| OID symbolic | OID numeric | Type | Access | Description |
| finMIBCompliance | 1.3.6.1.2.1.43.2.5 | | | The compliance statement for agents that implement the
finisher MIB. |
| finMIBGroups | 1.3.6.1.2.1.43.2.6 | | | |
| finDeviceGroup | 1.3.6.1.2.1.43.2.6.1 | | | The finisher device group. |
| finSupplyGroup | 1.3.6.1.2.1.43.2.6.2 | | | The finisher supply group. |
| finSupplyMediaInputGroup | 1.3.6.1.2.1.43.2.6.3 | | | The finisher supply, media input group. |
| finDeviceAttributeGroup | 1.3.6.1.2.1.43.2.6.4 | | | The finisher device attribute group. This group is mandatory
for a finisher device that contains an inserter subunit. |
| finDevice | 1.3.6.1.2.1.43.30 | | | |
| finDeviceTable | 1.3.6.1.2.1.43.30.1 | | not-accessible | This table defines the finishing device subunits,
including information regarding possible configuration
options and the status for each finisher device subunit. |
| finDeviceEntry | 1.3.6.1.2.1.43.30.1.1 | | not-accessible | There is an entry in the finishing device table for each
possible finisher process. Each individual finisher process is
implemented by a finishing device represented in this table. |
| I32 finDeviceIndex | 1.3.6.1.2.1.43.30.1.1.1 | Integer32 | not-accessible | A unique value used to identify a finisher process.
Although these values may change due to a major
reconfiguration of the printer system (e.g., the addition
of new finishing processes), the values are normally
expected to remain stable across successive power cycles. |
| FIN finDeviceType | 1.3.6.1.2.1.43.30.1.1.2 | FinDeviceTypeTC | read-only | Defines the type of finishing process associated with this
table row entry. |
| PRE finDevicePresentOnOff | 1.3.6.1.2.1.43.30.1.1.3 | PresentOnOff | read-write | Indicates if this finishing device subunit is available
and whether the device subunit is enabled. |
| PRT finDeviceCapacityUnit | 1.3.6.1.2.1.43.30.1.1.4 | PrtCapacityUnitTC | read-only | The unit of measure for specifying the capacity of this
finisher device subunit. |
| I32 finDeviceMaxCapacity | 1.3.6.1.2.1.43.30.1.1.5 | Integer32 | read-write | The maximum capacity of this finisher device subunit in
finDeviceCapacityUnits. If the device can reliably sense
this value, the value is sensed by the finisher device
and is read-only: otherwise the value may be written by a
management or control console application. The value (-1)
means other and specifically indicates that the device
places no restrictions on this parameter. The value (-2)
means unknown. |
| I32 finDeviceCurrentCapacity | 1.3.6.1.2.1.43.30.1.1.6 | Integer32 | read-write | The current capacity of this finisher device subunit in
finDeviceCapacityUnits. If the device can reliably sense
this value, the value is sensed by the finisher and is
read-only: otherwise the value may be written by a
management or control console application. The value (-1)
means other and specifically indicates that the device
places no restrictions on this parameter. The value (-2)
means unknown. |
| OCT finDeviceAssociatedMediaPaths | 1.3.6.1.2.1.43.30.1.1.7 | OCTET STRING | read-only | Indicates the media paths which can supply media for this
finisher device. The value of this object is a bit map in an
octet string with each position representing the value of a
prtMediaPathIndex. For a media path that can be a source
for this finisher device subunit, the bit position equal
to one less than the value of prtMediaPathIndex will be set.
The bits are numbered starting with the most significant bit of
the first byte being bit 0, the least significant bit of the
first byte being bit 7, the most significant of the second byte
being bit 8, and so on. |
| OCT finDeviceAssociatedOutputs | 1.3.6.1.2.1.43.30.1.1.8 | OCTET STRING | read-only | Indicates the printer output subunits this finisher device
subunit services. The value of this object is a bit map in an
octet string with each position representing the value of a
prtOutputIndex. For an output subunit that is serviced
by this finisher device subunit, the bit position equal
to one less than the value of prtOutputIndex will be set.
