| OID symbolic | OID numeric | Type | Access | Description |
| nec | 1.3.6.1.4.1.119 | | | |
| nec_mib | 1.3.6.1.4.1.119.2 | | | |
| necProductDepend | 1.3.6.1.4.1.119.2.3 | | | |
| atomis_mib | 1.3.6.1.4.1.119.2.3.14 | | | |
| m5core_mib | 1.3.6.1.4.1.119.2.3.14.3 | | | |
| node | 1.3.6.1.4.1.119.2.3.14.3.1 | | | |
| INT nodeOperStatus | 1.3.6.1.4.1.119.2.3.14.3.1.1 | INTEGER | read-only | Operational status of the LS100. |
| nodeIfConfTable | 1.3.6.1.4.1.119.2.3.14.3.1.2 | | not-accessible | The configuration of the line cards. |
| nodeIfConfEntry | 1.3.6.1.4.1.119.2.3.14.3.1.2.1 | | not-accessible | The configuration of a line card. |
| INT nodeIfConfIndex | 1.3.6.1.4.1.119.2.3.14.3.1.2.1.1 | INTEGER | read-only | The index of the table. Same as ifIndex. |
| INT nodeIfConfPhysType | 1.3.6.1.4.1.119.2.3.14.3.1.2.1.2 | INTEGER | read-only | The PMD/physical layer format of the line card. |
| STR nodeIfConfRev | 1.3.6.1.4.1.119.2.3.14.3.1.2.1.3 | DisplayString | read-only | The revision of the line cards. |
| INT nodeIfConfStatus | 1.3.6.1.4.1.119.2.3.14.3.1.2.1.4 | INTEGER | read-only | Operational status of the line card. |
| INT nodeFanStatus | 1.3.6.1.4.1.119.2.3.14.3.1.3 | INTEGER | read-only | Operational status of the Fan. |
| INT nodeUpcWindowSize | 1.3.6.1.4.1.119.2.3.14.3.1.4 | INTEGER | read-write | UPC window size. Integer Wi represents Wi X 512 cell time.
Wi=1 correspond to 1.4msec. Wi=120 correspond to 168msec.
It is not allowed to change window size when any PVC
exists. |
| INT nodeBestEffortBufferSize | 1.3.6.1.4.1.119.2.3.14.3.1.5 | INTEGER | read-write | Input buffer capacity for Best Effort traffic(Bb). The
number of cells stored in the buffer is Bb X 128. The
default value is 8. The sum of the buffer capacity is
2047 cells. |
| INT nodeGuaranteedBufferSize | 1.3.6.1.4.1.119.2.3.14.3.1.6 | INTEGER | read-write | Input buffer capacity for Guaranteed traffic(Bg). The
number of cells stored in the buffer is Bg X 128. The
default value is 0. The sum of the buffer capacity is
2047 cells. |
| INT nodeBestEffortBufferThreshold | 1.3.6.1.4.1.119.2.3.14.3.1.7 | INTEGER | read-write | Threshold buffer capacity for Best Effort traffic. If
the number of cells stored in the buffer exceeds this
threshold, cells with CLP=1 and traffic defined as UBR
will be discarded. |
| INT nodeGuaranteedBufferThreshold | 1.3.6.1.4.1.119.2.3.14.3.1.8 | INTEGER | read-write | Threshold buffer capacity for Guaranteed traffic. If
the number of cells stored in the buffer exceeds this
threshold, cells with CLP=1 and traffic defined as VBR
will be discarded. |
| INT nodeSaveConf | 1.3.6.1.4.1.119.2.3.14.3.1.9 | INTEGER | read-write | Save system configuration information including the PVC
table to the non-volatile memory. Writing a value of
save(1) saves the configiration data. Writing the value
noOperation(2) has no effect.
When read, this object always has the value noOperation(2). |
| INT nodeSaveResult | 1.3.6.1.4.1.119.2.3.14.3.1.10 | INTEGER | read-only | Indicates the result of the save command issued from NMS.
