LS100-R3-MIB :: perfIfParityPaths

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LS100-R3-MIB › perfIfParityPaths

perfIfParityPaths

Module: LS100-R3-MIB

OID (symbolic): LS100-R3-MIB::perfIfParityPaths

OID (numeric): 1.3.6.1.4.1.119.2.3.14.3.4.2.1.5

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: Number of B3 (BIP) errors(OC-3c, UTP-5), Number of PLCP BIP violation(DS3).

What is perfIfParityPaths?

Running count of path-layer parity errors (B3/BIP for OC-3c and UTP-5, PLCP BIP violations for DS3) detected on this interface.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.119.2.3.14.3.4.2.1.5
snmpwalk -v2c -c public <target> LS100-R3-MIB::perfIfParityPaths

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.119.2.3.14.3.4.2.1.5.1
snmpget -v2c -c public <target> LS100-R3-MIB::perfIfParityPaths.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> perfIfParityPaths.1

Start monitoring NEC LS100 series switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LS100-R3-MIB::perfIfParityPaths OID value, configure state conditions and alerts, and monitor any NEC LS100 series switch from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.119necA100-R1-MIB
1.3.6.1.4.1.119.2nec_mibA100-R1-MIB
1.3.6.1.4.1.119.2.3necProductDependA100-R1-MIB
1.3.6.1.4.1.119.2.3.14atomis_mibA100-R1-MIB
1.3.6.1.4.1.119.2.3.14.3m5core_mibA100-R1-MIB
1.3.6.1.4.1.119.2.3.14.3.4perfA100-R1-MIB
1.3.6.1.4.1.119.2.3.14.3.4.2perfIfTableLS100-MIB
1.3.6.1.4.1.119.2.3.14.3.4.2.1perfIfEntryLS100-MIB
Numeric OIDNameModule
1.3.6.1.4.1.119.2.3.14.3.4.2.1.5perfIfParityPathsLS100-R3-MIB