The bits are numbered starting with the most significant bit of
the first byte being bit 0, the least significant bit of the
first byte being bit 7, the most significant of the second byte
being bit 8, and so on. |
| PRT finDeviceStatus | 1.3.6.1.2.1.43.30.1.1.9 | PrtSubUnitStatusTC | read-only | Indicates the current status of this finisher device
subunit. |
| STR finDeviceDescription | 1.3.6.1.2.1.43.30.1.1.10 | PrtLocalizedDescriptionStringTC | read-only | A free form text description of this device subunit in the
localization specified by prtGeneralCurrentLocalization. |
| finSupply | 1.3.6.1.2.1.43.31 | | | |
| finSupplyTable | 1.3.6.1.2.1.43.31.1 | | not-accessible | Each unique source of supply is an entry in the finisher
supply table. Each supply entry has its own
characteristics associated with it such as colorant and
current supply level. |
| finSupplyEntry | 1.3.6.1.2.1.43.31.1.1 | | not-accessible | A list of finisher devices, with their associated
supplies and supplies characteristics. |
| I32 finSupplyIndex | 1.3.6.1.2.1.43.31.1.1.1 | Integer32 | not-accessible | A unique value used by a finisher to identify this supply
container/receptacle. Although these values may change
due to a major reconfiguration of the finisher (e.g., the
addition of new supply sources to the finisher), values
are normally expected to remain stable across successive
power cycles. |
| I32 finSupplyDeviceIndex | 1.3.6.1.2.1.43.31.1.1.2 | Integer32 | read-only | The value of finDeviceIndex corresponding to the finishing
device subunit with which this finisher supply is associated.
The value zero indicates the associated finishing device is
Unknown. |
| PRT finSupplyClass | 1.3.6.1.2.1.43.31.1.1.3 | PrtMarkerSuppliesClassTC | read-only | This value indicates whether this supply entity
represents a supply that is consumed or a container that
is filled. |
| PRT finSupplyType | 1.3.6.1.2.1.43.31.1.1.4 | PrtMarkerSuppliesTypeTC | read-only | The type of this supply. |
| STR finSupplyDescription | 1.3.6.1.2.1.43.31.1.1.5 | PrtLocalizedDescriptionStringTC | read-only | The description of this supply/receptacle in text useful
for operators and management applications and in the
localization specified by prtGeneralCurrentLocalization. |
| PRT finSupplyUnit | 1.3.6.1.2.1.43.31.1.1.6 | PrtMarkerSuppliesSupplyUnitTC | read-only | Unit of measure of this finisher supply container or
receptacle. |
| I32 finSupplyMaxCapacity | 1.3.6.1.2.1.43.31.1.1.7 | Integer32 | read-write | The maximum capacity of this supply container/receptacle
expressed in Supply Units. If this supply container/
receptacle can reliably sense this value, the value is
sensed and is read-only; otherwise the value may be
written by a control panel or management application. The
value (-1) means other and places no restrictions on this
parameter. The value (-2) means unknown. |
| I32 finSupplyCurrentLevel | 1.3.6.1.2.1.43.31.1.1.8 | Integer32 | read-write | The current level if this supply is a container; the
remaining space if this supply is a receptacle. If this
supply container/receptacle can reliably sense this value,
the value is sensed and is read-only; otherwise the value
may be written by a control panel or management
application. The value (-1) means other and places no
restrictions on this parameter. The value (-2) means
unknown. A value of (-3) means that the printer knows there
is some supply or remaining space. |
| OCT finSupplyColorName | 1.3.6.1.2.1.43.31.1.1.9 | OCTET STRING | read-only | The name of the color associated with this supply. |
| finSupplyMediaInput | 1.3.6.1.2.1.43.32 | | | |
| finSupplyMediaInputTable | 1.3.6.1.2.1.43.32.1 | | not-accessible | The input subunits associated with a finisher supply media
are each represented by an entry in this table. |
| finSupplyMediaInputEntry | 1.3.6.1.2.1.43.32.1.1 | | not-accessible | A list of finisher supply media input subunit features and
characteristics. |
| I32 finSupplyMediaInputIndex | 1.3.6.1.2.1.43.32.1.1.1 | Integer32 | not-accessible | A unique value used by a finisher to identify this supply