The result is either success/temporary failure/notReady. |
| INT nodeReset | 1.3.6.1.4.1.119.2.3.14.3.1.11 | INTEGER | read-write | Writing the value reset(1) resets the system. Writing
the value noOperation(2) has no effect. When read, this
object always has the value noOperation(2). |
| linf | 1.3.6.1.4.1.119.2.3.14.3.2 | | | |
| linfStatusTable | 1.3.6.1.4.1.119.2.3.14.3.2.1 | | not-accessible | Status of the line cards including ATM specific information. |
| linfStatusEntry | 1.3.6.1.4.1.119.2.3.14.3.2.1.1 | | not-accessible | Status of a line card including ATM specific information. |
| INT linfIndex | 1.3.6.1.4.1.119.2.3.14.3.2.1.1.1 | INTEGER | read-only | Same as ifIndex |
| INT linfStatus | 1.3.6.1.4.1.119.2.3.14.3.2.1.1.2 | INTEGER | read-only | Status of line interface |
| INT linfConf | 1.3.6.1.4.1.119.2.3.14.3.2.1.1.3 | INTEGER | read-write | Line card type. |
| INT linfFwdAvailableBandWidth | 1.3.6.1.4.1.119.2.3.14.3.2.1.1.4 | INTEGER | read-only | The amount of bandwidth (Mbps) available/unallocated in
the forward (incoming) direction. |
| INT linfBkwdAvailableBandWidth | 1.3.6.1.4.1.119.2.3.14.3.2.1.1.5 | INTEGER | read-only | The amount of bandwidth (Mbps) available/unallocated in
the backward (outgoing) direction. |
| conn | 1.3.6.1.4.1.119.2.3.14.3.3 | | | |
| INT connPvcIndexNext | 1.3.6.1.4.1.119.2.3.14.3.3.1 | INTEGER | read-only | The next available index for a row of the connPvcTable. |
| INT connPvcIndexEnable | 1.3.6.1.4.1.119.2.3.14.3.3.2 | INTEGER | read-write | When read, this object is the current minimum value of
an index in the connPvcTable. Writing this value has no
effect. |
| connPvcTable | 1.3.6.1.4.1.119.2.3.14.3.3.3 | | not-accessible | The table containing information on current PVC/SVCs.
Currently, only PVCs are represented in this table.
The table is also used to establish and delete PVCs.
1. PVC establishment procedure
(1) Read connPvcIndexNext. This value is used as the
value of connPvcIndex for the new connection.
(2) Determine the value of connPvcHighIfIndex. When
creating a new point-to-multipoint connection,
connPvcHighIfIndex must identify the first leaf.
When creating a new point-to-point connection,
connPvcHighIfIndex normally identifies the interface
with the higher value of ifIndex.
(3) Set connPvcRowStatus to 'createAndWait' using the
values of connPvcIndex and connPvcHighIfIndex as indexes.
This causes the switch to create the new row with some
objects being set to default values. The parameters for
which there is no reasonable default are set to 0xffffffff.
Object Default
connPvcTopology bidirectionalVCC(2)
connPvcTrafficType trafficUBR(4)
connPvcLowIfIndex 0xffffffff
connPvcLowVPI 0xffffffff
connPvcLowVCI 0xffffffff
connPvcLowUpcParam 512
connPvcLowUpc pass(1)
connPvcLowThroughput 0
connPvcHighVPI 0xffffffff
connPvcHighVCI 0xffffffff
connPvcHighUpcParam 512
connPvcHighUpc pass(1)
connPvcHighThroughput 0
The switch then sets the value of connPvcRowStatus to
'notReady'. The default values can be read by the NMS.
(4) The values of the above objects which are set to
0xffffffff must be modified, and the values of any other
objects can be changed. When establishing a VP connection,
connPvcLowVCI and connPvcHighVCI should be set to 0.
When connPvcTrafficType is set to trafficUBR, the values
of connPvcLowThroughput and connPvcHighThroughput are
ignored. When all parameters have acceptable values, the
switch sets connPvcRowStatus to 'notInService'.
(5) When the NMS sets connPvcRowStatus to 'active', the
switch validates each parameter's value, and tries to
establish the connection. If this operation fails, the
the cause of the failure is indicated by the value of
connPvcCause.
At present, the switch allows connPvcRowStatus to have a
value of notReady or notInService for only one row at a
time.
2. Adding a new leaf to an existing pt-to-mpt connection
(1) Determine the value of connPvcIndex for the existing
point-to-multipoint connection to which a new leaf is
to be added.
(2) Determine the value of connPvcHighIfIndex as the
ifIndex value of the interface to be used for the new leaf.
(3) Set connPvcRowStatus to 'createAndWait' using the
values of connPvcIndex and connPvcHighIfIndex as indexes.
This causes the switch to create the new leaf with some
objects being set to default values. The parameters for
which there is no reasonable default are set to 0xffffffff.
