoltage02 DisplayString (SIZE (0..80)), cebuomAnalogVoltage02 DisplayString (SIZE (0..80)), cebmajorHighAnalogVoltage02 Float, cebmajorLowAnalogVoltage02 Float, cebminorHighAnalogVoltage02 Float, cebminorLowAnalogVoltage02 Float, cebcurrentValueAnalogVoltage02 Float, cebstateFlagAnalogVoltage02 INTEGER, cebminValueAnalogVoltage02 Float, cebmaxValueAnalogVoltage02 Float, cebalarmStateAnalogVoltage02 INTEGER, ceblabelAnalogVoltage03 DisplayString (SIZE (0..80)), cebuomAnalogVoltage03 DisplayString (SIZE (0..80)), cebmajorHighAnalogVoltage03 Float, cebmajorLowAnalogVoltage03 Float, cebminorHighAnalogVoltage03 Float, cebminorLowAnalogVoltage03 Float, cebcurrentValueAnalogVoltage03 Float, cebstateFlagAnalogVoltage03 INTEGER, cebminValueAnalogVoltage03 Float, cebmaxValueAnalogVoltage03 Float, cebalarmStateAnalogVoltage03 INTEGER, ceblabelAnalogVoltage04 DisplayString (SIZE (0..80)), cebuomAnalogVoltage04 DisplayString (SIZE (0..80)), cebmajorHighAnalogVoltage04 Float, cebmajorLowAnalogVoltage04 Float, cebminorHighAnalogVoltage04 Float, cebminorLowAnalogVoltage04 Float, cebcurrentValueAnalogVoltage04 Float, cebstateFlagAnalogVoltage04 INTEGER, cebminValueAnalogVoltage04 Float, cebmaxValueAnalogVoltage04 Float, cebalarmStateAnalogVoltage04 INTEGER, ceblabelAnalogVoltage05 DisplayString (SIZE (0..80)), cebuomAnalogVoltage05 DisplayString (SIZE (0..80)), cebmajorHighAnalogVoltage05 Float, cebmajorLowAnalogVoltage05 Float, cebminorHighAnalogVoltage05 Float, cebminorLowAnalogVoltage05 Float, cebcurrentValueAnalogVoltage05 Float, cebstateFlagAnalogVoltage05 INTEGER, cebminValueAnalogVoltage05 Float, cebmaxValueAnalogVoltage05 Float, cebalarmStateAnalogVoltage05 INTEGER } -- **************** Digital Parameters *********************** -- **************** Status Parameters ************************************ Gx2CEBStatusEntry ::= SEQUENCE { gx2CEBStatusTableIndex INTEGER, ceblabelBoot DisplayString (SIZE (0..80)), cebvalueBoot INTEGER, cebstateflagBoot INTEGER, ceblabelFlash DisplayString (SIZE (0..80)), cebvalueFlash INTEGER, cebstateflagFlash INTEGER, ceblabelFactoryDataCRC DisplayString (SIZE (0..80)), cebvalueFactoryDataCRC INTEGER, cebstateflagFactoryDataCRC INTEGER, ceblabelAlarmDataCrc DisplayString (SIZE (0..80)), cebvalueAlarmDataCrc INTEGER, cebstateflagAlarmDataCrc INTEGER } -- **************** Factory Parameters ************************************* Gx2CEBFactoryEntry ::= SEQUENCE { gx2CEBFactoryTableIndex INTEGER, cebbootControlByte INTEGER, cebbootStatusByte INTEGER, cebbank1CRC INTEGER, cebbank2CRC INTEGER, cebprgEEPROMByte INTEGER, cebfactoryCRC INTEGER, cebcalculateCRC INTEGER, cebhourMeter INTEGER, cebflashPrgCntA INTEGER, cebflashPrgCntB INTEGER, cebflashBankARev DisplayString (SIZE (0..80)), cebflashBankBRev DisplayString (SIZE (0..80)) } -- ************** Analog Parameters **************************** gx2CEBAnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2CEBAnalogEntry 1} -- New Parameter ceblabelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2CEBAnalogEntry 2} cebuomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2CEBAnalogEntry 3} cebmajorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 4} cebmajorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 5} cebminorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 6} cebminorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 7} cebcurrentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 8} cebstateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBAnalogEntry 9} cebminValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 10} cebmaxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 11} cebalarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2CEBAnalogEntry 12} -- New Parameter ceblabelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2CEBAnalogEntry 13} cebuomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2CEBAnalogEntry 14} cebmajorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 15} cebmajorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 16} cebminorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 17} cebminorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 18} cebcurrentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 19} cebstateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBAnalogEntry 20} cebminValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 21} cebmaxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 22} cebalarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2CEBAnalogEntry 23 } -- New Parameter ceblabelAnalogVoltage01 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Analog Voltage number 01 Analog parameter." ::= { gx2CEBAnalogEntry 24} cebuomAnalogVoltage01 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Analog Voltage number 01 Analog parameter." ::= { gx2CEBAnalogEntry 25} cebmajorHighAnalogVoltage01 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 26} cebmajorLowAnalogVoltage01 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 27} cebminorHighAnalogVoltage01 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 28} cebminorLowAnalogVoltage01 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 29} cebcurrentValueAnalogVoltage01 