media input subunit. Although these values may change
due to a major reconfiguration of the finisher (e.g., the
addition of new supply media input sources to the
finisher), values are normally expected to remain stable
across successive power cycles. |
| I32 finSupplyMediaInputDeviceIndex | 1.3.6.1.2.1.43.32.1.1.2 | Integer32 | read-only | The value of finDeviceIndex corresponding to the finishing
device subunit with which this finisher media supply is
associated. The value zero indicates the associated device
is unknown. |
| I32 finSupplyMediaInputSupplyIndex | 1.3.6.1.2.1.43.32.1.1.3 | Integer32 | read-only | The value of finSupplyIndex corresponding to the finishing
supply subunit with which this finisher media supply is
associated. The value zero indicates the associated finishing
supply is unknown or there is no applicable finisher supply
table entry. |
| PRT finSupplyMediaInputType | 1.3.6.1.2.1.43.32.1.1.4 | PrtInputTypeTC | read-only | The type of technology (discriminated primarily according
to the feeder mechanism type) employed by the input
subunit. |
| PRT finSupplyMediaInputDimUnit | 1.3.6.1.2.1.43.32.1.1.5 | PrtMediaUnitTC | read-only | The unit of measure for specifying dimensional values for
this input device. |
| I32 finSupplyMediaInputMediaDimFeedDir | 1.3.6.1.2.1.43.32.1.1.6 | Integer32 | read-write | This object provides the value of the dimension in the
feed direction of the media that is placed or will be
placed in this input device. Feed dimension measurements
are taken parallel to the feed direction of the device and
measured in finSupplyMediaInputDimUnits. If this input
device can reliably sense this value, the value is sensed
and is read-only access. Otherwise the value is read-write
access and may be written by management or control panel
applications. The value (-1) means other and specifically
indicates that this device places no restrictions on this
parameter. The value (-2) indicates unknown. |
| I32 finSupplyMediaInputMediaDimXFeedDir | 1.3.6.1.2.1.43.32.1.1.7 | Integer32 | read-write | This object provides the value of the dimension across the
feed direction of the media that is placed or will be
placed in this input device. The cross feed direction is
ninety degrees relative to the feed direction on this
device and measured in finSupplyMediaInputDimUnits. If
this input device can reliably sense this value, the value
is sensed and is read-only access. Otherwise the value is
read-write access and may be written by management or
control panel applications. The value (-1) means other and
specifically indicates that this device places no
restrictions on this parameter. The value (-2) indicates
unknown. |
| PRT finSupplyMediaInputStatus | 1.3.6.1.2.1.43.32.1.1.8 | PrtSubUnitStatusTC | read-only | This value indicates the current status of this input
device. |
| OCT finSupplyMediaInputMediaName | 1.3.6.1.2.1.43.32.1.1.9 | OCTET STRING | read-write | The name of the current media contained in this input
device. Examples are Engineering Manual Cover, Section A Tab
Divider or any ISO standard names. |
| OCT finSupplyMediaInputName | 1.3.6.1.2.1.43.32.1.1.10 | OCTET STRING | read-write | The name assigned to this input subunit. |
| STR finSupplyMediaInputDescription | 1.3.6.1.2.1.43.32.1.1.11 | PrtLocalizedDescriptionStringTC | read-only | A free form text description of this input subunit in the
localization specified by prtGeneralCurrentLocalization. |
| PRE finSupplyMediaInputSecurity | 1.3.6.1.2.1.43.32.1.1.12 | PresentOnOff | read-write | Indicates if this subunit has some security associated
with it. |
| I32 finSupplyMediaInputMediaWeight | 1.3.6.1.2.1.43.32.1.1.13 | Integer32 | read-write | The weight of the media associated with this Input device
in grams per meter squared. The value (-1) means other
and specifically indicates that the device places no
restriction on this parameter. The value (-2) means
unknown. This object can be used to calculate the weight
of individual pages processed by the document finisher.