Object Default
connPvcHighVPI 0xffffffff
connPvcHighVCI 0xffffffff
connPvcHighUpcParam 512
connPvcHighUpc pass(1)
connPvcHighThroughput 0
The switch then sets the value of connPvcRowStatus to
'notReady'. The default values can be read by the NMS.
(4) The NMS must modify the values of connPvcHighVPI and
connPvcHighVCI, and can modify the values of connPvcHighUpc,
connPvcHighUpcParam and connPvcHighThroughput. When
establishing a VP connection, connPvcHighVCI should
be set to 0. The NMS should not change the values of
the following objects:
connPvcTopology
connPvcTrafficType
connPvcLowIfIndex
connPvcLowVPI
connPvcLowVCI
connPvcLowUpcParam
connPvcLowUpc
connPvcLowThroughput
When all parameters have acceptable values, the switch
sets connPvcRowStatus to 'notInService'.
(5) When the NMS sets connPvcRowStatus to 'active', the
switch validates each parameter's value, and tries to add
the new leaf to the original connection. If this operation
fails, the cause of the failure is indicated by the value
of connPvcCause.
3. PVC deletion procedure
(1) Set the connPvcRowStatus to 'destroy'.
If the row exists but is impossible to delete, the cause
of the failure is indicated by the value of connPvcCause.
If the deletion is successful, the row is deleted
(including the instance of connPvcCause for that row).
Notes:
- a row representing a terminating VP will not have
instances of the following objects: connPvcLowUpc,
connPvcLowUpcParam, connPvcLowThroughput, connPvcHighUpc,
connPvcHighUpcParam, connPvcHighThroughput,
connPvcLowOutCells, connPvcHighInCells,
connPvcHighUpcViolatedCells, connPvcLowInCells,
connPvcHighOutCells, and connPvcLowUpcViolatedCells.
- a row representing a connection between the
gateway-PAD (the switch's internal port) and a line
interface will not have instances of the following
objects: connPvcLowUpc, connPvcLowUpcParam,
connPvcLowThroughput, connPvcHighUpc, connPvcHighUpcParam,
connPvcHighThroughput, connPvcHighOutCells,
connPvcHighInCells, and connPvcHighUpcViolatedCells. |
| connPvcEntry | 1.3.6.1.4.1.119.2.3.14.3.3.3.1 | | not-accessible | A row in the table is used to show the current PVC/SVCs. |
| INT connPvcIndex | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.1 | INTEGER | read-only | A unique value to identify this point-to-point
or point-to-multipoint connection.
A point-to-multipoint connection has multiple
rows in this table, one for each leaf, each
one having the same value of this object. |
| INT connPvcTopology | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.2 | INTEGER | read-write | Topology of the connection. |
| INT connPvcTrafficType | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.3 | INTEGER | read-write | Traffic Type. |
| INT connPvcLowIfIndex | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.4 | INTEGER | read-write | The line interface number (ifIndex) of the low port.
Normally, the low port has a lower ifIndex value than
the high port. However, for point-to-multipoint
connections, the root is always the low port, regardless
of whether it is greater or smaller than the port numbers
of individual leaves. |
| INT connPvcLowVPI | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.5 | INTEGER | read-write | VPI value of the connection on the low port. |
| INT connPvcLowVCI | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.6 | INTEGER | read-write | VCI value of the connection on the low port. |
| INT connPvcLowUpcParam | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.7 | INTEGER | read-write | Number of cells allowed to be sent in the unit cell
time (512 cell times). |
| INT connPvcLowUpc | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.8 | INTEGER | read-write | The action to take on a UPC violation for this connection
on the low port. The tagging action is not supported by
current hardware. |
| INT connPvcLowThroughput | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.9 | INTEGER | read-write | Average rate of the connection (Mbps). Direction is from
the low port to high port. This parameter is valid
for the connection whose traffic type is CBR or VBR. |
| INT connPvcHighIfIndex | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.10 | INTEGER | read-only | The line interface number (ifIndex) of the high port.