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value Analog Voltage number 01 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 30} cebstateFlagAnalogVoltage01 OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Analog Voltage number 01 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBAnalogEntry 31} cebminValueAnalogVoltage01 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 32} cebmaxValueAnalogVoltage01 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Analog Voltage number 01 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 33} cebalarmStateAnalogVoltage01 OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter." ::= { gx2CEBAnalogEntry 34} -- New Parameter ceblabelAnalogVoltage02 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Analog Voltage number 02 Analog parameter." ::= { gx2CEBAnalogEntry 35} cebuomAnalogVoltage02 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Analog Voltage number 02 Analog parameter." ::= { gx2CEBAnalogEntry 36} cebmajorHighAnalogVoltage02 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 37} cebmajorLowAnalogVoltage02 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 38} cebminorHighAnalogVoltage02 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 39} cebminorLowAnalogVoltage02 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 40} cebcurrentValueAnalogVoltage02 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value Analog Voltage number 02 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 41} cebstateFlagAnalogVoltage02 OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Analog Voltage number 02 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBAnalogEntry 42} cebminValueAnalogVoltage02 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 43} cebmaxValueAnalogVoltage02 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Analog Voltage number 02 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 44} cebalarmStateAnalogVoltage02 OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Analog Voltage number 02 Analog parameter." ::= { gx2CEBAnalogEntry 45} -- New Parameter ceblabelAnalogVoltage03 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Analog Voltage number 03 Analog parameter." ::= { gx2CEBAnalogEntry 46} cebuomAnalogVoltage03 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Analog Voltage number 03 Analog parameter." ::= { gx2CEBAnalogEntry 47} cebmajorHighAnalogVoltage03 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 48} cebmajorLowAnalogVoltage03 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 49} cebminorHighAnalogVoltage03 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 50} cebminorLowAnalogVoltage03 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 51} cebcurrentValueAnalogVoltage03 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value Analog Voltage number 03 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 52} cebstateFlagAnalogVoltage03 OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Analog Voltage number 03 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBAnalogEntry 53} cebminValueAnalogVoltage03 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 54} cebmaxValueAnalogVoltage03 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Analog Voltage number 03 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 55} cebalarmStateAnalogVoltage03 OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Analog Voltage number 03 Analog parameter." ::= { gx2CEBAnalogEntry 56} -- New Parameter ceblabelAnalogVoltage04 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Analog Voltage number 04 Analog parameter." ::= { gx2CEBAnalogEntry 57} cebuomAnalogVoltage04 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Analog Voltage number 04 Analog parameter." ::= { gx2CEBAnalogEntry 58} cebmajorHighAnalogVoltage04 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 59} cebmajorLowAnalogVoltage04 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 60} cebminorHighAnalogVoltage04 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 61} cebminorLowAnalogVoltage04 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 62} cebcurrentValueAnalogVoltage04 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value Analog Voltage number 04 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 63} cebstateFlagAnalogVoltage04 OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Analog Voltage number 04 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBAnalogEntry 64} cebminValueAnalogVoltage04 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 65} cebmaxValueAnalogVoltage04 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Analog Voltage number 04 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 66} cebalarmStateAnalogVoltage04 OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Analog Voltage number 04 Analog parameter." ::= { gx2CEBAnalogEntry 67} -- New Parameter ceblabelAnalogVoltage05 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Analog Voltage number 05 Analog parameter." ::= { gx2CEBAnalogEntry 68} cebuomAnalogVoltage05 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Analog Voltage number 05 Analog parameter." ::= { gx2CEBAnalogEntry 69} cebmajorHighAnalogVoltage05 