This value, when multiplied by the number of pages in a
finished set, can be used to calculate the weight of a set
before it is inserted into a mailing envelope. |
| I32 finSupplyMediaInputMediaThickness | 1.3.6.1.2.1.43.32.1.1.14 | Integer32 | read-write | This object identifies the thickness of the input media
processed by this document input subunit measured in
micrometers. This value may be used by devices (or
operators) to set up proper machine tolerances for the
feeder operation. The value (-2) indicates that the media
thickness is unknown or not used in the setup for this
input subunit. |
| OCT finSupplyMediaInputMediaType | 1.3.6.1.2.1.43.32.1.1.15 | OCTET STRING | read-write | The name of the type of medium associated with this input
subunit. |
| finDeviceAttribute | 1.3.6.1.2.1.43.33 | | | |
| finDeviceAttributeTable | 1.3.6.1.2.1.43.33.1 | | not-accessible | The attribute table defines special parameters that are
applicable only to a minority of the finisher devices.
An attribute table entry is used, rather than unique
objects, to minimize the number of MIB objects and to
allow for expansion without the addition of MIB objects.
Each finisher device is represented by a separate row
in the device subunit attribute table. |
| finDeviceAttributeEntry | 1.3.6.1.2.1.43.33.1.1 | | not-accessible | Each entry defines a finisher function parameter that
cannot be represented by an object in the finisher
device subunit table. |
| FIN finDeviceAttributeTypeIndex | 1.3.6.1.2.1.43.33.1.1.1 | FinAttributeTypeTC | not-accessible | Defines the attribute type represented by this row. |
| I32 finDeviceAttributeInstanceIndex | 1.3.6.1.2.1.43.33.1.1.2 | Integer32 | not-accessible | An index that allows the discrimination of an attribute
instance when the same attribute occurs multiple times for
a specific instance of a finisher function. The value of
this index shall be 1 if only a single instance of the
attribute occurs for the specific finisher function.
Additional values shall be assigned in a contiguous manner. |
| I32 finDeviceAttributeValueAsInteger | 1.3.6.1.2.1.43.33.1.1.3 | Integer32 | read-write | Defines the integer value of the attribute. The value of
the attribute is represented as an integer if the
finAttributeTypeTC description for the attribute has the
tag 'INTEGER:'.
Depending upon the attribute enum definition, this object
may be either an integer, a counter, an index, or an enum.
Attributes for which the concept of an integer value is
not meaningful SHALL return a value of -1 for this
attribute. |
| OCT finDeviceAttributeValueAsOctets | 1.3.6.1.2.1.43.33.1.1.4 | OCTET STRING | read-write | Contains the octet string value of the attribute. The
value of the attribute is represented as a string if the
finAttributeTypeTC description for the attribute has the
tag 'OCTETS:'.
Depending upon the attribute enum definition, this object
may be either a coded character set string (text) or a
binary octet string. Attributes for which the concept of
an octet string value is not meaningful SHALL contain a
zero length string. |
| finisherMIB | 1.3.6.1.2.1.111 | | | The MIB module for management of printers.
Copyright (C) The Internet Society (2004). This
version of this MIB module was published
in RFC 3806. For full legal notices see the RFC itself. |