Normally, the high port has a higher ifIndex value than
the low port. However, for point-to-multipoint
connections, the root is always the low port, regardless
of whether it is greater or smaller than the port numbers
of individual leaves. Line interface number 17
corresponds to gateway (the switch's internal port). |
| INT connPvcHighVPI | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.11 | INTEGER | read-write | The VPI value of the connection on the high port. |
| INT connPvcHighVCI | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.12 | INTEGER | read-write | The VCI value of the connection on the high port. |
| INT connPvcHighUpcParam | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.13 | INTEGER | read-write | Number of cells allowed to be sent in the unit cell
time (512 cell times). |
| INT connPvcHighUpc | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.14 | INTEGER | read-write | The action to take on a UPC violation for this connection
on the high port. The tagging action is not supported by
current hardware. |
| INT connPvcHighThroughput | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.15 | INTEGER | read-write | Average rate of the connection (Mbps). Direction is from
the high port to low port. This parameter is valid
for the connection whose traffic type is CBR or VBR. |
| CTR connPvcLowInCells | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.16 | Counter | read-only | Number of incoming cells on this connection on low port. |
| CTR connPvcHighOutCells | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.17 | Counter | read-only | Number of outgoing cells on this connection on the high
port. |
| CTR connPvcHighInCells | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.18 | Counter | read-only | Number of incoming cells on this connection on high port.
(Valid for bi-direction connections only). |
| CTR connPvcLowOutCells | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.19 | Counter | read-only | Number of outgoing cells on this connection on the low.
port. (Valid for bi-direction connections only). |
| CTR connPvcLowUpcViolatedCells | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.20 | Counter | read-only | Number of UPC violation cells incoming from the low
port. |
| CTR connPvcHighUpcViolatedCells | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.21 | Counter | read-only | Number of UPC violation cells incoming from the high
port. (Valid for bi-direction connections only). |
| INT connPvcRowStatus | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.22 | INTEGER | read-write | The status of this row.
'active' indicates that the connection is in use.
'notInService' indicates that the row exists but
the connection is not established.
'notReady' indicates that the row exists in the agent,
but is missing information necessary in order
to be established.
'createAndWait' supplied by a management station
wishing to create a new row.
'destroy' supplied by a management station wishing to
delete the row. |
| INT connPvcCause | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.23 | INTEGER | read-only | The result of the PVC establishment/deletion. |
| INT connPvcKind | 1.3.6.1.4.1.119.2.3.14.3.3.3.1.24 | INTEGER | read-only | This object identifies the connection is SVC or PVC. |
| perf | 1.3.6.1.4.1.119.2.3.14.3.4 | | | |
| INT perfTrapEnable | 1.3.6.1.4.1.119.2.3.14.3.4.1 | INTEGER | read-write | The status of performance monitoring traps. Its value
does not affect other traps, such as coldStart. |
| perfIfTable | 1.3.6.1.4.1.119.2.3.14.3.4.2 | | not-accessible | Table of performance monitoring information. |
| perfIfEntry | 1.3.6.1.4.1.119.2.3.14.3.4.2.1 | | not-accessible | Performance monitoring information for a specific line. |
| INT perfIfIndex | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.1 | INTEGER | read-only | Line interface number. Same as ifIndex. |
| CTR perfIfLcvs | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.2 | Counter | read-only | Line Code Violation. This object is valid only for
DS3/E3. |
| CTR perfIfParitySections | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.3 | Counter | read-only | Number of B1 (BIP) errors(OC-3c, UTP-5),
Number of C-bit parity violation(DS3),
Number of CRC-6 violation(DS1). |
| CTR perfIfParityLines | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.4 | Counter | read-only | Number of B2 (BIP) errors(OC-3c, UTP-5),
Number of P-bit parity violation(DS3). |
| CTR perfIfParityPaths | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.5 | Counter | read-only | Number of B3 (BIP) errors(OC-3c, UTP-5),
Number of PLCP BIP violation(DS3). |
| CTR perfIfHecErrors | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.6 | Counter | read-only | Number of HEC errors detected. |
| CTR perfIfMisDelivdCells | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.7 | Counter | read-only | Number of misdelivered cells. |
| CTR perfIfOverFlowCells | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.8 | Counter | read-only | Number of cells discarded due to buffer overflow. |
| CTR perfIfInCBRCells | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.9 | Counter | read-only | Number of received CBR cells. |
| CTR perfIfOutCBRCells | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.10 | Counter | read-only | Number of transmitted CBR cells. |
| CTR perfIfInVBRCells | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.11 | Counter | read-only | Number of received VBR cells. |
| CTR perfIfOutVBRCells | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.12 | Counter | read-only | Number of transmitted VBR cells. |
| CTR perfIfInUBRCells | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.15 | Counter | read-only | Number of received UBR cells. |
| CTR perfIfOutUBRCells | 1.3.6.1.4.1.119.2.3.14.3.4.2.1.16 | Counter | read-only | Number of transmitted UBR cells. |