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 70} cebmajorLowAnalogVoltage05 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 71} cebminorHighAnalogVoltage05 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 72} cebminorLowAnalogVoltage05 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2CEBAnalogEntry 73} cebcurrentValueAnalogVoltage05 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value Analog Voltage number 05 Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 74} cebstateFlagAnalogVoltage05 OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Analog Voltage number 05 Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBAnalogEntry 75} cebminValueAnalogVoltage05 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 76} cebmaxValueAnalogVoltage05 OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Analog Voltage number 05 Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2CEBAnalogEntry 77} cebalarmStateAnalogVoltage05 OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Analog Voltage number 01 Analog parameter." ::= { gx2CEBAnalogEntry 78} -- ************************ Digital parameters ********************************** -- ************************ STATUS parameters *********************************** gx2CEBStatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2CEBStatusEntry 1} --New Parameter ceblabelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2CEBStatusEntry 2} cebvalueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2CEBStatusEntry 3} cebstateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBStatusEntry 4} --New Parameter ceblabelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2CEBStatusEntry 5} cebvalueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2CEBStatusEntry 6} cebstateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBStatusEntry 7} --New Parameter ceblabelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2CEBStatusEntry 8} cebvalueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2CEBStatusEntry 9} cebstateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBStatusEntry 10} --New Parameter ceblabelAlarmDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2CEBStatusEntry 11} cebvalueAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2CEBStatusEntry 12} cebstateflagAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2CEBStatusEntry 13} -- ************ FACTORY DATA **************** gx2CEBFactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2CEBFactoryEntry 1} cebbootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2CEBFactoryEntry 2} cebbootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail)" ::= { gx2CEBFactoryEntry 3} cebbank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0. The display formate for the data is Hex." ::= { gx2CEBFactoryEntry 4} cebbank2CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1.The display formate for the data is Hex." ::= { gx2CEBFactoryEntry 5} cebprgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2CEBFactoryEntry 6} cebfactoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2CEBFactoryEntry 7} cebcalculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), na(2), alarm(3) } ACCESS read-only STATUS obsolete DESCRIPTION "This object indicates which of the Enums will have the CRC calculated." ::= { gx2CEBFactoryEntry 8} cebhourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2CEBFactoryEntry 9} cebflashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2CEBFactoryEntry 10} cebflashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2CEBFactoryEntry 11} cebflashBankARev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0. The rev is 2 characters." ::= { gx2CEBFactoryEntry 12} cebflashBankBRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1. The rev is 2 characters." ::= { gx2CEBFactoryEntry 13} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** --*************************************************************************** -- ***********!!! THE TRAP SECTION HAS NOT BEEN COMPLETED YET !!! *********** --*************************************************************************** -- ************************************************************************** -- CEB Module traps -- ************************************************************************** trapCEBConfigChangeInteger TRAP-TYPE ENTERPRISE gx2CEB VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapCEBConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2CEB VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapCEBfanCurrentAlarm TRAP-TYPE ENTERPRISE gx2CEB VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapCEBModuleTempAlarm TRAP-TYPE ENTERPRISE gx2CEB VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapCEBFlashAlarm TRAP-TYPE ENTERPRISE gx2CEB VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error during Flash memory operations." ::= 5 trapCEBBankBootAlarm TRAP-TYPE ENTERPRISE gx2CEB VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1." ::= 6 trapCEBAlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2CEB VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 7 trapCEBFactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2CEB VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 8 END